You are on page 1of 3

Printed on: 3/16/2023

Recommended Repairs Summary


Inspection ID : 4198

RR ID Component Name Defect Type Recommendations Approval Final Repair Acceptance


8036 Fitting Wall Loss Other Active Outstanding
Printed on: 3/16/2023

Recommended Repair Report


Equipment
Inspection ID: 4198
REACTOR GAS OR HIGH
Equipment Number: 020LN-10036CFD Equipment Description:
PRESSURE NITROGEN
Pipe Rack Code: Corrosion Loop:

Defects
Recommended Repair ID: 8036

Component: Fitting Specific Component:

NDT Method: RT Defect Location: Internal

Defect Type: Wall Loss Specific Defect:

Defect Section: CPS Number:

Findings
Wall Thickness:

Length: Width:

Height: Depth:

Findings Details: RT revealed internal wall loss of up to 40% of the 2" 45 degree elbow located at C65.

Recommendation
Critical Repair: Critical Inspector: Fourie, Charl (CF)

Inspector Approval: Engineering Type:

Engineering Required: Group Description: Synthol, CWU & EA

Hold Point Final Inspection: Approval Status: Active

Capture Date: 02/15/2023 Recommendation: Other

Recommendation Details: It is recommended to cut and replace the 2" elbow located at C65.

User Approval
Name: Buys, Manu (HC)

Acceptance: Approve

Comment: To be scheduled and executed


in the T-7 process. Repair in
accordance to applicable health
and safety standards.
Date: 02/16/2023

Recommended Repair ID: 8036 Page 1 of 2


Printed on: 3/16/2023

Final Approval
Final Approver:

Final Repair Acceptance: Outstanding

Final Repair Acceptance Date:

Final Repair Comment:

Inspection Signature:

Recommended Repair ID: 8036 Page 2 of 2