pt.no. 220112.008

Since july 1997 the controller for single curcuit lubrication is replaced. The housing
looks different, function and drilling holes are compatible.
Please find here attached the timer settings.

Sticker on the
PCB Jumper for
monitoring time
P M
30 minutes
Set jumper for 4-60 1-15 5 30
min. Std. min. min
breaktime 4-60
minutes on
transfer tube
lubrication
Jumper for
monitoring time
Set jumper for
5 minutes
breaktime 1-15
hours on boom 4
lubrication
Internal button
system
to start an
intermediate
Rotary switch cycle or reset
with position
1-9, A,B, C, D,
E, F. for
breaktime
setting. See the
table below Window in the
housing of the
unit

To start an intermediate greasing cycle press the button or the


external switch for at least 2 seconds!

Rotary switch position 1 2 3 4 5 6 7 8 9 A B C D E F

Minutes 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Hours 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Position 4 ≈ 4 hrs. Position 8 ≈32 minutes
breaktime on boom breaktime on transfer tube
lubrication system lubrication systems