PREVENTIVE MAINTENANCE CHECKLIST

Machine Name: Air Comp Work Order No: Week


Type/I.D No: Plant:
Location: YEAR

Note: Please tick [ √ ] if found o.k and tick [ X ] and note remark if found not ok. Note [ NA ] for Not Applicable.
Item 1 Air Compressor Act Requirement Standard Status Remarks
1.1 Check the ambient temperature( monitor diagram) I Sufficient air flow into unit to cool down < 40 deg C
1.2 Check the air end motor. I Optimum running condition Functioning well & in normal condition
1.3 Record the compressor running hours. I Serviced according to requirements Refer to Manufacturing Advice
1.4 Record the discharge temperature at the control pa I Oil cooler fan in operation < 95 deg C
1.5 Record any alarm indication (monitor diagram) I All in operation No alarm / caution indication
Item 2 Air Tank Requirement Standard
2.1 Check auto drain functionity I Air releases according to the timer Unit in operation
2.2 Clean the CRD unit C In operation condensate water draining out Cleaning the parts from rust debris

Item 3 Air Dryer Requirement Standard


3.1 Check any abnormal sound I Check if operating properly & overall condition No abnormal sound or jerk.
3.2 Inlet pipe and outlet temperature difference I Inlet pipe warmer / outlet pipe cold by hand Temp diffence inlet & outlet pipe
3.3 Dew Point @ panel I To condesate and dry the system air < 5 deg C
3.4 Check auto drain functionity I In operation condensate water draining out Unit in operation

Report if additional work carried out: * Switch OFF the machine before work Check by
* Be aware on slip hazards Sign:
* Be aware of sharp edges
* Be aware of pinch points and crushing hazards. Date:
* Do not remove any air fitting if still have pressure in the line.
* Use LOTO procedure
Action Note: C = Cleaning, G = Greasing, I = Inspection, L = Lubricate, T = Test Run. Verify by:

Navin
PREVENTIVE MAINTENANCE CHECKLIST
Machine Name : Air Comp Plant: Month: Jan Feb Mac Apr May Jun
Type/I.D No : July Aug Sept Oct Nov Dec
Location : Work Order No: Year

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Air Compressor
Check the ambient temperature < 40deg C
Check the air end motor. No abnormal sound
Record the compressor running hours.
Record the discharge temperature at the control panel
Record any alarm indication (monitor diagram)
Air Tank
Check auto drain functionity
Clean the CRD unit
Air Dryer
Check any abnormal sound
Inlet pipe and outlet temperature difference
Dew Point @ panel . < 5 deg C
Check auto drain functionity
Sign

Report if additional work carried out : * Switch OFF the machine before work
* Be aware on slip hazards
* Be aware of sharp edges
* Be aware of pinch points and crushing hazards.
* Do not remove any air fitting if still have pressure in the line.
* Use LOTO procedure
Check By :
Sign:
Date: