3.1 MCCB
3.1.01 Make
3.1.02 Model
3.1.03 Country of origine
3.1.04 No. of poles 4
3.1.05 Rated current A 63
3.1.06 Rated service voltage V 400
3.1.07 Rated insulation voltage V
1
REF. DESCRIPTION PARTICULARS
UNITS
As specified As offered
3.1.08 Rated impulse withstand voltage kV
3.1.09 Breaking capacity kA 50
3.1.10 Trip unit adjustment range
3.1.10.1 Thermal x In
3.1.10.2 Magnetic x In
3.1.11 Applicable standard BS EN 60947-2
3.3 MCB
3.3.01 Make
3.3.02 Model
3.3.03 Country of origine
3.3.04 No. of poles 4
3.3.05 Rated current A 20
3.3.06 Rated service voltage V 400
3.3.07 Rated insulation voltage V
3.3.08 Rated impulse withstand voltage kV
3.3.09 Breaking capacity kA 6,10
3.3.10 Trip unit adjustment range
3.3.10.1 Thermal x In
3.3.10.2 Magnetic x In
3.3.11 Applicable standard BS EN 60898
3.4 MCB
3.4.01 Make
3.4.02 Model
3.4.03 Country of origine
3.4.04 No. of poles 3
3.4.05 Rated current A 32
3.4.06 Rated service voltage V 400
3.4.07 Rated insulation voltage V
3.4.08 Rated impulse withstand voltage kV
3.4.09 Breaking capacity kA 6,10
3.4.10 Trip unit adjustment range
3.4.10.1 Thermal x In
3.4.10.2 Magnetic x In
3.4.11 Applicable standard BS EN 60898
3.5 MCB
2
REF. DESCRIPTION PARTICULARS
UNITS
As specified As offered
3.5.01 Make
3.5.02 Model
3.5.03 Country of origine
3.5.04 No. of poles 1
3.5.05 Rated current A 6,16
3.5.06 Rated service voltage V 230
3.5.07 Rated insulation voltage V
3.5.08 Rated impulse withstand voltage kV
3.5.09 Breaking capacity kA 6,10
3.5.10 Trip unit adjustment range
3.5.10.1 Thermal x In
3.5.10.2 Magnetic x In
3.5.11 Applicable standard BS EN 60898
6.1 RCCB
6.1.1 Make
6.1.2 Model
6.1.3 Country of origine
6.1.4 No. of poles 4
6.1.5 Rated current A 63
6.1.6 Rated service voltage V 400
3
REF. DESCRIPTION PARTICULARS
UNITS
As specified As offered
6.1.7 Rated insulation voltage V
6.1.8 Sensitivity mA 100
6.1.9 Applicable standard BS EN 61008-1
6.2 RCCB
6.2.1 Make
6.2.2 Model
6.2.3 Country of origine
6.2.4 No. of poles 4
6.2.5 Rated current A 40
6.2.6 Rated service voltage V 400
6.2.7 Rated insulation voltage V
6.2.8 Sensitivity mA 100
6.2.9 Applicable standard BS EN 61008-1
6.3 RCCB
6.3.1 Make
6.3.2 Model
6.3.3 Country of origine
6.3.4 No. of poles 2
6.3.5 Rated current A 40
6.3.6 Rated service voltage V 230
6.3.7 Rated insulation voltage V
6.3.8 Sensitivity mA 100
6.3.9 Applicable standard BS EN 61008-1
6.4 RCCB
6.4.1 Make
6.4.2 Model
6.4.3 Country of origine
6.4.4 No. of poles 2
6.4.5 Rated current A 40
6.4.6 Rated service voltage V 230
6.4.7 Rated insulation voltage V
6.4.8 Sensitivity mA 30
6.4.9 Applicable standard BS EN 61008-1
4
REF. DESCRIPTION PARTICULARS
UNITS
As specified As offered
6.6.6.3 Active power YES/NO YES
6.6.6.4 Apparent power YES/NO YES
6.6.6.5 Reactive power YES/NO YES
6.6.6.6 Total energy consumption YES/NO YES
6.6.6.7 Frequency YES/NO YES
6.6.7 Applicable standard IEC 60253
7 Surge Arrestor
7.01 Make
7.02 Manufacture
7.03 Country of Origin
7.04 Type
Metal Oxide Varistor (MOV)
type
7.05 Maximum Discharge Current kA 50
7.06 Rated Surge Current kA 40(minimum)
7.07 Protection Level kV ( <1.3 & <0.8 )
7.08 Applicable Standards BS or equivalent
7.09 Agent
7.10 Warranty Yrs
8.1 Isolators
8.1.1 Make
8.1.2 Model
8.1.3 Country of origine
8.1.4 No. of poles 4
8.1.5 Rated current A 40
8.1.6 Rated service voltage V 400
8.1.7 Rated insulation voltage V
8.1.8 Rated impulse withstand voltage kV
8.1.9 Breaking capacity kA
8.1.10 Applicable standard IEC 60129
8.2 Isolators
8.2.1 Make
8.2.2 Model
8.2.3 Country of origine
8.2.4 No. of poles 4
8.2.5 Rated current A 32
8.2.6 Rated service voltage V 400
8.2.7 Rated insulation voltage V
8.2.8 Rated impulse withstand voltage kV
8.2.9 Breaking capacity kA
8.2.10 Applicable standard IEC 60129
8.3 Isolators
8.3.1 Make
8.3.2 Model
8.3.3 Country of origine
8.3.4 No. of poles 2
8.3.5 Rated current A 40
8.3.6 Rated service voltage V 230
8.3.7 Rated insulation voltage V
8.3.8 Rated impulse withstand voltage kV
8.3.9 Breaking capacity kA
8.3.10 Applicable standard IEC 60129
5
REF. DESCRIPTION PARTICULARS
UNITS
As specified As offered
8.4 Isolators
8.4.1 Make
8.4.2 Model
8.4.3 Country of origine
8.4.4 No. of poles 2
8.4.5 Rated current A 32
8.4.6 Rated service voltage V 230
8.4.7 Rated insulation voltage V
8.4.8 Rated impulse withstand voltage kV
8.4.9 Breaking capacity kA
8.4.10 Applicable standard IEC 60129
10.1 Switches
10.1.1 Make
Orange(X7/X8), Clipsal,
ACL, Legrand or eq
10.1.2 Model
10.1.3 Country of origine Sri Lanka, France,
Europe, Japan or eq
10.1.4 Rated current A
10.1.5 Rated service voltage V
10.1.6 Available colours for cover plate 1. White
2. Black
10.1.7 Applicable standard BS 60669-1
11.1 Cables
11.1.1 PVC Cable
11.1.2 Type Cu/PVC/PVC
11.1.3 Designed current A
11.1.4 Cross-section area mm2 according to the BOQ
11.1.5 Number of cores Nos. 1 or 2 or 4
11.1.6 Number of cables
11.1.7 Insulation
11.1.8 Operating Voltage V
11.1.9 Voltage drop %
11.1.10 Method of Installation PVC casing
11.1.11 Applicable standard BS 6004