0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

220V SOURCE
A

CPU315 /

Load supply voltage 120/230VAC:24VDC/10A


PS 307 10A
6ES7 307-1KA02-0AA0
SF
SIEMENS

_
L1
_
B DC 5V

FRCE

6ES7215-1AG40-0XB0
CPU 1215C DC/DC/DC
RUN

N STOP
PUSH

MRES
RUN
STOP
C PE
SIMATIC
S7-300

part 1 of 4
Jumper
D 120VAC
Only
6ES7 315-2EH14-0AB0
M
X 2
24 VDC
3 4 L+

L+
E

Module 1
M

F
M

_
G

Author: M.Bakry File: DPM wiring


DPM Mashhour
Date: 10/8/2023 Folio: 1/7
E

F
B

C
A

H
D
SM331
0

AI 8x12BIT

SF
CH0:IW288 0

_
1

Author: M.Bakry
_

Date: 10/8/2023
CH1: IW290 2
3
1

_ _
4 _
CH2: IW292
5 _
CH3 :IW294 6 _

_ _
7

_
2

_ _
0
3

_ _
2 1
CH5 :IW298 _
3

_
2
_

4 ladder angle sensor input

_
5 3 0-20mA
4

_
6

__ _
4
7 _
X 4 5
5 6

_ _
_
331-1KF02-0AB0
6
5

draft sensor
7 0-20mA
_

_ 8
_
9
6

_
10
_

spud carriage position


11 4-20mA

_
12
7

_
_
13
S7-1200, Module Sm1231. _
4 AI U/A 14
_

mixture Speed
_

15 4-20mA
8

X10
_

L+ 16
_
24v DC
M IN

analog input signals 1


9

PE
_

X10
=<40mA
4-20mA
_

0+

4-20mA
0-

CH0:IW68
*EW *EW
10

=<40mA
_

4-20mA
1+
_

4-20mA
1-

CH1:IW70
*EW *EW
11

X11
=<40mA
4-20mA
2+

4-20mA
2-

CH2:IW72
12

*EW *EW

=<40mA
4-20mA
3+

4-20mA
3-

CH3:IW74
13

*EW *EW

Folio: 2/7
14

File: DPM wiring


15
16
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

B S7-1200, Module Sm1231.


4 AI U/A

X10
L+
24v DC
M IN

C
PE
X10
=<40mA
4-20mA
0+ *EW

24 23 22 21 20 19 18 17
4-20mA
0- *EW CH4:IW76 _ vaccum
_ pressure
_ _
D =<40mA
4-20mA
1+ *EW _ submerged
_ pump pressure
4-20mA
1- *EW CH5:IW78 _

_ DP1
_ pressure
X11
_
E =<40mA
4-20mA
2+ *EW
4-20mA
DP2
_ pressure
2- *EW CH6:IW80 _
_
_
=<40mA
4-20mA
3+ *EW
F 4-20mA
3- *EW CH7:IW82 _

Author: M.Bakry File: DPM wiring


analog inputs signals 2
Date: 10/10/2023 Folio: 3/7
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

L+
24VDC
SM 1232 AQ4x14bits 6ES7 234-4HE32-0XB0

M
B

30 29 28 27 26 25
0+

_
CH0:QW112
_
C
0-

_ spud carrier speed 0-10V


_
1+

CH1:QW114
ANALOG OUTPUTS

D
1-
2+

CH2:QW116

_
E

_
2-
3+

CH3:QW118
F
3-

G L+
10 9 8 7 6 5 4 3 2 1

QW310 QW308 QW306 QW304

/
Analog output module AO4 x U/I 16bits 6ES7 332-7ND02-0AB0
H

Author: M.Bakry File: DPM wiring


analog output signals
Date: 10/10/2023 Folio: 4/7
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

6ES7 321-1BH02-0AA0 DI 16 x DC24V part 1 of 2

B /
I0.7 I0.6 I0.5 I0.4 I0.3 I0.2 I0.1 I0.0
10 9 8 7 6 5 4 3 2 1

carriage forward

46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31
_ carriage forward
C
_ carriage back
_ carriage back
_ reset hydraulic
D _ reset hydraulic
_ hydraulic pump ready
_ hydraulic pump ready
_ spud carrier end position
E _ spud carrier end position
_ cutter mode
_ cutter mode
_ Hofer unit ready
F Hofer valve
_ opened
_

G
1M 16.0 16.1 16.2 16.3 2M 16.4 16.5 16.6 16.7
DI a
24 V DC INPUTS

6ES7 221-1BH32-0XB0 DI 8 x DC24V part 1 of 2


H

Author: M.Bakry File: DPM wiring


digital input signals 1
Date: 10/10/2023 Folio: 5/7
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A
6ES7 321-1BH02-0AA0 DI 16 x DC24V part 2 of 2

/
M I1.7 I1.6 I1.5 I1.4 I1.3 I1.2 I1.1 I1.0
B 20 19 18 17 16 15 14 13 12 11

Hofer valve closed

62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47
_
C

G 17.0
3M 17.1 17.2 17.3 4M 17.4 17.5 17.6 17.7
DI b
24 V DC INPUTS

6ES7 221-1BH32-0XB0 DI 8 x DC24V part 2 of 2


H

Author: M.Bakry File: DPM wiring


digital input signals 2
Date: 10/10/2023 Folio: 6/7
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A 6ES7 222-1BH32-0XB0 part 1 of 2 24 VDC


L+

B
20.0

70 69 68 67 66 65 64 63
Carriage step Forward

Carriage step Backward


DQ a

C
20.1
Siren
RELAY OUTPUTS

hofer alarm output


_
D
20.2

_
_
E

_
20.3

10 9 8 7 6 5 4 3 2 1

1M Q2.7 Q2.6 Q2.5 Q2.4 Q2.3 Q2.2 Q2.1 Q2.0 1L+

H /
6ES7 322-1BH01-0AA0 DO 16 x DC24V/0,5A part 1 of 2

Author: M.Bakry File: DPM wiring


digital output signals 1
Date: 10/8/2023 Folio: 7/7