You are on page 1of 8

Bar No Steel Dia Bar Area No of bar req

#3 10 mm 0.11 in^2 148 nos


#4 12 mm 0.20 in^2 82 nos
#5 16 mm 0.31 in^2 52 nos
#6 19 mm 0.44 in^2 38 nos
#7 22 mm 0.60 in^2 28 nos
#8 25 mm 0.79 in^2 22 nos
#9 29 mm 1.00 in^2 18 nos
# 10 32 mm 1.27 in^2 14 nos
# 11 35 mm 1.56 in^2 12 nos
# 14 44 mm 2.25 in^2 8 nos
# 18 57 mm 4.00 in^2 6 nos
Change Here
Lenth 1 Lenth 2 Total Length of Beam Area of Supported Slab
16.0 ft 18.0 ft 34.0 ft 288.0 ft^2

SW
For Slab
63 Psf

SW of Column For 1 Storied,PDL


6.83 kip 54.9 kip

Change Here
For 12 Storied Building Pu=

Change Here
rg fy fc'
0.025 60.0 Ksi 3.0 Ksi

So,Provide As

Column Size Use 12x54 inch Column


9x72 inch Use 14x46 inch Column
10x64 inch Use 15x43 inch Column
12x54 inch Use 16x40 inch Column
13x50 inch Use 17x38 inch Column
14x46 inch Use 18x36 inch Column
15x43 inch
16x40 inch Use minimum 4 number Steel
17x38 inch
18x36 inch
19x34 inch
20x32 inch
21x31 inch
22x29 inch
23x58 inch
Column Design

Change Here
Area of Supported Slab Total Beam Height Slab Thickness Width of Beam Web height of Beam
288.0 ft^2 25.0 inch 5.0 inch 12.0 inch 20.0 inch

Change Here Change Here


FF PW DL LL DL From Slab LL From Slab
25 Psf 50 Psf 138 Psf 70 Psf 39.6 kip 20.2 kip

For 1 Storied,PDL For 1 Storied,PDL For 1 Storied,Pu


54.9 kip 20.2 kip 111.2 kip
a
Change Here Tied 0.8
For 12 Storied Building Pu= 1335.0 kip Sprial 0.85

Tied Column Design


Ag As As(min)
644.04 16.10in^2 6.44in^2

So,Provide As 16.10in^2

#6 bar- 38 Change Here


#7 bar - 28 Main Reinforcement # 7 bar
#8 bar-22
#9 bar- 18 Use # 3 bar (Tie)
#10 bar-14 Change Here
#11 bar-12 S S S=Least Dia of Column
14 in 18 in 12 in
12

Sprial Column

Ag As As(min) Column Dia


562.86 14.07in^2 5.63in^2 27 in^2
So,Provide As 14.07in^2 Clear Cover

Bar No Steel Dia Bar Area Steel Require


#3 10 mm 0.11 in^2 128 nos
#4 12 mm 0.20 in^2 71 nos 27 in^2
#5 16 mm 0.31 in^2 46 nos Core Cutter dia Dc
#6 19 mm 0.44 in^2 32 nos
#7 22 mm 0.60 in^2 24 nos
#8 25 mm 0.79 in^2 18 nos
#9 29 mm 1.00 in^2 15 nos
# 10 32 mm 1.27 in^2 12 nos
# 11 35 mm 1.56 in^2 10 nos
# 14 44 mm 2.25 in^2 7 nos
# 18 57 mm 4.00 in^2 6 nos

Use minimum 6 number Steel


DL of Beam SW of Beam
250.00 Psf 8.5 kip

f
0.65
0.7

Example Column Size 12x14 inch


Least Dia of Column=12 inch
Change Here
Clear Cover
Clear Cover Dc Core Cutter Area, Ac Culumn Area, Ag ASI Code, Smax
1.50 inch 24.0 in^2 452.4 in^2 572.6 in^2 3.0 in

27 in^2
ore Cutter dia Dc Change Here rS1 rS2
Main Reinforcement # 7 bar 0.0060 in 0.0208 in
Use # 3 bar (Tie)
Assume Tie Spacing 3.0 inch

Tie, Provide 3.0 in c/c


ASI Code, Smax
3.0 in

Spacing Design is ok
3.0000 in 1