You are on page 1of 1

℄ OF STRCTURE

2 1 FOR DETAILS REFER SEPARATE DRG.

1 2

5 5 6 6

4 4 4 3 4
3
SECTION B-B
SECTION A-A

REINFORCEMENT SCHEDULE
(SUBJECT TO SITE CHECK)

S.
10000 BAR DIA OF
NO SPACING SHAPE
MARKED BAR
.

℄ OF EXP GAP ℄ OF EXP GAP 9920


6 B 1 1 16 150 C/C

670

670
8320
2 2 10 130 C/C

670 670

670 670
3 3 10 130 C/C
8320

670

670
4 4 20 110 C/C
9920

8320
5 5 16 3 NOS.

670

670
8320
6 6 16 3 NOS.

670

670
8 110 C/C LONGITUDNAL
7 7
8 130 C/C TRANSVERSE

NOTES:-
1. ALL DIMENSIONS ARE IN MM, & LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED
2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED
5 5
3. THIS DRG. SHALL BE READ IN CONJUNCTION WITH OTHER RELEVANT DRGS.
4. GRADE OF STEEL SHALL BE Fe.500 (H.Y.S.D BAR CONFORMING TO IS-1786:2008).
5. CLEAR COVER TO OUTERMOST REINF. SHALL BE 40mm.
6. MINIMUM ANCHORAGE LENGTH SHALL BE 42xDIAMETER OF BAR.
7. LAPPING OF REINFORCEMENT SHALL BE AVOIDED AS FAR AS POSSIBLE. IN CASE LAPPING OF BARS
BECOMES UNAVOIDABLE, MINIMUM LAP LENGTH OF REINFORCEMENT BARS SHALL BE
CALCULATED AS FOLLOW WITH MAXIMUM ALLLOWABLE LAPPING (p) OF 50% ONLY
(IRC:112-2011) (CLAUSE:15.2.5.1)
A A 8. LAP LENGTH Is = a1.Ibnet
a1 = 1.0 FOR p% ≤ 25%
a1 = 1.15 FOR 25% ≤ p% ≤ 33%
a1 = 1.4 FOR 33% ≤ p% ≤ 50%
(IRC:112-2011) (CLAUSE:15.2.3.3)
DEVELOPMENT LENGTH (Ibnet)
Ibnet = a.Ib (a = 1.0)
Ib = kØ
k = 40 FOR M30 (Fe500)
k = 36 FOR M35 (Fe500)
k = 34 FOR M40 (Fe500)
FOR UNFAVOURABLE BOND CONDITION THE Ib SHOULD BE MULTIPLIED BY FACTOR OF 1.43. FOR
Ø >32mm Ib, SHOULD BE INCREASED BY MULTIPLYING FACTOR ( 100 )
132- Ø
9. ALL LAPS SHALL BE SUITABLY STAGGERED AND MINIMUM DISTANCE BETWEEN THE THE ADJACENT
LAPS SHALL BE 1.30 TIMES OF LAP LENGTH..
10. GRADE OF CONCRETE SHALL BE DESIGN MIX HAVING MINIMUM 28 DAYS CHARACTERISTICS
STRENGTH OF 30 Mpa ON 50mm CUBE FOR ALL STRUCTURAL COMPONENTS.
3 2 4 1 6