DATA SHEET
MSAI TEMPERATURE GAUGE
Review Code
A Accepted as it is or with minor comments
C Not Accepted
D Information Only
Date By
TOTAL OR PARTIAL REPRODUCTION AND/OR UTILISATION OF THIS DOCUMENT ARE FORBIDDEN WITHOUT PRIOR WRITTEN
AUTHORIZATION OF THE OWNER
DOCUMENT NO
EMP MALACCA STRAIT S.A
SEL-TBD-I-DS-020
REVISION STATUS
PT Loka Wahana Usaha
0 IFD
DOCUMENT NO.
SEL-TBD-I-DS-020
PAGE 2 OF 4
DATA SHEET FOR MSAI
TEMPERATURE GAUGE
CONTRACT NO.
0 14/10/2021 No comment
DOCUMENT NO.
SEL-TBD-I-DS-020
PAGE 3 OF 4
DATA SHEET FOR MSAI
TEMPERATURE GAUGE
CONTRACT NO.
TABLE OF CONTENT
Cover …………………………………………………………………. 1
Revision Historical Sheet …………………………………………………………………. 2
Table of Contect …………………………………………………………………. 3
Temperature Gauge Datasheet …………………………………………………………………. 4
DOCUMENT NO.
SEL-TBD-I-DS-020
PAGE 4 OF 4
DATA SHEET FOR MSAI TEMPERATURE
GAUGE
CONTRACT NO.
OPERATING
NO TAG NO RANGE STEM LENGTH WELL CONNECTION LAG EXT. SERVICE P&ID No
TEMP
1 TI-R-801-001 0 - 200 deg F 106 deg F 9" 1½" RF Flanged, 300# No MSBQ Area SEL-TBD-O-DW-030
2 TI-T-801-001 0 - 200 deg F 100 deg F 12" 2" RF Flanged, 150# No Crude Oil Storage Tank SEL-TBD-O-DW-031
3 TI-E-802A-001 0 - 200 deg F 100 deg F 9" 1½" RF Flanged, 300# No Inlet Crude Oil Heater (E-802A) SEL-TBD-O-DW-032 (2 of 2)
4 TI-E-802A-002 0 - 200 deg F 140 deg F 9" 1½" RF Flanged, 300# No Outlet Crude Oil Heater (E-802A) SEL-TBD-O-DW-032 (2 of 2)
5 TI-E-802B-001 0 - 200 deg F 100 degF 9" 1½" RF Flanged, 300# No Inlet Crude Oil Heater (E-802B) SEL-TBD-O-DW-032 (2 of 2)
6 TI-E-802B-002 0 - 200 deg F 140 deg F 9" 1½" RF Flanged, 300# No Outlet Crude Oil Heater (E-802B) SEL-TBD-O-DW-032 (2 of 2)
Notes:
1 Vendor to provide 316 Stainless Steel nameplate/ tag number permanently attached.
2 Thermometers and thermowells shall be supplied as complete units. Vendors shall ensure that thermometer stem lengths are matched to thermowell
lengths. stem length shall be printed on dial.
3 Thermowell shall be stamped with insertion length "U", material, connection size and type.
4 Vendor to provide thermowell calculation (including wake to natural frequency ratio) for company approval