You are on page 1of 2

Tyfo® UC55­M Carbon Laminate Strips

DESCRIPTION STORAGE CONDITIONS SURFACE PREPARATION


®
Tyfo® UC55­M Carbon Laminate Strips are Store the Tyfo ® UC55­M Carbon Laminates The surface receiving the Tyfo UC55M Carbon
o
comprised of higher modulus & high tensile between 40 to 90o F (4o to 32o C) and epoxy Laminate Strip System must be sound and
strength, pull-formed, epoxy-carbon composite at 40 to 90 F (4o to 32o C). Avoid freezing.
o o
prepared for bonding by means of abrasive
strips adhered to the primed substrate with Store rolls flat, not on ends, at temperatures methods. Typically, light sandblasting, grinding
®
Tyfo® WS Epoxy, Tyfo TC­1 Epoxy, Tyfo® below 100o F (38o C). Avoid moisture and water or other approved methods are acceptable.
TC Epoxy or Tyfo® MB-3 Adhesive. contamination. The surface should be free of protrusions or
cavities. The Fyfe Co. LLC engineering
USE SAFETEY DATA SHEETS staff will provide the proper specifications and
For reinforcing of general building details based on the project requirements. Bond
construction, industrial buildings, parking
• Will be supplied upon request, complete
strength to substrate can be verified by ASTM
with state and federal packaging laws
struct ures, bridges and other structures D-4541.
with copy of labels used.
constructed of concrete, wood and steel.
• Material safety data sheets will be supplied MIXING
ADVANTAGES upon request. See Tyfo® epoxy data sheets for mix ratio and
• High tensile modulus and tensile mixing instructions.
strength properties HOW TO USE
• Good high temperature properties THE TYFO® UC 55­M CARBON APPLICATION
• Good low temperature properties LAMINATE STRIP SYSTEM Apply a prime coat of Tyfo® Epoxy to the
prepared substrate. Apply 1/16” (1.5mm) layer of
• Consistent material properties
Tyfo® Epoxy to the substrate prior to applying the
DESIGN
• Ease of installation
The Tyfo ® UC55­M Carbon Laminate System Tyfo® UC55­M Carbon Laminate Strip System.
• Pull-formed composites do not contain shall be designed to meet specific design criteria. Clean abraded side (side without lettering
releasing agents that affect material properties The criteria for each project is dictated by the and without glossy appearance) of Strip with
acetone or similar approved solvent to remove
• 100% epoxy matrix engineer of record and any relevant building
any foreign debris and let stand for 30 minutes
codes and/or guidelines. The design should
• Pre abraded for bonding
be based on the allowable strain for each type minimum to allow for evaporation of the solvent.
of application and the design modulus of the Apply 1/16” (1.5mm) minimum thickness layer
COVERAGE
material. The Fyfe Co. LLC engineering staff of Tyfo® epoxy adhesive to the cleaned side of
Surface coverage for the Tyfo® UC55­M Carbon
will provide preliminary design at no obligation. Strip. Allow sufficient time for the epoxy to reach
Laminate Strip System is dependent on the width
maximum tackiness. Apply the Strip within the
& length of roll ordered (see “Available Widths
for the Tyfo ® UC55­M Carbon Laminate Strips"). INSTALLATION specified cure time of the Tyfo® epoxy. The
The Tyfo® UC55­M Carbon Laminate System Tyfo® UC55­M Carbon Laminate Strip System
Strips”). One unit of Tyfo® WS Epoxy or Tyfo® TC­
shall be installed by Fyfe Co. LLC trained and to be applied uniformly, meeting specifications.
1 Epoxy will cover approximately 30 to 75 sq. ft.
certified applicators. Installation shall be in strict
(appr. 2.8 to 7m 2) of surface area at a thickness
compliance with the Fyfe Co. LLC quality control
of 1/16” (1.5mm). One unit of Tyfo® MB-3 Epoxy
procedures.
will cover approximately 10 - 25 sq. ft. (0.93 -
2.3m2) of surface area at 1/16” (1.5mm) thick.
The existing condition of the surface as well as TYPICAL DRY FIBER PROPERTIES
temperatures of both the epoxy and application Tensile Strength 711,000 psi (4.9 GPa)
surface will significantly affect the coverage
estimation. Tensile Modulus 33.4 x 106 psi (230 GPa)
Ultimate Elongation 2.1%
PACKAGING
The Tyfo ® UC55­M Carbon Laminate Strips are Density 0.065 lbs./in. (1.8 g/cm3)
3

available in various lengths. Standard rolls Volumetric Fiber Content 75%


in 328 foot lengths (100m) in individual boxes.
The rolls are coiled in boxes approximately 36”
(914mm) inside diameter. Typically ships in 40” x COMPOSITE GROSS LAMINATE PROPERTIES
40” x 6” (1016mm x 1016mm x 152mm) boxes. PROPERTY ASTM TYPICAL DESIGN VALUE*
Tyfo® epoxy pre-measured units ship in METHOD TEST VALUE
5-gallon (18.9L) containers. See Tyfo® epoxy
data sheets for more information. Ultimate tensile strength in D3039 435,120 psi 391,608 psi
primary fiber direction, psi (3.00 GPa) (2.70 GPa)
MIX RATIO
See Tyfo® epoxy data sheets for mix ratio Elongation at break D3039 1.8% 1.62%
information. Tensile Modulus, psi D3039 23.94 x 106 psi 21.55 x 10 6 psi
(165 GPa) (148.5 GPa)
SHELF LIFE
Epoxy - one year in original, unopened and Layer Thickness 0.055 in. (1.4 mm) 0.055 in. (1.4 mm)
properly stored containers. * Design and specification values will vary based on individual project requirements and applicable safety factors.
Strips - ten years in proper storage conditions. Contact Fyfe Co. LLC engineers to determine appropriate specification values.
** See “Available widths for the Tyfo® UC55­M Carbon Laminate Strips.”
09/19 Tyfo® UC55­M Strips
AVAILABLE WIDTHS FOR FIRST AID
THE TYFO ® UC55­M CARBON STRIPS CAUTION! In case of skin contact, wash thoroughly with
soap and water. For eye contact, flush
immediately with plenty of water; contact
Thickness: 0.055” (1.4mm) *
COMPONENT A - Irritant: physician immediately. For respiratory
Widths: 2” (50mm), 4” (100mm), 6" (150mm) *
Prolonged contact to the skin may cause problems, remove to fresh air. Wash clothing
irritation. Avoid eye contact. before reuse.
* Other thicknesses and widths are available.

DESIGNATIONS COMPONENT B - Irritant: CLEANUP


The Tyfo® UC55­M Carbon Laminate Strips are Corrosive. Contact with skin may cause severe Collect with absorbent material, flush with
are designated by the width and the thickness burns. Avoid eye contact. Product is a strong water. Dispose of in accordance with local
in inches. sensitizer. Use of safety goggles and chemical disposal regulations. Uncured material can be
resistant gloves recommended. Remove removed with approved solvent. Cured materials
Example: 2” wide and 0.055" thick laminate contaminated clothing. Avoid breathing vapors. can only be removed mechanically.
would be designated as “2UC55­M.” Use adequate ventilation. Use of an organic
vapor respirator recommended. SHIPPING LABELS CONTAIN•
Example: 4” wide and 0.055" thick laminate • Component designation / Name
would be designated as “4UC55­M.” LAMINATE PRECAUTIONS • Type, if applicable
Use caution when uncoiling roll. Use of an • Dimensions and weight
Example: 6” wide and 0.055" thick laminate approved particle mask is recommended for • Date of manufacture
possible airborne particles. Gloves are • Batch name
would be designated as “6UC55­M.”
recommended when handling strips to avoid • Lot number, if applicable
skin irritation. Safety glasses are recommended • Warnings or precautions required by law
to prevent eye irritation.
NOT FOR INTERNAL CONSUMPTION.
LIMITATIONS CONSULT MATERIAL SAFETY DATA SHEET
Application temperature of the epoxy is a
(MSDS) FOR MORE INFORMATION.
minimum 40o F (4o C) and maximum of 100o F
KEEP OUT OF REACH OF CHILDREN.
(38o C). DO NOT THIN, solvents will prevent
FOR INDUSTRIAL USE ONLY.
proper cure.

Contact: Aegion | Fyfe


Fyfe Co. LLC Fyfe Asia Pte Ltd
4995 Murphy Canyon Rd., Suite 110, San Diego, CA 92123 6 Clementi Loop, #02­20 (Level 4), Singapore 129814
Tel: 858.642.0694 Fax: 858.444.2982 Tel: +65.6898.5248 Fax: +65.6898.5181
E­mail: info@aegion.com Web: www.aegion.com E­mail: fyfeasia@aegion.com Web: www.fyfesia.com

Statement of Responsibility: The technical information and application advice in this publication is based on the present state of our best scientific and practical knowledge.
As the nature of the information herein is general, no assumption can be made as to the product’s suitability for a particular use or application, and no warranty as to its
accuracy, reliability or completeness, either expressed or implied, is given other than those required by State legislation. The owner, his representative or the contractor is
responsible for checking the suitability of products for their intended use. Field service, where provided, does not constitute supervisory responsibility. Suggestions made
by the Fyfe Co., either verbally or in writing, may be followed, modified or rejected by the owner, engineer or contractor since they, and not the Fyfe Co., are responsible
for carrying out procedure appropriate to a specific application.

09/19 Tyfo® UC55­M Strips Aegion®, Fyfe® and Tyfo® are registered trademarks of Aegion Corporation and its affiliates.

You might also like