You are on page 1of 2

SKG ENGINEERING COMPANY

C-197 & 198, PHASE - 7, FOCAL POINT, LUDHIANA

TENSILE TEST REPORT

Machine Model : UTN-400 Test File Name : 16TBAA614. Utm

Machine Serial No : 2016/233 Date & Time : 25/02/2023

Customer Name : SKG Customer Address : C-198 C-197 Ph-7 focal point Ludhiana
Punjab

Order No. : 16TBAA614 Test Type : Tensile

Lot No. : REPORT #601 Heat No. :

Input Data Output Data


Specimen Shape : Solid Round Load at Peak : 6599.603 kg

Specimen Type : Mild Steel Elongation at Peak : 12.280 mm


Specimen Description : 16TBAA614 Tensile Strength : 84.029 kg/mm2
Specimen Diameter : 10 mm
Initial G.L. For % elong : 300 mm
Pre-Load Value :0 kg
Max. Load : 40789 kg
Max. Elongation : 250 mm
Specimen Cross Section : 78.540 mm2
Area

Load Vs. Cross Head Travel

Breaking Load Specification : 5000 Kgs. ( Min. )


Actual Obs. Breaking Load : 6599.603 Kgs.
Note : D- Shackle Pin got fracture in breaking load testing

Tested By : Himanshu Approved By : Sandeep Pal


D- Shackle Pin got fracture in
Breaking Load Testing Set Up
breaking load testing

Tested By : Himanshu Approved By : Sandeep Pal