Professional Documents
Culture Documents
NPN/PNP Proximity TERMINAL CONNECTION All safety related codifications, symbols and instructions
Input (Start Pulse) that appear in this operating manual or on the equipment
Micro Switch To view batch count must be strictly followed to ensure the safety of the operating
L personnel as well as the instrument.
1 +12V 8
DISPLAY AND KEYS: 230V AC To view grand total If all the equipment is not handled in a manner specified
50Hz,4VA I/P by the manufacturer, it might impair the protection provided
Upper: 6 digit, 7 segment, 0.40” Red 2 N 9
Display NPN PARAMETER SETTING MODE by the equipment.
Lower: 4 digit, 7 segment, 0.40” Green !
3 I/P 10 Edited parameter value to be set,
Keys SET/ENT, SHIFT, INC, RESET Read complete instructions prior to installation
PNP And move to the next parameter and operation of the unit.
4 GND 11 It will select the digit to modify,
DIMENSION: WARNING : Risk of electric shock.
When value is edited
Size 72 (H) x 72 (W) x 60 (D) mm www.multispanindia.com
It will change the Value of WARNING GUIDELINES
Panel Cutout 68 (H) x 68 (W) mm 5 12 selected digit
NC
WARNING : Risk of electric shock.
GENERAL SPECIFICATION: 6 C 13 1. To prevent the risk of electric shock, power supply to the
RESET
INSTALLATION GUIDELINES equipment must be kept OFF while doing the wiring
Memory Nonvolatile arrangement. Do not touch the terminals while power is
7 NO 14
Counting Direction UP/ DOWN Made in India being supplied.
1. This equipment, being built-in-type, normally becomes a
Front Panel Reset part of main control panel and in such case the terminals 2. To reduce electro magnetic interference, use wire with
Reset Option adequate rating and twists of the same of equal size shall
Terminal Reset PROXY COLERS CODE do not remain accessible to the end user after installation
and internal wiring. be made with shortest connection.
2. Do not allow pieces of metal, wire clippings, or fine metallic 3. Cable used for connection to power source, must have a
OUTPUT SPECIFICATION: +12V OUTPUT GND
fillings from installation to enter the product or else it may cross section of 1mm or greater. These wires should have
Brown Black Blue lead to a safety hazard that may in turn endanger life or insulations capacity made of at least 1.5kV.
Relay Output
cause electrical shock to the operator.
Relay 1 nos. Red Green Black 4. A better anti-noise effect can be expected by using
3. Circuit breaker or mains switch must be installed between standard power supply cable for the instrument.
Relay Type 1 C/O (NO-C-NC) power source and supply terminal to facilitate power ‘ON’ or
Rating 5A, 230V AC ‘OFF’ function. However this mains switch or circuit breaker
must be installed at convenient place normally accessible to
AUXILIARY SUPPLY: the operator.
4. Use and store the instrument within the specified ambient
Supply voltage 230V AC, 50Hz temperature and humidity ranges as mentioned in this
Power consumption manual.
Approx 4 VA @ 230V AC MAX
(VA RATING)
Page -1
PARAMETER SETTING NOTE
1). The proximity switch give pulse to counter everytime the
metal on the roller is sensed.
1 2 3 4 5. 6 Total Length in Mtr.
1 2 3. 4 Speed in Mtr/Min 2). Length of Material ( in meter ) for one revolution
= 3.14 X Diameter (mm)
Press SET
ENT key
3). Total length
= { 3.14 X Diameter (mm) X Number of Revolutions } / 1000
Change by 9 9 9 9 9. 9 Set Length Value
& Key s e t Range :- 000.001 4). Total Meters/Minute
to 99999 mtr = { 3.14 X Diameter (mm) X RPM } / 1000 X PPR
Press SET
ENT key
9 9 9 9. 9 9 Set Diameter Value 2). For Manual Reset Mode, Set time = 00.0 sec &
Change by For Auto Reset Mode, Set time = 00.1 to 99.9 sec.
& Key d I a Range :- 0000.01
to 9999.99 mm 3). When Total Length = Set Length, Then Relay will energies ,
Press SET
ENT key
and remains ON till Set Auto Reset Time. Relay will turn off
after completion of time.
If time is set = 00.0 sec. then relay remains ON until key
Change by m e d I u m Set Speed Selection is pressed.
Key p u L S
Slow ( Max. RPM 500) 4). If there is a power failure, the last reading is stored in the
Press SET
ENT key Medium ( Max. RPM 5000) memory and Counter starts resume counting from the last
Fast ( Max. RPM 15000) stored value, when power ON.
Dia mm
Change by 9 9 9 9 Set PPR Selection Proximity
Key
P P R Pulse per revolution 4mm Distance
NOTE
Press SET
ENT key for save & exit 1). Please consult support engineers for sensing area size for
proxy to sense.
Note:
2). Please ensure proper sensing area size before installing
proxy sensor in your equipment.
Specifications are subject to change, since development is a continuous process,
So for more updated operating information and Support,
3). Sensing area must be equal or more than the proxy Please contact our Helpline: 9978991474/76/82 or
head size. Email at service@multispanindia.com Ver:2001013
Page 2