You are on page 1of 3

Mu ≔ 28.

26 tonnef ⋅ m b ≔ 350 cm d ≔ 60 cm fy ≔ 4200


fc ≔ 210
Mu cm 2
ku ≔ ―― ⋅ ―― = 2.243
b ⋅ d 2 kgf

fy
m1 ≔ ――― = 23.529
0.85 ⋅ fc

1 ⎛ 2 ⋅ m1 ⋅ ku ⎞
‾‾‾‾‾‾‾‾‾‾‾
ρ ≔ ――⋅ ⎜1 - 1 - ―――― ⎟ = 0.00054 > 0.0018 As ≔ ρ ⋅ b ⋅ d = 11.286 cm 2
m1 ⎝ fy ⎠
utilizar la cuantía
1
ρ1 ≔ ρ + ―⋅ ρ = 0.0007 menor entre la
3 mínima y la
ρdiseño ≔ 0.0007 amplificada

ρdiseño ⋅ b ⋅ d
As1 ≔ ――――― = 4.2 cm 2 estoy dividiendo entre 3.5 , ya que
3.5 estoy calculando para 1 m

ϕ ≔ 1.29 cm 2
ϕ ⋅ 100 cm
S ≔ ―――― = 30.714 cm
As1

ϕ 1/2" @ 0.25
Mu ≔ 14.86 tonnef ⋅ m b ≔ 350 cm d ≔ 60 cm fy ≔ 4200
fc ≔ 210
Mu cm 2
ku ≔ ―― ⋅ ―― = 1.179
b ⋅ d 2 kgf

fy
m1 ≔ ――― = 23.529
0.85 ⋅ fc

1 ⎛ 2 ⋅ m1 ⋅ ku ⎞
‾‾‾‾‾‾‾‾‾‾‾
ρ ≔ ――⋅ ⎜1 - 1 - ―――― ⎟ = 0.00028 > 0.0018 As ≔ ρ ⋅ b ⋅ d = 5.916 cm 2
m1 ⎝ fy ⎠
utilizar la cuantía
1
ρ1 ≔ ρ + ―⋅ ρ = 0.0004 menor entre la
3 mínima y la
ρ2 ≔ 0.0004 amplificada

ρ2 ⋅ b ⋅ d
As1 ≔ ――― = 2.4 cm 2 estoy dividiendo entre 3.5 , ya que
3.5 estoy calculando para 1 m

ϕ ≔ 1.29 cm 2
ϕ ⋅ 100 cm
S ≔ ―――― = 53.75 cm
As1

ϕ 1/2" @ 0.25
Mu ≔ 86.76 tonnef ⋅ m b ≔ 350 cm d ≔ 60 cm fy ≔ 4200
fc ≔ 210
Mu cm 2
ku ≔ ―― ⋅ ―― = 6.886
b ⋅ d 2 kgf

fy
m1 ≔ ――― = 23.529
0.85 ⋅ fc

1 ⎛ 2 ⋅ m1 ⋅ ku ⎞
‾‾‾‾‾‾‾‾‾‾‾
ρ ≔ ――⋅ ⎜1 - 1 - ―――― ⎟ = 0.00167 > 0.0018 As ≔ ρ ⋅ b ⋅ d = 35.12 cm 2
m1 ⎝ fy ⎠

1
ρ1 ≔ ρ + ―⋅ ρ = 0.0022 utilizar la cuantía
3 menor entre la
ρ2 ≔ 0.0022 mínima y la
amplificada
ρ2 ⋅ b ⋅ d
As1 ≔ ――― = 13.2 cm 2
3.5

ϕ ≔ 1.99 cm 2
ϕ ⋅ 100 cm
S ≔ ―――― = 15.076 cm
As1

ϕ 5/8" @ 0.15

You might also like