You are on page 1of 4

21-11-51 DEA 10000-001

DE-ACTIVATION OF PACK
VALVE
1 DEC18

ZONING DATA
___________

ZONE : 191 192


210
ACCESS : 191ML

PREPARATION
___________

PROVISION

WORK : SKILL
_____ ___
MEN _________
MAN-HOURS

MECHANIC 01

ELAPSED TIME :

GSE : 01 BLANKING CAP 98S36005003200

ALX 21-11-51
DEA 10000-001
2-400 PAGE 1
DEC 01/18
21-11-51 DEA 10000-001
DE-ACTIVATION OF PACK
VALVE
2 DEC18

001 ___________
PREPARATION

1. ON PANEL 121VU, OPEN, SAFETY AND TAG CIRCUIT


BREAKERS:

3HB AIR BLEED/COMPT TEMP/SYS 1/PACK &


RECIRC FAN CAUTION
4HB AIR BLEED/COMPT TEMP/SYS 2/PACK &
RECIRC FAN CAUTION
5HB AIR BLEED/COMPT TEMP/SYS 1/TURBO FAN
6HB AIR BLEED/COMPT TEMP/SYS 2/TURBO FAN
7HB AIR BLEED/COMPT TEMP/SYS1/PACK VALVE
8HB AIR BLEED/COMPT TEMP/SYS2/PACK VALVE

2. DISPLAY WARNING NOTICE(S) PROHIBITING


PRESSURIZATION OF PNEUMATIC SYSTEM
AND OPERATION OF AIR CONDITIONING
SYSTEM.

3. REMOVE ACCESS PANEL 191ML.

002 _____________________
REMOVAL OF PACK VALVE

REF. FIG. 211051-RAI-00100

1. DISCONNECT ELECTRICAL CONNECTOR (3).

2. HOLD PACK VALVE (4) AND REMOVE COUPLING.

3. REMOVE PACK VALVE (4).

003 ___________________________
DE-ACTIVATION OF PACK VALVE

REF. FIG. 211051-RAI-00100

1. INSTALL BLANKING CAP IN THE OPEN END OF


DUCT (5)

2. BLANK OFF ELECTRICAL CONNECTOR (3), STOW IT


AND SECURE WITH TIE CABLE.

*** CONTINUED ***

ALX 21-11-51
DEA 10000-001
2-400 PAGE 2
DEC 01/18
21-11-51 DEA 10000-001
DE-ACTIVATION OF PACK
VALVE
3 DEC18

004 ______________________________________
INSTALLATION OF DEACTIVATED PACK VALVE

REF. FIG. 211051-RAI-00100

1. POSITION PACK VALVE (4) BETWEEN DUCTS WITH


ITS ARROW SHOWING THE SAME FLOW DIRECTION
OF ARROW ON DUCT.

2. HOLD PACK VALVE (4) AND INSTALL COUPLINGS.

3. TIGHTEN COUPLINGS TO 45 LBF.IN (0.5 DAN.M).

005 __________________________________________
CLOSE-UP AFTER DE-ACTIVATION OF PACK VALVE

1. INSTALL ACCESS PANEL PREVIOUSLY REMOVED.

2. ON PANEL 121VU, REMOVE SAFETY CLIPS AND TAGS


AND CLOSE CIRCUIT BREAKERS:

3HB AIR BLEED/COMPT TEMP/SYS 1/PACK &


RECIRC FAN CAUTION
4HB AIR BLEED/COMPT TEMP/SYS 2/PACK &
RECIRC FAN CAUTION
5HB AIR BLEED/COMPT TEMP/SYS 1/TURBO FAN
6HB AIR BLEED/COMPT TEMP/SYS 2/TURBO FAN

3. DO NOT CLOSE CIRCUIT BREAKERS:

7HB AIR BLEED/COMPT TEMP/SYS1/PACK VALVE


8HB AIR BLEED/COMPT TEMP/SYS2/PACK VALVE

4. MAKE SURE THAT WORKING AREA IS CLEAN AND


CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.

5. DISPLAY A WARNING NOTICE INDICATING,


WARNING: PACK VALVE DE-ACTIVATED.

***** E N D O F T E X T *****

ALX 21-11-51
DEA 10000-001
2-400 PAGE 3
DEC 01/18
21-11-51 DEA 10000-001
4 DEC18

ALX REMOVAL AND INSTALLATION


OF PACK VALVE
21-11-51
DEA 10000-001
2-400 PAGE 4
DEC 01/18

You might also like