You are on page 1of 6

INSPECTION & TESTING CORPORATION

Unit E-909, 9/F East Tower, Philippine Stock Exchange Centre, Exchange Road, Ortigas Center, Pasig City 1605 Philippines
Tel. Nos: 02-8571-6744; 02-8687-1580; 02-8638-7287; Fax No: 02-8687-4876 / Email: inspection@witco.ph

RISK ASSESMENT: NONDESTRUCTIVE TESTING AT JOB SITE


PROJECT NAME: DAVAO CITY BULK WATER
TYPE OF TESTING: RADIOGRAPHIC TESTING (RT) & DYE PENETRANT TESTING (PT)
NOTES:
 NDT Personnel are responsible for undertaking specific risk assessment for any unforeseen or additional hazards and taking appropriate action to protect their
own and others health and safety.
 NDT Personnel shall stop the work/activity if adequate control measure cannot put in place.
ACTIVITY IDENTIFIED HAZARD PERSON AT RISK RISK LEVEL RISK CONTROL / REDUCTION REMARKS
1
MEASURES
1. Entry to the jobsite /  Fall from height or  WITCO Medium  WITCO personnel shall report to
construction site a depth personnel site managers and safety officers
 Falling objects and  JVACC or to any person-in-charge at
debris personnel the area to obtain permission to
 Moving vehicle enter the site.
and machinery  WITCO personnel shall obtain
slips and trips information from site managers
or safety officers on any specific
or unusual hazards that may be
present on site to avoid.
2. Working on  Slips, trips, fall  WITCO High  Wear proper PPE’s
construction site, personnel  Ground conditions shall be
NDT Testing (RT &  JVACC assessed, suitable footwear
PT) personnel who must be worn (preferably safety
witness’s the shoes or safety boots.
inspection  In adverse conditions, no access
 APO AGUA / shall be attempted.
HEDCOR  Only designated walkways and
personnel who safe routes to be used
witness’s the  Any blocked routes or areas with
Prepared by: Checked & Approved by:

Michael A. Amparado / Sherkin E. Torres Ma. Eliza V. Mendez


INSPECTION & TESTING CORPORATION
Unit E-909, 9/F East Tower, Philippine Stock Exchange Centre, Exchange Road, Ortigas Center, Pasig City 1605 Philippines
Tel. Nos: 02-8571-6744; 02-8687-1580; 02-8638-7287; Fax No: 02-8687-4876 / Email: inspection@witco.ph

RISK ASSESMENT: NONDESTRUCTIVE TESTING AT JOB SITE


PROJECT NAME: DAVAO CITY BULK WATER
TYPE OF TESTING: RADIOGRAPHIC TESTING (RT) & DYE PENETRANT TESTING (PT)
NOTES:
 NDT Personnel are responsible for undertaking specific risk assessment for any unforeseen or additional hazards and taking appropriate action to protect their
own and others health and safety.
 NDT Personnel shall stop the work/activity if adequate control measure cannot put in place.
ACTIVITY IDENTIFIED HAZARD PERSON AT RISK RISK LEVEL RISK CONTROL / REDUCTION REMARKS
1
MEASURES
inspection falling objects and debris shall
be avoided.
 Any excavated areas shall be
avoided unless suitably
protected with edge and soil
protection barriers.
3. Working at areas  Struck by falling  WITCO High  Access to areas below with
where operatives objects and personnel working activities shall be
are working debris, crash and  JVACC avoided
overhead impact injuries personnel  Wear hardhat at all time on site
 APO AGUA /
HEDCOR
personnel who
witness’s the
inspection
4. Working near  Struck by moving  WITCO High  Areas with moving vehicle or
moving vehicle or vehicles or personnel machinery shall be avoided
machinery machinery, crash  JVACC  Only designated walkways and
and impact personnel safe routes shall be used
injuries  APO AGUA /  Wear high visibility /
Prepared by: Checked & Approved by:

Michael A. Amparado / Sherkin E. Torres Ma. Eliza V. Mendez


INSPECTION & TESTING CORPORATION
Unit E-909, 9/F East Tower, Philippine Stock Exchange Centre, Exchange Road, Ortigas Center, Pasig City 1605 Philippines
Tel. Nos: 02-8571-6744; 02-8687-1580; 02-8638-7287; Fax No: 02-8687-4876 / Email: inspection@witco.ph

RISK ASSESMENT: NONDESTRUCTIVE TESTING AT JOB SITE


PROJECT NAME: DAVAO CITY BULK WATER
TYPE OF TESTING: RADIOGRAPHIC TESTING (RT) & DYE PENETRANT TESTING (PT)
NOTES:
 NDT Personnel are responsible for undertaking specific risk assessment for any unforeseen or additional hazards and taking appropriate action to protect their
own and others health and safety.
 NDT Personnel shall stop the work/activity if adequate control measure cannot put in place.
ACTIVITY IDENTIFIED HAZARD PERSON AT RISK RISK LEVEL RISK CONTROL / REDUCTION REMARKS
1
MEASURES
HEDCOR reflectorized jackets or vest
personnel who
witness’s the
inspection
5. Working on  Struck by flying  WITCO Medium  Areas where risk of flying
construction site objects and debris personnel objects and debris i.e. grinding,
 JVACC welding, excavation, concrete
personnel breaking shall be avoided.
 APO AGUA /  Suitable eye protection shall be
HEDCOR worn
personnel who
witness’s the
inspection
6. Conducting  Over/accidental  WITCO High  WITCO personnel shall report or For other concerns,
Radiographic testing exposure to personnel inform the site managers or please refer to
on welded joints radiation  JVACC safety officer or any person-in- WITCO Radiation
personnel charge, to obtain permission to Safety Procedure
 APO AGUA / proceed the radiographic
HEDCOR testing.
personnel who  Only qualified radiographer
Prepared by: Checked & Approved by:

Michael A. Amparado / Sherkin E. Torres Ma. Eliza V. Mendez


INSPECTION & TESTING CORPORATION
Unit E-909, 9/F East Tower, Philippine Stock Exchange Centre, Exchange Road, Ortigas Center, Pasig City 1605 Philippines
Tel. Nos: 02-8571-6744; 02-8687-1580; 02-8638-7287; Fax No: 02-8687-4876 / Email: inspection@witco.ph

RISK ASSESMENT: NONDESTRUCTIVE TESTING AT JOB SITE


PROJECT NAME: DAVAO CITY BULK WATER
TYPE OF TESTING: RADIOGRAPHIC TESTING (RT) & DYE PENETRANT TESTING (PT)
NOTES:
 NDT Personnel are responsible for undertaking specific risk assessment for any unforeseen or additional hazards and taking appropriate action to protect their
own and others health and safety.
 NDT Personnel shall stop the work/activity if adequate control measure cannot put in place.
ACTIVITY IDENTIFIED HAZARD PERSON AT RISK RISK LEVEL RISK CONTROL / REDUCTION REMARKS
1
MEASURES
witness’s the and/or his assistants shall
inspection operate the exposure device.
 Al least one calibrated survey
instrument shall be made
available
 Before the radiographic
operation, safe distance shall be
determined. Safe distance shall
be computed by assuming a safe
dose of 2mR/hr.
 Barricade the area using
computed safe distance
 The controlled radiation area
shall be closed-off to the public
with the use of barriers such as
danger tapes and appropriate
warning signages.
 Trial exposure shall be
performed before proceeding
with the testing.
Prepared by: Checked & Approved by:

Michael A. Amparado / Sherkin E. Torres Ma. Eliza V. Mendez


INSPECTION & TESTING CORPORATION
Unit E-909, 9/F East Tower, Philippine Stock Exchange Centre, Exchange Road, Ortigas Center, Pasig City 1605 Philippines
Tel. Nos: 02-8571-6744; 02-8687-1580; 02-8638-7287; Fax No: 02-8687-4876 / Email: inspection@witco.ph

RISK ASSESMENT: NONDESTRUCTIVE TESTING AT JOB SITE


PROJECT NAME: DAVAO CITY BULK WATER
TYPE OF TESTING: RADIOGRAPHIC TESTING (RT) & DYE PENETRANT TESTING (PT)
NOTES:
 NDT Personnel are responsible for undertaking specific risk assessment for any unforeseen or additional hazards and taking appropriate action to protect their
own and others health and safety.
 NDT Personnel shall stop the work/activity if adequate control measure cannot put in place.
ACTIVITY IDENTIFIED HAZARD PERSON AT RISK RISK LEVEL RISK CONTROL / REDUCTION REMARKS
1
MEASURES
 No person other than the
radiographer and assistants or
trainees shall be authorized to
enter the controlled radiation
area.
 Constant surveillance of
controlled radiation area shall
be performed during
radiographic operation
 If unauthorized entry of the
controlled radiation area occurs,
stop the operation until the area
is cleared
7. Conducting Dye  Toxicities, harmful  WITCO Medium  Use proper PPE’s, long sleeves,
Penetrant testing on skin irritation personnel hard hat, safety gloves, safety
welded joints  inhalation of  JVACC glass
vapor/fumes, personnel  Use respirator or face mask
spillage  APO AGUA /  Check the nozzle of the aerosol
HEDCOR can prior to inspection
personnel who
Prepared by: Checked & Approved by:

Michael A. Amparado / Sherkin E. Torres Ma. Eliza V. Mendez


INSPECTION & TESTING CORPORATION
Unit E-909, 9/F East Tower, Philippine Stock Exchange Centre, Exchange Road, Ortigas Center, Pasig City 1605 Philippines
Tel. Nos: 02-8571-6744; 02-8687-1580; 02-8638-7287; Fax No: 02-8687-4876 / Email: inspection@witco.ph

RISK ASSESMENT: NONDESTRUCTIVE TESTING AT JOB SITE


PROJECT NAME: DAVAO CITY BULK WATER
TYPE OF TESTING: RADIOGRAPHIC TESTING (RT) & DYE PENETRANT TESTING (PT)
NOTES:
 NDT Personnel are responsible for undertaking specific risk assessment for any unforeseen or additional hazards and taking appropriate action to protect their
own and others health and safety.
 NDT Personnel shall stop the work/activity if adequate control measure cannot put in place.
ACTIVITY IDENTIFIED HAZARD PERSON AT RISK RISK LEVEL RISK CONTROL / REDUCTION REMARKS
1
MEASURES
witness’s the
inspection
8. Working on  Excess of oxygen,  WITCO Medium to  WITCO personnel shall not enter
confined space harmful gas, fume personnel High a confined space unless there is
or vapor  JVACC a system of work in place that
 Excessively high personnel has been planned, organized,
temperature  APO AGUA / performed and maintained.
 Lack of oxygen HEDCOR  Permit to work procedure
personnel who  Gas purging and ventilation
witness’s the  Testing and monitoring
inspection atmosphere
 Access and egress
 Respiratory protective
equipment

Prepared by: Checked & Approved by:

Michael A. Amparado / Sherkin E. Torres Ma. Eliza V. Mendez

You might also like