Lab Ref.

No: 2022/294 Report No: CT/22/030_A

Doc No: BVLK/CSL/TR/CT/02_R1


Bureau Veritas Lanka (Pvt) Ltd.
Construction Services Laboratory
No 34, Sanchi Arachchi Gardens
St. Sebastian Hill, Colombo 12.

TEST REPORT OF CEMENT SAMPLE


China Harbour Engineering Company Limited
01. CLIENT Level 32, East Tower, World Trade Centre, Echelon
Square, Colombo.

02.LAB REF NO. 2022/294


03.REPORT NO. CT/22/030_A

04.PROJECT* Colombo Port City Development Project

05.EMPLOYER* CHEC Port City Colombo (Private) Limited


06.REFERENCE OF REQUISITION Letter Received on 16th of April 2022
07.DATE OF REPORT May 16, 2022
08.TEST PERIOD April 16, 2022- May 16,2022
Construction Services Laboratory
09.TESTING LABORATORY Bureau Veritas Lanka (Pvt) Ltd. & Material Laboratory,
Industrial Technology Institute

10.SAMPLE DESCRIPTION

a. Nos of Samples 01 Re-packed sample

b. Sample received on April 16, 2022

c. Cement Type* Blended Hydraulic Cement (BHC)

d. Strength Class* 42.5N

e. Brand Name* INSEE EXTRA

f. Date of sampling* April 15, 2022

g. Sampling location/source* Cement PPC Concrete Plant

h. Sample No* CPCDP – CEM- 0050 Port City

i. Condition of the bag Repack

j. Quantity received 13 kg approximately

k. Sample drawn by Client

### To be continued ###

Laboratory General Terms and Conditions as mentioned in Annex A. This report shall not be reproduced, except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only.
*Indicates information supplied by the customer for which the laboratory has no control.

Construction Services Laboratory, Bureau Veritas Lanka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo12.
Tel : +94 11 244 0950, +94 11 473 4325 Fax : +94 11 462 8629 E-mail:cmtlab.colombo@lk.bureauveritas.com
Page 1 of 3
Lab Ref. No: 2022/294 Report No: CT/22/030_A

TEST REPORT OF CEMENT SAMPLE

11.TESTS REQUESTED

1) Mechanical requirements
i. Compressive Strength: 2 days
ii. Compressive Strength: 28 days
2) Physical requirements
i. Initial Setting time
ii. Soundness (Expansion)
3) Chemical requirements
i. Alkali Limits

12.TEST SPECIFICATIONS*

No Testing Item Limits Codes

1 2 days compressive strength ≥ 10,0 MPa EN 196-1

≥ 42,5
2 28 days compressive strength EN 196-1
≤ 62,5 MPa

3 Initial Setting Time ≥ 60 Min EN 196-3

4 Soundness (expansion) ≤ 10 mm EN 196-3

5 Alkali Limit 0.60 % maximum EN 196-21

13.TEST METHODS

Code Title

EN 196 - 1 Test Methods for Cements- Determination of Strength


EN 196 – 3 Test Methods for Cements – Determination of Setting Time and Soundness
EN 196 - 21 Methods of Testing Cement Part 21: Determination of the Chloride, Carbon
Dioxide and Alkali Content of Cement

### To be continued ###

Laboratory General Terms and Conditions as mentioned in Annex A. This report shall not be reproduced, except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only.
*Indicates information supplied by the customer for which the laboratory has no control.

Construction Services Laboratory, Bureau Veritas Lanka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo12.
Tel : +94 11 244 0950, +94 11 473 4325 Fax : +94 11 462 8629 E-mail:cmtlab.colombo@lk.bureauveritas.com
Page 2 of 3
Lab Ref. No: 2022/294 Report No: CT/22/030_A

TEST REPORT OF CEMENT SAMPLE

14. TEST RESULTS

Serial
Parameter Unit Results Specification* Compliance
No
Mechanical Requirement
 Compressive Strength
19.4
19.6
21.3 Avg, Complies
i. Early Strength 2 Days N/mm2 ≥ 10.0
20.6 20.2
20.3
19.7
44.8
46.3
Avg,
2 45.8 ≥ 42.5
ii. Standard Strength: 28 days N/mm 46.4 Complies
45.9 ≤ 62.5
47.5
48.2
Physical Requirement
 Setting time
i. Initial Setting time min 202 ≥ 60 Complies
 Soundness mm 1.98 ≤ 10 Complies
Chemical requirements
 Alkali Limit % 0.28 0.60% maximum Complies

Sign for,
Construction Materials Testing Laboratory, Bureau Veritas Lanka (Pvt) Ltd.

Checked by: Authorized by:


T.H.S. Rathnayake K.G.N.T.Gamage
Chemist/ Deputy Technical Manager Laboratory Manager

########## End of Report ##########

Laboratory General Terms and Conditions as mentioned in Annex A. This report shall not be reproduced, except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only.
*Indicates information supplied by the customer for which the laboratory has no control.

Construction Services Laboratory, Bureau Veritas Lanka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo12.
Tel : +94 11 244 0950, +94 11 473 4325 Fax : +94 11 462 8629 E-mail:cmtlab.colombo@lk.bureauveritas.com
Page 3 of 3
Lab Ref. No: 2022/291 Report No: CT/22/031_A

Bureau Veritas Lanka (Pvt) Ltd. Doc No: BVLK/CSL/TR/CT/02_Rl

Construction Services Laboratory


No 34, Sanchi Arachchi Gardens
St. Sebastian Hill, Colombo 12.

TEST REPORT OF CEMENT SAMPLE


China Harbour Engineering Company Limited
01. CLIENT Level 32, East Tower, World Trade Centre, Echelon Square,
Colombo.

02.LAB REF NO. 2022/295

03.REPORT NO. CT/22/031_A

04.PROJECT* Colombo Port City Development Project

OS.EMPLOYER* CHEC Port City Colombo (Private) Limited

06.REFERENCE OF REQUISITION Letter Received on 11th of May 2022


07.DATE OF REPORT June 15 , 2022
08.TEST PERIOD May 10, 2022- June 10,2022
Construction Services Laboratory
09.TESTING LABORATORY Bureau Veritas Lanka (Pvt) Ltd. & Material Laboratory,
Industrial Technology Institute
JO.SAMPLE DESCRIPTION

a. Nos of Samples 01 Re-packed sample

b. Sample received on May 11, 2022

c. Cement Type* Blended Hydraulic Cement (BHC)

d. Strength Class* 42.5N

e. Brand Name* INSEE EXTRA

f. Date of sampling* May 09, 2022

g. Sampling location/source* Cement PPC Concrete Plant

h. Sample No* CPCDP – CEM- 0051 Port City

i. Condition of the bag 10 kg approximately

j. Quantity received
r��,.,,_-
�,r
.,rn;�Tini.
••v••-•·- •�• •
n'kiun•1�•
k ,uv,I ,·1�·'i•
� Construction Services Labon1tory
k. Sample drawn by Client No. 34, Sanchi Arachchi GardE1ns

ltll &
\'i�- �L �eoasuan n111 1 vv1v111uv 1.L, i>JI Lcul"".
Tel: +94112 440 948-50/+94114 734 325-6
#/#f. To be continued #/#f. �Fai_<: +94 114 628 629
�Email: cmllab.colombo@lk.bureauventas.com
REG. NO: PV 1550
Laboratory General Terms and Conditions as mentioned in Annex A This report shall not be reproduced , except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only,
*Indicates info rmation supplied by the customer fo r which the laboratory has no control.

Construction Services Laboratory, Bureau Veritas Ll!-nka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo 12.
Tel : +94 11 244 0950, +94 11 473 4325 Fax : +94 11 462 8629 E-mail:cmtlab.colombo@lk.bureauveritas.com
Page 1 of3
Lab Ref. No: 2022/291 Report No: CT/22/0 31_A

TEST REPORT OF CEMENT SAMPLE

11.TESTS REQUESTED

1) Mechanical requirements
I. Compressive Strength: 2 days
II. Compressive Strength: 28 days
2) Physical requirements
I. Initial Setting time
II. Soundness (Expansion)

3) Chemical requirements
I. Alkali Limits

12.TEST SPECIFICATIONS*

No Testing Item Limits Codes

1 2 days compressive strength :C: 10,0 MPa EN 196-1

:C: 42,5
2 28 days compressive strength EN 196-1
:S 62,5 MPa

3 Initial Setting Time :C: 60Min EN 196-3

4 Soundness (expansion) :S 10 mm EN 196-3

5 Alkali Limit 0.60 % maximum EN 196-21

13.TEST METHODS

Code Title

EN 196 - 1 Test Methods for Cements- Determination of Strength


EN 196-3 Test Methods for Cements-Determination of Setting Time and Soundness
EN 196 - 21 Methods of Testing Cement Part 21: Determination of the Chloride, Carbon
Dioxide and Alkali Content of Cement

I
#:f:1:#. To be continued #:f:1:#. i O
BU!i!iiiivER iASLAllKA IPV f) LI:
Construction Services �aborntory,
No. 34, Sanchl Arachch1 Garde,,s,
SL Sebastian Hill, Colombo 12, Sri Lanka.
Tel: +94112 440 948·50 /+94114 734 325-6

WJJJtn
Fax: +94 114 628 629
[l!JJ Email: cmtlab.colombo@lk.bureauveritas.com
.
REG. NO: PV 1550

Laboratory General Terms and Conditions as mentioned in Annex A This report shall not be reproduced, except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only.
*Indicates information supplied by the customer for which the laboratory has no control.

Construction Services Laboratory, Bureau Veritas Lanka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo I 2.
Tel : +94 11 244 0950, +94 11 4 73 4325 Fax : +94 l l 462 8629 E-mail:cmtlab.colombo@lk.bureauveritas.com
Page 2 of3
Lab Ref. No: 2022/291 Report No: CT/22/031_A

TEST REPORT OF CEMENT SAMPLE

14. TEST RESULTS

Serial
Parameter Unit Results Specification* Compliance
No
Mechanical Requirement
• Compressive Strength

20.8
22.0
20.6 Avg, Complies
I. Early Strength 2 Days N/mm2 > 10.0
-
21.7 21.1
20.8
20.7
48.6
51.4
50.9 Avg, 2': 42.5
II. Standard Strength: 28 days N/mm2 Complies
49.7 50.4 :'.S 62.5
49.9
51.6
Physical Requirement
• Setting time
I. Initial Setting time min 202 :::: 60 Complies
• Soundness mm 1.7 :'.S 10 Complies
Chemical requirements
• Alkali Limit % 0.26 0.60% maximum Complies

Sign for,
Construction Materials Testing Laboratory, Bureau Veritas Lanka (Pvt) Ltd.

Checked by:

.
:
Authorized by: ......
;J¥.. . . . .
' >

T.H.S. Rathnayake K.G.N.T.Gamage


Deputy Technical Manager Laboratory Manager
��VERITAS LANN\ \PY f) LTD.
� Construction Services Labor�tory,
" No. 34, Sanchi Arachchi Gardens,
· St. Sebastian Hill, Colombo 12, Sri Lanka.
, o,. Tel: +94112 440 948·50 /+94 114 734 325-6
+94114 628 629
HIJiH·\iTilFa�:
EmQII: cmtlab.colombo@lk.bureauventas.com
[l1U{;«'ji'IJJ
REG. NO: PV 1550
Laboratory General Terms and Conditions as mentioned in Annex A. This report shall not be reproduced, except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only.
*Indicates information supplied by the customer for which the laboratory has no control.

Construction Services Laboratory, Bureau Yeritas Lanka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo12.
Tel : +94 11 244 0950, +94 11 473 4325 Fax: +94 11 462 8629 E-mail:cmtlab.colombo@lk.bureauveritas.com
Page 3 of3
Lab Ref. No: 2022/292 Report No: CT/22/032_A

Bureau Veritas Lanka (Pvt) Ltd. Doc No: BVLK/CSL/TR/CT/02_Rl

Construction Services Laboratory


No 34, Sanchi Arachchi Gardens
St. Sebastian Hill, Colombo 12.
B!l;IU!I
l!l=i;lll·f..._
TEST REPORT OF CEMENT SAMPLE
China Harbour Engineering Company Limited
01. CLIENT Level 32,East Tower, World Trade Centre,Echelon
Square,Colombo.

02.LAB REF NO. 2022/296

03.REPORT NO. CT/22/032_A

04.PROJECT* Colombo Port City Development Project

OS.EMPLOYER* CHEC Port City Colombo (Private) Limited


06.REFERENCE OF REQUISITION Letter Received on 13th of June 2022
07.0ATE OF REPORT July 13, 2021
08.TEST PERIOD June 13, 2022- July 13,2022
Construction Services Laboratory
09.TESTING LABORATORY Bureau Veritas Lanka (Pvt) Ltd. & Material Laboratory,
Industrial Technology Institute
IO.SAMPLE DESCRIPTION

a. Nos of Samples 01 Re-packed sample

b. Sample received on June 13,2022

c. Cement Type* Blended Hydraulic Cement (BHC)

d. Strength Class* 42.SN

e. Brand Name* INSEE EXTRA

f. Date of sampling* June10,2022

g. Sampling location/source* Cement PPC Concrete Plant

h. Sample No* CPCDP – CEM- 0052 Port City

i. Condition of the bag Repack

j. Quantity received 12 kg approximately

k. Sample drawn b_y Client

T
### To be continued### �::--BUREAi VER!i'As LANKA (r'Vf) l'rD.
Construction Services Laboratory,
No. 34, Sanchi Arachchi Gardens,
St Sebastian Hill, Colombo 12, Sri Lanka.
Labora tory General Terms and Condit ions as ment ioned in Annex A Th is report sh all not be reproduced, e c , Xf<illiVJ41Ji,u;iijll@.51111ll:)JjVjlj�ml! atory
Sampling not done by th e laboratory and result relates to sample tested only.
*Indicates informat ion supplied by th e customer for wh ich th e laboratory h as no control. mllll.ll
� Fax: +94114 628 629
Em�II: cmllab.colombo@lk.bureauveritas.com
REG. NO: PV 1550
Construction Services Laboratory, Bureau Veritas Lanka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo 12.
Tel : +94 11 244 0950, +94 11 473 4325 Fax : +94 I I 462 8629 E-maiI :cmtl ab.colornbo@I k.bureau veritas.com
Page 1 of3
Lab Ref No: 2022/292 Report No: CT/22/032_A

TEST REPORT OF CEMENT SAMPLE

11.TESTS REQU�STED

1) Mechanical requirements
1. Compressive Strength: 2 days
11. Compressive Strength: 28 days
2) Physical requirements
I. Initial Setting time
II. Soundness (Expansion)

3) Chymical requirements
I. Alkali Limits

12.TEST SPECIFICATIONS*

No Testing Item Limits Codes

1 2 days compressive strength 2': 10,0 MPa EN 196-1


V

2': 42,5
2 28 days compressive strength EN 196-1
:S 62,5 MPa

3 Initial Setting Time 2': 60Min EN 196-3

4 Soundn�ss (expansion) :S 10 mm EN 196-3

5 Alkali Limit 0.60 % maximum EN 196-21

13.TEST METHODS

Code Title

EN 196 - 1 Test Methods for Cements- Determination of Strength


EN 196- 3 I
Test Methods for Cements- Determination of Setting Time and Soundness
EN 196 - 21 Methods of Testing Cement Part 21: Determination of the Chloride, Carbon
Dioxide and Alkali Content of Cement

### To be continued · �,,· BUREAVVERITAsLANKA (PVT) LTD.



r�. · ·
ft� Construction Services Laboratory,
; :;: No. 34, Sanchi Arachchi Gardens,
St Sebastian Hill, Colombo 12, Sri Lanka.
�' • Tel: +94 112 440 948·50 /+94114 734 325-6
ffl\;J:� Fa�: +94 114 628 629
=•�
mr,Fwc� Email: cmtlab.colombo@lk.buroauventas.com
-�•··•-.. ·· REG. NO: PV 1550 ,,..,_
Laboratory General Terms and Conditions as mentioned in Annex A This report shall not be reproduced, except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only.
*Indicates information supplied by the customer for which the laboratory has no control.

Construction Services Laboratory, Bureau Veritas. Lanka (Pvt) Ltd., No 34, Sanchi Arachchi Gardens, St. Sebastian Hill, Colombo 12.
Tel : +94 11 244 0950, +94 11 473 4325 Fax : +94 11 462 8629 E-mail:cmtlab.colombo@lk.bureauveritas.com
Page 2 of3
Lab Ref No: 2022/292 Report No: CT/22/032_A

TEST REPORT OF CEMENT SAMPLE

14. TEST RESULTS

Serial
Parameter Unit Results Specification* Compliance
No
Mechanical Requirement
• Compressive Strength

21.7
20.8 Avg,
I. Early St;ength 2 Days N/mm2 20.6 > 10.0 Complies
20.8 21.0
21.6
20.6
49.7
' 48.7 Avg, 2: 42.5
II. Standard Strength: 28 days N/mm 2 51.4
Complies
49.9 49.6 :S 62.5
47.9
49.8
Physical Requirement
• Setting time
I. Initial Setting time mm 209 2: 60 Complies
• Soundness mm 1.09 :s 10 Complies
Chemical requirements
• Alkali Limit % 0.23 0.60% maximum Complies

Sign for,
Construction Materials Testing Laboratory, Bureau Veritas Lanka (Pvt) Ltd.

Checked by: ... �.. Authodzed by: .... �.


T.H.S. Rathnayake K.G.N.T.Gamage
,Deputy Technical Manager Laboratory Manager

####tt##### End of Report #1#/:#######


►", -� BUREAU VERITAS LANV-A (PVT)LTD.
� Construction Services Laboratory,
· � No. 34, Sanchi Arachchi Gardens,
"lJ,,1 · St. Sebastian Hill, Colombo 12, Sri Lanka.
• I , �,_!.. fol: +94 112 440 948-50 /+94 114 734 325-6
lllWll
lllJrlll"IJDJ! Fax: +94 114 628 629
ErMil : cmllab.colombo@lk.bureauveritas.com
-· ...._REG.NO: PV1550_____,

Laboratory General Terms and Conditions as mentioned in Annex A This report shall not be reproduced, except in full, without the written approval of the laboratory
Sampling not done by the laboratory and result relates to sample tested only.
*Indicates information supplied by the customer for which the laboratory has no control.