BS 5950-1:2000
tensile strength of plate,fy = 235 N/mm2
diameter of the column = 75 mm
thickness of the column = 5 mm
size of base plate = 400 x 400 mm
cl.4.13.2.2 Width of the critical section,C = 200 - 37.5
(with stiffners)
= 162.5 mm
= 223.3 N/mm2
area under the 5mm thick tube = 1138 mm2 > gross area required
therefore, effective portion can be taken as the contact area of the tube on the base plate
this means that we have to provide at least 2 x 240 (i.e approximately 500mm) base plate to
keep the base in contact with the foundation below
But, we have a Steel H-Beam beolw, and maximum width is limitted to 152mm flange width
therefore, we can use welding at the edges of the H- section to hold this moment
T
75mm tube
PT = 1.53 Pwa
Project Feature
Designed Date
Checked Date
Job Code Page 2 of 3
Reference Calculation Outputs
= 1.272 kN/mm
therefore a continuous welding of 6mm fillet weld along the beam up to the edges of the base
palte is ok
Maximum lever arm for the plate Z = 152 - 72.5 + 72.5 - 71.3
= 80.7 mm
therefore, use of 20mm thick base plate welded to 152x152x23 H-Section is satisfied
Designed Date
Checked Date
Job Code Page 3 of 3