You are on page 1of 3

1

CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: JAN 28, 2023 Time: 14:59
Job:: PIPE LINE
Licensed To:: SPLM: Edit company name in <system>\company.txt

Table of Contents
LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS...................................................................................
HANGER REPORT ((TABLE DATA FROM DESIGN RUNS)).....................................................................................
2
CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: JAN 28, 2023 Time: 14:59
Job:: PIPE LINE
Licensed To:: SPLM: Edit company name in <system>\company.txt

LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS

1 (HGR) CASE NOT ACTIVE


2 (HGR) CASE NOT ACTIVE
3 (HYD) WW+HP+H
4 (OPE) W+T1+P1+H
5 (SUS) W+P1+H
6 (OCC) W+P1+H+WIN1
7 (OCC) W+P1+H+WIN2
8 (OCC) W+P1+H+WIN3
9 (OCC) W+P1+H+WIN4
10 (OCC) W+P1+H+U1
11 (OCC) W+P1+H-U1
12 (OCC) W+P1+H+U2
13 (OCC) W+P1+H-U2
14 (EXP) L14=L4-L5 CAESAR II 2014 Ver.7.00.00.2800, (Build 14041Date:JAN 28,2023
@14:59 Pg: 1
3
CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: JAN 28, 2023 Time: 14:59
Job:: PIPE LINE
Licensed To:: SPLM: Edit company name in <system>\company.txt

HANGER REPORT
(TABLE DATA FROM DESIGN RUNS)
THEORETICAL ACTUAL
NO. FIG. VERTICAL HOT INSTALLED INSTALLED SPRING HORIZONTAL
NODE REQD NO. SIZE MOVEMENT LOAD LOAD LOAD RATE MOVEMENT

-------+---+-----+----+---(mm.)--+--(N. )-+--(N. )---+--(N. )--(N./mm. )--(mm.)-

260 1 BV35 20 -1.281 102278. 100169. 0. 1646.1 6.530


Binder LOAD VARIATION = 2%

** VARIABLE SUPPORT SPRING DESIGNED ................... SHORT RANGE


MINIMUM ALLOWED SINGLE SPRING LOAD ........... (N. ) 73209.008
MAXIMUM ALLOWED SINGLE SPRING LOAD ........... (N. ) 130826.000
RECOMMENDED INSTALLATION CLEARANCE ........... (mm.) 459.994

-------+---+-----+----+----------+--------+----------+---------+-------+--------

329 1 BV35 17 -1.323 51432. 50505. 0. 700.5 4.298


Binder LOAD VARIATION = 2%

** VARIABLE SUPPORT SPRING DESIGNED ................... SHORT RANGE


MINIMUM ALLOWED SINGLE SPRING LOAD ........... (N. ) 31138.002
MAXIMUM ALLOWED SINGLE SPRING LOAD ........... (N. ) 55655.023
RECOMMENDED INSTALLATION CLEARANCE ........... (mm.) 372.110

-------+---+-----+----+----------+--------+----------+---------+-------+--------

370 1 BV35 10 -0.464 5845. 5803. 0. 91.1 1.869


Binder LOAD VARIATION = 1%

** VARIABLE SUPPORT SPRING DESIGNED ................... SHORT RANGE


MINIMUM ALLOWED SINGLE SPRING LOAD ........... (N. ) 4047.991
MAXIMUM ALLOWED SINGLE SPRING LOAD ........... (N. ) 7234.983
RECOMMENDED INSTALLATION CLEARANCE ........... (mm.) 270.002

-------+---+-----+----+----------+--------+----------+---------+-------+--------