Professional Documents
Culture Documents
NO VB-QC-SOP-011
REV. NO 0
REV. DATE 01 OCTOBER 2023
PAGE 1 OF 4 PAGES
STANDARD OPERATING
TITLE : OIL (UCO/EFB/POME/MEF) RECEIVING - LOCAL TANKER PROCEDURE
1.0 Drain 1 pail (35kg) and draw sample in 2.1 Operation personnel shall conduct
Unloading Operator spin test for the sample drawn in 1.0 .
1x250ml plastic bottle from bottom tanker
discharge point. 2.2, 5.1, 8.1 Spin Test by centrifuge:
Place 15 ml sample inside a tube &
heat in water bath 80°C for 2 minutes.
Centrifuge at 4000RPM for 2 minutes.
Compare centrifuged tube against the
2.0 Tests and YES printed reference that is provided by
Unloading Operator QC.
approval
Approval:
Passed : Less than 0.3ml (2%)
NO Failed : More than 0.3ml (2%)
Unloading Operator
3.0 Drain 3 pails (100kg) . 3.1, 6.1 Loading operator to initiate the
Indicated as 1st drain. draining activity when the result for
spin test failed. Loading operator must
always monitor the draining process.
NO
NO
A B
STANDARD OPERATING
TITLE : OIL (UCO/EFB/POME/MEF) RECEIVING - LOCAL TANKER PROCEDURE
A B
9.1 Unloading operator to initiate the
draining activity when the result for
spin test failed. Unloading operator
Unloading Operator 9.0 Drain 3 pails (100kg) . must always monitor the draining
Indicated as 3rd drain. process.
C FFA , M&I,
15.0 Lab to conduct IV, Mineral Oil, Ester Content , ICP
full analysis for
approval
18.0 Trader to respond acceptance within 2 18.1 Trader to respond via email
Trader sent by chemist in 17.0
hours after email sent
YES
21.0 Trader
required to
Trader obtain approval
from
GM/Director 23.1 QC to advice the tested quality
to production engineer/executive.
END
24.0 Lab technician to conduct analysis based on 24.2 Full analysis : Parameter to be tested
Lab technician / according to sequence:
sample status. FFA , M&I, IV, Mineral Oil, Ester Content ,
Chemist ICP.
Basic analysis : FFA , M&I, IV, Mineral Oil ,
26.0 Give 25.1 Chemist to verify and confirm the
Lab technician / YES discharge failed test results before proceed to the
25.0 Test results next step.
Chemist approval to
operation team / 25.2 Retain sample to be kept for 1 month
period by lab.
NO unloading
operator via 27.1 Rejection email to be sent to
<rejectoil@vancebioenergy.com> must be
walkie talkie and attached with rejection form and photos of
Lab technician / 27.0 Chemist to notify trader Operation/QC Spin test and Shake Test for sample
via email and WhatsApp Whatsapp Group. which sent to the laboratory.
Chemist
group (UCO quality) 27.2 Chemist to inform and highlight the
rejection issue to HOD via call and also to
GM/Director via VBSB QC Dept Skype
Chat.
29.0 Reject NO
acceptance 33.1 QC to advice the tested quality to
production engineer/executive.
YES
END
Production / unloading 33.0 Production to decide
operator on discharge strategy.
END
PREPARED BY CHECKED BY APPROVED BY