PR0POSAL

FOR
SOLAR WATER HEATER
SHANDAR INTERIORS
SITE : J N P T

Plot No. 70, Sanket Park - II, S. No. 92,


Mohammadwadi, Hadapsar,Pune -411060,Mobile : 9850601148,9689604810
E-mail : bhargavsolar@gmail.com, shashikantwakade@hotmail.com

Requirement
 Solar water heating system for Domestic application –
Pressurized
 Terrace installation
 Total capacity per Tower – - 3000 LPD

*Assumptions
Number of floors- 2 Nos
 Number of rooms = 26
 Total number of connections = 26
 Water Quality: Maximum 150 PPM. From existing Water Treatment Plant
/ treated water supplied by Municipal Corporation. Maintenance of the quality
of water supplied to the system will be responsibility of the user/developer

Note: LPD – Liters per Day


TECHNICAL OFFER:

System Specifications for 1500 LPD X 2 Nos.=3000LPD


1 Type of System Non-pressurized

2 No. (Model SUN-HDGI -


1 -1500)No
2 No. of Tanks
3 Accessories (Ball Valve & NRV
AsEtc.)
per Requirement

Hot Water Storage Tank


1 Inner Tank Material HDGI, 2 mm thickness
2 Outer cladding GI Painted sheet
Hot Water Storage Tank ± 5% to the mentioned
3 Capacity capacity of the system
4 Insulation Material Rockwool
Thickness of Insulated
100 mm ± 5%
5 Material
6 Stand Material GI powder coated
Provision for Electrical Back-
Yes, 2 points per tank
7 up

TECHNICAL OFFER:
Detailed Specification of SUNJEEVAN Flat Plate Collector
Absorber:
1 Material : Copper sheet and copper tube,
2 No. of Fin & tube : 9 Nos. ( Nine ) will be used.
3 Thickness of sheet: 34 SWG (IS-191) 0.25 mm
4 Copper Risers Tube Dia 12.5 mm +/- 0.5 mm Thickness 24 SWG
Dia 25mm +/- 0.5 mm thickness 22 SWG
5 (0.7mm) projection out: 40mm +/- 5 mm, including
Copper Header threaded connector on side of the collector box.
Solar selective coated Fin & tube of copper are
Welded in continuo process. This ultrasonic welding
6
Bonding between riser ensures high degree of thermal Efficiency.
and sheet

Selectively coated fin & tube. Continuous electroplating


7 of black chrome over nickel substance on Copper Sheet
for ultrasonic welded fin & tube
Coating
Absorptivity ( ) Alpha ; 0.96 +/- 0.02.
8
Optical properties Emissivity ( ) Epsilon ; 0.12+/- 0.02
Collector Box
Length : 2014 mm +/- 2 mm
Breadth : 1014 mm +/- 2 mm
1
Height : 100 mm + /- 2 mm
Overall dimensions
2 Fabrication of box Side with channel screw less joints to form the box
Attachment of the bottom with screws less joints and leak proof is done by
3 sheet providing silicon sealant.
a. Back Insulation : Insulation of R- value 1.67 m2
degree C/W . will be used (Rockwool of density 48
kg/m3 with Aluminum foil of thickness 0.05 mm will be
4 Box insulation used for covering back insulation

b. Side insulation : Rockwool of density 48 kg/m2


thickness of insulation 25mm Covering of Aluminum
foil of thickness 0.05 mm.5. Front Glazing : 3.2mm
thick Toughened Textured glass of transitivity of 90%
used. Glazing will be fixed on the collector box. Glass
will be firmly held, without strain, taking into account
the expansion of glass. Aluminum, glass retainer is fixed
on top of the box with screw less fitting of glass

5
Sealing between inlet & outlet of header & casing of
6 Grommet EPDM Rubber

The load of the absorber will not be on the insulation. It


will betaken by the collector box. The air gap between
the glazing and the absorber will be 30mm +/- 5mm.
7 Assembly
Testing of raisers & Header Absorber assembly tested for any leakage at a
8 Assembly pneumatic pressure of 5 kg/cm2.
The structure made with angle iron dimension of
25x 25x 3mm with an anticorrosive paint applied
9 Collector support frame
Customer Scope of Work
Electric heating coil and related accessories as required
All civil engineering work (if any) including structure, foundation, drains, etc.
required for installation of the solar collectors as per our design
Access to our engineers to your existing equipment and installation zone within your
facility during installation and commissioning process
Supply of 240 V, 1 phase, 50 Hz for the auxiliary load like pumps, motors along
with interconnecting cables, starter, switch gears, etc

* If Fabrication suport required to collecter for achiving


Shadow free area it is in your Scope

Supplier Scope of Work


Supply Installation, Commissioning & Testing of solar system at site as per
technical specification mentioned in this offer
Commercial Offer 3000 LPD

Sr. Rate
Description Quantity Amount
No. (Per LPD)

Supply of SUNJEEVAN
make gravity feed
thermo syphon Pressurized
3000 192 576000
Flat Plate Collecter Type
Solar water heating system
Capacity 3000 LPD
1
Installation &
Commissioning
3000 15
(Including unloading and
2 lifting) 45000

Accessories: System Piping,


User Piping and
Valves (Details are provided 111818 111818
in Appendix kitec full)
3 As per annexure
Labour charges for
47922 47922
4 installation of kitec pipe As per annexure
Time base Automation for
Delivery of
hot water with motorized 0 0 0
valve & wiring routing
5 on terrace

Forced Flow Automation 0 0 0


6 Tempreture controller system
7 TOTAL 780740
8 GST 5% on solar system 576000 5% 28800.0
9 GST 18% onPiping material 111818 18% 20127.2
10 GST 18% on (Automation) 0 18% 0.0
11 GST 18% labour charges 92922 18% 16726.0
12 GST 18% Forced Flow 0 18% 0.0
13 846393.2

In Word: Eight lakhs Fourty Six thousand three Hundred Ninety Three only
APPENDIX: Accessories Cost Calculation
Please note that the following calculation has been done based on our site visit and
assumptions. All values in the below tables are an estimate. Exact cost will be charged
at actual.

Terrace
Unit Rate
Length Amount
Pipe Application Pipe Size
(m) (Rs. per m) (Rs.)
Cold Water Inlet 1 ¼” (10m*2) 20 540 10800
Terrace Outlet 1 ¼”(30 m*2) 60 540 32,400
TOTAL 43,200

Unit Rate Amount


Type of Valve Valve Size Quantity
(Rs.) (Rs.)
Ball Valve 1 ¼” 4 1260 5,040
Non Return Valve 1 ¼” 2 1050 2,100
Fittings (GI) 2 4800 9,600
TOTAL 16,740

C Down-take Double line for 14 floors


Length Unit Rate Amount
pipe Pipe Size
(m) (Rs. per m) (Rs.)
kitec pipe 2532(1 1/4") 60 540 32400
kitec pipe 2025(1") 50 430 21500
kitec pipe 1620(3/4") 40 325 13000
kitec pipe 1216(1/2") 60 245 14700
TOTAL 81600
d
Unit Rate Amount
Type of Valve Valve Size Quantity
(Rs.) (Rs.)

Non Return valve ½’’ 26 460 11960


Fittings GI assorted 26 240 6240
TOTAL 18200

Grand total 159,740


material 70% 111818
Labour 30% 47922
Terms & Conditions:
NOTE:As per site condition`s for shadow free area if Fabrication Required
that will be in yours Scope
VALIDITY: The quoted prices are valid for 30 days from date of quotation and
thereafter subject to our written confirmation.
Order Placement: Purchase order needs to be placed on SANJEEVAN`S authorized
channel partner – Bhargav Enterprises, Pune
DELIVERY: We will dispatch the system within 6-8 weeks from the date of receipt
of technically & commercially clear order together with advance
payment. Delivery schedule needs to be informed if any
PRICE BASIS: The prices offered are F.O.R Site.

PAYMENT:
A 60% Advance
B 30% after Material at site
c 10% After Installation

TAXES & DUTIES:


a Excise Duty: Nil
b GST 5%. For solar system
c GST 18 % on plumbing & kitec piping material as extra
f GST 18 % charged on labour charges of Installation & piping work

WARRANTY:
The complete system is covered by a standard manufacturer's warranty against
manufacturing defects for the period as mentioned from the date of dispatch.

Warranty is not applicable for rubber parts and various accessories.

Replacement warranty 5years

Client list
Sr. Type of
Name of the Client Site Quantity
No. system

Pressurize
d, Reverse
circulation
1 Amar Builders Pune Automate 80500 LPD
d with
control
Panel
Kumar Properties & Real Thermosy
2 Pune 74000 LPD
Estates Pvt Ltd phon
Thermosy
3 Kanchan Developers Pune 86000 LPD
phon
Thermosy
4 Swapnlok Developers Bhor,Nasarapur 51500 LPD
phon
5
Maharshi karve stree Thermosy
6 karvenagar 36000 LPD
shikshan Samstha phon
Thermosy
7 Venkatesh Bhoomi LLP Pune 23000 LPD
phon
Forced
8 Vrindawan Realtors Pune flow Fix 19000 LPD
temp,
Forced
flow Fix
9 Horizon developers Kondhwa temp, 15500 LPD
Thermosy
phon
Thermosy
10 Palladium Developers Dhanori 13500 LPD
phon
Vasant Dada Sugar Thermosy
11 Pune 12000 LPD
Institute phon
Binawat Thermosy
12 Rajendra Constructions 9500 LPD
Township phon
Thermosy
13 Global Group Pune 7000 LPD
phon
Wateridge, Thermosy
14 Adharland developers 5000 LPD
undri phon
Thermosy
15 Sharda Group Pune 4000 LPD
phon
Thermosy
16 Datta Deep Hostels Talegoan 4000LPD
phon
Thermosy
17 NTPC Solapur 4000 LPD
phon
Thermosy
18 CPI Gera Realty Pvt.Ltd. Pune , SOJ 3000 LPD
phon
Thermosy
19 NTPC Nagpur 3000 LPD
phon
Thermosy
20 Chatrapati medical college Satara 2500 LPD
phon
Forced
flow Fix
21 Malpani Builders Baner 1000 LPD
temp,fix
volume
Thermosy
22 IITM, Pashan Pune 1000 LPD
phon
Thermosy More than
23 Domestic installation Pune
phon 10000 LPD
Thermo
24 Gagan Horizon Developers Pune 30000 LPD
syphon
Thermo
25 Amar Builders Pune 29000 LPD
syphon
On Going Projects
Mahindra Lifespace Pressurize
1 Pimpri 21600 LPD
Developers Ltd d
Pressurize
2 Amar Builders Pune 8000 LPD
d
Thermosy
3 Kumar Properties Pvt Ltd Pune 16000 LPD
phon
Thermosy
4 Pegasus Properties Pune 24000 LPD
phon
Thermosy
5 Swapnalok Developers Bhor 6000 PLD
phon
Thermosy
6 Shreyash Shelters Bhor 7000 LPD
phon
Thermosy
7 Konark Builders Pune 38000LPD
phon

Client List (PV-solar Power Generation )

On-Grid with
1 Ajit Bang Pune 3 KW
Net metering

On-Grid with
2 Palladium Developers Pune 3 KW
Net metering

On-Grid with
3 Isha health care Pvt.Ltd. Kunjeerwadi, pune 10kw
Net metering

On-Grid with
4 G1 Energy Kharadi 15 kw
Net metering

Amar Shrushti, On-Grid with


5 Roopchand Electricals 15 kw
Net metering
Hadapsar
Tucker AHWO,
6 Colnel Vaz Off grid 5 kw
Hadapsar

Kumar Properties & real Estate On-Grid with


7 Hadapsar,Undri 90 KW
Pvt Ltd Net metering

8 Air force Station ,Lohgaon Lohgaon Off grid 60 KW

Gandharv Excellance J Wing On-Grid with


9 Moshi 10 Kw
CHSL Net metering

On-Grid with
10 Amar Builders & Developers Pashan 12 KW
Net metering
.