Coc - WPCA - v12.03 - ACTx
Coc - WPCA - v12.03 - ACTx
v12.03_ACTx_short
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 1
NKT Accessories: Power cable accessories for wind applications
We offer a premium portfolio of cable accessories for AC power wind systems from 36 – 145 kV.
Onshore wind
Offshore wind
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 2
Accessories portfolio overview: 72kV
T-Connector Coupling-
Products
(outer cone) Connector
T-Connectors (outer cone)
Coupling-Connectors
Dead-end plugs
Bushings
Inner Cone Connectors Termination
Joints
Surge arresters systems Surge
Termination Systems arrester
Pre-terminated cables
Assembly tools
(outer cone)
Pre-
terminated Connector
cables (inner cone)
Joints
Assembly
tools
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 3
Product portfolio for offshore applications
From MV to EHV
T-Connector Coupling-
(outer cone) Connector
(outer
cone)
Termination Surge
systems arrester
(outer
cone)
Pre-
terminated Connector
cables (inner
cone)
Joints
1 Assembly 10
tools
5
2
8
6 9
3
4 7
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 4
Product portfolio for offshore applications
From MV to EHV
T-Connector Coupling-
(outer cone) Connector
(outer
cone)
Termination Surge
systems arrester
(outer
cone)
Pre-
terminated Connector
cables (inner
cone)
Joints
1 Assembly 10
tools
5
2
8
6 9
3
4 7
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 5
Product portfolio for offshore applications
Nordenham the competence centre in power cable accessories for offshore wind farms
Nordenham
With more then 70 years of experience in development and manufacturing of power cable
accessories NKT has delivered accessories for more then 5.000 offshore turbines.
With the concentration of
• R&D,
• Product management,
• Tool shop for injection molding tools,
• Test lab’s,
• Customer service
• and operations, which is located in a new factory hall inaugurated in 2012
NKT offers a wide and complete portfolio of standard products as well as a high number of
customer specific design solutions.
Externally audited systems for quality control ISO 9001 and ISO 14001 combined with an
Energy Management system acc. to ISO 50001 ensure a continuous high-quality standard
of our products.
Training courses for jointers and trainers together with supervisions of installations are
fundamental part of our customer service. Factory opening in 1949
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 7
Product portfolio for offshore applications
Nordenham the competence centre in power cable accessories for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 8
Offshore Cable
Accessories
Norms and Regulations
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 9
Norms and Regulations for offshore cable accessories
Voltage levels
According to DIN VDE 0298 and IEC 183 the cables are specified U0/U, were
U0 = nominal voltage between the conductor and the metal covering or earth and
U = nominal voltage between the phase conductors, for 3-phase U = √3 U0.
According to IEC regulations, the maximum permissible voltage Um is given in brackets.
The identification is: U0/U/(Um).
U0/U/(Um)
18/30-33/(36) kV U(Um) max. voltage between conductors
U0/U/(Um)
76/132…138/(145) kV
In this presentation “36kV” stands for: 18/30-33/(36) kV and “72kV” stands for 36/60..66..69/(72,5) kV “145kV” stands
for 76/132…138/(145) kV
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 10
Accessories portfolio overview: 72kV
T-Connector Coupling-
Products
(outer cone) Connector
T-Connectors (outer cone)
Coupling-Connectors
Dead-end plugs
Bushings
Inner Cone Connectors Termination
Joints
Surge arresters systems Surge
Termination Systems arrester
Pre-terminated cables (outer cone)
Assembly tools
Pre-
terminated Connector
cables (inner cone)
Joints
Assembly
tools
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 11
Product portfolio for offshore applications
72kV – Termination Systems
T-Connector Coupling-
(outer cone) Connector
(outer
cone)
Termination Surge
systems arrester
(outer
cone)
Pre-
terminated Connector
cables (inner
cone)
Joints
1 Assembly
tools
5
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 12
Termination systems for offshore wind farms
.
ACTB
.
ACTR
ACTR-I ACTS-I
ACTS-Y
ACTS-H
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 13
Termination systems for offshore wind farms
The challenge – what is the most efficient setup for YOUR project?
YOUR
I II III IV V VI project
2 2 2 2 2 2 2
?
1) Source picture switchgear / Energy.siemens.com
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 14
Termination systems for offshore wind farms
The challenge – what is the most efficient setup for YOUR project?
I II III IV V VI VII
• Even if it looks so, this may not always be the most efficient solution in regards to:
2
The challenge – what is the most efficient setup for YOUR project?
I II III IV V VI VII
Think about
2 the time it takes to de-armor >20m of additional subsea cable
the logistic required for the jointers to get on and off the foundation
to get the scrap of the de-armoring back to the OSS and then further to onshore
the stiffness of subsea cables compared to pre-terminated cables with class 5 conductors
the effect on offshore installation times during cable routing in the foundation and TP.
• Depending on the grid layout chosen by the wind park designer, different
setups in the connection of the in- and outgoing subsea cables to the
switchgear may apply.
• With the connection systems ACTB, ACTR, ACTF, ACTT and ACTS
NKT offers a portfolio of product solutions to cover all this demands.
Typical installation arrangements in 72kV offshore wind parks (single line diagrams):
2 2
• A wide range of termination systems is available in 36 / 72 and 145kV. Project specific adaptions can also be found in the market.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 19
Product portfolio for offshore applications
Static vs. dynamic subsea cables: Solutions for floating platforms from a power cable accessories perspective
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 20
Termination systems for offshore wind farms
Typical installation arrangements in 72kV offshore wind parks (single line diagrams):
Tower cable
T-connector incoming array
1 cable (CB72-1250)
Subsea cable
T-connector outgoing array
2 cable (CB72-1250)
5 6
1 2
.
ACTB
.
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 22
Offshore Cable
Accessories
ACTB – Array Cable Termination Box
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 23
ACTB’s│Defined interconnection point for subsea & tower cables
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 24
Termination systems for offshore wind farms
The NKT ACTB is placed The ACTB is available in These double-sided bushings
on a platform inside the different sizes and versions, mounted into a back-to-back
foundation or TP all made of corrosion arrangement of cabinets
free glass fibre reinforced enables a clear separation
polyester resin and equipped between incoming (Submarine
with double-sided bushings.(1) Cable) and tower internal
(Medium Voltage) cables.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 25
Termination systems for offshore wind farms
Cable Arrangement I (36 or 72kV) Cable Arrangement II (36kV (1)) Cable Arrangement III (36kV (1))
1) For 72kV cable arrangement II & III is possible with deeper cabinets (on request)
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 26
Termination systems for offshore wind farms
• Adapt the ACTB to your project – just let us • Tower cable from same deck • Tower cable from a lower deck
know your cable routing…
A A
B B
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 27
Termination systems for offshore wind farms
ACTB│ Foundations - Fits for all types of OWT sub-structures / grounded and floating
The NKT ACTB is placed on a The support structures for large offshore wind farm developments fall into two main categories; floating
platform inside the foundation and grounded. Both types can be further differentiated by their layout, method of installation and
construction materials. The ACTB could be used within all the different support structures.
During cable laying After cable laying After installation After installation
As long as the wind turbine After installation of the Submarine After the installation of the Also a direct coupling of the two
erection is not completed, the Cables the line can be energized tower, the GIS (gas-insulated- or three incoming subsea cables
Submarine Cable will be immediately and all the already switchgear) could be in one ACTB (36kV) is possible
terminated on the incoming installed wind turbines can be connected to the submarine and reducing the space
(primary) side of the cabinet utilized. Almost all the following cable. requirements in the foundation.
arrangement, whereas on the construction and installation work
tower internal (secondary) can be carried out without de-
side the bushings are covered energizing the submarine cable,
with voltage proof covering i.e. without any de-utilization of the
caps. productive wind turbines.
Jumper cable
1) Dimension sheets standard sizes see appendix (B)
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 29
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
Cabinet
Stand
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 30
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 31
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
A A
B B
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 32
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
Lifting points
Cabinet door
Cabinet side walls
Removable threshold
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 33
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
Warning label
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 34
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
T-connector CB 72
Split earth-bar
with bridge cable
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 35
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 36
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 37
Termination systems for offshore wind farms
ACTB│ GA Drawing KT484D-66 series – Cabinet and stand (including optional components)
ground fixing
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 38
Termination systems for offshore wind farms
• Allows separation of screening cables from the incoming • Allows separation of MV cables and F.O. cables within individual
Submarine cable and earthing leads of the bushing and compartments of the cabinet.
connectors for cable testing. • Individual locking systems could be used. Double locking
• Location in the side wall of the cabinet allows easy fixing of the systems are available. (Two different keys could open one door )
earthing cables.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 39
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 40
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 41
Termination systems for offshore wind farms
GRP
stainless
steel
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 42
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 43
Termination systems for offshore wind farms
1) “equivalent to IP68”
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 44
Termination systems for offshore wind farms
ACTB│ Packaging
• Cabinet and required accessories as well as spare parts are packed together and marked with wind turbine number facilitates logistic
onshore and on the way to the platforms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 45
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 46
Termination systems for offshore wind farms
ACTB│ Cabinet arrangements for one incoming subsea cable (Al/Cu) and one tower cable (Al/Cu)
Connection point (distribution inside a connection housing) for electrical connection of medium/high voltage
cables with further medium/high voltage cables, equipment, internal cables or lines.
c
Non-walkable housing with doors at front and rear side made from isolating material (GRP), including built-in
double bushings type C2 acc. to EN 50180 / EN 50181 or F acc. to EN 50673 to connect single core medium
4 or high voltage cable or lines by means of screened bolted cable connectors.
Housing to be mounted on a metal stand including mechanical bracing for cables.
The transition cabinet must only be operated in an area (closed electrical operating site) which is solely
1 accessible for authorized personal (accessibility class A).
It must be assured that doors to the closed operating site cannot be opened by unauthorized persons.
Any installation work must be conducted by trained power current installers.
2 3 The connections and housing are not classified as switching device or switchgear, and consequently standards
2 EN 62271-200, 201, and 202 do not apply.
Switching operations and test of zero-potential are not possible.
Earthing and short-circuiting of individual cable connections is only possible when opened and after external
x
disconnection (isolation) and securing and installation work with cable connectors
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 47
Termination systems for offshore wind farms
.
ACTB
.
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 48
A4O
ACTS
(Array Cable Termination System)
1 The predefined interconnection point for Submarine Cables, allows for testing and hand over of
the Submarine Cables after installation and before the turbine erection.
2 Energizing the wind farm even when not all wind turbines are installed.
3 „Easy earthing“ of parts of the wind park cables e.g. infield cable screens.
7 Space for fiber optic cables can be made available in the same setup, but in a separate compartment.
10 Several compartment arrangements available – back-to-back or side-by-side, depending on space conditions on the foundation.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 50
Accessories for Offshore Applications – 72kV
ACTS│ ACTS72-xx series – versions
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 52
Termination systems for offshore wind farms
U-bushing Type F
Fixing brackets
Earthing bars
Base plate
Cable sealing
Fixing points (ø13)
Several outlets e.g. for main earth
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 53
Termination systems for offshore wind farms
Fixing brackets
Base plate
Cable sealing
Complete (single w/o front cover w/o short circuit w/o T-connectors
phase) cover w/o upper T-connector
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 54
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 55
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 56
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 57
Termination systems for offshore wind farms
Material
Glasfaser GRP
Gießharz Cast resin
E-Cu Copper
A4_Edelst Stainless steel 1.4404 marine grade
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 58
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 59
Product portfolio for offshore applications
Type - ACTS-72-1800
Not in the Standard IEC
Rated short-time withstand current; 0.5 sec kA
60840
Insulation material (bushing) Epoxy resin
interface type F
Connection to outside cone bushing acc. to EN 50673
1250 A*
Permanent maximum current rating Im A
*Limited by bushing
and/or cable
Capacitive measuring point pF n.a.
Max. working voltage Um kV 72.5 kV Volt
.
ACTB
.
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 61
A4O
ACTT
(Array Cable Termination Tower)
.
ACTB
.
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 66
A4O
ACTR-D
(Array Cable Termination Rack Diagonal)
.
ACTB
.
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 70
A4O
ACTR
(Array Cable Transition Racks)
ACTR’s
w/o coupling piece
36 & 72kV
ACTR’s
with coupling
piece
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 72
Termination systems
ACTR’s
w/o coupling piece
36 & 72kV
ACTR’s
with coupling
piece
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 73
ACTR - CB-CC
CB-CC combination
• Customized solutions, like the 72kV CC-CB-CC combination, could be offered and adapted to your projects
enabling an optimized solution in regards to your technical data and space limitations.
• As long as the TP with the switchgear has not been installed, the CB72-
CC72 connection could be used to bridge the two incoming subsea
cables.
• This enables the connection of finalized turbines to the OSS even if not
all turbines in a string are available.
• The tower cable can be a smaller cross section as it only has to carry
the load of one turbine
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 74
ACTR - CB-CC
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 75
ACTR - CB-CC
CB-CC combination
after turbine
installation
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 76
ACTR - CB-CC
CB-CC combination
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 77
ACTR - CB-CC
CB-CC combination
• The pivot point between the two (three) connectors allows a very flexible arrangement of the cables and
a perfect adaption to existing metal structures or cable trays.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 78
Termination systems
ACTR’s
w/o coupling piece
36 & 72kV
ACTR’s
with coupling
piece
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 79
Termination systems for offshore wind farms
.
ACTB
ACTP
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 80
ACT?? - CB-CP-CB
CP72 M16
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 81
Termination systems for offshore wind farms
.
ACTB
ACTP
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 82
ACTR - CB-CP-CB
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 83
ACTR - CB-CP-CB
CP72 M16
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 85
ACTR - CB-CP-CB
ACTR 72 F M16
• The combination of two T-connectors with a double bushing (as used in the ACTB’s) fixed on a mounting plate allows a
perfect integration of the termination point for the incoming and outgoing array cable into the existing metal structure of
either the foundation, TP or OSS.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 86
ACTR - CB-CP-CB
ACTR 72 F M16
• The combination of two T-connectors with a double bushing (as used in the ACTB’s) fixed on a mounting plate allows a
perfect integration of the termination point for the incoming and outgoing array cable into the existing metal structure of
either the foundation, TP or OSS.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 87
ACTR - CB-CP-CB
ACTR 72 F M16
ACTR 72 F M16
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 89
ACTR - CB-CP-CB
ACTR 72 F M16
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 90
ACTR - CB-CP-CB
• 6x T-connector
(one for front- the other for rear connector)
• 2x Optional connection to main earth
• 6x Cable screen
ACTR 72 F M16
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 92
ACTR - CB-CP-CB
standard 1m
max. 1,2m
min. 0,6m
min. 0.7m
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 93
Termination systems for offshore wind farms
.
ACTB
ACTP
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 94
ACTR72-I
• F-cone U-bushing
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 95
ACTR72-I
ACTR 72-I
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 96
Termination systems for offshore wind farms
.
ACTB
.
ACTR
ACTD
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 97
ACTR - CB-CP-CB
ACTR 72 F M16-Diagonal
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 98
Termination systems for offshore wind farms
• Electrical system: type tested in accordance to CENELEC HD 629.1 (36kV) and IEC60840
(72kV)
• amongst others: Electrical heat cycle test in water for 21 days and 63 load cycles
• Immersion depth 1 m (1)
1) “equivalent to IP68”
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 99
Product portfolio for offshore applications
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 100
Product portfolio for offshore applications
72kV – Termination Systems
T-Connector Coupling-
(outer cone) Connector
(outer
cone)
Termination Surge
systems arrester
(outer
cone)
Pre-
terminated Connector
cables (inner
cone)
Joints
1 Assembly
tools
5
NKT_Acc_Coc_WPCA_v12.03_ACTx_short| 101
Termination systems for offshore wind farms
.
ACTB
.
ACTR
ACTR-D
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 102
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 103
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 104
Termination systems for offshore wind farms
Bushings are
Side wall one in Fixing bracket for
terminated onto the T-
position dropper cable adjusted
connectors
to the T-connector
positions
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 106
Termination systems for offshore wind farms
Terminating of the
Top cover Side walls
dropper cables
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 107
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 108
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 109
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 110
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 111
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 112
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 113
Product portfolio for offshore applications
Connector body Stress cone element Insulating plug Screw type cable lug Contact pin Covering cap
CB 72-1250
for class1, 2
and class 5
conductors
1
0
0
0
N
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 116
Product portfolio for offshore applications
U0/U (Um) 76/132…138(145) kV
T-Connector Coupling-
(outer cone) Connector
(outer
cone)
Termination Surge
systems arrester
(outer
cone)
Pre-
terminated Connector
cables (inner
cone)
Joints
1 Assembly
tools
5
NKT_Acc_Coc_WPCA_v12.03_ACTx_short| 117
Accessories for Offshore Applications – 145kV
Launch of the worldwide first 145kV outer cone system at the Wind fair Hamburg 27-30.09.2022
T-Connector Coupling-
Products
(outer cone) Connector
T-Connectors Phase 1: up to 630² (outer cone)
Coupling-Connectors
Dead-end plugs (Ø isolation 64-75mm)
Bushings
Inner Cone Connectors Termination
Joints
systems Surge
Surge arresters
Termination Systems
Phase 2: larger cross arrester
Pre-terminated cables sections up from 2025 (outer cone)
Assembly tools
Joints
As T-connector Assembly
tools
T-Connector Coupling-
(outer cone) Connector
(outer
cone)
Termination Surge
systems arrester
(outer
cone)
Pre-
terminated Connector
cables (inner
cone)
Joints
1 Assembly
tools
NKT_Acc_Coc_WPCA_v12.03_ACTx_short| 120
Product portfolio for offshore applications
Main focus phase 1: Turbine 145kV
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 121
Termination systems for offshore wind farms
.
ACTB
.
ACTR
ACTS .
ACTS
.
ACTF
ACTT
The challenge – what is the most efficient setup for YOUR project?
I II III IV V VI VII
2 2 2 2 2 2 2
?
Offshore cable accessories v5.01 | 02.05.2017 | 123
Accessories for Offshore Applications – 145kV
ACTS│ ACTS145-xx series – versions
1 The predefined interconnection point for Submarine Cables, allows for testing and hand over of
the Submarine Cables after installation and before the turbine erection.
2 Energizing the wind farm even when not all wind turbines are installed.
3 „Easy earthing“ of parts of the wind park cables e.g. infield cable screens.
7 Space for fiber optic cables can be made available in the same setup, but in a separate compartment.
10 Several compartment arrangements available – back-to-back or side-by-side, depending on space conditions on the foundation.
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 125
Termination systems for offshore wind farms
U-bushing Type F
Fixing brackets
Earthing bars
Base plate
Cable sealing
Fixing points (ø13)
Several outlets e.g. for main earth
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 126
Termination systems for offshore wind farms
U-bushing
Base plate
Cable sealing
Fixing brackets
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 127
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 128
Termination systems for offshore wind farms
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 129
Termination systems for offshore wind farms
.
ACTB
ACTP
ACTR
ACTD
ACTF
ACTT
NKT_Acc_Coc_WPCA_v12.03_ACTx_short | 130
ACTR145-I
• F-cone U-bushing
NKT_Acc_Coc_WPCA_v12.03_ACTx_short| 131
ACTR72-I
ACTR 72-I
NKT_Acc_Coc_WPCA_v12.03_ACTx_short| 132
Contact
Björn Spiers
T: +49 4731 364 280
bjoern.spiers@nkt.com
www.nkt.com