Alarm Interface Test 16505-2022
Alarm Interface Test 16505-2022
MAN-ES strongly recommend performing below test to verify that AMS will react
according to design in case no information is received from EMS.
The test is to verify that AMS will not raise alarm, slowdown or shutdown based on
missing EMS data. It is done by disrupting the EMS-AMS Modbus.
Test steps:
At a convenient and safe location while operating Engine at low load, but above
slowdown limit:
1. Conduct following tests separately followed by Verification steps 2.1-3:
1.1. disconnect LAN cable 󠆯from port / MOP-B
1.2. disconnect LAN cable from port / PMI DAU
1.3. Power off the EMS computer
2. Confirm that:
2.1. no slowdown or shutdown is requested/activated by AMS
2.2. no alarms – Process value, OoR or any other type alarms are raised in AMS.
Only Acceptable AMS Alarm is one for EMS communication loss.
2.3. values missing in AMS monitoring are indicated:
As missing such as “---“, “N/A”, 󠆯“OoR” 󠆯etc. 󠆯
Not 󠆯as 󠆯physical 󠆯values 󠆯such 󠆯as 󠆯“3276.7 󠆯°C”, 󠆯“327.67 󠆯bar” 󠆯or 󠆯“327.7 󠆯g/kWh” 󠆯etc.
In case above test cause slowdown or shutdown, it is an indication that AMS is not
configured correctly. If assistance from MAN-ES is needed in this respect, please
contact MAN-ES at: OperationControlandElectronics2S@man-es.com
Best regards
MAN Energy Solutions