Joint HSE Walk ZMDEI-Electrical Rigger Observed working with perfect ppe and
4 1/13/2020 Company Contractor Awareness/Behaviours Struck by/Hit by PO N/A Good practice, keep going. N/A 1/13/2020 Good practice. 0 Closed 1/13/2020
around Substation preperation.
No hand sanitizer nor hand wash soap Due to the COVID 19 restrictions, please provide
Company HSE 1. Hand sanitizer provided for office area
30 3/7/2020 Company Contractor Office area Health-Hygiene UC H available in the wash room & other site hand sanitizer and/or hand wash soap in all suitable N 3/7/2020 1 Closed 3/7/2020
Superv/inspection WC.
locations. locations of the work site
Company HSE ZMDEI-Electrical Broken wooden pieces not removed from the Broken wooden pieces removed from site and 1. Housekeeping has been conducted and
35 3/15/2020 Company Contractor Housekeeping Fall,Trip,Slip UC L N/A 3/15/2020 1 Closed 3/15/2020
Superv/inspection Substation site stacked properly. wooden pieces removed from the work site.
Security guards don’t have at disposition hand 1. Hand sanitizer / disinfection for security
Hand sanitizer / disinfection for security guard need
Company HSE ZMDEI-Electrical sanitizer/disinfectant, also necessary for guard has been provided also caravan and
51 7/27/2020 Company Contractor Health-Hygiene UA H to provide also caravan and surrounding cleaning is N 7/27/2020 1 Closed 7/27/2020
Superv/inspection Substation cleaning and disinfection of environmental surrounding cleaning is process on daily
mandatory at all time.
surfaces basis.
The human body temperature logbook is The log register format must be maintained in 1. The log register format is provided with
Company HSE ZMDEI-Electrical
52 7/27/2020 Company Contractor Covid19 management UA H registered in the Arabic language, while it English / Arabic language for recording the N 7/27/2020 English / Arabic language for recording the 1 Closed 7/27/2020
Superv/inspection Substation
should be registered in English also. temperature of all entants. temperature of all entants.
Observed a workman engaged to work with Advised to the concern workman to wear anti-
Contractor HSE ZMDEI-Electrical 1. Anti-vibration hand gloves has been
53 8/16/2020 Contractor Contractor PPE UA M manual compactor, with out wearing vibration hand gloves, while working with manual Y < 30 min 8/16/2020 1 Closed 8/16/2020
Superv/inspection Substation provided to the concern workman.
appropriate hand gloves. compactor.
Observed, Human body temperature
Contractor HSE ZMDEI-Electrical measurement and recording practice is
54 8/26/2020 Contractor Contractor Awareness/Behaviours PO N/A Good practice, appreciated. N/A 8/26/2020 Good practice. 0 Closed 8/26/2020
Superv/inspection Substation carrying out by security team at the entry point
of the site.
Contractor HSE ZMDEI-Electrical Observed workers are working with
55 9/6/2020 Contractor Contractor PPE PO N/A Good practice, appreciated. N/A 9/6/2020 Good practice. 0 Closed 9/6/2020
Superv/inspection Substation compliance PPE system.
Contractor HSE ZMDEI-Electrical It was observed that, sharp edged revars are
56 9/9/2020 Contractor Contractor Other (see comments) PO N/A Good practice, appreciated. N/A 9/9/2020 Good practice. 0 Closed 9/9/2020
Superv/inspection Substation covered with rebar cap.
Security guards didn’t measured the body Strictly instructed to security guards to measure all
Company HSE ZMDEI-Electrical 1. Security guard must measure the body
58 9/13/2020 Company Contractor Covid19 management UA H temperature of ENI staff, while they entered entrants body temperature while they entering into N/A 9/13/2020 1 Closed 9/13/2020
Superv/inspection Substation temperature of all entrants.
into project site. project site.
Observed an Electrical tool (grinder) was left at 1. TBT conducted to all workmen and
Company HSE ZMDEI-Electrical TBT conducted to all workmen and instructed safe
59 9/14/2020 Company Contractor Tools/Equipment Electrical Hazard UA H site in very hot weather condition (46 Cdeg) N 9/15/2020 instructed safe usage of portable electrical 1 Closed 9/15/2020
Superv/inspection Substation usage of portable electrical tools.
that can damage the tool. tools.
Advised to the concern supervising authority to 1. Barrication installed to the deep
Contractor HSE ZMDEI-Electrical It was observed that deep excavated area is
60 9/15/2020 Contractor Contractor Excavation/Trenching UC H provide proper barrication to prevent any N/A 9/15/2020 excavation to prevent from fall into 1 Closed 9/15/2020
Superv/inspection Substation not barricated properly.
accedental fall. excavation.
Contractor HSE ZMDEI-Electrical Observed material stacked properly and area
61 9/15/2020 Contractor Contractor Awareness/Behaviours PO N/A Good practice. N/A 9/15/2020 Good practice. 0 Closed 9/15/2020
Superv/inspection Substation barricated.
Hand disinfectant signage has posted and
Health & Hygiene
62 9/16/2020 Contractor Contractor Office area Health-Hygiene PO N/A alcohol based disinfectant available at the Good practice, appreciated. N/A 9/16/2020 Good practice. 0 Closed 9/16/2020
Insp.
entrance.
Observed Welface convinient maintained in
Health & Hygiene
63 9/16/2020 Contractor Contractor Office area Health-Hygiene PO N/A good hygeinic condition. Liquid soap available Good practice, appreciated. N/A 9/16/2020 Good practice. 0 Closed 9/16/2020
Insp.
near wash basin.
Health & Hygiene Waste bin provided to collect the generated Need to maintain neat and well at all time with safe
64 9/16/2020 Contractor Contractor Office area Health-Hygiene UC M N/A 9/16/2020 1. Collected waste has been disposed. 1 Closed 9/16/2020
Insp. waste, at office area. dispose of collected waste.
Health & Hygiene ZMDEI-Electrical 1. Need to dispose at the waste disposal
65 9/16/2020 Contractor Contractor Health-Hygiene UC M General waste accumilated at work site. Need to dispose at the waste disposal area. N/A 9/16/2020 1 Closed 9/16/2020
Insp. Substation area.
ZMDEI-Electrical Emergency Evacuation Procedure. Employees Need to contunue the same during any real
66 9/20/2020 Drill/Exercises Contractor Contractor Awareness/Behaviours PO N/A N/A 9/20/2020 Good practice. 0 Closed 9/20/2020
Substation react ontime after hearing emergency siren. emergency.
Company HSE ZMDEI-Electrical Poor housekeeping, hazard of tripping, Housekeeping conducted and instructed to the 1. Housekeeping conducted and instructed
73 9/23/2020 Company Contractor Housekeeping UC M N/A 9/24/2020 1 Closed 9/24/2020
Superv/inspection Substation unorganized storage. concern team to maintain the area neat and clean. to maintain the site clean and tidy.
Company HSE ZMDEI-Electrical Need to provide more Spill Kit needed for this Trash removed from inside the spill kit. More spill
74 9/23/2020 Company Contractor Health-Hygiene PO N/A N/A 9/23/2020 1. Spill kit has been provided. 0 Closed 9/23/2020
Superv/inspection Substation area, moreover the bin is being used for trash. kits will be provided immediately.
Joint HSE Walk ZMDEI-Electrical Main substation excavation provided with hard
75 9/23/2020 Joint Co/Cntr Contractor Excavation/Trenching PO N/A Good practice. N/A 9/23/2020 Good practice. 0 Closed 9/23/2020
around Substation barriers and means of warning signs.
Joint HSE Walk ZMDEI-Electrical Portable machineries and power tools found Inspection tag need to be placed on the portable 1. Inspection sticker placed on power tools
76 9/23/2020 Joint Co/Cntr Contractor Energized System Electrical Hazard UA H N 9/23/2020 1 Closed 9/23/2020
around Substation without inspection sticker / tag. machineries and electrical tools. after inspection.
1. Electrical cables routed through
Unprotected Live electrical cables were
Company HSE ZMDEI-Electrical underground. Cable sleeves provided for
77 9/24/2020 Company Contractor Energized System Electrical Hazard UC H observed left on the ground which could lead Electrical cables removed from the ground. N 9/24/2020 1 Closed 9/27/2020
Superv/inspection Substation live cables to prevent from any accidentally
to electrical hazards.
electrical hazards.
Adequate safety sign must posted near the
Company HSE ZMDEI-Electrical Adequate safety sign must posted near the work Adequate safety signages are provide near
78 9/24/2020 Company Contractor Safety signals/Barricades UA M work location ex. (deep excavation safety N/A 9/24/2020 1 Closed 9/28/2020
Superv/inspection Substation location ex. (deep excavation safety sign). work location.
sign).
1.Housekeeping conducted and trash
Contractor HSE ZMDEI-Electrical Poor housekeeping observed at main sub- Housekeeping conducted and trash removed from
79 9/27/2020 Contractor Contractor Housekeeping UC M N 9/28/2020 removed from main substation building 1 Closed 9/28/2020
Superv/inspection Substation station building area. main substation building area.
area.
Contractor HSE ZMDEI-Electrical Observed all excavations inside the main sub-
80 9/27/2020 Contractor Contractor Excavation/Trenching PO N/A Good practice. N/A 9/27/2020 Good practice. 0 Closed 9/27/2020
Superv/inspection Substation station building baricaed properly.
Poor housekeeping was observed after the
Company HSE ZMDEI-Electrical concrete pouring activity. Moreover, the Housekeeping need to conduct and removed all 1. Housekeeping conducted and instructed
81 9/28/2020 Company Contractor Housekeeping UC M N 9/28/2020 1 Closed 9/28/2020
Superv/inspection Substation formwork materials contained nails were left at unused formwork materials from the site. to maintain the site clean and tidy.
work site improperly .
Joint HSE Walk ZMDEI-Electrical Observed poor housekeeping at main sub- Housekeeping to be conducted and ensure the area 1. Housekeeping conducted and instructed
82 9/28/2020 Joint Co/Cntr Contractor Housekeeping UC M N 9/28/2020 1 Closed 9/28/2020
around Substation station building area. shall be clean and tidy. to maintain the site clean and tidy.
Company HSE ZMDEI-Electrical Un protected live electrical cable was observed Sleeves shall provided to protect the cable from any 1. The live electrical cable has been
103 10/14/2020 Company Contractor Energized System Electrical Hazard UC H N 10/15/2020 1 Closed 10/20/2020
Superv/inspection Substation at site that could lead to electrical hazard. damage. protected by provided sleeves.
Steel rebars were observed without a (safety 1. Rebar caps has been provided to the
Company HSE ZMDEI-Electrical
104 10/14/2020 Company Contractor Other (see comments) UC H cap) in the walkway that could lead to falling Rebar caps need to be provided for exposed rebars. N 10/15/2020 protrouded rebars to prevent from any 1 Closed 10/15/2020
Superv/inspection Substation
and injury hazards. accidental fall and injury.
Health & Hygiene
105 10/14/2020 Contractor Contractor Office area Health-Hygiene PO N/A Cool drinking water provided for workers at site. Good practice. N/A 10/14/2020 Good practice. 0 Closed 10/14/2020
Insp.
Health & Hygiene ZMDEI-Electrical Waste segregated by dedicative bins for the
106 10/14/2020 Contractor Contractor Health-Hygiene PO N/A Good practice. N/A 10/14/2020 Good practice. 0 Closed 10/14/2020
Insp. Substation generated waste.
Hand disinfectant signage has posted and
Health & Hygiene
107 10/14/2020 Contractor Contractor Office area Health-Hygiene PO N/A alcohol based disinfectant available inside the Good practice. N/A 10/14/2020 Good practice. 0 Closed 10/14/2020
Insp.
office.
Health & Hygiene Workers canteen observed neat and tidy.
108 10/14/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 10/14/2020 Good practice. 0 Closed 10/14/2020
Insp. Cleaning carryout on daily basis.
Company HSE ZMDEI-Electrical Worker was observed working at height TBT conducted and advised to workmen regarding 1. TBT conducted and advised to workmen
112 10/18/2020 Company Contractor Working at Height UA H Y < 30 min 10/18/2020 1 Closed 10/18/2020
Superv/inspection Substation without wearing safety harness. work at height requirements. regarding work at height requirements.
Health & Hygiene ZMDEI-Electrical Observed waste bin filled with general waste Need to dispose the waste and to continue on
128 10/21/2020 Contractor Contractor Housekeeping UC M N/A 10/21/2020 1. Waste has been disposed. 1 Closed 10/21/2020
Insp. Substation (drinking water pouch) and other items. regural basis.
Joint HSE Walk Observed means of barrication is missing at Barrication need to provide to prevent from any 1. Barrication has been provided to prevent
141 10/28/2020 Joint Co/Cntr Contractor Office area Excavation/Trenching UC M N 10/29/2020 1 Closed 10/29/2020
around temporary facilities / generator area. accidental fall of work men. from any accidental fall of work men.
Health & Hygiene Observed all workmen taking lunch inside the
143 10/29/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice, keept It up. N/A 10/29/2020 Good practice, keept It up. 0 Closed 10/29/2020
Insp. canteen and it is maintained neat & clean.
Access way was removed (the crew was instructed 1. Access way was removed (the crew was
Improper access was observed used to
Company HSE ZMDEI-Electrical don't use wooden planks as an access way) and instructed don't use wooden planks as an
154 11/5/2020 Company Contractor Access/Egress UC H entering concrete pouring working area that N 11/5/2020 1 Closed 11/5/2020
Superv/inspection Substation advised to provide safe means of access and access way) and advised to provide safe
could lead to falling hazard.
egress. means of access and egress.
Contractor HSE ZMDEI-Electrical Housekeeping need to implement to maintain Housekeeping need to implement to maintain the 1. Housekeeping has been implemented
188 11/21/2020 Contractor Contractor Housekeeping UC M N 11/21/2020 1 Closed 11/21/2020
Superv/inspection Substation the site tidy and free from trip hazards. site tidy and free from trip hazards. and will be conduct on daily basis.
Employee are working at height, while the Advised to the concern supervising authority to
Contractor HSE ZMDEI-Electrical 1. Sharp edged rebars has been covered by
189 11/21/2020 Contractor Contractor Other (see comments) UA H below section sharp edged rebars with out provide rebar caps or cover with wooden planks to Y < 30 min 11/21/2020 1 Closed 11/21/2020
Superv/inspection Substation wooden planks.
cover. the sharp edged rebars.
Instructed to the concern supervising authority to
Contractor HSE ZMDEI-Electrical Observed poor housekeeping (concrette 1. Housekeeping has been conducted and
190 11/22/2020 Contractor Contractor Housekeeping UC M conduct housekeeping and maintain the area clean N 11/22/2020 1 Closed 11/22/2020
Superv/inspection Substation waste) at transformer area. removed the waste from work area.
& tidy.
Scaffolder found working at height, with
Contractor HSE ZMDEI-Electrical
191 11/22/2020 Contractor Contractor Working at Height PO N/A complying all safety pre-cautions like wearing Good practice. N/A 11/22/2020 Good practice. 0 Closed 11/22/2020
Superv/inspection Substation
safety harness with 100% tieoff.
Contractor HSE ZMDEI-Electrical Observed planks are missing on a scaffold Instructed to the scaffolding team to remove the tag 1. Scaffolding has been rectified and green
200 11/28/2020 Contractor Contractor Scaffolds/Ladders UC H Y < 1h 11/28/2020 1 Closed 11/28/2020
Superv/inspection Substation platform, while is in green tag. and then rectify it and place the tag after inspection. tag placed after re-inspection.
Contractor HSE ZMDEI-Electrical Concrette waste is accumilated, at main Instructed to the concern supervising authority to 1. Housekeeping conducted and removed
201 11/28/2020 Contractor Contractor Housekeeping UC M N 11/28/2020 1 Closed 11/29/2020
Superv/inspection Substation substation area. remove the waste and dispose accordingly. the concrette.
Contractor HSE ZMDEI-Electrical Observed concrette debris scatered at outside Instructed to the concern supervising authority to 1. Housekeeping conducted and removed
202 11/29/2020 Contractor Contractor Housekeeping UC M N 11/29/2020 1 Closed 11/29/2020
Superv/inspection Substation cable trench. collect the concrette waste and dispose accordingly. the concrette.
Contractor HSE ZMDEI-Electrical Electrical panels are covered with plastic cover
203 11/29/2020 Contractor Contractor Energized System Electrical Hazard PO N/A Good practice. N/A 11/29/2020 Good practice. 0 Closed 11/29/2020
Superv/inspection Substation to protect from rain water.
Both the lifting equipment (Crane ) and lifting 1. Inspection conducted to the lifting
Color coding inspection (tagging system or color
gears were observed without inspection color equipment and accessories and color
Company HSE ZMDEI-Electrical system) must be used For all lifting equipment and
204 12/2/2020 Company Contractor Lifting UA H coding while being used for lifting activity Y < 1h 12/2/2020 coded. 2 Closed 12/2/2020
Superv/inspection Substation lifting gears. Conducting Daily inspection checklist
moreover, it was no inspection daily checklist 2. Daily checklist has been
for crane.
for the crane. implemented.
Health & Hygiene
205 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A WC floor is cleaning on daily basis. Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp.
Health & Hygiene
206 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A Domestic waste is disposing on daily basis. Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp.
Health & Hygiene Site clinic is maintained in well neat and
207 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp. hygienic condition.
Health & Hygiene Site clinic is maintained in well neat and
208 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp. hygienic condition.
Health and hygienic and COVID-19
Health & Hygiene
209 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A precautions signages are posted at the Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp.
entrance of company (ENI) office.
Health & Hygiene
210 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A Hand wash liquid soap is available at toilet. Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp.
Health & Hygiene Portable waste-bin provided outside the
211 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp. COMPANY office
Health & Hygiene Portable waste-bin provided outside the ABG
212 12/2/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/2/2020 Good practice. 0 Closed 12/2/2020
Insp. office.
Joint HSE Walk ZMDEI-Electrical Workers are wearing full body safety harness
213 12/3/2020 Joint Co/Cntr Contractor Awareness/Behaviours PO N/A Good practice. N/A 12/3/2020 Good practice. 0 Closed 12/3/2020
around Substation with 100% tie off, while working at height.
Joint HSE Walk ZMDEI-Electrical Un-used barrication materials need to remove 1. Un-used barrication materials has been
214 12/3/2020 Joint Co/Cntr Contractor Housekeeping UC L Need to remove it from work site. N 12/3/2020 1 Closed 12/3/2020
around Substation from work area. removed from work site.
Joint HSE Walk ZMDEI-Electrical Hard barricade to be installed to prevent from Hard barricade shall be provided to the excavation 1. Hard barricade provided to the
215 12/3/2020 Joint Co/Cntr Contractor Excavation/Trenching UC H N 12/3/2020 1 Closed 12/3/2020
around Substation fall into deep excavation to prevent from fall. excavation to prevent from fall.
Joint HSE Walk ZMDEI-Electrical Waste debris need to be removed from work Housekeeping shall be conducted to maintain the 1. Housekeeping has been conducted to
216 12/3/2020 Joint Co/Cntr Contractor Housekeeping UC M N 12/3/2020 1 Closed 12/3/2020
around Substation area. area clean and tidy. maintain the area clean and tidy.
Joint HSE Walk ZMDEI-Electrical Un-wanted wooden timbers need to remove Un-wanted wooden timbers are remove from work 1. Un-wanted wooden timbers are removed
217 12/3/2020 Joint Co/Cntr Contractor Housekeeping UC M N 12/3/2020 1 Closed 12/3/2020
around Substation from work area. site. from work site.
Joint HSE Walk ZMDEI-Electrical Waste bin is full of waste, need to dispose the
218 12/3/2020 Joint Co/Cntr Contractor Housekeeping UC M Waste shall be disposed at waste storate area. N 12/3/2020 1. Waste disposed at waste storate area. 1 Closed 12/3/2020
around Substation waste.
Joint HSE Walk Means of hygienic condition need to maintain Means of good hygienic shall be maintained at 1. Means of good hygienic is maintained at
219 12/3/2020 Joint Co/Cntr Contractor Office area Health-Hygiene UC M N 12/3/2020 1 Closed 12/3/2020
around at security caravin area. security area. security area.
1. Shuttering materials are removed from
Joint HSE Walk Cable trench (Out Shuttering materials found scattered at cable Shuttering materials to be removed from access &
220 12/3/2020 Joint Co/Cntr Contractor Housekeeping UC M N 12/3/2020 access & egress and segregated 1 Closed 12/3/2020
around side) trench area. egress and segregated accordingly.
accordingly.
Joint HSE Walk Cable trench (Out Hard barrication shall be installed at cable trench to 1. Hard barrication is installed at cable
221 12/3/2020 Joint Co/Cntr Contractor Excavation/Trenching UC H Barrication missing at cable trench area. N 12/3/2020 1 Closed 12/3/2020
around side) prevent from fall. trench to prevent from fall.
Joint HSE Walk Cable trench (Out Circular saw found unattended and operating Circular saw shall be reomoved from ground and 1. Circular saw has been removed from
222 12/3/2020 Joint Co/Cntr Contractor Tools/Equipment UA H N 12/3/2020 1 Closed 12/3/2020
around side) on the ground. instructed to use at work shop. ground and instructed to use at work shop.
Contractor HSE Cable trench (Out Observed barrication missing at cable trench Advised to install the barrication to prevent from fall 1. Barrication has been provided to prevent
224 12/6/2020 Contractor Contractor Excavation/Trenching UC H N 12/6/2020 1 Closed 12/6/2020
Superv/inspection side) excavation. into excavation. from any accidental fall of work men.
Company HSE ZMDEI-Electrical Access to scaffold is obstructed, in case of 1. Alternative access has been provided to
225 12/8/2020 Company Contractor Scaffolds/Ladders UC H Consider to provide alternative access. N 12/8/2020 1 Closed 12/8/2020
Superv/inspection Substation emergency rescue. respond during any emergency.
Company HSE ZMDEI-Electrical 1. Steps are provided to access the work
226 12/8/2020 Company Contractor Access/Egress UC H Improve access to confined space. Replace ladder with steps. N 12/8/2020 1 Closed 12/8/2020
Superv/inspection Substation place.
Joint HSE Walk ZMDEI-Electrical Damaged tools posted at the entrance of the
227 12/8/2020 Joint Co/Cntr Contractor Awareness/Behaviours PO N/A Good practice. N/A 12/8/2020 Good practice. 0 Closed 12/8/2020
around Substation site, to display as not to use.
Access towards to the main substation is
Joint HSE Walk ZMDEI-Electrical
228 12/8/2020 Joint Co/Cntr Contractor Access/Egress PO N/A provided by scaffold planks and it is safe to Good practice. N/A 12/8/2020 Good practice. 0 Closed 12/8/2020
around Substation
use.
Joint HSE Walk ZMDEI-Electrical Access towards firewall is blocked by Need to provide means of safe access and egress 1. Means of safe access & egress is
229 12/8/2020 Joint Co/Cntr Contractor Access/Egress UC H N 12/8/2020 1 Closed 12/8/2020
around Substation supporting form materials. to the work place. provided for the firewall .
Some workers found wearing gum boots at
Joint HSE Walk ZMDEI-Electrical 1. Safety shoe has been issued to the
230 12/8/2020 Joint Co/Cntr Contractor PPE UA H work site, but it is designed only to work inside Suggested to change the shoe and wear safety shoe. Y < 30 min 12/8/2020 1 Closed 12/8/2020
around Substation concern workmen.
the water or concrete.
Contractor HSE ZMDEI-Electrical Access towards firewall is blocked by Instructed to the concern supervising authority to 1. Supporting materials has been removed
232 12/9/2020 Contractor Contractor Access/Egress UC H N 12/9/2020 1 Closed 12/12/2020
Superv/inspection Substation supporting form materials. provide alternative access to the firewall. from the firewall access.
Company HSE ZMDEI-Electrical Housekeeping conducted at material storage 1. Housekeeping conducted at material
233 12/10/2020 Company Contractor Housekeeping UC M Poor housekeeping on storage materials area. N 12/12/2020 1 Closed 12/12/2020
Superv/inspection Substation accordingly. storage accordingly.
The flag-man must be better indoctrinated, this Re-training conducted to the concern flagman and 1. Re-training conducted to the concern
Company HSE ZMDEI-Electrical Vehicle/Machinery
234 12/10/2020 Company Contractor Struck by/Hit by UA H morning we noticed that he doesn't respect advised to maintain safe distance from the Y < 30 min 12/12/2020 flagman and advised to maintain safe 1 Closed 12/12/2020
Superv/inspection Substation Movement
always the safety distance from vehicles. equipment. distance from the equipment.
Basket material homemade, It has been Homemade baskets are not allowed and instructed
Company HSE ZMDEI-Electrical 1. Homemade baskets are not allowed and
235 12/10/2020 Company Contractor Other (see comments) UC H pointed out that this type of equipment is to the involving personnel to donot use it and N/A 12/12/2020 1 Closed 12/12/2020
Superv/inspection Substation removed from work site.
strictly forbidden. removed from work site.
Missing safety signs out of the Generators
Company HSE 1. Means of safety signs placed at
236 12/10/2020 Company Contractor Office area Safety signals/Barricades UA M area. Moreover, the present one are Means of safety signs placed at generator area. N/A 12/12/2020 1 Closed 12/12/2020
Superv/inspection generator area.
unrecognizable.
Homemade connection between generator and
Company HSE Any deviation from the routine plan must be 1. Generator has been switched off, and
237 12/10/2020 Company Contractor Office area Energized System Electrical Hazard UC H external batteries without any precaution and N 12/12/2020 1 Closed 12/12/2020
Superv/inspection reported and notice to be apply. instructed to no to use.
notice posted in place.
Company HSE Uncertified and damage ladder used inside to The damaged ladder has been removed from 1. The damaged ladder has been removed
238 12/10/2020 Company Contractor Office area Scaffolds/Ladders UC H N/A 12/12/2020 1 Closed 12/12/2020
Superv/inspection the power generators area. service. from service.
Portable empty extinguisher found close to the
Company HSE The fire extinguisher is in good condition, and 1. The fire extinguisher is in good condition,
239 12/10/2020 Company Contractor Office area Other (see comments) UC H fuel tank. The area around not free, presence N/A 12/12/2020 1 Closed 12/12/2020
Superv/inspection placed at a safe place. and placed at a safe place.
of various materials.
Missing containment skid under the fuel tank.
Containment skid shall be provided to isolate the 1. Containment skid has been provided to
Company HSE Presence of empty cans and various hoses.
240 12/10/2020 Company Contractor Office area Chemical products UC H fuel during accedental release. Safety signs are N/A 12/24/2020 isolate the fuel during accedental release. 1 Closed 1/5/2021
Superv/inspection Missing safety signs, name – total capacity on
placed. Safety signs are placed.
the water tanks.
Health & Hygiene Waste storage area is maintained clean and
241 12/10/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/10/2020 Good practice. 0 Closed 12/10/2020
Insp. tidy.
Health & Hygiene
242 12/10/2020 Contractor Contractor Office area Health-Hygiene PO N/A Hand sanitizer is available at TOZZI office area. Good practice. N/A 12/10/2020 Good practice. 0 Closed 12/10/2020
Insp.
Health & Hygiene Hand sanitizer signage is available at
243 12/10/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/10/2020 Good practice. 0 Closed 12/10/2020
Insp. COMPANY WC.
Health & Hygiene
244 12/10/2020 Contractor Contractor Office area Health-Hygiene PO N/A Daily cleaning is conducting at COMPANY WC. Good practice. N/A 12/10/2020 Good practice. 0 Closed 12/10/2020
Insp.
Health & Hygiene Hand sanitizer and signage is available at
245 12/10/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/10/2020 Good practice. 0 Closed 12/10/2020
Insp. COMPANY WC.
Hand sanitizer and awareness signage is
Health & Hygiene
246 12/10/2020 Contractor Contractor Office area Health-Hygiene PO N/A available at the entrance of the COMPANY Good practice. N/A 12/10/2020 Good practice. 0 Closed 12/10/2020
Insp.
office.
Health & Hygiene Observed workers rest area is maintained
247 12/10/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/10/2020 Good practice. 0 Closed 12/10/2020
Insp. clean and tidy.
Poor housekeeping and materials were left at Instructed to the concern supervising authority to
Company HSE Cable trench (Out 1. Housekeeping has been conducted and
248 12/13/2020 Company Contractor Housekeeping UC M site improperly inside and out side the trench remove all unused materials and conducting all N 12/13/2020 1 Closed 12/15/2020
Superv/inspection side) all unused materials removed from site.
may lead to tripping/falling hazards. area housekeeping.
Workers were observed working at height on Immediatelly call them down, TBT conducted and
Company HSE Cable trench (Out 1. TBT conducted and advised to workmen
249 12/13/2020 Company Contractor Working at Height Fall,Trip,Slip UA H uninspected the scaffold (contend red tag) that advised to wear full body safety harness while Y < 30 min 12/13/2020 1 Closed 12/13/2020
Superv/inspection side) regarding work at height requirements.
which may lead to falling hazards. working at height.
Company HSE Cable trench (Out Uninspected Scaffolding has been used by Immediatelly call them down, TBT conducted and 1. Inspection has been conducted to the
250 12/13/2020 Company Contractor Scaffolds/Ladders UC H Y < 30 min 12/13/2020 1 Closed 12/13/2020
Superv/inspection side) worker that which may lead to falling hazards. briefed about working on scaffolding requirements. scaffold by inspector and green tag placed.
Chemical materials (painting cans) was 1. Chemicals has been transferred to ABG
Company HSE ZMDEI-Electrical Instructed to transferred to a warehouse designated
251 12/13/2020 Company Contractor Chemical products UC H observed stored improper way with other N 12/14/2020 main store and stored with proper 1 Closed 12/14/2020
Superv/inspection Substation for storing chemicals that contains ventilation
materials moreover area was not ventilated ventilation.
Poor housekeeping and materials was left 1. Housekeeping has been conducted and
Company HSE ZMDEI-Electrical improperly at storage area moreover, damaged Instructed to transferred to a warehouse designated materials are organized accordingly.
253 12/13/2020 Company Contractor Housekeeping Fall,Trip,Slip UC H N 12/14/2020 1 Closed 12/14/2020
Superv/inspection Substation and uninspected equipment's was observed at for storing chemicals that contains ventilation Damaged equipment's are kept aside and
same area. instructed to remove from project site.
Contractor HSE Cable trench (Out Poor housekeeping observed at out side cable Need to conduct housekeeping to maintain the area 1. Housekeeping has been conducted and
281 12/22/2020 Contractor Contractor Housekeeping UC M N/A 12/23/2020 1 Closed 12/23/2020
Superv/inspection side) trench area. clean & tidy. instructed to maintain the area clean & tidy.
Cable trench (Out HSE Dept has trained to workers about how to
283 12/22/2020 Drill/Exercises Contractor Contractor Awareness/Behaviours PO N/A Good practice. N/A 12/22/2020 Good practice. 0 Closed 12/22/2020
side) extinguish a fire.
1. Need to inform to the incident
Cable trench (Out Need to inform to the incident commander about
284 12/22/2020 Drill/Exercises Contractor Contractor Awareness/Behaviours UA H No communication to the incident commander. N/A 12/22/2020 commander about the scenario or in a real 1 Closed 12/22/2020
side) the scenario or in a real emergency.
emergency.
Lifting operation is carrying out with
Contractor HSE ZMDEI-Electrical compliance to all safety precautions like, lifting
285 12/24/2020 Contractor Contractor Awareness/Behaviours PO N/A Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Superv/inspection Substation supervisor, rigger and barrication of the lifting
zone.
Contractor HSE ZMDEI-Electrical
286 12/24/2020 Contractor Contractor Housekeeping PO N/A 21 Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Superv/inspection Substation
Health & Hygiene
287 12/24/2020 Contractor Contractor Office area Housekeeping UC M Observed waste-bin is filled with waste. Need to dispose the waste on regular basis. N/A 12/24/2020 1. Waste has been disposed. 1 Closed 12/24/2020
Insp.
Health & Hygiene
288 12/24/2020 Contractor Contractor Office area Housekeeping PO N/A Waste-bin provided in-front of security caravan. Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp.
Health & Hygiene
289 12/24/2020 Contractor Contractor Office area Health-Hygiene PO N/A Workers mess hall maintained neat and clean. Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp.
Health & Hygiene C0VID-19 precautions signages has been
290 12/24/2020 Contractor Contractor Office area Awareness/Behaviours PO N/A Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp. placed inside the workers mess hall.
Health & Hygiene
291 12/24/2020 Contractor Contractor Office area Health-Hygiene PO N/A Waste-bin is provided at TOZZI camp. Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp.
Health & Hygiene
292 12/24/2020 Contractor Contractor Office area Health-Hygiene PO N/A Hand wash liquid is available at ABG WC. Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp.
Health & Hygiene
293 12/24/2020 Contractor Contractor Office area Health-Hygiene PO N/A Observed waste-bin is in hygienic condition. Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp.
Health & Hygiene
294 12/24/2020 Contractor Contractor Office area Health-Hygiene PO N/A Observed hand wash is provided at ABG WC. Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp.
Health & Hygiene Hand dis-infectant signage has been posted at
295 12/24/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
Insp. ABG WC.
Joint HSE Walk ZMDEI-Electrical Observed workmen working at height with
296 12/24/2020 Joint Co/Cntr Contractor Working at Height PO N/A Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
around Substation compliance 100% tie off.
Joint HSE Walk ZMDEI-Electrical Power tools are found is in good condition with
297 12/24/2020 Joint Co/Cntr Contractor Tools/Equipment PO N/A Good practice. N/A 12/24/2020 Good practice. 0 Closed 12/24/2020
around Substation quarterly inspected and tag provided.
Joint HSE Walk ZMDEI-Electrical Need to place the manufacturer label for 1. Manufacturer label has been displayed
298 12/24/2020 Joint Co/Cntr Contractor Tools/Equipment UC H Safety harness missing the manufacturer label. Y < 30 min 12/24/2020 1 Closed 12/24/2020
around Substation identification. on safety harness.
Joint HSE Walk ZMDEI-Electrical Sharp edged rebars found at the access to Need to provide barrication and rebar caps to the 1. Barrication has been installed and rebar
299 12/24/2020 Joint Co/Cntr Contractor Other (see comments) UC H N/A 12/25/2020 1 Closed 12/25/2020
around Substation main sub-station. exposed rebars. caps provided to the exposed rebars.
Joint HSE Walk ZMDEI-Electrical Observed barrication missing at the main- Need to provide means barrication to prevent from Barriers are installed and marked with
300 12/24/2020 Joint Co/Cntr Contractor Safety signals/Barricades UC M N 12/24/2020 1 Closed 12/24/2020
around Substation substation wall opening. any accedental fall. warning tape and safety signs
Joint HSE Walk ZMDEI-Electrical Observed windsocks is damaged and not
301 12/24/2020 Joint Co/Cntr Contractor Other (see comments) UC H Need to change the windsocks ASAP. N/A 12/24/2020 The windsocks has been replaced 1 Closed 4/7/2021
around Substation indication the correct direction.
Joint HSE Walk 1. Cover has been provided to the septic
302 12/24/2020 Joint Co/Cntr Contractor Office area Safety signals/Barricades Fall,Trip,Slip UC H Cover missing on the septic tank at TCF. Need to provide the cover to the septic tank opening. N/A 12/24/2020 1 Closed 12/30/2020
around tank.
Joint HSE Walk ZMDEI-Electrical Observed sharp edged rebar with out 1. Rebar caps has been provided to the
303 12/24/2020 Joint Co/Cntr Contractor Other (see comments) UC H Need to barricade the area and provide the cap. N/A 12/24/2020 1 Closed 12/25/2020
around Substation protection and barricade. sharp edged rebars.
Joint HSE Walk Observed access step is missing at workers Need to provide steps or safe means of access to 1. Means of access steps has been
304 12/24/2020 Joint Co/Cntr Contractor Office area Access/Egress UC M N 12/27/2020 1 Closed 1/4/2021
around WC. the workers WC. provided at workers WC.
Contractor HSE Cable trench (Out Observed poor housekeeping at outside cable 1. Housekeeping conducted and maintained
305 12/26/2020 Contractor Contractor Housekeeping UC M Housekeeping shall be conducted on daily basis. N 12/26/2020 1 Closed 12/26/2020
Superv/inspection side) trench. the work area clean & tidy.
Contractor HSE Cable trench (Out Electrical panel found open at cable trench Electrical panels must be locked to prevent from 1. Electrical panel has been locked to
306 12/26/2020 Contractor Contractor Energized System Electrical Hazard UC H Y < 30 min 12/26/2020 1 Closed 12/26/2020
Superv/inspection side) area. any electrical hazards. prevent from any electrical hazards.
Contractor HSE ZMDEI-Electrical Observed means of safety signs for awareness
307 12/27/2020 Contractor Contractor Awareness/Behaviours PO N/A Good practice. N/A 12/27/2020 Good practice. 0 Closed 12/27/2020
Superv/inspection Substation has been
Company HSE ZMDEI-Electrical Formwork was observed have nails left on the Unwanted wooden timbers shall be removed from 1. Unwanted timber woods has been
312 12/27/2020 Company Contractor Housekeeping UC M N/A 12/27/2020 1 Closed 12/29/2020
Superv/inspection Substation ground while workers pass throw that area. access area. removed from access area.
Joint HSE Walk ZMDEI-Electrical Workers are complying with masks during work
313 12/30/2020 Joint Co/Cntr Contractor Awareness/Behaviours PO N/A Good practice, keep it up. N/A 12/30/2020 Good practice. 0 Closed 12/30/2020
around Substation to comply with COVID-19 requirements.
Joint HSE Walk ZMDEI-Electrical Access steps is not available towards Access steps shall be provided to the transformer
314 12/30/2020 Joint Co/Cntr Contractor Access/Egress UC M N/A 1/1/2021 That area has been backfilled . 1 Closed 1/14/2021
around Substation transformer foundation. foundation.
Joint HSE Walk ZMDEI-Electrical Observed timber woods with protruded nails at Need to de-nail or bend the nails after dismantling 1. Protruded nails has been bent
315 12/30/2020 Joint Co/Cntr Contractor Other (see comments) UC H N/A 12/30/2020 1 Closed 12/30/2020
around Substation work site. form work. immediately.
Observed electrical cable extension is not
Joint HSE Walk ZMDEI-Electrical 1. Electrical cables has been maintained
316 12/30/2020 Joint Co/Cntr Contractor Energized System Electrical Hazard UC H maintained safe clearance (2 mtr)from ground, Need to maintain safe clearance from ground 2 mtr. N 12/30/2020 1 Closed 12/30/2020
around Substation safe clearance 2 mtr from the ground.
while routed to workplace.
Health & Hygiene Workers mess hall maintained in good hygienic
317 12/31/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice, need to continue. N/A 12/31/2020 Good practice. 0 Closed 12/31/2020
Insp. condition.
Health & Hygiene Hand dis-infectant signages has been posted
318 12/31/2020 Contractor Contractor Office area Health-Hygiene PO N/A COVID-19 Precautions, Good practice. N/A 12/31/2020 Good practice. 0 Closed 12/31/2020
Insp. at office entrance.
Health & Hygiene
319 12/31/2020 Contractor Contractor Office area Health-Hygiene PO N/A Site clinic is in good hygienic condition. Good practice, need to continue. N/A 12/31/2020 Good practice. 0 Closed 12/31/2020
Insp.
Health & Hygiene
320 12/31/2020 Contractor Contractor Office area Health-Hygiene PO N/A Workers WC is cleaning on daily basis. Need to continue. N/A 12/31/2020 Good practice 0 Closed 12/31/2020
Insp.
1. Daily generated waste is being disposed
Portable waste bin is provided outside
Health & Hygiene on daily basis.
321 12/31/2020 Contractor Contractor Office area Health-Hygiene PO N/A COMPANY Office and maintained in good Need to dispose the waste on daily bais. N/A 12/31/2020 0 Closed 12/31/2020
Insp. 2. One dedicative cleaner has been
hygienic condition.
deployeed to carry out this task.
Health & Hygiene Liquid Hand wash soap and dis-infectant
322 12/31/2020 Contractor Contractor Office area Health-Hygiene PO N/A Need to refill the liquid soap on regular basis. N/A 12/31/2020 Good practice. 0 Closed 12/31/2020
Insp. signages is posted at COMPANY WC.
Health & Hygiene Portable waste bin is provided at out side
323 12/31/2020 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 12/31/2020 Good practice. 0 Closed 12/31/2020
Insp. security caravan.
Contractor HSE ZMDEI-Electrical Poor housekeeping onbserved at main Need to conduct housekeeping to maintain the area 1. Housekeeping has been conducted and
324 1/2/2021 Contractor Contractor Housekeeping Fall,Trip,Slip UC M N/A 1/3/2021 1 Closed 1/4/2021
Superv/inspection Substation substation building. clean & tidy. maintained the area clean & tidy.
Contractor HSE ZMDEI-Electrical Access towards security guard tower is Need to remove the hard barrier and provide 1. Hard barrier has been removed from
325 1/2/2021 Contractor Contractor Access/Egress Fall,Trip,Slip UC H N/A 1/2/2021 1 Closed 1/2/2021
Superv/inspection Substation obstructed by hard barrier. access to guard tower. access area.
Observed some workmen installing the form 1. Immediatelly stop the job.
Contractor HSE ZMDEI-Electrical
326 1/3/2021 Contractor Contractor Working at Height Fall,Trip,Slip UA H work by standing on rebars, which may lead to Need to use scaffold platform to work at height. Y < 30 min 1/3/2021 2. Advised to use the scaffold 2 Closed 1/3/2021
Superv/inspection Substation
fall from height and injury to personnel. platform to work at height.
Contractor HSE ZMDEI-Electrical Observed sharp edged rebars are with out Need tp provide rebar caps to the sharp edged 1. Rebar caps has been provided to the
327 1/3/2021 Contractor Contractor Other (see comments) Fall,Trip,Slip UC H N/A 1/3/2021 1 Closed 1/3/2021
Superv/inspection Substation protective caps. rebars. sharp edged rebars.
Company HSE ZMDEI-Electrical TOZZI \Albilal emergency response number is 1. Emergency contact has been updated
328 1/3/2021 Company Contractor Awareness/Behaviours Other (see comments) UA H Emergency contact must be in place ASAP. N/A 1/3/2021 1 Closed 1/7/2021
Superv/inspection Substation switched off (un reachable). and communicated with COMPANY.
Company HSE ZMDEI-Electrical Steel rebar at site with out covering or 1. Rebar caps has been provided to the
329 1/3/2021 Company Contractor Other (see comments) Fall,Trip,Slip UC H Rebar caps shall be provided to the exposed rebars. N 1/3/2021 1 Closed 1/3/2021
Superv/inspection Substation barrication sharp edged rebars.
The area inside the substation was conducted
Company HSE ZMDEI-Electrical
330 1/4/2021 Company Contractor Housekeeping Fall,Trip,Slip PO N/A a good housekeeping and all open electrical Good practice. N/A 1/4/2021 Good practice. 0 Closed 1/4/2021
Superv/inspection Substation
pits are closed.
Deep cables trench were observed without
Company HSE ZMDEI-Electrical cover or barricading while workers passing Need to install barricade and cover the hole to 1. Holes has been covered and barricade
331 1/4/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC H N 1/4/2021 1 Closed 1/4/2021
Superv/inspection Substation through that area that may lead to a falling prevent from fall into excavation. provided.
hazard.
Waste segregation is on-going and will be
Waste segregation area was observed in poor
the waste at waste segregation area must be a removed soon.
Company HSE ZMDEI-Electrical condition waste was mixed There is no
332 1/4/2021 Company Contractor Housekeeping Fall,Trip,Slip UC M separation from each other according to the nature N/A 1/4/2021 the waste at waste segregation area must 1 Closed 1/14/2021
Superv/inspection Substation separation of waste moreover Safety signs are
of waste. be a separation from each other according
missing in that area
to the nature of waste.
Inside the transformers, the area was observed
Company HSE ZMDEI-Electrical not barricaded properly and there was no Hard barricade shall be installed at transformer 1. Hard barricade has been installed at
333 1/4/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC H N/A 1/4/2021 1 Closed 1/5/2021
Superv/inspection Substation access way to reach to another side moreover area, to prevent from fall. transformer area.
it was in poor housekeeping.
Company HSE ZMDEI-Electrical The safety harness left on the ground ,poor Safety harness shall be stored properly by installed 1. Safety harness has been stored properly
334 1/5/2021 Company Contractor Awareness/Behaviours Other (see comments) UA M N/A 1/5/2021 1 Closed 1/5/2021
Superv/inspection Substation storage condition hangers. by installed hangers.
1. Work at height training conducted to the
concern workman on work at height
Company HSE ZMDEI-Electrical The worker, worked without platform climbing Need to provide training to the concern violator on
335 1/5/2021 Company Contractor Working at Height Fall from height UA H Y < 30 min 1/5/2021 practices. 2 Closed 1/5/2021
Superv/inspection Substation over the pillar work at height practices.
2. Platform provided to work
at height.
1. Barrication has been installed.
Inside , the area was observed not barricaded
Company HSE ZMDEI-Electrical Barrication shall be provided and housekeeping to 2. Housekeeping has been
336 1/5/2021 Company Contractor Housekeeping Fall,Trip,Slip UC M properly and moreover it was in poor N 1/5/2021 2 Closed 1/5/2021
Superv/inspection Substation be conducted. conducted and maintained the area clean &
housekeeping.
tidy.
Company HSE ZMDEI-Electrical There is a narrow way to enter the Access shall be widen to provide safe access & 1. Means of access & egress has been
337 1/5/2021 Company Contractor Access/Egress UC M N/A 1/5/2021 1 Closed 1/6/2021
Superv/inspection Substation watchtower , must widen the way. egress. provided to enter to watch tower.
Company HSE ZMDEI-Electrical Inside the area was observed poor Housekeeping shall be conducted to maintain the 1. Housekeeping has been conducted and
338 1/5/2021 Company Contractor Housekeeping UC M N 1/5/2021 1 Closed 1/6/2021
Superv/inspection Substation housekeeping. area clean and tidy. maintained the area clean & tidy.
Health & Hygiene liquid hand wash is provided at TOZZI Camp
339 1/6/2021 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 1/6/2021 Good practice. 0 Closed 1/6/2021
Insp. WC.
Health & Hygiene Security caravan is maintained in good
340 1/6/2021 Contractor Contractor Office area Health-Hygiene PO N/A Good practice. N/A 1/6/2021 Good practice. 0 Closed 1/6/2021
Insp. hygienic condition.
Health & Hygiene
341 1/6/2021 Contractor Contractor Office area Health-Hygiene PO N/A Portable waste bin is provided at office area. Good practice. N/A 1/6/2021 Good practice. 0 Closed 1/6/2021
Insp.
Health & Hygiene Clinic is maintained in good hygienic condition, Need to dispose the clinic waste with consider to
342 1/6/2021 Contractor Contractor Office area Health-Hygiene PO N/A N/A 1/6/2021 Good practice. 0 Closed 1/6/2021
Insp. clinical waste is disposed in dedicative bin environment.
Health & Hygiene ZMDEI-Electrical COVID-19 posters has been posted inside
368 1/20/2021 Contractor Contractor Health-Hygiene PO N/A Keep going. N/A 1/20/2021 Good practice 0 Closed 1/20/2021
Insp. Substation Administrator Office.
Health & Hygiene ZMDEI-Electrical It is observed that portable waste is provided at
369 1/20/2021 Contractor Contractor Health-Hygiene PO N/A parking area is maintained neat & clean. N/A 1/20/2021 Good practice 0 Closed 1/20/2021
Insp. Substation worker mess hall and storage area.
Health & Hygiene ZMDEI-Electrical
370 1/20/2021 Contractor Contractor Health-Hygiene PO N/A Daily cleaning of the walk ways at offices area. Need to continue. N/A 1/20/2021 Good practice 0 Closed 1/20/2021
Insp. Substation
Health & Hygiene ZMDEI-Electrical liquid hand wash is provided at TOZZI Camp
371 1/20/2021 Contractor Contractor Health-Hygiene PO N/A Need to refill on regular basis. N/A 1/20/2021 Good practice 0 Closed 1/20/2021
Insp. Substation WC.
1- Housekeeping conducted in around all
Contractor HSE ZMDEI-Electrical The working area must clean and tidy by conducting the work site. Instructed to the concern to
372 1/21/2021 Contractor Contractor Housekeeping UC M Poor housekeeping around all the work site. 1/21/2021 1 Closed 1/21/2021
Superv/inspection Substation daily housekeeping. maintain the area clean and tidy. 2-Provide
a waste bin
Formwork materials were observed left at site
Conducing house keeping on daily biases.
Contractor HSE ZMDEI-Electrical location in improper way and was not
373 1/21/2021 Contractor Contractor Housekeeping UC M - All materials storage at the site in a proper way Y < 1h 1/21/2021 The formwork materials has been Arranged 1 Closed 1/21/2021
Superv/inspection Substation barricaded that which may lead to a tripping
and barricaded.
hazard .
Contractor HSE ZMDEI-Electrical Waste was segregated and removed from the
374 1/22/2021 Contractor Contractor Housekeeping PO N/A Keep going. N/A 1/22/2021 Good practice 0 Closed 1/22/2021
Superv/inspection Substation worksite
Contractor HSE ZMDEI-Electrical Workers are complying with masks during work
375 1/23/2021 Contractor Contractor Awareness/Behaviours PO N/A Good practice, keep it up. N/A 1/23/2021 Good practice 0 Closed 1/23/2021
Superv/inspection Substation to comply with COVID-19 requirements.
All rebar and sharp edge must be cover at worksite. 1-Provide a flat surface for the worker to
NOTE : We are waiting to stand from the piece of wood to avoid trip
Company HSE ZMDEI-Electrical Rebar without safety cap was observed around
387 2/1/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC M install the second layer of steel reinforcement so N < 30 min 2/1/2021 hazards 2 Closed 2/1/2021
Superv/inspection Substation the all roof working area.
that we can install the wooden walkway. 2-protection Covers for exposed rebars has
been provided immediately .
Joint HSE Walk ZMDEI-Electrical Good housekeeping and clean the work place.
396 2/4/2021 Joint Co/Cntr Contractor Housekeeping PO N/A Keep going N 2/4/2021 Good practice. 0 Closed 2/4/2021
around Substation
Formwork materials were observed left at site 1-Housekeeping conducted in around all the
Joint HSE Walk ZMDEI-Electrical location in improper way and was not The working area must clean and tidy by conducting work site. Instructed to the concern to
399 2/4/2021 Joint Co/Cntr Contractor Housekeeping UC M N 2/4/2021 2 Closed 2/4/2021
around Substation barricaded that which may lead to a tripping daily housekeeping. maintain the area clean and tidy.
hazard . 2-Provide a waste bin.
Joint HSE Walk ZMDEI-Electrical There are no wooden (passages )walkways for all passages must be clean and free of any Means of safe walkway has been Provided
400 2/4/2021 Joint Co/Cntr Contractor Access/Egress Fall,Trip,Slip UC M N 2/4/2021 1 Closed 2/4/2021
around Substation workers on the roof of the building. obstructions or material. to roof building .
Instruct all workers who have been work at
Joint HSE Walk ZMDEI-Electrical Many water bottles were observed left on Our conceder workers ware instructed to clean all
401 2/4/2021 Joint Co/Cntr Contractor Housekeeping UA L N 2/4/2021 that area to clean this area and keep all 1 Closed 2/4/2021
around Substation workplace worksite and keep it tidy at all time.
work sites in order at all times.
Chemical liquid gallons were stored unsafely
Joint HSE Walk ZMDEI-Electrical Chemical liquid gallons must be stored in proper eliminate of all chemicals gallons
402 2/4/2021 Joint Co/Cntr Contractor Chemical products UA M between other material not in proper chemical N 2/4/2021 1 Closed 2/4/2021
around Substation chemical storage and with MSDS. immediately
store and without MSDS.
Company HSE ZMDEI-Electrical Worker was throwing the material from height TBT Conducted and briefed to the concern
414 2/7/2021 Company Contractor Working at Height UA M Need to arrange the workplace by safe way . Y < 30 min 2/7/2021 1 Closed 2/7/2021
Superv/inspection Substation to the ground instead of using safer technique. workman, about safe work practices.
Company HSE ZMDEI-Electrical Sharp edges (rebar) was not covered which protection Covers for exposed rebar has
417 2/9/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC M All rebar and sharp edge must bet cover at worksite. N 2/9/2021 1 Closed 2/9/2021
Superv/inspection Substation may lead to serious injury or fatality. been provided immediately.
Joint HSE Walk ZMDEI-Electrical Good management for electrical cables where
421 2/10/2021 Joint Co/Cntr Contractor Energized System Electrical Hazard PO N/A Keep going N/A 2/10/2021 Good practice. 0 Closed 2/10/2021
around Substation protected by cable sleeves and backfilling it.
Joint HSE Walk ZMDEI-Electrical Keep going, Arrange materials on a daily basis,
422 2/10/2021 Joint Co/Cntr Contractor Housekeeping PO N/A Good housekeeping and clean the work place. N/A 2/10/2021 Good practice. 0 Closed 2/10/2021
around Substation make some time for housekeeping at site
the main access has been closed to prevent
Joint HSE Walk ZMDEI-Electrical Good practice, Continue to close the passage until
423 2/10/2021 Joint Co/Cntr Contractor Access/Egress PO N/A any person to enter to building during the N/A 2/10/2021 Keep going 0 Closed 2/10/2021
around Substation further notice.
concrete pouring activity.
Joint HSE Walk ZMDEI-Electrical observed some nails on walk way at the roof of Ensure that all passages are free of nails and The crew of worker was instructed to
424 2/10/2021 Joint Co/Cntr Contractor Other (see comments) UC M N 2/10/2021 1 Closed 2/10/2021
around Substation building. obstructions. removed immediately.
Formwork materials were observed left at site
Housekeeping conducted in around all the
Joint HSE Walk ZMDEI-Electrical location in improper way and was not The working area must clean and tidy by conducting
425 2/10/2021 Joint Co/Cntr Contractor Housekeeping UC M N 2/10/2021 work site. Instructed to the concern to 1 Closed 2/10/2021
around Substation barricaded that which may lead to a tripping daily housekeeping.
maintain the area clean and tidy.
hazard .
Joint HSE Walk ZMDEI-Electrical There are no wooden (passages )walkways for all passages must be clean and free of any Means of safe walkway has been Provided
426 2/10/2021 Joint Co/Cntr Contractor Access/Egress UC M N 2/10/2021 1 Closed 2/10/2021
around Substation workers on the roof of the building. obstructions or material. to roof building .
Re-update the safety signs of first aiders
Joint HSE Walk ZMDEI-Electrical Must be update the safety signs of first aiders
427 2/10/2021 Joint Co/Cntr Contractor Health-Hygiene UA H must be posted at offices area and site. N 2/10/2021 and according to and procedure emergency 1 Closed 2/10/2021
around Substation at offices area .
response plan.
Formwork materials were observed left on one Conducting housekeeping on daily biases, all
The formwork materials has been
Contractor HSE ZMDEI-Electrical of scaffolds in improper way that which may materials storage at the site in a proper way and
428 2/12/2021 Contractor Contractor Housekeeping UC M N 2/12/2021 eliminated from that scaffold and arranged 1 Closed 12/20/2021
Superv/inspection Substation lead to a tripping hazard . barricaded.
at proper place
Health & Hygiene ZMDEI-Electrical ABG/T0ZZI Offices are maintained neat &
429 2/13/2021 Contractor Contractor Health-Hygiene PO N/A Keep going N 2/12/2021 Good practice. 0 Closed 12/20/2022
Insp. Substation clean.
Health & Hygiene ZMDEI-Electrical COVID-19 posters has been posted inside
430 2/13/2021 Contractor Contractor Health-Hygiene PO N/A Keep going N 2/12/2021 Good practice. 0 Closed 12/20/2023
Insp. Substation Administrator Office.
Health & Hygiene ZMDEI-Electrical It is observed that portable waste is provided at
431 2/13/2021 Contractor Contractor Health-Hygiene PO N/A Keep going N 2/12/2021 Good practice. 0 Closed 12/20/2024
Insp. Substation worker mess hall and storage area.
Health & Hygiene ZMDEI-Electrical
432 2/13/2021 Contractor Contractor Health-Hygiene PO N/A parking area is maintained neat & clean. Daily cleaning of the parking area shall be continued. N 2/12/2021 Good practice. 0 Closed 12/20/2025
Insp. Substation
Health & Hygiene ZMDEI-Electrical Good housekeeping is maintained inside the
433 2/13/2021 Contractor Contractor Health-Hygiene PO N/A Need to continue. N 2/12/2021 Good practice. 0 Closed 12/20/2026
Insp. Substation ABG camp WC.
Health & Hygiene ZMDEI-Electrical
434 2/13/2021 Contractor Contractor Health-Hygiene PO N/A Daily cleaning of the walk ways at offices area. Need to continue N 2/12/2021 Good practice. 0 Closed 12/20/2027
Insp. Substation
Health & Hygiene ZMDEI-Electrical
435 2/13/2021 Contractor Contractor Health-Hygiene PO N/A hand sanitizer has been provided Need to refill on regular basis N 2/12/2021 Good practice. 0 Closed 12/20/2028
Insp. Substation
Health & Hygiene ZMDEI-Electrical liquid hand was soap is provided at Zfod
436 2/13/2021 Contractor Contractor Health-Hygiene PO N/A Need to refill on regular basis. N 2/12/2021 Good practice. 0 Closed 12/20/2029
Insp. Substation Camp WC.
Company HSE ZMDEI-Electrical Vehicle/Machinery Flag man was observed escorting the concrete
437 2/15/2021 Company Contractor PO N/A Keep going N 2/15/2021 Good practice. 0 Closed 2/15/2021
Superv/inspection Substation Movement mixer while entering the worksite.
Company HSE ZMDEI-Electrical
438 2/15/2021 Company Contractor Other (see comments) UC M No barricade around the concrete pump. Need to provide means around the concrete pump. N 2/15/2021 Barricade has been Provided immediately 1 Closed 2/16/2021
Superv/inspection Substation
Housekeeping conducted in around all the
Company HSE ZMDEI-Electrical Poor housekeeping wood with nails were The working area must clean and tidy by conducting
439 2/15/2021 Company Contractor Housekeeping UC M N 2/15/2021 work site. Instructed to the concern to 1 Closed 2/16/2021
Superv/inspection Substation observed at workplace daily housekeeping.
maintain the area clean and tidy.
Poor housekeeping rubbish was observed The waste storage area should be kept clean and
Company HSE ZMDEI-Electrical Waste is being removed and disposed
440 2/15/2021 Company Contractor Housekeeping UC L remains on worksite without removing to waste tidy. N 2/15/2021 1 Closed 2/16/2021
Superv/inspection Substation properly.
area.
Company HSE ZMDEI-Electrical rebar become lower that increase the chances protection Covers for exposed rebar has
441 2/15/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC H All rebar and sharp edge must bet cover at worksite. N 2/15/2021 1 Closed 2/16/2021
Superv/inspection Substation of been injured by it. been provided immediately.
Instructed to the concern supervising authority to
Contractor HSE ZMDEI-Electrical Poor housekeeping observed at main sub- 1. Housekeeping has been conducted and
442 2/16/2021 Contractor Contractor Housekeeping UC M conduct housekeeping and maintain the area clean N 2/16/2020 1 Closed 2/16/2021
Superv/inspection Substation station building area. removed the waste from work area.
& tidy.
Observed the barrication installed to the main
Contractor HSE ZMDEI-Electrical Need to install adequate barricade to prevent the 1. Installed adequate barricade to prevent
443 2/17/2021 Contractor Contractor Working at Height UC M sub-station is not adequate to prevent from any N/A 2/17/2020 1 Closed 2/17/2021
Superv/inspection Substation workmen from any accidental fall. the workmen from any accidental fall.
accidental fall.
Poor housekeeping around worksite especially Housekeeping conducted in around all the
Company HSE ZMDEI-Electrical The working area must clean and tidy by conducting
448 2/22/2021 Company Contractor Housekeeping UC M many nails were observed on the ground this is N 2/22/2021 work site. Instructed to the concern to 1 Closed 2/24/2021
Superv/inspection Substation daily housekeeping.
the second time this issue is reported. maintain the area clean and tidy.
Open edge was observed, no handrail was proper handrails has been provided
Joint HSE Walk ZMDEI-Electrical erected and some of the workers whose Need to provide means proper handrails to prevent immediately to prevent from an accidental
449 2/24/2021 Joint Co/Cntr Contractor Safety signals/Barricades Fall,Trip,Slip UC H Y < 30 min 2/24/2021 1 Closed 2/24/2021
around Substation working at height were not using their safety from an accidental fall fall. the handrail has been installed within
harness. proper access for that platform
SIMOPS, worker was observed working under TBT to be conducted about SIMOPs activity control TBT has been conducted about SIMOPs
Company HSE ZMDEI-Electrical
455 3/1/2021 Company Contractor SIMOPS UA M working at height activity that may lead to The simultaneous works should be separated and N 3/1/2021 activity control The simultaneous works 1 Closed 3/1/2021
Superv/inspection Substation
injury by fall objects hazard that may occur. sequenced). should be separated and sequenced).
Immediately call them down, TBT conducted and TBT conducted and advised to workmen
advised to wear full body safety harness while regarding work at height requirements
Working at height without PPE or any type of
working at height. Worker man was stopped and Installed adequate barricade & lifeline to
Company HSE ZMDEI-Electrical protection” and in the same time very close to
481 3/10/2021 Company Contractor PPE UA M suspended the activity and fix the issue by installing Y < 1h 3/10/2021 prevent the workmen from any accidental 4 Closed 3/10/2021
Superv/inspection Substation forklift operation while lifting a load at 9 M
handrail complete a proper access ensure every fall, insure working at height implement
height.
working at height implement safety harness safety harness hooking .Has been provided
hooking. safe work platform
Company HSE ZMDEI-Electrical Poor housekeeping around worksite area all Ensure that all passages are free of nails and The crew of worker was instructed to
482 3/10/2021 Company Contractor Housekeeping UC M N 3/10/2021 1 Closed 3/10/2021
Superv/inspection Substation area is full of nails and other rubbish. obstructions. removed immediately.
1-Housekeeping conducted in around all the
Contractor HSE ZMDEI-Electrical Poor housekeeping was observed around The working area must clean and tidy by conducting work site. Instructed to the concern to
483 3/15/2021 Contractor Contractor Housekeeping UC M N 3/15/2021 1 Closed 3/15/2021
Superv/inspection Substation worksite. daily housekeeping. maintain the area clean and tidy.
2-Provide a waste bin.
Contractor HSE ZMDEI-Electrical Observed planks are missing on a scaffold Instructed to the scaffolding team to remove the tag 1. Scaffolding has been rectified and green
484 3/15/2021 Contractor Contractor Scaffolds/Ladders UC H Y < 1h 3/15/2021 1 Closed 3/15/2021
Superv/inspection Substation platform, while is in green tag. and then rectify it and place the tag after inspection. tag placed after re-inspection.
Formwork materials were observed left on one Conducting housekeeping on daily biases, all
The formwork materials has been
Contractor HSE ZMDEI-Electrical of scaffolds in improper way that which may materials storage at the site in a proper way and
485 3/16/2021 Contractor Contractor Housekeeping UC M N 3/16/2021 eliminated from that scaffold and arranged 1 Closed 3/16/2021
Superv/inspection Substation lead to a tripping hazard . barricaded.
at proper place
Health & Hygiene ZMDEI-Electrical Hand wash liquid soap is available at toilet.
498 3/18/2021 Contractor Contractor Health-Hygiene PO N/A Keep it up. 3/18/2021 Keep going 0 Closed 3/18/2021
Insp. Substation
Portable waste-bin provided outside the
Health & Hygiene ZMDEI-Electrical
499 3/18/2021 Contractor Contractor Health-Hygiene PO N/A COMPANY office. Need to dispose on daily basis. 3/18/2021 Keep going 0 Closed 3/18/2021
Insp. Substation
Health & Hygiene ZMDEI-Electrical Portable waste-bin provided outside the ABG
500 3/18/2021 Contractor Contractor Health-Hygiene PO N/A Need to dispose on daily basis. 3/18/2021 Keep going 0 Closed 3/18/2021
Insp. Substation office.
Steel rebar left improperly at the workplace
Company HSE ZMDEI-Electrical Need to store the rebars properly and provide Housekeeping conducted and instructed to
501 3/25/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC M without any barricade which could lead to trip/ N/A 3/26/2021 1 Closed 3/31/2021
Superv/inspection Substation barrication. maintain the site clean and tidy.
slip hazards.
Scaffold materials were not stored well and not
Company HSE ZMDEI-Electrical arranged, mix with wood, which obstructed the Need to store the scaffold materials properly and the scaffold materials has been properly
502 3/25/2021 Company Contractor Access/Egress UC M N/A 26/03/2021 1 Closed 3/31/2021
Superv/inspection Substation worker movement because the walkway was clear from access and egress. stored and clear from obstructions.
totally blocked.
TBT was conducted with both workers by
Company HSE ZMDEI-Electrical Two workers were not hooking their safety TBT shall be conducted and give awareness the company and Al Bilal and awareness
503 3/25/2021 Company Contractor Working at Height UA M N 3/25/2021 2 Closed 25/03/221
Superv/inspection Substation harness while they were working at height. training on work at height requirements. training has been provided to the involved
violators.
Need to cover the pit to prevent from fall into the pit.
Company HSE ZMDEI-Electrical Pit was not covered and no barricade around Concrete manholes were closed
505 3/25/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC M Barrication and N/A 25/03/2021 1 Closed 3/31/2021
Superv/inspection Substation the pit, which could lead to falling hazards. immediately by cover to avoiding falling.
warning signs to be provided.
1-Housekeeping conducted in around all the
work site. Instructed to the concern to
Company HSE ZMDEI-Electrical Poor housekeeping was observed inside the
506 3/25/2021 Company Contractor Housekeeping UC M Need to conduct the housekeeping on daily basis. N/A 25/03/2021 maintain the area clean and tidy. 2 Closed 25/03/2021
Superv/inspection Substation workshop.
2-Provide a waste bin.
.
Despite the high wind speed, no wind speed Wind speed device has been available to
Company HSE ZMDEI-Electrical
507 3/25/2021 Company Contractor Tools/Equipment UC M device was available to measure the speed of Wind shocks shall be provided on immediate basis. N/A 29/03/2021 measure the speed of the wind especially 1 Closed 3/31/2021
Superv/inspection Substation
the wind. for work at height activities.
Two fuel gallons left improperly under an Fuel gallons must be stored in a shadowed area.
Company HSE ZMDEI-Electrical Two empty fuel gallons has been removed
508 3/25/2021 Company Contractor Firefighting Fire Hazard UC M electrical panel, which could lead to a serious Fire extinguishers to be N 25/03/2021 1 Closed 3/31/2021
Superv/inspection Substation immediately
fire hazard. provided near the fuel storage area.
panel was opened and not locked which may Electrical panels must be locked to prevent from
Company HSE ZMDEI-Electrical lead to an electrical shock. Moreover, poor any electrical hazards. Housekeeping shall be panel was out of service, As already shown
509 3/25/2021 Company Contractor Energized System Electrical Hazard UC M N/A 26/03/2021 1 Closed 3/31/2021
Superv/inspection Substation housekeeping was observed and many conducted on daily basis, smoking is allowed at in the raised report .
cigarette buts were left on the ground. designated somking zone only.
Good housekeeping was observed, the area
Company HSE ZMDEI-Electrical was cleaned and segregated, good safety
510 3/28/2021 Company Contractor Housekeeping PO N/A Good observation, keep it. N/A 28/03/2021 Good observation. 0 Closed 28/03/2021
Superv/inspection Substation signs were installed at the gate of the
workplace.
TBT was conducted with both of them
Company HSE ZMDEI-Electrical Two workers were not hooking there safety TBT shall be conducted with both of them regarding
511 3/28/2021 Company Contractor Working at Height UA M Y < 30 min 28/03/2021 regarding the work at height by the 1 Closed 28/03/2021
Superv/inspection Substation lanyard properly. the work at height.
company.
Scaffold materials were not stored properly
Company HSE ZMDEI-Electrical The wooden materials has been properly
512 3/28/2021 Company Contractor Housekeeping UC M and not tied as well, which could fall and lead Scaffold materials shall be stored properly. N/A 29/03/2021 1 Closed 1/4/2021
Superv/inspection Substation stored and clear from obstructions.
to an injury.
Gaps were not covered properly, and the cover
was easy to be removed. Moreover, one of the proper wooden cover has been provided
Company HSE ZMDEI-Electrical
513 3/29/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC M workers removed the cover to pass the Gaps should be covered with wooden planks. N/A 29/03/2021 immediately to prevent from an accidental 1 Closed 30/03/2021
Superv/inspection Substation
electrical cable. These gaps could lead to a fall.
serious falling/Trip hazard.
Scaffold materials left improperly, which
Company HSE ZMDEI-Electrical Scaffold materials shall be stored properly, access Scaffolding materials has been removed
514 3/29/2021 Company Contractor Scaffolds/Ladders UC M blocked the access/egress of the security N/A 29/03/2021 2 Closed 30/03/2021
Superv/inspection Substation and egress shall be maintained. from access way to guard tower.
guard.
The store was not arranged properly, the Arrange material has been conducted store.
Company HSE ZMDEI-Electrical walkway was full of left materials. Moreover, Means of access and egress shall be maintained at Instructed to the storekeeper to maintain the
515 3/29/2021 Company Contractor Access/Egress UC M N/A 29/03/2021 2 Closed 30/03/2021
Superv/inspection Substation some materials stored unsafely on a high roof, all time. area clean and tidy. 2-
which could fall on the workers. Provide a waste bin.
Company HSE ZMDEI-Electrical Immediately remove from the project site,
516 3/31/2021 Company Contractor Housekeeping UC L Poor housekeeping was observed at the gate. Housekeeping shall be conducted at the gate. N/A 31/03/2021 1 Closed 1/4/2021
Superv/inspection Substation by garbage truck .
Company HSE ZMDEI-Electrical Security team left the diesel at the workplace Diesel fuel shall be removed immediatelly from
517 3/31/2021 Company Contractor Chemical products UA H N/A 31/03/2021 Immdiately remove from the project site. 1 Closed 31/03/2021
Superv/inspection Substation improperly. workplace.
Wastes was not segregated properly. Mixed
Company HSE ZMDEI-Electrical wastes concrete, iron and cladding …. ETC. Waste shall be segregated and disposed Waste is being removed and disposed
518 3/31/2021 Company Contractor Housekeeping UC M N/A 31/03/2021 1 Closed 31/03/2021
Superv/inspection Substation left at the waste area without barricade and accordingly. properly.
segregation.
Company HSE ZMDEI-Electrical Scaffold materials left improperly at the Scaffold materials shall be stored properly, access Scaffolding materials has been removed
538 4/11/2021 Company Contractor Housekeeping UC M N 4/11/2021 1 Closed 4/11/2021
Superv/inspection Substation workplace, which could lead to trip/slip hazard. and egress shall be maintained. from access way to guard tower.
Company HSE ZMDEI-Electrical Bricks left on the ground improperly at the Housekeeping to be conducted and ensure the area All bricks were arranged on the ground
553 4/12/2021 Company Contractor Housekeeping UC M N 4/12/2021 1 Closed 4/12/2021
Superv/inspection Substation workplace which could lead to trip/slip hazard. shall be clean and tidy. properly and housekeeping performed.
Materials were shifted improperly by using a 1. He was stopped by the HSE Dep.
Company HSE ZMDEI-Electrical Vehicle/Machinery forklift from the workplace to the outside area. 2. then given to him safety induction TBT was conducted with the driver and the
557 4/14/2021 Company Contractor UA M N 4/14/2021 3 Closed 4/14/2021
Superv/inspection Substation Movement Moreover, the wood was not secured that 3. advise him not to repeat that and do his job in HSE supervisor was informed.
could fall at any time. safe way
Health & Hygiene ZMDEI-Electrical Portable waste-bin and water cool box have
558 4/18/2021 Contractor Contractor Health-Hygiene PO N/A Keep it up. N/A 4/18/2021 Keep going 0 Closed 4/18/2021
Insp. Substation been provided on the second floor of building.
Wood plates and other wood structure 1- All these materials has been removed
materials were left on the top of the pipes of immediately .
Company HSE ZMDEI-Electrical Need to remove all these materials.
570 4/19/2021 Company Contractor Housekeeping UC H the concrete pouring structure. It’s considered N 4/19/2021 2- The area under the scaffold has been 3 Closed 4/20/2021
Superv/inspection Substation
a dropped object and it’s very dangerous in closed /isolated immediately .
case of falling and lead to a serious injury. 3- Posting warning safety signs
Company HSE ZMDEI-Electrical Painting and power tools stored improperly Paint packages and power cables has been
581 4/25/2021 Company Contractor Housekeeping UC L Need to stored at proper place “ storage area . N 4/25/2021 1 Closed 4/25/2021
Superv/inspection Substation inside the building. removed from workplace.
1. TBT was conducted and instructed to the
Worker was using a grinder machine without worker to wear appropriate PPE during
Company HSE ZMDEI-Electrical Need to educate the workman to wear appropriate
582 4/25/2021 Company Contractor PPE UA L wearing the required PPE (Gloves and face Y < 30 min 4/25/2021 work. 2 Closed 4/25/2021
Superv/inspection Substation personnel protective equipment during the work.
shield). 2. Worker was wearing proper PPE for the
Task.
Safety moment regarding dropped object was
Company HSE ZMDEI-Electrical conducted with all the workforce, hazard was
583 4/27/2021 Company Contractor Awareness/Behaviours PO N/A Keep it up. N 4/27/2021 Keep going 0 Closed 4/27/2021
Superv/inspection Substation explained to avoid the risk of the falling
objects.
worker was using grinder machine improperly,
worker was using grinder machine improperly, no 1- TBT was conducted with the worker and
no table was available instead of cutting on the
Company HSE ZMDEI-Electrical table was available instead of cutting on the ground hazard was explained
584 4/27/2021 Company Contractor Tools/Equipment UA L ground Moreover, despite the grinder was Y < 30 min 4/27/2021 2 Closed 4/27/2021
Superv/inspection Substation Moreover, despite the grinder was already 2- Cutter machine is adjusted on the table
already inspected, but it was observed without
inspected, but it was observed without safety cover. for safe work practices.
safety cover.
Poor housekeeping was observed under the Housekeeping conducted, and all un-
Company HSE ZMDEI-Electrical Poor housekeeping was observed under the
586 4/27/2021 Company Contractor Housekeeping UC M scaffold. Moreover, all rebars were not N 4/27/2021 wanted materials removed from the work 1 Closed 4/27/2021
Superv/inspection Substation scaffold. Moreover, all rebars were not covered.
covered. area.
Worker was standing unsafely on the table and
Company HSE ZMDEI-Electrical TBT was conducted by HSE with the
587 4/27/2021 Company Contractor Awareness/Behaviours UA M the table was not stable because it was we need to use safe platform Y < 30 min 4/27/2021 1 Closed 4/27/2021
Superv/inspection Substation worker, the table was shifted from the site.
installed on the wastes.
Joint HSE Walk ZMDEI-Electrical Despite the scaffold was inspected, but it was Need to be sure that all scaffold parts available and Toe board is already has been installed on
593 5/3/2021 Joint Co/Cntr Contractor Scaffolds/Ladders UC M N 5/3/2021 1 Closed 5/3/2021
around Substation missing for the toe board. in good conditions before tagging inspection. that scaffold immediately.
Formwork materials were observed left at site Housekeeping conducted in around all the
Joint HSE Walk ZMDEI-Electrical location in improper way near the edge that Our conceder workers ware instructed to clean all work site. Instructed to the concern to
594 5/3/2021 Joint Co/Cntr Contractor Housekeeping UC M N 5/3/2021 1 Closed 5/3/2021
around Substation which may lead to a tripping and falling hazard worksite and keep it tidy at all time. maintain the area clean and tidy and keep
. all work sites in order at all times.
Materials were shifted improperly by using a 1. He was stopped by the HSE Dep.
Joint HSE Walk ZMDEI-Electrical Vehicle/Machinery forklift from the workplace to the outside area. 2. then given to him safety induction. TBT was conducted with the driver and the
595 5/3/2021 Joint Co/Cntr Contractor UA M N 5/3/2021 1 Closed 5/3/2021
around Substation Movement Moreover, the wood was not secured that 3. advise him not to repeat that and do his job in HSE supervisor was informed.
could fall at any time. safe way.
Joint HSE Walk ZMDEI-Electrical Good housekeeping and clean the work place
596 5/3/2021 Joint Co/Cntr Contractor Housekeeping PO N/A Good practice, keep going. N 5/3/2021 Keep going 0 Closed 5/3/2021
around Substation inside of building.
Deep Pit was not covered properly and it was
not barricaded and no safety sign was
Company HSE ZMDEI-Electrical Need to cover the pit to prevent from fall into the pit Concrete manholes were closed
597 5/5/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC H available as well, Moreover, the lighting inside N 5/5/2021 1 Closed 5/6/2021
Superv/inspection Substation and Barrication and warning signs to be provided. immediately by cover to avoiding falling.
the building was very poor, which could lead to
a serious falling hazard.
Company HSE ZMDEI-Electrical Wood plate left at the building gate, which Daily housekeeping should be curried out on daily the wooden plate has been removed
598 5/5/2021 Company Contractor Housekeeping UC L N 5/5/2021 1 Closed 5/6/2021
Superv/inspection Substation obstructed the access/egress. basis . immediately
Poor housekeeping was observed, some
Company HSE ZMDEI-Electrical Housekeeping to be conducted and ensure the area Housekeeping has been conducted
599 5/5/2021 Company Contractor Housekeeping UC L wastes like (bricks, concrete, and rebar) left at N 5/5/2021 1 Closed 5/6/2021
Superv/inspection Substation shall be clean and tidy immediately.
the workplace without barricade.
Company HSE ZMDEI-Electrical Scaffold platform was longer than the scaffold The wooden planks for that platform has
601 5/5/2021 Company Contractor Scaffolds/Ladders UC M Daily inspection should be curried out on daily basis. N 5/5/2021 1 Closed 5/6/2021
Superv/inspection Substation limit as it’s shown in the above picture. been replaced with suitable ones.
Improve general housekeeping and Instructed to Housekeeping has been conducted and
Company HSE ZMDEI-Electrical Scaffolding material has been left in front of the
603 5/8/2021 Company Contractor Scaffolds/Ladders UC M arrange the materials and barricading the area. N 5/8/2021 scaffolding materials are organized 1 Closed 5/8/2021
Superv/inspection Substation door, making access difficult
accordingly.
Company HSE ZMDEI-Electrical Poor housekeeping around all the work site. It Housekeeping to be conducted and ensure the area
604 5/8/2021 Company Contractor Housekeeping UC M N 5/8/2021 Housekeeping has been conducted. 1 Closed 5/8/2021
Superv/inspection Substation can lead to various hazards (fire, fall etc) shall be clean and tidy.
Scaffolding to the roof has not correct
Company HSE ZMDEI-Electrical information on the safety tag (revision and the inspection tag has been provided in that
605 5/8/2021 Company Contractor Scaffolds/Ladders UC M provide a correct safety tag immediately. N 5/8/2021 1 Closed 5/8/2021
Superv/inspection Substation expiry date); Scaffolding without safety tag are scaffold immediately with correct details.
unacceptable
Company HSE ZMDEI-Electrical Poor housekeeping around all the work site. It Housekeeping conducted and instructed to
607 5/10/2021 Company Contractor Housekeeping UC M improve general housekeeping N 5/10/2021 1 Closed 5/10/2021
Superv/inspection Substation can lead to various hazards (fire, fall, slips, etc) maintain the site clean and tidy.
Unsafe scaffolding material has been observed the scaffolding material has been removed
Company HSE ZMDEI-Electrical Avoid putting materials on the edge of the roof to
610 5/11/2021 Company Contractor Scaffolds/Ladders UC M positioned on the edge above the door, it could N 5/11/2021 immediately and conducted housekeeping 1 Closed 5/11/2021
Superv/inspection Substation prevent to fall objects
cause objects to fall from above at that area.
Company HSE ZMDEI-Electrical Poor housekeeping around all the work site. It improve general housekeeping to prevent slip ,trips Housekeeping conducted and instructed to
615 5/20/2021 Company Contractor Housekeeping UC M N 5/20/2021 1 Closed 5/20/2021
Superv/inspection Substation can lead to various hazards (fire, fall, slips, etc) maintain the site clean and tidy.
1- Sleeves shall provided to protect the cable from 1- Sleeves shall provided to protect the
some cables were left on the ground inside the
Company HSE ZMDEI-Electrical any damage. cable from any damage.
616 5/20/2021 Company Contractor Energized System Electrical Hazard UC M workplace. It could lead to slips and trips. N 5/20/2021 2 Closed 5/20/2021
Superv/inspection Substation 2- Advised to the concern workman to use cable tie 2- Advised to the concern workman to use
to hang the cable. cable tie to hang the cable.
Positive Observation: the scaffolding has been
Company HSE ZMDEI-Electrical
617 5/20/2021 Company Contractor Scaffolds/Ladders PO N/A inspected with the correct date on the plate Keep it up. N 5/20/2021 Keep it up. 0 Closed 5/20/2021
Superv/inspection Substation
(safety label) or (safe tag)
1- Providing a proper access/egress for each
Lack of access/egress was observed for the Proper access/egress has been provided
Company HSE ZMDEI-Electrical excavation.
618 5/23/2021 Company Contractor Access/Egress UC L new excavations at the workplace. Moreover, N 5/23/2021 excavations at the workplace. Moreover, 2 Closed 5/25/2021
Superv/inspection Substation 2- providing excavation signs to be installed close to
No excavation signs were available. warning signs were available.
the excavation.
1- Daily inspection to identify the hazards.
Wood was left improperly at the workplace Civil supervisor was asked to shift the wood
Company HSE ZMDEI-Electrical 2- Daily housekeeping to remove all the obstructed
619 5/23/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UC M without a barricade, which could lead to trip N 5/23/2021 to the waste area to avoid any hazards and 2 Closed 5/25/2021
Superv/inspection Substation materials.
hazards. then removed
Joint HSE Walk ZMDEI-Electrical Crew was wearing the required PPE including
622 5/24/2021 Joint Co/Cntr Contractor PPE PO N/A Keep up N 5/24/2021 Keep up 0 Closed 5/25/2021
around Substation the face mask.
the HSE team has been Instructed to
Joint HSE Walk ZMDEI-Electrical Observed one Scaffold with expired inspection remove all expired inspection tag tag and
623 5/24/2021 Joint Co/Cntr Contractor Scaffolds/Ladders UC M Must be provide scaffolds inspector ASAP N 5/24/2021 2 Closed 5/24/2021
around Substation date " Uninspected " then suspending all activities that curry out
by scaffolds.
Concrete small holes were observed without
Joint HSE Walk ZMDEI-Electrical cover while workers passing under (Ground All concrete holes must be covered with wooden ply All concrete holes has been covered by
624 5/24/2021 Joint Co/Cntr Contractor Safety signals/Barricades UC M Y < 1h 5/24/2021 1 Closed 5/24/2021
around Substation Floor) that area that may lead to a dropped or isolated. wooden ply.
objects hazard.
Observed planks are missing and left it on a the scaffolding planks has been fixing ,
Joint HSE Walk ZMDEI-Electrical scaffold platform, while is in red tag that area Instructed to the HSE team to remove the
626 5/24/2021 Joint Co/Cntr Contractor Scaffolds/Ladders UC M Must be provide scaffolds inspector ASAP. Y > 24h 5/24/2021 2 Closed 5/24/2021
around Substation which could fall anytime as a dropped object tag and then rectify it and place the tag after
and leads to a serious injury. inspection by competent person.
Formwork materials and water bottle were Housekeeping conducted in around all the
Joint HSE Walk ZMDEI-Electrical observed left at site location in improper way Our conceder workers ware instructed to clean all work site. Instructed to the concern to
627 5/24/2021 Joint Co/Cntr Contractor Housekeeping UC L N 5/24/2021 1 Closed 5/24/2021
around Substation near the edge that which may lead to a tripping worksite and keep it tidy at all time. maintain the area clean and tidy and keep
and falling hazard. all work sites in order at all times.
Permits were not available at the workplace
close to the activity, which takes much time to Installing proper boxes close to each activity and
Company HSE ZMDEI-Electrical the proper BTW boxes has been prepared
628 5/25/2021 Company Contractor PTW UA L check the permit. Moreover, the workers and keeping the permit inside these boxes as long as N 5/25/2021 1 Closed 5/25/2021
Superv/inspection Substation immediately for each activities at areas .
the supervisor were not familiar with the permit the activity is ongoing.
for the same reason.
Company HSE ZMDEI-Electrical the safety helmet and gloves left on the Improve general housekeeping and aware workers All PPE and tools has been removed form
652 6/5/2021 Company Contractor Housekeeping UA L N 6/5/2021 1 Closed 6/5/2021
Superv/inspection Substation ground ,poor storage condition work place and properly stored.
Company HSE ZMDEI-Electrical general poor housekeeping and remove ; can general poor housekeeping and remove ; can lead Housekeeping conducted and instructed to
653 6/5/2021 Company Contractor Housekeeping UC L N 6/5/2021 1 Closed 6/5/2021
Superv/inspection Substation lead to fall or hit hazards; to fall or hit hazards. maintain the site clean and tidy.
Company HSE ZMDEI-Electrical Excavation was observed without barricade Excavation was observed without barricade (hard The barrier and warning ta has been
654 6/5/2021 Company Contractor Safety signals/Barricades Fall,Trip,Slip UA M N 6/5/2021 1 Closed 6/5/2021
Superv/inspection Substation (hard barriers) barriers). provided to the excavation.
Despite the scaffold was not completed, some all the materials has been shifted to the
Joint HSE Walk ZMDEI-Electrical
658 6/5/2021 Joint Co/Cntr contractor Scaffolds/Ladders UC M materials were left on the scaffold platform the scaffold was not ready to be used yet. N 6/5/2021 store by the scaffold team because the 1 Closed 6/5/2021
around Substation
after the work was already completed. scaffold was not ready to be used yet.
Joint HSE Walk ZMDEI-Electrical Workers inside rest shelter keep distance
659 6/8/2021 Joint Co/Cntr contractor Covid19 management PO N/A keep it up 0 Closed
around Substation between them and wear masks
the store is without proper access and 1-Daily housekeeping and arranging. they are cleaned the store and removed
Joint HSE Walk ZMDEI-Electrical
660 6/8/2021 Joint Co/Cntr Contractor Housekeeping UC M materials inside need to arrange and to 2- ensure all access are in good condition to avoid N 6/10/2021 unwanted materials and wastes and they 2 Closed 6/10/2021
around Substation
remove unwanted materials and wastes slips trips and falls haz. are fixed stair (two steps ) to the store
Joint HSE Walk ZMDEI-Electrical some working tools are stay in non-working they are removed tools which they are not
661 6/8/2021 Joint Co/Cntr Contractor Tools/Equipment Struck by/Hit by UA L N 6/8/2021 1 Closed 6/8/2021
around Substation area improperly use them and shifted them to the store
Joint HSE Walk ZMDEI-Electrical there was no hand sanitizer inside bottle , it daily checking to ensure covid-19 requirements are
662 6/8/2021 Joint Co/Cntr Contractor Health-Hygiene UC M N 6/8/2021 they refilled the hand sanitizer bottle 1 Closed 6/8/2021
around Substation was empty available
waste materials inside the designated area
they arranged materials , removed
Joint HSE Walk ZMDEI-Electrical need to segregate properly and the barricade separate waste while they are on the site before
663 6/8/2021 Joint Co/Cntr Contractor Housekeeping UA L N 6/8/2021 unwanted materials and waste , and they 2 Closed 6/8/2021
around Substation need to install and fix. shifting them to designated area
are fixed the barricade
Joint HSE Walk ZMDEI-Electrical The scaffold store area was not arranged, all arrange all materials inside and remove waste and all scaffolding materials are arranged and
667 6/8/2021 Joint Co/Cntr contractor Housekeeping UC L N 6/10/2021 1 Closed 6/10/2021
around Substation the materials were on the ground and not tide. unwanted materials wastes are removed
Contractor HSE ZMDEI-Electrical woden form which is removed still on the all materials are shifted to designated area
668 6/9/2021 Contractor Contractor Housekeeping UC M shift it do the designated area N 6/10/2021 1 Closed 6/10/2021
Superv/inspection Substation ground in same work place away from working area
they are removed properly and kept in
Contractor HSE ZMDEI-Electrical some of flamable materials are left inside
669 6/9/2021 Contractor contractor Housekeeping Fire Hazard UC M remove them N 6/9/2021 secured area (separated area covered 1 Closed 6/9/2021
Superv/inspection Substation building
place )
he took the drum out of working area , and
Contractor HSE ZMDEI-Electrical I saw worker using drum to work on 1 m height
670 6/9/2021 Contractor contractor Scaffolds/Ladders Fall,Trip,Slip UA M stopped him and asked him to replace it with ladder Y < 30 min 6/9/2021 brought ladder in good condition then he 3 Closed 6/9/2021
Superv/inspection Substation
continue his work after small awarness
observe the cable which is go out side on the
Contractor HSE ZMDEI-Electrical they are buried it under ground and became
671 6/10/2021 Contractor contractor Energized System Electrical Hazard UC M ground , any vehicle pass from that’s way will asked them to secure it N 6/10/2021 1 Closed 6/10/2021
Superv/inspection Substation secure
pass over it
Contractor HSE ZMDEI-Electrical after removing wodden frames some of rebars they are remove all rebars and keep
672 6/10/2021 Contractor contractor Housekeeping Fall,Trip,Slip UC M asked them to remove these small rebars N 6/10/2021 1 Closed 6/10/2021
Superv/inspection Substation are still fixed in the ground working area free from that haz.
Company HSE ZMDEI-Electrical
673 6/13/2021 Company Contractor Housekeeping UC L some of concrete materials still on the ground clean area N 6/14/2021 concrete materials are removed 1 Closed 6/14/2021
Superv/inspection Substation
Company HSE ZMDEI-Electrical materials out side kept non arranged and
675 6/13/2021 Company Contractor Housekeeping UC L remove them N 6/14/2021 they are removed 1 Closed 6/14/2021
Superv/inspection Substation separate in all the area
Company HSE ZMDEI-Electrical cable inside substation building stay on the it is arranged on wood near the wall and
676 6/13/2021 Company Contractor Energized System Electrical Hazard UC M secure it and keep it away N 6/14/2021 2 Closed 6/14/2021
Superv/inspection Substation ground and it was on the way hanged on cable hanger at the access way
Company HSE ZMDEI-Electrical observed person cleaning concrete cubic TBT has been conducted to that person to
677 6/13/2021 Company Contractor Energized System UA M N 6/14/2021 1 Closed 6/14/2021
Superv/inspection Substation samples pole by water in generators area avoid this job from happening again
Contractor HSE ZMDEI-Electrical find one person work on manual compactor
678 6/14/2021 Contractor Contractor PPE UA M stopped him and asked him to wear Y < 30 min 6/14/2021 he is worn and returned to the work 2 Closed 6/14/2021
Superv/inspection Substation without wearing ear protection
Contractor HSE ZMDEI-Electrical I saw the plug of cable was damage
679 6/14/2021 Contractor contractor Energized System Electrical Hazard UC M fix it or replace N 6/14/2021 the electrician replaced it with good one 1 Closed 6/14/2021
Superv/inspection Substation
Joint HSE Walk ZMDEI-Electrical Blocking the entrance of un inspected
680 6/15/2021 Joint Co/Cntr contractor Scaffolds/Ladders PO N/A N 0 N/A
around Substation scaffolding
they are removed the plank board , TBT has
Joint HSE Walk ZMDEI-Electrical flat plank board is not fixed to the scaffolding
681 6/15/2021 Joint Co/Cntr contractor Scaffolds/Ladders UA M To remove or fix it or remove N 6/16/2021 been conducted by HSE spv. To avoid it 2 Closed 6/16/2021
around Substation structure which could lead to fall from height
again
Joint HSE Walk ZMDEI-Electrical safety or warning board is fallen on the
682 6/15/2021 Joint Co/Cntr contractor Safety signals/Barricades Fall,Trip,Slip UC L To fix It back and remove all fixed nails N 6/16/2021 it is fixed 1 Closed 6/16/2021
around Substation ground ,It is full of nails
Joint HSE Walk ZMDEI-Electrical retention nylon should be provided ,MSDS as retention nylon and MSDS have been
683 6/15/2021 Joint Co/Cntr contractor Housekeeping UC M N 6/16/2021 2 Closed 6/16/2021
around Substation well provided
Joint HSE Walk ZMDEI-Electrical
684 6/15/2021 Joint Co/Cntr contractor Safety signals/Barricades UC L Wind sock is worn to replace it N 6/16/2021 wind sock is replaced with new one 1 Closed 6/16/2021
around Substation
power tools and cabled are checked and
Joint HSE Walk ZMDEI-Electrical
685 6/15/2021 Joint Co/Cntr contractor Tools/Equipment UC M Grinding machine is not inspected To inspect It and provide inspection tag N 6/16/2021 ensure there is inspection sticker for 1 Closed 6/16/2021
around Substation
everyone
Joint HSE Walk ZMDEI-Electrical scaffolding area in second floor is full with
686 6/15/2021 Joint Co/Cntr contractor Scaffolds/Ladders UC M To have house keeping and eliminate the risk N 6/16/2021 both sides of scaffolding area are cleaned 1 Closed 6/16/2021
around Substation varies materials could be falling objects .
Contractor HSE ZMDEI-Electrical observe one worker working on height without asked him to go down and wear FBH with good stopped him ,he went down worn inspected
687 6/16/2021 Contractor contractor Working at Height UA M N 6/16/2021 2 Closed 6/16/2021
Superv/inspection Substation using FBH condition and inspected FBH and returned to the work
Contractor HSE ZMDEI-Electrical checked it and because it is in good
688 6/16/2021 Contractor contractor Energized System Electrical Hazard UA M find electrical saw without inspection sticker don’t use un inspected power tools N 6/16/2021 1 Closed 6/16/2021
Superv/inspection Substation condition I put inspection sticker
Joint HSE Walk ZMDEI-Electrical some wood removed from concrete form work need to remove nails and arranged well with they are removed nails , arranged wood and
689 6/17/2021 Joint Co/Cntr contractor Housekeeping UC M N 6/19/2021 2 Closed 6/19/2021
around Substation have nails and they are untide barricade install barricade to them
they are covered well and put safety sign to
Joint HSE Walk ZMDEI-Electrical covers of openings on the second floor ground
690 6/17/2021 Joint Co/Cntr contractor Safety signals/Barricades Fall,Trip,Slip UC L prepair them well N 6/19/2021 warning others from removing these covers 2 Closed 6/19/2021
around Substation need for more securing
and to give them more attention
Joint HSE Walk ZMDEI-Electrical non used cable passed on the ground of
691 6/17/2021 Joint Co/Cntr contractor Energized System Electrical Hazard UA M remove it N 6/19/2021 it has been removed 1 Closed 6/19/2021
around Substation substation building
Joint HSE Walk ZMDEI-Electrical some of waste materials were on the ground
692 6/17/2021 Joint Co/Cntr contractor Housekeeping UC L remove them N 6/19/2021 they are removed 1 Closed 6/19/2021
around Substation behind sub station building
Joint HSE Walk ZMDEI-Electrical
693 6/17/2021 Joint Co/Cntr contractor Other (see comments) UC L sign boards were fallen because of wind fix them N 6/19/2021 they are fixed 1 Closed 6/19/2021
around Substation
Despite the mobile scaffold was already green tag has been removed till they
Joint HSE Walk ZMDEI-Electrical inspected, but the tire of the scaffold was replace tires , and put caution tape to that
695 6/21/2021 Joint Co/Cntr Contractor Scaffolds/Ladders UC M fix it or replace and re inspect the scaffold Y < 12h 6/21/2021 3 Closed 6/21/2021
around Substation damaged which made the scaffold unsafe to scaffold as a sign for don’t use and keep the
be used. scaffold under supervision and watching
Objects left improperly on the edge of the all of scaffolds kept free from drop objects ,
Joint HSE Walk ZMDEI-Electrical scaffold which made it as a dropped object, make good checking to ensure there are no objects dropping objects have been removed and
696 6/21/2021 Joint Co/Cntr Contractor Scaffolds/Ladders UA M N 6/21/2021 1 Closed 6/21/2021
around Substation these objects could lead to a serious injury can fall housekeeping has been made to ensure
(especially these objects was not tied). there is nothing on the scaffold can falling
Poor housekeeping was observed close to the pits wood cover arranged properly and
Joint HSE Walk ZMDEI-Electrical
702 6/23/2021 Joint Co/Cntr contractor Housekeeping UC L entrance of the building, wood plate and maintain houekeeping all the time N 6/23/2021 made housekeeping to remove 1 Closed 6/23/2021
around Substation
concrete remain were left without barricade. unnecessary materials and concrete waste
Joint HSE Walk ZMDEI-Electrical the scaffold support is replaced with good
703 6/23/2021 Joint Co/Cntr contractor Scaffolds/Ladders UC L The scaffold support was seen damaged. N 6/23/2021 1 Closed 6/23/2021
around Substation straight and strong one
Joint HSE Walk ZMDEI-Electrical No Fire extinguisher was available while hot fire extinguisher kept with every hot work
704 6/23/2021 Joint Co/Cntr contractor Firefighting Fire Hazard UC M Y < 30 min 6/23/2021 1 Closed 6/23/2021
around Substation work activity was ongoing. activity
Contractor HSE ZMDEI-Electrical in scaffold materials store there are some
705 6/24/2021 Contractor contractor Housekeeping UC L arrange all materials inside the store area N 6/24/2021 they are arranged all materials 1 Closed 6/24/2021
Superv/inspection Substation pipes separated on the ground
worker cleaning second floor by manual
Contractor HSE ZMDEI-Electrical nedd to close first floor to prevent anyone from install barricade and caution tape to prevent
706 6/25/2021 Contractor contractor Housekeeping UA M broush , some of waste materials falling down 6/25/2021 1 Closed 6/25/2021
Superv/inspection Substation passing under working area passing
from second floor ground openings
Contractor HSE ZMDEI-Electrical scaffold inspector came,checked the
707 6/26/2021 Contractor contractor Scaffolds/Ladders UC M the scaffold tag is expired yesterday re valid the date after inspection Y < 1h 6/26/2021 1 Closed 6/26/2021
Superv/inspection Substation scaffolds and revalid the green scaff tag
Contractor HSE ZMDEI-Electrical smoking detector of UPS battries storage cabin they are replaced its battry and it is working
708 6/27/2021 Contractor contractor Firefighting Fire Hazard UC M fix it or replace N 6/27/2021 1 Closed 6/27/2021
Superv/inspection Substation in ABG storage area was not working well
Contractor HSE ZMDEI-Electrical Vehicle/Machinery they are provide trained flag man with flag
709 6/27/2021 Contractor contractor UA M fork lift was working without flagman put trained flag man with flag Y < 30 min 6/27/2021 1 Closed 6/27/2021
Superv/inspection Substation Movement man sign to guide the equipment
Contractor HSE ZMDEI-Electrical CO2 fire extinguisher near by the AC of they are replaced it with another inspected
710 6/28/2021 Contractor contractor Firefighting Fire Hazard UC M replace it N 6/28/2021 1 Closed 6/28/2021
Superv/inspection Substation stogare area was empty one and in good condition
open all dors and windows, minimizing
Contractor HSE ZMDEI-Electrical workers working with cleaning and brushing number of workers and separate them by
711 6/28/2021 Contractor contractor Other (see comments) UC M ventilation is required Y < 30 min 6/28/2021 3 Closed 6/28/2021
Superv/inspection Substation the ground and there is a lot of dust keeping proper distance , wear dust mask
and gave them periodically rest
Contractor HSE ZMDEI-Electrical un arranged electrical cable passed on the thet are arranged it rolled it and kept it away
712 6/30/2021 Contractor contractor Housekeeping Fall,Trip,Slip UC L arrange it and keep it away from the road N 6/30/2021 1 Closed 6/30/2021
Superv/inspection Substation access way from passing road
they are return it to the store , technician
Contractor HSE ZMDEI-Electrical fix the shield to it properly and don’t use any grinder
713 7/1/2021 Contractor contractor Tools/Equipment UA L grinder machine was observed withot shield N 7/1/2021 fixed the shield and HSE checked it as re 3 Closed 7/1/2021
Superv/inspection Substation if it is not maching with safety requirments
inspection
Contractor HSE ZMDEI-Electrical they are used one tag line to orient Twall when
714 7/2/2021 Contractor contractor Lifting UA M have to use duble tag line N 7/2/2021 they are brought another tag line and used it 1 Closed 7/2/2021
Superv/inspection Substation they are install them
Contractor HSE ZMDEI-Electrical excavator operator came to the site without full ABG HSE mgr gave him brief TBT and gave
715 7/3/2021 Contractor contractor PPE UA L everyone have to wear full PPE Y < 30 min 7/3/2021 1 Closed 7/3/2021
Superv/inspection Substation PPE instructions to provide hime with full PPE
install earth to this welding machine and
Contractor HSE ZMDEI-Electrical
716 7/4/2021 Contractor contractor Energized System Electrical Hazard UC M observed welding machine without earthing the earth is required N 7/4/2021 checked there is no electrical machine 1 Closed 7/4/2021
Superv/inspection Substation
without earth
Contractor HSE ZMDEI-Electrical scaffolding inspection tag was expired &un closed that scaffold till the scaffolding team rectify it replaced green tag with red one and closed
717 7/4/2021 Contractor contractor Scaffolds/Ladders UC M N 7/4/2021 1 Closed 7/4/2021
Superv/inspection Substation suitable ground under the scaffold and inspector check it access of scaffold by warning tape
Contractor HSE ZMDEI-Electrical Vehicle/Machinery
718 7/5/2021 Contractor contractor PO N/A the dump truck moving with flag man guidness kepp it up good practice and following safety rules 0 Closed 7/5/2021
Superv/inspection Substation Movement
Contractor HSE ZMDEI-Electrical some of painting buckets found in waste area shift the buckets to the chemical waste
719 7/5/2021 Contractor contractor Housekeeping UA L segregate chemical waste from other wastes N 7/5/2021 1 Closed 7/5/2021
Superv/inspection Substation with other waste sorts designated area
Contractor HSE ZMDEI-Electrical install hard barricade to the excavation and
720 7/6/2021 Contractor contractor Excavation/Trenching UC M deep excavation without hard barricade install barricade to it N 7/6/2021 1 Closed 7/6/2021
Superv/inspection Substation put safety signs
arranged wanted materials and un wanted
Contractor HSE ZMDEI-Electrical
721 7/6/2021 Contractor contractor Housekeeping UC L observed un arranged materials in workshop make houskeeping N 7/6/2021 materials are shifted to the store area and 1 Closed 7/6/2021
Superv/inspection Substation
to waste area
the fire extinguisher is replaced and
Contractor HSE ZMDEI-Electrical
722 7/7/2021 Contractor contractor Firefighting Fire Hazard UC M observed damaged fire extinguisher at the site check all fire extinguishers are in good condition N 7/7/2021 checked all other fire extinguishers and 1 Closed 7/7/2021
Superv/inspection Substation
ensure they are in good condition
Contractor HSE ZMDEI-Electrical observed desil drum used for filling manual sent it back to designated area for keeping
723 7/7/2021 Contractor contractor Housekeeping Fire Hazard UA M keep combustable materials away from working area N 7/7/2021 1 Closed 7/7/2021
Superv/inspection Substation compactors still at the site fuel
Joint HSE Walk ZMDEI-Electrical All electrical panels and fire extinguishers were
724 7/8/2021 Joint Co/Cntr contractor Energized System PO N/A 0 Closed
around Substation re-inspected with color-coding.
Paint cans were left inside the substation
Joint HSE Walk ZMDEI-Electrical conducting housekeeping on daily basis. removed all cans and shifted to temporary
725 7/8/2021 Joint Co/Cntr contractor Housekeeping UA L building improperly that may lead to chemicals N 1 Closed 7/10/2021
around Substation - Stored chemicals waste in a designated place. chemical storage area
and fire hazards.
Joint HSE Walk ZMDEI-Electrical No safety signs were installed on all covers of
726 7/8/2021 Joint Co/Cntr contractor Other (see comments) UC M put safety signs N installed safety signs to all openings 1 Closed 7/10/2021
around Substation the main holes generally inside a building.
Safety induction and training stickers were
observed not used for workers who work at the
Joint HSE Walk ZMDEI-Electrical prepared safety induction stickers to all
727 7/8/2021 Joint Co/Cntr contractor Other (see comments) UC L site that use as identification that worker N 1 Closed 7/10/2021
around Substation persons who gain training
already got training before joining working at
the site.
Contractor HSE ZMDEI-Electrical observed some of steel rebars without caps caps are provided and covered all rebars in
728 7/10/2021 Contractor contractor Safety signals/Barricades Fall,Trip,Slip UC M N 1 Closed 7/10/2021
Superv/inspection Substation around building and cable treanch the site
Contractor HSE ZMDEI-Electrical there was electrical wood saw with old check all electrical tools and equipment to replace re checked the saw and put new inspection
729 7/10/2021 Contractor contractor Energized System Electrical Hazard UC M Y < 30 min 1 Closed 7/10/2021
Superv/inspection Substation inspection sticker all old stickers sticker
Joint HSE Walk ZMDEI-Electrical provide cooling water and rest shelters to face
730 7/11/2021 Joint Co/Cntr contractor Health-Hygiene PO N/A 0 Closed
around Substation heat stress
re inspect these fire extinguishers and put
check all fire extinguishers around the site to
Joint HSE Walk ZMDEI-Electrical some of fire extinguishers without inspection sticker to them , checked all the site to
731 7/11/2021 Joint Co/Cntr contractor Firefighting Fire Hazard UC M ensure they are in good condition with inspection N 7/11/2021 1 Closed 7/11/2021
around Substation sticker ensure there is no fire extinguisher in bad
sticker
condition
arrange materials ,remove unwanted
materials ,keep used materials properly in
Joint HSE Walk ZMDEI-Electrical general housekeeping and arrange materials is
732 7/11/2021 Joint Co/Cntr contractor Housekeeping UC L N 7/13/2021 the place with arrangement and caution 2 Closed 7/13/2021
around Substation required
tape , and make wooden box to keep
garbage bags inside properly
because these equipment were in non safe
Joint HSE Walk ZMDEI-Electrical equipment need to install inspection sticker or make a campaign to check that all power tools and condition (don’t use ) sticker putted to them
733 7/11/2021 Joint Co/Cntr contractor Tools/Equipment UC L N 7/11/2021 1 Closed 7/11/2021
around Substation don’t use sticker equipment are inspected and to other equipment which are in same
condition
the battery of generator kept out of generator
Joint HSE Walk ZMDEI-Electrical battery is prepared, and the safety sign is
734 7/11/2021 Joint Co/Cntr contractor Energized System UA M body and safety sign of entry of authorized N 7/11/2021 1 Closed 7/11/2021
around Substation replaced with new one
person only need to renew
Joint HSE Walk ZMDEI-Electrical electrical cable is passing on the ground protect all electrical cables either by using cable the cable is removed and they are used
735 7/11/2021 Joint Co/Cntr contractor Energized System Electrical Hazard UA M N 7/11/2021 1 Closed 7/11/2021
around Substation without protection hangers or by using sleeves cable hangars
Company HSE ZMDEI-Electrical the access of excavation was not maintain install hand rail to it or replace it with other kind of
737 7/12/2021 Company contractor Access/Egress UC M N 7/12/2021 they are install scaffolding access with ladder 1 Closed 7/12/2021
Superv/inspection Substation properly access
Company HSE ZMDEI-Electrical
738 7/13/2021 Company contractor PPE UA M worker using driller without ear protection have to wear it with noisy coditions Y < 30 min 7/13/2021 HSE spv. Gave him ear plug to use it 1 Closed 7/13/2021
Superv/inspection Substation
Company HSE ZMDEI-Electrical two workers go inside transformer pit (1m the are maintain wooden stair with 4 steps
739 7/14/2021 Company contractor Access/Egress UA L have to use proper access to go down Y < 30 min 7/14/2021 2 Closed 7/14/2021
Superv/inspection Substation depth) without proper access to use it for going up and down
Company HSE ZMDEI-Electrical gas detector calibration certificate was not they are brought copy of certificate and kept
740 7/15/2021 Company contractor PTW UC L asked them to keep all doccuments inside permit N 7/15/2021 1 Closed 7/15/2021
Superv/inspection Substation attached with permit it with permit packs
Company HSE ZMDEI-Electrical Vehicle/Machinery water tanker was backing on reverse without they are put flagman with every equipment
741 7/17/2021 Company contractor UA M have to put flag man to controll vehicles movement Y < 30 min 7/17/2021 1 Closed 7/17/2021
Superv/inspection Substation Movement flag man to controll their movement
After Eid Holiday, the site was observed in a
Joint HSE Walk ZMDEI-Electrical good condition inside the building and on the
742 7/25/2021 Joint Co/Cntr contractor Awareness/Behaviours PO N/A 0 Closed
around Substation back yard.
Good housekeeping camping was on going.
Some workers, employees, and security
TBT was conducted with the supervisors
Joint HSE Walk ZMDEI-Electrical supervisors were not committed to COVID
743 7/25/2021 Joint Co/Cntr contractor Covid19 management UA M N 7/25/2021 and security team about the mandatory of Closed 7/25/2021
around Substation precautions, they were not wearing masks and
wearing masks.
had no social distance.
Joint HSE Walk ZMDEI-Electrical No proper access/egress was observed for the prepared three stairs to use when they are
744 7/25/2021 Joint Co/Cntr contractor Access/Egress UC M Y < 30 min 7/25/2021 Closed 7/25/2021
around Substation workers who was working inside the pit. working inside transformers pits
Joint HSE Walk ZMDEI-Electrical barricade is installed for every transformer
745 7/25/2021 Joint Co/Cntr contractor Safety signals/Barricades UC L No barricade was available along all the pits. N 7/25/2021 Closed 7/25/2021
around Substation pits
Scaffold materials were left improperly on the
: this part of scaffolds is dismantled
Joint HSE Walk ZMDEI-Electrical scaffold, wood plate was not tied with the
746 7/25/2021 Joint Co/Cntr contractor Housekeeping UC M N 7/25/2021 Campaign is conducted to ensure no other Closed 7/25/2021
around Substation scaffold which could fall at any time and lead to
cases of drop objects are exist
a serious injury.
Steel rebar left on the workplace without
Joint HSE Walk ZMDEI-Electrical
747 7/25/2021 Joint Co/Cntr contractor Safety signals/Barricades UC L barricade, which could lead to trip and slip N 7/25/2021 it is removed Closed 7/25/2021
around Substation
hazards.
Improper dismantling was observed today, the To hold a safety meeting with construction
scaffold team have dismantled the scaffolds management and remind them their duty i.e. site
randomly and left them on the ground supervision, ensure safety of there employees.
Joint HSE Walk ZMDEI-Electrical remove all scaffold materials from the work
748 7/26/2021 Joint Co/Cntr contractor Scaffolds/Ladders UA M improperly without any barricade. Moreover, Ensure in future competent scaffold supervision. N 7/26/2021 Closed 7/26/2021
around Substation place and arranged them properly
the scaffold team starts the dismantling without Issue safety bulletin to inform other workers on the
the existence of HSE team and with a lack of safe practice in dismantling scaffold structure.
supervision. More supervision including frequent inspections.
Daily inspection.
: Poor housekeeping was observed, different
Joint HSE Walk ZMDEI-Electrical 2- Daily housekeeping. made a good housekeeping and materials
758 7/27/2021 Joint Co/Cntr contractor Housekeeping UC L materials were left out of the store area N 7/27/2021 Closed 7/27/2021
around Substation 3- construction team should ensure to store the arrangement
improperly and without barricade.
materials properly inside the storage area.
No proper table was available for cutting Daily TBT regarding ergonomic hazards.
Joint HSE Walk ZMDEI-Electrical Site supervisor bring the fire extinguisher
759 7/27/2021 Joint Co/Cntr contractor Safety signals/Barricades UC M activity, and no fire extinguisher was available 2- Site supervisor should ensure the availability of N 7/27/2021 Closed 7/27/2021
around Substation and cutting place was replaced.
as well the fire extinguisher close to all cutting activities.
Contractor HSE ZMDEI-Electrical carpenter used wood electrical saw with green ensure all tools and equipment have recent asked the electrician to re inspect it , and he
769 7/31/2021 Contractor contractor Tools/Equipment UC M N 7/31/2021 1 Closed 7/31/2021
Superv/inspection Substation inspection sticker (the color code now is blue ) inspection sticked putted blue sticker after checking
Despite the worker was wearing his safety
Company HSE ZMDEI-Electrical harness he didn’t hook his safety harness to 1- Working at height daily TBT.
770 8/1/2021 Joint Co/Cntr contractor Working at Height Fall from height UA M N 8/1/2021 work at height training has been conducted 2 Closed 8/1/2021
Superv/inspection Substation the scaffold structure while he was working at 2- Extra supervision.
height
1- Daily inspection for the scaffold. it is removed and checked all scaffolds in
Company HSE ZMDEI-Electrical Painting bucket was hanging improperly in the
772 8/1/2021 Joint Co/Cntr contractor Scaffolds/Ladders Fall,Trip,Slip UC M 2- Dropped object inspection. N 8/1/2021 same case to ensure there is no drop 1 Closed 8/1/2021
Superv/inspection Substation scaffold.
3- Extra supervision. objects
Company HSE ZMDEI-Electrical Poor housekeeping was observed inside the good housekeeping is maintained for these
773 8/1/2021 Joint Co/Cntr contractor Housekeeping Fall,Trip,Slip UC L N 8/1/2021 1 Closed 8/1/2021
Superv/inspection Substation trench. areas and for the site
First Aid Kit was available at the workplace in a
Company HSE ZMDEI-Electrical
774 8/1/2021 Joint Co/Cntr contractor N/A PO good condition, it was inspected and all the 8/1/2021 Closed 8/1/2021
Superv/inspection Substation
equipment was available.
A lot of dust was observed because of the poor
ventilation. Moreover, the workers were not
Company HSE ZMDEI-Electrical Both dust masks and eyewash were
775 8/4/2021 Joint Co/Cntr contractor Health-Hygiene UC M wearing the proper dust mask for the activity, N 8/4/2021 2 Closed 8/4/2021
Superv/inspection Substation provided.
and no eyewash was available at the
workplace.
Company HSE ZMDEI-Electrical Poor housekeeping was observed at the made a housekeeping to remove waste
776 8/4/2021 Joint Co/Cntr contractor Housekeeping Fall,Trip,Slip UC M N 8/4/2021 1 Closed 8/4/2021
Superv/inspection Substation workplace. bags and steel rebars
Company HSE ZMDEI-Electrical Different wastes were left at the workplace all unwanted materials and wastes are
777 8/4/2021 Joint Co/Cntr contractor Housekeeping Fall,Trip,Slip UA L N 8/4/2021 1 Closed 8/4/2021
Superv/inspection Substation improperly and without barricade. removed
Company HSE ZMDEI-Electrical Diesel and oil were left improperly without any all materials are removed from generator
778 8/4/2021 Joint Co/Cntr contractor Fire hazard UC M N 8/4/2021 1 Closed 8/4/2021
Superv/inspection Substation cover close to the generators. area
Contractor HSE ZMDEI-Electrical when they start with offloading of transformers they are used duble tag lines to guide the
779 8/5/2021 Contractor contractor Lifting Struck by/Hit by UA M have to use duble tag line to control the load N 8/5/2021 1 Closed 8/5/2021
Superv/inspection Substation they are used just one tag line load
Contractor HSE ZMDEI-Electrical they are used the ladder to hanging the cable the ladder should stable and someone have to another worker come to fix the ladder till
780 8/7/2021 Contractor contractor Scaffolds/Ladders Fall from height UA M Y < 30 min 8/7/2021 1 Closed 8/7/2021
Superv/inspection Substation but nobody was handle the ladder handle it while using it temporarely and quickly that person is hanged the cable
they are take a lot of waste materials from
Contractor HSE ZMDEI-Electrical good job , keep it up and clean and arrange
781 8/7/2021 Contractor contractor Housekeeping PO designated area to landfill and it 's arrangment 8/7/2021 1 Closed 8/7/2021
Superv/inspection Substation the waste designated area all the time
and cleaning are ongoing
General inspection for PPE was done, all the
workers were checked and it shows that most 1- Daily inspection.
checked and ensured all workers are wear
ZMDEI-Electrical of the helmet was in a bad condition because 2- PPE should be checked by the HSE department
782 8/8/2021 Joint HSE Walk down Joint Co/Cntr contractor PPE Injury (generic) UA M N 8/8/2021 safety shoes in good conditions and safety 2 Closed 8/8/2021
Substation of the poor quality. Moreover, some safety from time to time to make sure that all PPE is safe
helmet as well
shoes were found damaged so they should and ready to be used.
replace with a new one.
ZMDEI-Electrical Poor Housekeeping was observed at the waste materials and unwanted materials are
783 8/8/2021 Joint HSE Walk down Joint Co/Cntr contractor Housekeeping Fall,Trip,Slip UC M N 8/8/2021 1 Closed 8/8/2021
Substation workplace. removed
ZMDEI-Electrical Scaffold clamps were left improperly at the 1- Daily housekeeping for the workplace. all scaffold materials are removed and
784 8/8/2021 Joint HSE Walk down Joint Co/Cntr contractor Housekeeping Fall,Trip,Slip UC L N 8/8/2021 1 Closed 8/8/2021
Substation workplace without any box in different places. 2- A proper boxes for scaffold materials. shifted to their designated area
Contractor HSE ZMDEI-Electrical scaffolding crew dismantled unstable scaffolds all time ensure that scaffold are matching with
788 8/12/2021 Contractor contractor PO N/A N/A 8/12/2021 keep scaffolds in safe condition 1 Closed
Superv/inspection Substation and re install new scaffold with better condition safety standards
Contractor HSE ZMDEI-Electrical barricade around the new excavation was not check all barricade are in good condition and fixed
789 8/12/2021 Contractor contractor Safety signals/Barricades Fall,Trip,Slip UC L N 8/12/2021 they are install the barricades properly Closed 8/12/2021
Superv/inspection Substation installed properly properly
all electrical equipment, tools should checked by
Contractor HSE ZMDEI-Electrical electrician and put sticker if they are in good it is checked and sticker is putted by
790 8/12/2021 Contractor contractor Tools/Equipment Electrical hazard UC M new drill was without inspection sticker Y < 30 min 8/12/2021 Closed 8/12/2021
Superv/inspection Substation condition or remove them from the site if it is not in electrician
safe condition
Contractor HSE ZMDEI-Electrical the cable inside the substation building was not all cables should hanging and arranging in proper
791 8/12/2021 Contractor contractor Energized System Struck by/Hit by UC L N 8/12/2021 it is arranged Closed 8/12/2021
Superv/inspection Substation arranged properly way
Worker was standing on the scaffold materials
ZMDEI-Electrical TBT has been conducted for these 2
792 8/15/2021 Joint HSE Walk down Company contractor Awareness/Behaviours Fall from height UA M improperly and without applying work at height Y < 30 min 8/15/2021 2 Closed 8/15/2021
Substation persons which were warking togother
requirements.
Improper access/egress was observed, lack of
ZMDEI-Electrical need to prpare proper access as steops to go inside
793 8/15/2021 Joint HSE Walk down Company contractor Access/Egress Fall,Trip,Slip UC M stairs for all caravans, which could lead to 8/22/2021 they are prepared Closed 8/22/2021
Substation and out of the caravans
slip/trip hazards.
After scaffold dismantling the area was left in a
good condition, all the scaffold materials shift
ZMDEI-Electrical
794 8/17/2021 Joint HSE Walk down Company contractor PO to the scaffold stores. No obstructed materials Closed
Substation
or any other scaffold part remained at the
workplace.
Contractor HSE ZMDEI-Electrical the cable which passing on the way was pass
798 8/18/2021 Contractor contractor Welding/Cutting Electrical hazard UA M should protect the cable N 8/18/2021 they are used cable hanger to hang the cable 1 Closed 8/18/2021
Superv/inspection Substation on the ground
inside designated area some of unuseful wood
Contractor HSE ZMDEI-Electrical they are shifted all these wood outside the
799 8/18/2021 Contractor contractor Housekeeping Fall,Trip,Slip UC L pieces are kept between materials and not arrange that’s wood properly or remove them N 8/18/2021 1 Closed 8/21/2021
Superv/inspection Substation working site
arranged
Despite the area was barricaded with a hard
barricade, but the excavation was observed
ZMDEI-Electrical with deep and sharp edges that should be prepare the barricading properly for all
800 8/22/2021 Joint HSE Walk down Company contractor Excavation/Trenching Fall,Trip,Slip UC L N 8/22/2021 1 Closed 8/22/2021
Substation barricaded as well to avoid falling hazards. excavations
Moreover, the concrete trench was not
barricaded properly as well.
1- Extra supervision.
ZMDEI-Electrical Lack of eyewash at the workplace in case of
817 8/31/2021 Joint HSE Walk down Company contractor Health-Hygiene Injury (generic) UC L 2- Providing a complete HSE requirements to be N 8/31/2021 Eyewash provided immediately. 1 Closed 8/31/2021
Substation emergency, the two bottles were empty.
used in case of emergency.
ZMDEI-Electrical the space at the top is without barricade and it pipe is installed by scaffolders to keep the
830 9/4/2021 Joint HSE Walk down Company contractor Working at Height Fall from height UC M N 9/4/2021 1 Closed 9/4/2021
Substation can lead to fall of persons place more safe and prevent the falling
asked them to modify it and make it more secure caution tape and red tag are installed to
ZMDEI-Electrical
831 9/4/2021 Joint HSE Walk down Company contractor Scaffolds/Ladders Vibration hazard UC M mobile scaffold is not stable either extend the width of scaffold or install stands Y 9/9/2021 these scaffold and prevent any one from 2 Closed 9/9/2021
Substation
to it to be more stable using them
1- Housekeeping.
ZMDEI-Electrical Two Pits were not covered properly and no
832 9/5/2021 Joint HSE Walk down Company contractor Other (see comments) Fall,Trip,Slip UC M 2- Covering the pit. N 9/5/2021 they are covered properly Closed 9/5/2021
Substation barricade was available.
3- Providing safety sign for slip and trip (Advice)
Poor housekeeping was observed at the
ZMDEI-Electrical second floor of the building, different materials good housekeeping is maintained at second
833 9/5/2021 Joint HSE Walk down Company contractor Manual Handling Fall,Trip,Slip UA M N 9/5/2021 Closed 9/5/2021
Substation was left improperly inside the building without floor and all unused materials are removed
barricade.
ZMDEI-Electrical Poor barricade was installed for the deep 1- Installing a hard barricade around the trench. hard barricade with safety sign installed
836 9/5/2021 Joint HSE Walk down Company contractor Excavation/Trenching Fall,Trip,Slip UC M Y < 30 min 9/5/2021 Closed 9/5/2021
Substation trench, which could lead to falling while activity. 2- Providing a proper safety sign. around the excavation
ZFOD representative did not respect drill and explained immediately to him the
ZMDEI-Electrical
837 9/6/2021 Drill/Exercises Joint Co/Cntr contractor Awareness/Behaviours N/A UA M emergency rules and entered to site during all N 9/8/2021 importance of response to emergency alarm Closed 9/8/2021
Substation
personnel were in muster point and evacuation to the muster point
Emergency flow chart for ZMDEI project is
company emergency contacts flow chart is not
ZMDEI-Electrical updated and separated in all designated
838 9/6/2021 Drill/Exercises Joint Co/Cntr contractor Awareness/Behaviours N/A UC M up to date ,needs to be updated by company N 9/8/2021 Closed 9/8/2021
Substation places in the site in addition to keep a copy
and communicated to Tozzi/ABG.
inside permits
Contractor HSE ZMDEI-Electrical worker used grinder for softining the concrete he brought proper face shield then he return
874 9/18/2021 Contractor contractor Welding/Cutting Injury (generic) UA M have to use face protection with grinder works Y < 30 min 9/18/2021 Closed 9/18/2021
Superv/inspection Substation edges without using proper face shield to the work again
ZMDEI-Electrical Fire extinguisher was observed lay down on HSE SPV was instructed to fix all fire extinguisher
879 9/23/2021 Joint HSE Walk down Company contractor Firefighting UC L N 9/23/2021 It was placed vertically as temporary solution. 1 Closed 9/23/2021
Substation the ground. to the wall to avoid falling again on the ground.
the crane which is come to the site to lift directly after ensuring they are took the
ensure all the time they are using same equipment
Contractor HSE ZMDEI-Electrical concrete tiles to the upper floor of substation crane out of the site and cancled that
880 10/2/2021 Contractor contractor Lifting Other (see comments) UC H which they are gain approve to them and they are Y < 24h 10/2/2021 4 Closed 10/2/2021
Superv/inspection Substation building was not matching with the details at activity till they gain approve with new
matching with written doccument
the lifting plan details
Contractor HSE ZMDEI-Electrical some of waste wood were near the trench ( out
881 10/2/2021 Contractor contractor Housekeeping Fall,Trip,Slip UC M N 10/2/2021 they are made a good housekeeping 1 Closed 10/2/2021
Superv/inspection Substation side )
ZMDEI-Electrical Non-lifting team members were observed HSE SPV was instructed to ensure lifting area is It was cleared.
882 10/5/2021 Joint HSE Walk down Company contractor Lifting Fall,Trip,Slip UA H Y < 30 min 10/5/2021 2 Closed 10/5/2021
Substation inside the lifting area. always clear from unnecessary personnel. CLOSED.
Banksman was giving signals while being very Communication method was replaced as
ZMDEI-Electrical close to the load, and he was using hand per instruction.
883 10/5/2021 Joint HSE Walk down Company contractor Lifting Fall,Trip,Slip UA M Y < 30 min 10/5/2021 2 Closed 10/5/2021
Substation signals instead of phone/Radio that already TBT was conducted to lifting team.
mentioned in the lifting plan. CLOSED.
Lifting Supervisor was understand the lifting
procedure and he stay.
TBT was conducted to all lifting team point
discussed were:
Banks man and all other member should
ZMDEI-Electrical Lifting supervisor was trying to leave the lifting
884 10/5/2021 Joint HSE Walk down Company contractor Lifting Other (see comments) UA M Y < 30 min 10/5/2021 not be close or under the suspended load. 2 Closed 10/5/2021
Substation operation without supervision.
Lifting Supervisor should never leave the
lifting operation.
Lifting hazards and controls.
Lifting procedure.
CLOSED
Many tins of chemicals i.e. concrete plate joint, Request the employees to close all the open tins,
All filled buckets are closed and covered by
where find open which further contamination if and place them on dip-trays.
plastic sheet , and housekeeping has been
dropped and not stored accordingly with safety Staff members need to be informed of this bad
ZMDEI-Electrical conducted and all empty cans are sent to
891 10/9/2021 Joint HSE Walk down Company contractor Housekeeping Chemical hazard UC M standards such as the Company procedure practice, a safety bulletin can be issued on the N 10/9/2021 3 Closed 10/9/2021
Substation landfilling area
“ZFOD-H-P-027-02-E Safety standard on safe matter
control, storage and use of hazardous A formal talk to all employees regarding the
TBT has been conducted
material”. importance of safe practice.
ZMDEI-Electrical
892 10/12/2021 Joint HSE Walk down Company contractor PO Full PPE was used by workers at workplace. Closed
Substation
ZMDEI-Electrical Fire extinguisher was used during naked flame
893 10/12/2021 Joint HSE Walk down Company contractor PO Closed
Substation activity.
ZMDEI-Electrical Flashback was used for LPG cylinder during
894 10/12/2021 Joint HSE Walk down Company contractor PO Closed
Substation working with LPG torch heating.
ZMDEI-Electrical Electrical cable was passing through sharp rubber pieces are installed on the sharp
895 10/12/2021 Joint HSE Walk down Company contractor Other (see comments) Electrical hazard UC H N 10/12/2021 1 Closed 10/12/2021
Substation edges. edge to protect cable which is contact with it
Contractor HSE ZMDEI-Electrical inside substation building there are some barricade materials if you are need them or shift they are installed barricade around these
902 10/16/2021 Contractor contractor Housekeeping Fall,Trip,Slip UC M N 10/16/2021 1 Closed 10/16/2021
Superv/inspection Substation scaffold materials without barricade them to the storage area materials
they are removed all unwanted materials from
Contractor HSE ZMDEI-Electrical
903 10/16/2021 Contractor contractor PO storage caravans and shifted them to their Closed
Superv/inspection Substation
main storage (out of working area )
ZMDEI-Electrical Rubbish was left at worksite more that two HSE SPVs were instructed ensure that all rubbish Temporary waste area has been cleaned
906 10/19/2021 Joint HSE Walk down Company contractor Housekeeping N/A UC M N 10/19/2021 1 Closed 10/19/2021
Substation days without removing. must be removed on time next time. and its barricade is fixed
Lifting operation was done safely with following
ZMDEI-Electrical
907 10/20/2021 Joint HSE Walk down Company contractor PO all lifting operation safety requirements Closed
Substation
according to Lifting Procedure.
Lifting operation was done safely with following
ZMDEI-Electrical
908 10/20/2021 Joint HSE Walk down Company contractor PO all lifting operation safety requirements Closed
Substation
according to Lifting Procedure.
Contractor HSE ZMDEI-Electrical the access of oil pit is need fixing to be
909 10/23/2021 Contractor contractor Scaffolds/Ladders Fall,Trip,Slip UC M make a agood access for confined space pits Y < 1h 10/23/2021 they are fixed it with proper way 1 Closed 10/23/2021
Superv/inspection Substation moresecure
Contractor HSE ZMDEI-Electrical
910 10/23/2021 Contractor contractor PO thaey are install a lot of proper safety signs Closed
Superv/inspection Substation
ZMDEI-Electrical Proper safety signs were observed around
911 10/24/2021 Joint HSE Walk down Company contractor PO Closed
Substation deep excavation.
Deep excavation was observed partly
ZMDEI-Electrical HSE SPVs were reminded that deep excavation Replaced all soft barricades with hard
912 10/24/2021 Joint HSE Walk down Company contractor Excavation/Trenching Fall,Trip,Slip UC M barricaded with hard barriers and some of the N 10/24/2021 1 Closed 10/24/2021
Substation need to by barricaded with hard barriers ONLY. barricades
parts without.
ZMDEI-Electrical Grinder machine was left on the ground that HSE SPV was instructed to ensure all equipment They are removed all tools every day to
925 11/8/2021 Joint HSE Walk down Company contractor Tools/Equipment N/A UA M N 11/8/2021 1 Closed 11/8/2021
Substation may cause damage to it. are stored properly. keep them safely and with good conditions
ZMDEI-Electrical Due to not complete grating installation the Safety signs and safety tape are installed to
926 11/9/2021 Joint HSE Walk down Company contractor Access/Egress Fall from height UC M N 11/9/2021 1 Closed 11/9/2021
Substation ladder is not yet and proper fixed all transformer ladders
Minimum requirements FFP3 mask. If it’s possible Workers who are working with smoothing
ZMDEI-Electrical During the smoothing of concrete the worker
927 11/9/2021 Joint HSE Walk down Company contractor PPE Biological hazard UC M use grinder with vacuum. Attached example of best N 11/9/2021 and who are near by them provided with 2 Closed 11/9/2021
Substation not wear proper mask (PPE)
practice proper masks
ZMDEI-Electrical Proper barricade is installed for all required
928 11/9/2021 Joint HSE Walk down Company contractor Excavation/Trenching Fall,Trip,Slip UC M Long the “Pits” some barricading was missing. N 11/9/2021 1 Closed 11/9/2021
Substation places
ZMDEI-Electrical Positive housekeeping was observed, worksite
929 11/10/2021 Joint HSE Walk down Company contractor PO N 11/10/2021 Closed 11/10/2021
Substation was clean and tidy.
ZMDEI-Electrical Nails (sharp edges) observed on some woods Nails in these woods and other similar are
930 11/10/2021 Joint HSE Walk down Company contractor Housekeeping Struck by/Hit by UC M N 11/10/2021 2 Closed 11/10/2021
Substation that used to close the holes in the first floor. removed and few of them are bended
ZMDEI-Electrical Workers were passing through area that load TBT should be conducted to all team including the Area was blocked by barricading and door
970 12/7/2021 Joint HSE Walk down Company contractor Lifting Struck by/Hit by UA H N 12/7/2021 2 Closed 12/7/2021
Substation will pass in any minute. lifting team and lifting refresh training if possible. was closed.
ZMDEI-Electrical Workers were standing under the suspended TBT should be conducted to all team including the
971 12/7/2021 Joint HSE Walk down Company contractor Lifting Struck by/Hit by UA H N 12/7/2021 CLOSED 2 Closed 12/7/2021
Substation load. lifting team and lifting refresh training if possible.
ZMDEI-Electrical
993 12/21/2021 Joint HSE Walk down Company contractor Lifting Fall,Trip,Slip UA M Worker was lifted by forklift. N
Substation
ZMDEI-Electrical Unsafe way to use the ladder without
994 12/21/2021 Joint HSE Walk down Company contractor Working at Height Fall,Trip,Slip UA M N
Substation support.
we stopped the working on that
Improper seat for grinder operator the machine and instruct the grinder to
ZMDEI-Electrical
995 12/22/2021 Joint HSE Walk down Company contractor Welding/Cutting Other (see comments) UC M grinder have to be on a table N 12/22/2021 make a table for the cutting machine , 1 Closed 12/22/2021
Substation
furthermore the area was very dirty. and The area was brushed and
cleaned .
Improper place of the emergency alarm the alarm system is in an open way an ease
ZMDEI-Electrical to reach
996 12/22/2021 Joint HSE Walk down Company contractor Other (see comments) Biological hazard UC L siren was placed between two N 12/22/2021 1 Closed 12/22/2021
Substation
containers.
Poor cable management that create trip cable removed from the working area
ZMDEI-Electrical
997 12/22/2021 Joint HSE Walk down Company contractor Access/Egress Fall,Trip,Slip UC M hazards for worker who passing through N 12/22/2021 , and we informed electric team not to 1 Closed 12/22/2021
Substation
the pass way. repeat it again
ZMDEI-Electrical Electrical panel was covered to avoid
998 12/23/2021 Joint HSE Walk down Company contractor PO 12/23/2021 Closed
Substation electrical shock while rain.
ZMDEI-Electrical
999 12/23/2021 Joint HSE Walk down Company contractor PO Proper storage of gas cylinder. 12/23/2021 Closed
Substation
Chemical materials were stored without the NanoGrout was moved to the
MSDS and not in proper Chemical store, chemical storage immediately and
ZMDEI-Electrical
1000 12/22/2021 Joint HSE Walk down Company contractor Chemical products Chemical hazard UC H HSE SPV was instructed to move the Y < 30 min 242/12/2021 instruct the storage keeper not to 1 Closed 12/24/2021
Substation
chemical substances to a proper store such things again . And we
chemical store and provide the MSDS. have printed the MSDS .
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Need to re-inspect on
every 3 months.
N/A
N/A
N/A
Provide competent
supervision at all time.
N/A
Instructed to the
concern supervising
authority to provide
equipments certificates
with PTW.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
All powetools &
equipments must be
installed circuit breaker.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
This is a roof-bearing
scaffold not like a
normal scaffold even
inspected and tagged
by our inspector .
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
when we started the
forms, steel fixing and
concrete pouring works
few months ago the
cables trench was not
considered as confined
space.
N/A
N/A
N/A
N/A
1 8/23/2020 Joint HSE Walk down Periodic JHWD See Observation sheet Closed Sent via email on ….
2 8/26/2020 Management site visit Presence of Eni DMD, DEV Mnagr General: great safety attitude Draft
TEST
4 8/28/2020 Drill/Exercises Fire scenario: fire from oil tank See report, see observation sheet Closed
Contractor/ Dpt
Incident Date of Area/
Subcontr Involvem Task Type of Incident
No. event Location
Involvement ent
1
2
3
4
5
6
7
8
9
cells' format
Description/Comments/
Priority
Immediate action taken
Immediate Action taken
Work
Work
Reccomended Actions stoppage Issued Date Target Date
stoppage
period
No. Final
Addition
Actions Status of
Final Actions (ongoing then final) Closure Date Informati
Actually Obs.
on
Taken
Please, custom your lists filling and completing lists below. Contact EIB
Contractor/Subcontr
Dpt accountability Area/Location
Accountability
(deptaccountable) (area)
(accountable)
Subcontractor 0 A AB
Subcontractor 1 B C
Subcontractor 2 C D
Subcontractor 3 A E
Subcontractor 4 B T
Subcontractor 5 C Y
Subcontractor 6 A U
Subcontractor 7 B I
C O
A P
B
C
A
B
leting lists below. Contact EIBV HSE coordinators if other blocked lists need an
ed lists need any modification
THIS SHEET IS PROTECTED BY PASSWORD
Company Contractor HSE Superv/inspection Access/Egress Biological hazard PO Near MissH Y < 30 min Open N/A
Contractor Company HSE Superv/inspection Awareness/Behaviours Chemical hazard UA Damage tM N < 1h Closed Closed
Joint Co/Cntr Joint HSE Walk down Chemical products Cought by collapse UC Damage tL N/A < 5h N/A Draft
Other (see comments) Company Management visit Confined Space Covid19 Damage to N/A < 12h
Contractor Management visit Covid19 management Electrical hazard Fatality < 24h
Audit/Assesment Driving Fall from height First Aid Case > 24h
Drill/Exercises Energized System Fall,Trip,Slip Lost Time Injury
Health & Hygiene Insp. Excavation/Trenching Fire hazard Lost Workday Case
Firefighting Hearing hazard Medical Treatment Case
Health-Hygiene Heat stroke/dehydration Restr Workday Case
Heat/cold environment Infection hazard
Housekeeping Injury (generic)
HSE MS Musculoskeletal Disease
Illumination Noise hazard
Lifting Pressure hazard
Lone working Struck by/Hit by
Manual Handling Vibration hazard
PPE N/A
PTW Other (see comments)
Re-Fuelling
Safety signals/Barricades
Scaffolds/Ladders
SIMOPS
Tools/Equipment
Vehicle/Machinery Movement
Welding/Cutting
Working at Height
Other (see comments)
0 7 0
5 87 0
0 1 0
0 0 0
0 0 0
0 0 0
0 14 0
0 0 0
Kind of observation - all -
Years - all -
Quarters - all -
Months - all -
Days - all -
Data
Event Count of Obsv Count of Date of event
Company HSE Superv/inspection 316 316
Contractor HSE Superv/inspection 186 186
Drill/Exercises 12 12
Health & Hygiene Insp. 113 113
Joint HSE Walk around 209 209
Total Result 836 836
350 Count of osafety observa
years 2020-2
300
250
200
150
100
50
0
Event Company HSE Superv/ Contractor HSE Drill/Exercises Health &
inspection Superv/inspection
nt of osafety observations vs. events
years 2020-2021
Data
Column C
500
400
300
200
100
0
n n es .
tio tio sp nd
e c e c rcis e
In rou
sp sp e a
in in Ex en al
k
/ / ill
/ gi
rv rv Dr Hy W
pe pe & SE
Su Su th tH
E E al i n
y HS r HS He Jo
n o
pa ct
m tra
Co Co
n
ervations vs events 2020-2021
Kind of observation PO
UA
UC
. t
sp nd n ul
In ou ow s
e a r kd l Re
en al
k al ta
gi W To
Hy W E
SE HS
ntH in
t
Jo
i Jo
Years - all -
Quarters - all -
Months - all -
Days - all -
10
8
Status of Obs.
6
0
PO UA UC Total
Result
us of Obs.
Years - all -
Quarters - all -
Months - all -
Days - all -
Total Result
50%
Total
Company
23%
Contractor
15%
Joint Co/Cntr
11%
Kind of observation - multiple -
Priority - multiple -
Years - multiple -
Quarters - all -
Months - all -
Days - all -
Fi
Task Count of Obsv Health-Hygiene
Housekeeping 109 2%
Scaffolds/Ladders 56
Safety signals/Barricades 38 Excavation/Trenc
Energized System 24 3%
Other (see comments) 23 Vehicle/Machinery Movement
Lifting 23 3%
Working at Height 22
Awareness/Behaviours
Access/Egress 21 3%
Tools/Equipment 20 PPE
PPE 19 4%
Awareness/Behaviours 13
Vehicle/Machinery Movement 13
Excavation/Trenching 11 Tools/Equipment
Health-Hygiene 10 5%
Firefighting 10
Confined Space 9
Chemical products 7 Access/Egress
5%
SIMOPS 5
Welding/Cutting 4 Working at Height
Manual Handling 4 5%
Covid19 management 4 Lifting
5%
(empty) 3
Other (see commen
PTW 3
5%
Lone working 2
Lighting 1
HSE MS 1
Total Result 455
Safety observations vs. Tasks
Confined Space Priority: high+medium
Firefighting 2% June-July 2021
Health-Hygiene 2% Chemical products
2% 2%
Welding/Cutting
1% SIMOPS
Excavation/Trenching 1%
3%
Machinery Movement
3%
Housekeeping
reness/Behaviours 25%
3%
PPE
4%
ools/Equipment
5%
Access/Egress Scaffolds/Ladders
5% 13%
Working at Height
5%
fting
5% Safety signals/Barricades
Other (see comments) 9%
5% Energized System
5%
bservations vs. Tasks
ity: high+medium
une-July 2021
ades
Date of event Count of Incident No.
Total Result
Total
12
10
0
Total Result
Total
Total Result
to update graphics, in the upper bar click: DATA --> REFRESH ALL
Status of Ob
Data
Closed N/A
3 3
40 45
30 42
96 136
1 1
1
8 7
126 118
75 76
189 220
1 1
2 1
102 16
56 8
32 4
22 3
4 0
4
1 792 680