: MTPL/RCA/01
ROOT CAUSE ANALYSIS REPORT (RCA) Rev: 00
Date: 15/05/2020
Brief Description of BD On 07-09-2023 at 07:31AM Inverter -3 tripped on Insulation resistance Failure and Engineer observed fire with smoke and cable
puncture at Inverter-3 SCB 8 &17 field area. Team done IR test for all SCB outgoing Dc cables pertaining to inverter3, found all SCB
cables IR values were satisfactory except SCB 8 and 17.
Breakdown Brief History : On 07-09-2023 at 07:31AM Inverter -3 tripped on Insulation resistance Failure and Engineer observed smoke and cable puncture at Inverter-3 SCB 8
C]
&17 field area. Team done IR test for all SCB outgoing DC cables pertaining to inverter-3, found all SCB cables IR values were satisfactory except SCB 8 and 17.
Date Of Failure / Observation 07-09-2023 07:31 Hrs Correction completed on: 08-09-2023 05:45AM
D] Failure details:
Component Name Inverter -3 SCB 8 & 17 300 Sq.mm SCB OUT going cables Make/Supplier Name Polycab
Component Type 1.8KV DC Cable Component Part No. NA
E] Breakdown Analysis :
Problem Description Suspected Reasons of Failure
Sr. Corrective Action Carried Out Remark
(Observations of Anomalies) (Why, Why Analysis )
1. Inverter-3 SCB 8 &17 positive and negative Why 1:Pin hole/scratches happend during errection time may lead to damage of outer sheath of cable.
cable both punctured . Why 2:Quality of Cable.
Why 3:Improper Cable backfilling and bedding
2. MCS pipeline damaged at SCB 17 Why 4:Ingress of moisture into cable insulation layer
Why 5:Bunch of cables irrespective of cable size in same trench
3.OFC cable for SCADA from ICR 4 to ICR 3 Why 6:MCS pipeline is on the DC cable with approx. 1.5 feet gap
1. Excavated the cable trench, found
damaged .
SCB 8 &17 positive and negative cable
punctured.
4. Fire catches to all strings cable pertaining to
2.Checked the cable IR values of both
SCB 8& 17 along with approx 24 moduels
SCB positive and negative cables after
carbonized and need to test modules for
removing punctured portion
helathyness as some were physically damaged
3.Found both cables IR values are
1 too.
satisfactory.
4. Then cable Jointing done.
5.After jointing IR values are taken and
found ok and connected to inverter.
6. SCB 8 & 17 taken into full load
7.Aside, OFC cable splicing done and
ICR 4 communication restored.
Photograph evidences:
Major Root Cause Analysis Identified : Moisture ingression into cable insulation layer due to pin holes or improper DC trenching aswell cable undergrounded irrespective of polarity and size.
Highlights : Kaizen / Any Change or major modification suggested / Manufacturer comments if any: - Need to provide separate route and trench for cables with respective size, polarity as well as for MCS pipe line
1 OF 3
ANNEXURE-1: WHY WHY ANALYSIS
SCB outgoing DC cable 300 Sqmm failure