CECB/CPCDP/JAEQR/CON/2022533 08th August 2022

Eng. Raja A Edirisuriya


Executive Project Management Director
Colombo Port City Development Project
Project Management Unit
Chaithya Road, Colombo-01
Mr. Zhao Lei,
Authorized Representative
CHEC Port City Colombo (Private) Limited,
Chaithaya Road, Colombo 01.
Dear Sir,
COLOMBO PORT CITY DEVELOPMENT PROJECT (CPCDP)
Jointly Appointed Employer’s Quality Representative (JAEQR) for Infrastructure/ Landscape Works and
Additional Service - Contract No: CHEC/CPCC/318
Sub; Package IV & V: TEST reports of the Aggregate, cement Sand & Admixtures of INSEE Mix 17
Plant trial
Reference is made to the email received from CPCC on 25th July 2022 regarding the same subject matter.

We herewith submit our review and comments on the above document for your information and necessary
action please.

Yours faithfully ,
CENTRAL ENGINEERING CONSULTANCY BUREAU

Eng. A. Galketiya,
Team Leader (JAEQR)

Encl: Document Review – 2740

Copies to e-mail:
Secretary, Ministry of Urban Development and Housing - secretary.udhousing@gmail.com,
Eng. G.K.K.A. De Silva Deputy Project Director (Structures) (PMU, MUD & H) - ariyaratna1958@gmail.com
Eng. G.R.A.S. Gunathilaka, General Manager, Central Engineering Consultancy Bureau, (CECB) - gm@cecbsl.com,
COLOMBO PORT CITY DEVELOPMENT PROJECT
INFRASTRUCTURE & LANDSCAPE WORK JAEQR/DR-2740

JAEQR
Document Review

Submission TEST reports of the Aggregate, cement Sand & Admixtures of INSEE Mix 17 Plant trial
Reference CPCC Email from CPCC (ashini@chec.lk) on July 25, Date July 25, 2022
2022 Received
Type/ Structure Package IV&V
Review Document:
Doc. No: DR - 2740 Date/s Reviewed: Aug 03, 2022
Our review comments of the above submission are as follows.
1. Coarse Aggregates
• 10% fine value is less than 150kN. Therefore concrete shall not be used in Heavy duty concrete floor
finishes.
• Physical and Chemical properties of 5-20 mm coarse aggregates are comply with the specification
requirements. 5-20mm aggregate supplier mentioned as Sansira Metal Crusher in the test reports.
• LAAV & Drying Shrinkage and Fine content tests are not done
2. Fine Aggregates
• Provided Test reports for Manufactured sand from Sansira Metal Crusher comply with the specification
requirements of Pkg IV& V.
• Sample not tested for fine content.
3. Test results for water & admixture are acceptable.
4. Chloride content & Sulphate content shall be provided

5. Sampling and testing frequency for Fine aggregate, Coarse aggregate, Cement, Water & Admixture shall be
accordance with the project specification.

Consent without comments Consent with comments 1) X Re- submit 3)


Consent with comments 2)
1) Comments to be addressed in official response and/ or update of submission
2) No official response and/or update of submission required
3) Comments to be addressed in full resubmission
Reviewed by: Checked by:

Eng. J A D N A Jayasuriya Eng. A.N Santhajeewa


Materials Engineer Resident QR Engineer-Civil

JAEQR/QMS014
Attachment I

Nalaka Santhajeewa <nalaka.portcity@gmail.com>

转发: TEST reports of the Aggregate, cement Sand & Admixtures of INSEE Mix 17
Plant trial
1 message

ashini@chec.lk <ashini@chec.lk> 25 July 2022 at 11:37


To: "Mr. Nipuna (new address)" <nipuna.jaeqr@yahoo.com>, "Mr.Nalaka" <nalaka.portcity@gmail.com>
Cc: "Mr. Joely" <zhaolei@chec.bj.cn>, "Mr. Lizenghui" <zhli@chec.bj.cn>, "Mr. Zhou jianze" <jzzhou@chec.bj.cn>, "Mr. Yu"
<dwyu@chec.bj.cn>, "Mr. Prageeth" <prageeth@chec.lk>

To : Mr. Nipunna,

Reference to the trailing mail below,

Pls. find the attached test reports of Aggregate , Cement , Sand and Admixture which were used for the Insee Mix-17
Plant Trial on 22nd July 2022 for your information and necessary action .

Your quick response is highly regarded.

Thanks & Regards

Ashini Dalupotha

ashini@chec.lk

发件人: waratha vinayakaraja saravanan


发送时间: 2022-07-25 11:36
收件人: ashini
抄送: 周健泽
主题: TEST reports of the Aggregate, cement Sand & Admixtures of INSEE Mix 17 Plant trial

Dear M/S Ashini

We have attached the relevant test reports of the Aggregate, cement Sand & Admixtures which were used
for the INSEE Mix 17 Plant trial on the 22nd July 2022. n

Kindly get the JAEQR concern regarding whether these attached reports are enough with the Trial Mix Data
sheet for the submission to get the approval for the Mix 17 from INSEE & to close the GO-076.

Thank you

W.V.Saravanan
THEC

5 attachments
INSEE Reports and Docs complete 2022_3_29 (1).pdf
17318K
Optima 1100_Colombo Uni_25.10.2021.pdf
155K
Optima 1100_Colombo Uni_25.10.2021_Cl Content.pdf
167K
Optima 1100_Colombo Uni_25.10.2021_Solid Content.pdf
148K
Optima 1100_ITI_27.10.2021_Alkali & Setting Time.pdf
951K
Page: Page 1 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

INSEE Concrete – Northern Colombo Batching Plant.


Peliyagoda, Sri Lanka.

Introduction to INSEE Concrete & Raw Material Test reports.


Page: Page 2 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

Table of Contents

1.0 Introduction.

2.0 INSEE Concrete – Sri Lanka.

3.0 Coarse Aggregate Test Reports.

3.1 5-20mm Aggregate Test Reports – Physical Properties

3.2 5-14mm Aggregate Test Reports – Physical Properties

3.3 Coarse Aggregate Test Reports – Chemical Properties

4.0 Fine Aggregate Test Reports.

4.1 Manufactured Sand Test Reports

4.2 River Sand Test Reports

5.0 Cement Test Reports.

5.1 INSEE Extra (25% Fly Ash Blended PPC)

5.2 INSEE Rapid Flow Plus (15% Fly Ash Blended PPC)

5.3 INSEE Rapid Flow (OPC)

6.0 Water Test Report.

7.0 Ice Test Report.


Page: Page 3 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

1. Introduction
We, Siam City Cement (Lanka) Limited intends to expand our business portfolio with the introduction of
INSEE Concrete - high performance ready-mixed concrete to Sri Lanka by Quarter 03, 2018.

1.1 Introduction to Siam City Cement (Lanka) Limited

Siam City Cement (Lanka) Limited (SCCCL), formerly known as Holcim (Lanka) Limited is the only
cement manufacturer in Sri Lanka, equipped with strategically located integrated cement manufacturing
plant, cement grinding stations, import terminals and warehouses.
Holcim Lanka (Now known as SCCCL) was under the Global Cement and Aggregate giant,
“LafargeHolcim” Group from 1996 to 2016. Since last year we are a proud subsidiary of Siam City Cement
Public Company Limited (SCCC) and they continue to invest on SCCCL to expand capacities, boost
innovation, world class talent development, promote safety, sustainable development & leadership and new
business development.
INSEE Concrete is one of the key new business channels of SCCCL where SCCC Group is very positive
on providing their assistance on financing and technical knowhow.

1.2 Introduction to Siam City Cement Public Company Limited

Siam City Cement Public Company Limited (SCCC) is the second largest cement producer in Thailand,
head quartered in Bangkok with three high capacity cement plants located in Saraburi Province, Thailand.
SCCC accompanies a proud track record of 50 years supporting Thailand’s development through
innovative products and solutions.
SCCC’s business portfolio includes Siam City Concrete Co. Ltd, four cement manufacturing subsidiaries
in the region including Vietnam, Sri Lanka, Cambodia and Bangladesh. Further INSEE Ecocycle, Siam
City Power Co. Ltd, INSEE Superblocks, INSEE Digital and Conwood Co. Ltd., Indonesia are fully owned
subsidiaries of SCCC Group.
Page: Page 4 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

1.3 Introduction to Siam City Concrete Co. Ltd

Siam City Concrete Co. Ltd., (SCCO) was established in 1985 as a subsidiary of Siam City
Cement Public Company Limited (SCCC) in response to constant increasing demand from construction
industry. SCCO acquired solid foundations in ready-mixed industry with comprehensive knowledge and
advanced technology from Holcim, world’s leading cement supplier from Switzerland with subsidiaries
in over 70 countries as SCCC became an affiliate of Holcim Group in 1998.
With more than 30 years’ experience ready-mixed industry, high focus on continuous improvement &
innovation and commitment to offer best service & solutions to customers SCCO has become one of
Thailand’s leading concrete solution providers. As of today, SCCO operates 105 own ready-mixed
concrete plants across Thailand, with a capacity of more than one million cubic meters of concrete per
month and continue to grow including a franchise model which has more than 150 franchised plants.

Ready-mixed concrete business in Sri Lanka is fully supported by SCCO Thailand in terms of plant
design & implementation, knowledge transfer, technical support & training, newest technology,
systems and logistics optimization.

2. INSEE Concrete – Sri Lanka

2.1 Objectives
Introduce INSEE ready-mixed concrete solutions to Sri Lankan market with high performance concrete,
optimized mix designs, computer aided batching, high tech quality control and high-performance
aggregates.
Introduce innovative and application based concrete solutions to commercial market and value-added
solutions to specific customer needs.
INSEE Concrete has its footprint in many iconic projects in the Southeast Asia region. Surpassing over 8
million cubic meters of concrete production per annum in Thailand and Vietnam in over 250 batching
plants, INSEE promotes sustainable and high-performing concrete solutions. This vast experience and
technical expertise is set to transform Sri Lanka’s construction industry to the highest standard in
sustainable development, while also focusing on performance based, value added and highly customized
concrete solutions.
Page: Page 5 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

3. Coarse Aggregate Test Reports.


3.1 5-20mm Aggregate Test Reports – Physical Properties
Page: Page 6 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 7 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 8 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 9 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 10 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 11 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 12 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 13 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 14 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

3.2 5-14mm Aggregate Test Reports – Physical Properties


Page: Page 15 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 16 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 17 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 18 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 19 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 20 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 21 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 22 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 23 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

3.3 Coarse Aggregate Test Reports – Chemical Properties


Page: Page 24 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 25 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 26 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 27 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

4. Fine Aggerate Test Reports.


4.1 Manufactured Sand Test Reports
Page: Page 28 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 29 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 30 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 31 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 32 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 33 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 34 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 35 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 36 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

4.2 River Sand Test Reports.


Page: Page 37 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 38 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 39 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 40 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 41 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 42 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 43 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

5. Cement Test Reports.


5.1 INSEE Extra (25% Fly Ash Blended PPC)
Page: Page 44 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 45 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 46 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 47 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 48 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 49 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 50 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 51 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 52 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 53 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

5.2 INSEE Rapid Flow Plus (15% Fly Ash Blended PPC)
Page: Page 54 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 55 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 56 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 57 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 58 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 59 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 60 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 61 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 62 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 63 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

5.3 INSEE Rapid Flow (OPC)


Page: Page 64 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 65 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 66 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 67 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 68 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 69 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 70 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 71 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 72 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 73 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 74 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

6. Water Test Report.


Page: Page 75 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


Page: Page 76 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete

7. Ice Test Report.


Page: Page 77 of 77

Date &
29-March-2022
Version:

Authored by INSEE Concrete


IJniversity of Colombo
Department of Chemistry
P. O. Box 1490, Colombo 03, Sri Lanka

Test Report

Report to : Chryso Lanka @vt) Ltd, 531/1, Mukalangarnuwa, Negombo


Road, Seeduwa.

Date of Issue |251101202t

Description of Test item

No of sarnples :01
Sample narne : CHRYSO@Optima ll00
Sample Ref. No : Sl202ll07l08

Lab. Ref. No z2l07l5

Test Results:

Test Parameter Method of Test Test Results

pH@27"C Potentiometry 4.85

Specific Gravity Specific gravity bottle method 1.08

Checked by Certified by

*1q0,*-
Dr. L. H. R. Perera Prof. K. M. Nalin de Silva
Coordinator/Analytical Services Head./Departrnent of Chemistry

' r;'i'..

Telephone: (9411) 2503367


LJniversity of Colombo
Department of Chemistry
P. O. Box 1490, Colombo 03, Sri Lanka

Test Report

Report to : Chryso Lanka @vt) Ltd, 53li 1, Mukalangamuwa, Negombo


Road Seeduwa.

Date of Issue | 25^Ot202t

Description of Test item

No of samples :01
Sample name : CIRYSO@Optima 1100
Sample Ref. Nb : 3/2027107108

Lab. Ref. No :210715

Test Results:

Test Parameter Method of Test Test Results

Water soluble chloride content,


BS EN 480-10 :1997 0.02
%(wlw)
Note : Accordhg to BS EN 480-10 :1997, where the chloride cotrtent is 3 0.10 % bymass the admixture may
be described as "Chloride ftee"

Checked by Certified by

*L ?@u,*
or. r. ffi-.
iere.a Prof. K. M. Nalin de Silva
Coordinator/Analflical Services Head/Departrnent of Chemistry

Telephone: (9411) 2503367


IJniversity of Colombo
Department of Chemistry
P. O. Box 1490, Colombo 03, Sri Larka

Test Reoort

Report to : Chryso La*a @vt) Ltd, 531/1, Mukalangamuwa, Negombo


Road, Seeduwa.

Date of Issue 225/10t2021

Description of Test item

No of samples :01
Sample name : CIRYSO@Optima 1100
Sanrple Ref. No : Sl202l/07108

Lab. Ref- No :210715

Test Results:

Test Parameter Method of Test Test Results

Solid Content, % (wlw) Loss on Drying 33.0

Checked by Certified by

il49'*
Dr. L. IfR. Peiera
Coordinator/Analytical Services
ez#
Prof. K. M. Nalin de Silva
Head./Deparhnent of Chemistry

Telephoner (94t1) 2503367


TNDUSTRIAT TECHNOTOGY tNSTTTUTE (tTt)
P O. Box, 787, 363, Bauddhaloka Mawuthu, Colo*bo-5.il
Telephone: +94 t l 2379800 Fax: +94 lt 2379850
l
120/44, Vidya Mawatha, Colombo 7, Sri Lanka.
Telephone: +94 11 2379800 Fax i +9411237gg50
503/4, Halbarawa Gardens, Thalahena, Malambe, Sri Lanka.
Telephone: +94 11 279j3OO Faxi +94 11 2379848

TEST REPORT

Report No. SS 2109607

Report to:

Chryso Lanka (P\,1) Ltd,


531/1, Mukalangamuwa,
Negombo Road,
Seeduwa.

Issued by:
Materials Laboratory,
Industrial Technology Institute,
363, Bauddhaloka Mawatha,
Colombo 07.

2021-10-27

TEE REPORT IS ISSIJED SUBJECT TO COI\DITIONS MENTIONED OVTNI ,IT, A ['


ReportNo. SS 2109607
Thc Rcport is issucd under the following conditions:

CONFIDENTIAIITY: Strict Confidentiality is maintaincd in ail interaclions with clients. 'l'he client must
-iechnology
no1 use the lndustrial Institute (TI) namc and / or data in any manner, which mighl cause harm
to the institule 's rcputation and / or business. Undcr no circumstances is the name of the institute, to bc
published either alonc or in association with that of any other party without prior written approval fiom the
Director Genaral ofthe Institute.
TEST/CALIBRATION METHODS: In the abscnce of a specific requesl from the customer, ITI will
adopt any apptopriate national/intcmational standard mcthod for conducting the tes/calibration. In the
abscnce/non acccssibility of standard methods, I'I'i may adopt any othcr relevant publishcd tesUcalibration
mothod or lollow a mcthod dcvcloped at I'11.
Tf ST/CALIBRATION REPORT: 1. The rcport is issued for the information of the customcr and shall
not be rcproduced in total or in part without the prior wriltcn authority of thc Director Genaral, ITI. Any
person or any party who alters or adds or delctcs or interpolatcs any provisions or words or lctters or
l-rgures shall be liable to legal action. 2. The report is not a Certificate of Quality. It only applies to the item
of the specific producVequipment tested/calibralcd or to the consignmcnVlofbalch ftom which a
rcprcsenlative sample has bcen drawn by l'Il. The results shall not be used to indicate or imply that they are
applicable to other similar itcms. In addilion such rcsults must not be used to indicatc or imply that ITI
approves, recommends or endorses thc manufacturer, supplier or user of such product/equipment or that
I'fI in any way guaranlccs the later performance of thc producUequipment. 3. Thc report fumished by ITI
shal1 not be uscd in any advertising or sales promolion wittrout the prior writtcn authority of the Director
Genaral I'fI.4.'l'he rcport is limited spccifically to thc item/s submitted unlcss otherwise mcntioned. 5.
Conformities to a standard specihcations may be mentioned as required by standard specification on
request by the cuslomcr. 6. Ihe ITI will not offcr any opinion/advisc or recommendation with respect to
the suitability or otherwise ofthe itcm for any application or use. Interprctation ofresults and professional
opinion and recommcndations if required should be requested by customer and will be provided for an
additional fee paid for by customcr. 7. lJnder no circumstances does thc ITI accept any liabilily or loss or
damagc caused by misuse of thc ITI report. Liability is limited to the fcc charged in casc of proven
ncgligcncc by the ITI.
COPIES OF REPORT: OnIy one copy of the report will be made availablc to the customer. Extra copies
if necessary could be rcquested by customer at the time if submission ofjob and will be provided on the
payment ofan extra charge. Additional copies ofthe report endorsed by the Authorized signatory,could be
madc available at the request ofthe customer within a period of01 year from the date ofissue ofreport, on
a written request by the customer and on payment of an extra charge. No third party can obtain such a report
wilhout written authorization from the customer to ITI.
QUERIES ON REPORT: Customer queries on reports will be entertained only up to a period of 01 year
from the datc of issue of the report.
Rll,'I'l.l,N1'ION OF' TItS'l' I'I'IIMS: Perishable items will bc destroyed immediatcly after testing, other
items alter 01 month from the date of issue of the report.
RETURN Of'TEST ITEMS: Test items wili be returned to the oustomcr at the sole discrction of the I'11
only on a written request by the customer.
LOSS OR DAMAGE: While the ITI cxercises every care in respect of work entrusted to the Institute by
customers, the Institute is not liable for any loss/damage howsoever caused to person/property, including
property enkusted by customer to the Institute whether such loss, damage or delay may have been causcd
by reasons beyond the control of the Institute or otherwise.
LITIGATION: A1l costs associated with litigation or dispute for oral or written lestimony or preparation
of ipqilo or for any other purpose rclated to work provided by the ITI sha1l bc paid by the customer. Such
costs include, but are not limited to howly charges, travel and accommodation, mileage, counscl, lega1 fees
and all other expenses associated with the said litigation and dispute.
CIIANGE OX' CONDITIONS: ITI may at its sole discretion add to or amend thc conditions of this report
at the time of issue of the report and such additions or amendments shal1 be binding on the customer.

March 20 l7 n n1 D-.-,-.-
... Continuation Sheet
TEST REPORT

ReportNo. SS 2109607

Customer: Test Item:


Chryso Lanka (Pvt) Ltd, Admixture
531/1, Mukalangamuwa,
Negombo Road, Service Requested:
Seeduwa. Customer's letter dated 2021 -01 -26

Description: Identification of Test Item:


One (01) test item. Test item was labelled as ;
Contained in a plastic can.
Sample Name : CHRYSO Optima 1100
(Approximate volurne 1L) - Sample Ref No :512021107114
Sample Quantity : 1.0 L
Customer : Chryso Lanka Pvt Ltd
Sample Submitted Date : 27 ,07 .2021

Date of Receipt of Test Item:


2021-07-27
Test Dates: From 2021-10-13 to 2021-10-25

TEST RESULTS:

Test / Unit Test Method Results


Control Sample Cement i Adnlixture
(Only cement) (Dosage 100 l(g :1 l(g)
1. Setting time at27+2oC / minutes

(a). Initial BS EN 229 > 490


480 - 2 :2006
(b). Final 296 > 490

Test / Unit Test Method Results Requirements


BSEN934 -2t2001
2.Total alkali content equivalent as Na2O/ BS EN 480 0.96 Not above the
% by mass Pan 12: 2005 manufacture's stated
Maximum.

Test was carried outby M. V. P.N. Somathilake, Research Technologist and Anusha Dassanayake,
.Assistant Research Technologist.
. ;.: .'' ,

Yilnarana
Authorized r,r*,ty
ffifil"5i8llffi
2021-10-27