Professional Documents
Culture Documents
CCCC Water Transportation Consultants Co - LTD: Designer: Project: Drawing Title: Scale: Client: Notes
CCCC Water Transportation Consultants Co - LTD: Designer: Project: Drawing Title: Scale: Client: Notes
Patio de Carga
Ro-Ro y General
288000
72@4000=288000 E = 251730.984
E = 251522.010
N = 8717969.984
N = 8718165.195 1
2 2
Patio de Carga
Ro-Ro y General
Patio de Carga General
E = 251726.469
17@4000=68000
N = 8717962.174
72500
Área de inspección
E = 251696.631
N = 8717930.231
Patio de Carga General
N = 8718126.539
4500
E = 251487.134 1 E = 251668.730
N = 8718098.562 N = 8717928.926
Index
1:4000 Dangerous Container Yard Area
4000
260
Soil Classification First Maintenance
5@300=1500
Spreading Spreading
1/m 2 1/m 2
100
180
Mainly dust suppression 3 3
4000
Geotextile(150g/cm -200g/cm )
- plastic 0.25 - 0.50 0.15 - 0.25
50~80
6@300=1800
Expansion joint
- slightly or non-plastic 0.50 - 0.80 0.25 - 0.40
260
of cement stabilized crushed stone
Main Technical Parameters of Asphalt Rubber
260
C32/40 Concrete Slab 350mm Asphalt Rubber
60
175 175
Cement Stabilized Crushed Stone 150mm
30 dowel Antirust Coating
Graded Broken Stone 150mm @300
100
230 230
2-2
Horizon 1:100
Vertical 1:40
0 ISSUED FOR CONSTRUCTION 2021-05-10 Zhang Yong Chang Zhanwei Wu Zhefeng NOTES: PROJECT: DRAWING TITLE: SCALE :
CLIENT: DESIGNER : 1.Dimensions are in millimeters, except where indicated. A1: 1:20
F For Revision 2020-10-20 Zhang Yong Chang Zhanwei Wu Zhefeng 2.This project should be carried out after the underground construction is completed. A3: 1:40
E For Revision 2020-09-21 Zhang Yong Chang Zhanwei Wu Zhefeng 3.Characteristic yield strength of reinforcement and dowel is not less than 420MPa.
D For Revision 2020-08-18 Zhang Yong Chang Zhanwei Wu Zhefeng 4.The bending strength of concrete is 5.5MPa, and the bending modulus is 33GPa. Chancay Multipurpose Terminal New First Stage, Peru DATE :
C For Revision 2020-04-09 Zhang Yong Chang Zhanwei Wu Zhefeng 5.Dowels in slabs with other dimensions than 4m X 4m and odd-sized slabs shall be arranged in the same dowel spacing and
Slab Division Drawing 2021-05-10
中远海运港口秘鲁钱凯公司 2020-03-30 Zhang Yong Chang Zhanwei Wu Zhefeng length compared with those in 4m X 4m slabs. Detailed Engineering For Dangerous Container Yard Area
COSCO SHIPPING Ports Chancay PERÚ S.A. CCCC Water Transportation Consultants Co.Ltd B For Revision CODE : REVISION:
Rev. DESCRIPTION DATE BY. CKD. APD. AUD. 6.Dowels shall be coated with a bond-breaking substance to prevent bonding to the PCC during the construction period.
The Ports for ALL
7.The need for expansion joints due to the size of the area shall be evaluated ahead of construction and approved by the Engineer. P114143-E-000-RY-DWG-018-R0 R0
REVISIONS