You are on page 1of 248

``

PLF STRUCTURAL ENGINEERS, INC.


CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314.
0: (954) 533-237 fax: (954) 533-2117
Email: pfiallo@plfengineers.com
Structural Calculation Report

BURNT STORE LAKES DESIGN REPORT

17293 CAPE HORN BLVD PUNTA GORDA, FL, 33955

Pundat Gorda, FL33955

Page 01of 248


CONTENTS

Title Page
Ch

A Design Philosophy & Bibliography 003

B Materiality 008

C Loads & Etabs analysis Report 010

D Foundation design 027

E Grade slab design 084

F Precast beam design 086

G Precast Lintel design 115

H Precast wall design 160

H.1 Lattice Girder Design 209

H.2 Concrete Rupture check 212

J Precast connection design 215

J.1 Foundation to Wall conection Design 216

J.2 Beam to Wall connection design 237

K concrete plain Bearing check 242

L Lifting & handling check 244


`

Page 02of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : BIBILOGRAPHY
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter A

Design Philosophy &


Bibliography

Page 03of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : DESIGN PHILOSOPHY
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Design Philosophy

Page 04of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : DESIGN PHILOSOPHY
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

This report summarizes the design philosophy, primary assumptions, methods of analysis / design,
performance criteria adopted for the structural engineering design of the BURNT STORE LAKES PROJECT,
(BUILT AREA 4112.3 Sq-ft for Each unit), FLORIDA CITY

The aim is to formulate a structural system which can adequately resist loads due to gravity, wind
with maximum efficiency. The primary structural members consists of 6" & 4" Precast walls
to resist the vertical and lateral loads. LGS Roof Truss system provided to act as diaphragm in order to
transfer the lateral load within the horizontal plane to the shear walls.

The report lists down all the design standards, codes, technical literature and materials that have been
adopted for the preliminary design and is the basis for subsequent detailed design.

For structural analysis of the structure under gravity & wind, a three dimensional elastic structural
finite element model has been made using ETABS software. The shear walls are also
designed using Eriksson software. Foundation is designed using SAFE software.

Page 05of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : BIBILOGRAPHY
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

A- Bibliography

ACI 318-14 : Building Code Requirements for Structural Concrete (ACI 318-19)
and Commentary , Farmington Hills, MI, September 2011.

ASCE 7- 16 : Minimum design loads for buildings and other structures.


p. cm.“ASCE Standard ASCE/SEI 7-16.”
Published by American Society of Civil Engineers.

IBC 2018 : 2018 International Building Code, Publications, 4051 West Flossmoor Road,
Country Club Hills, IL 60478 .

ACI 301-10 : Specification for Structural Concrete , ACI Committee 301 , Publication Year: 2010
ISBN: 9780870314032.

ACI 315-20 : SP-66(04) ACI Detailing Manual-2020; Details and Detailing of


Concrete Reinforcement , Publication Year 2020

FBC-2020 : 2020 Florida Building Code (fbc), 7th Edition.

AWS 360-16 : American Welding Association “Code for Welding in Building Construction”, Latest edition.

Page 06of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : BIBILOGRAPHY
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

A-2 Publications

A-2 Publications

PCA-NOTES : Notes on ACI 318-08 BUILDING CODE REQUIREMENTS FOR


STRUCTURAL CONCRETE with Design Applications

PCI MNL : PCI Design Handbook - Precast and Prestressed Concrete, 7th Edition,
Precast/Prestressed Concrete Institute, Chicago, IL, 2010 , ISBN 9780937040874

PCI MNL-128 : PCI-Manual of Hollowcore design - second edition , Prepared for the
PCI Hollow Core Slab Producers Committee , 1998 , ISBN 0937040576

PCI JOURNAL : PCI Committee on Precast Sandwich Wall Panels, State-of-the-Art of Precast/
Prestressed Sandwich Wall Panels, PCI Journal, vol. 42,no. 2, march-april 1997.

Guide to the Wind Load:


Guide to the wind load provisions of ASCE 7-10
Kishor C. Mehta, Ph.D., P.E., William L. Coulbourne, P.E.

Guide to the Seismic Load :


Guide to the seismic load provisions of ASCE 7-5
Finley A. Charney, Ph.D., P.E.

Seismic Illustrated Guide :


Guide to the Seismic Load seismic load provisions of ASCE 7-10
S. K. Ghosh, Ph.D.; Susan Dowty, P.E.; and Prabuddha Dasgupta, Ph.D., P.E.

Page 07of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : MATERIALITY
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter B

Materiality

Page 08of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : MATERIALITY
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

B- Materiality

B-1 Concrete

Item Cylinder 28days concrete strength (PSI)


CIP Grade slab 5000
Precast foundation 6000
Precast Beams 6000
Precast Solid Walls 6000
CIP screed 5000

Ec (Elasticity Modulus of Concrete) = wc1.5 33 √( f 'c ) ACI 318-14, Section 19.2.2.1.a

gc (Volume RC-concrete weight) = 150 pcf

ac (Expansion thermal coefficient ) = 6E-06 m /m/Co

B-2 Concrete Reinforcement

Deformed Steel Bars as Concrete Reinforcement

Fy ( yield stress of uncoated steel complying with ASTM A615 Designated "T") = 60000 psi
ASTM A615 / A615M

Fvy (Maximum usable steel stress for shear reinforcement ) = 60000 psi

Es (Modulus of elasticity of Steel) = 3E+07 psi


20.2.2.2 ACI-318-14

Welded Wire Fabric

Fy ( yield stress of welded wire fabric complying with ASTM A1064) = 70 ksi
ASTM A11064
B.3 Structural Steel

Steel Shapes and Plates (in Case it used for precast Connection)

Fy (minimum yield stress based on A36 grade 36) = 36 ksi


(ASTM A 36 Grade 36)
B.4 Holes Grouting :
None Shrinkage Concrete Grouting with min. Fcu = 6000 psi
(refer to material submittal )

Page 09of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : LOAD DETAIL
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter C

Loads

Page 10of 248


PLF STRUCTURAL ENGINEERS, INC.
CA #30758 PROJECT: BURNT STORE LAKES
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : LOAD DETAIL
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

ETABS Load Input Calculations:

C.1 Floor Finishes (Ceramic Floor Tile) = 23 psf


C.2 Partitions Load (27 mill metal studs with 1/2" gypsum biard on each side) = 15 psf
C.3 Live Load = = 40 psf
C.4 Truss Roof Live Load = = 30 psf
C.5 Truss Roof Dead Load (Top Chord) = = 20 psf
C.6 Truss Roof Dead Load (Bottom Chord) = = 10 psf

C.7 Pod Load sample calculation


At Level-2

At Grade Level Pod Area:

Pod Design Type = RB-01


Total Weight of pod = 9143 lbs (Refer POD loading Detail report)
(As per approved pod drawing)
Total Load from Pod = (9143/ 44.3989)
= 205.929 Psf
Actual slab area = 0 ft²
Pod slab area = 44.4 ft²

Total Pod Load = 0.206 Ksf

Partition Wall Load (Dry wall):


Dry wall load (27 mill metal studs with 14 psf x 9.5 ft /1000 = 0.13 Kip/ft
1/2" gypsum board on each side)

Page 11of 248


PLF STRUCTURAL ENGINEERS, INC.
CA #30758 PROJECT: BURNT STORE LAKES
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : LOAD DETAIL
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Page 12of 248


PLF STRUCTURAL ENGINEERS, INC.
CA #30758 PROJECT: BURNT STORE LAKES
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : LOAD DETAIL
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

As per IBC-2018 -1613.1 excepotions 1

Seismic Design Category A

Detached one and two family dwelings

Ss <0.4g

Sesmic design need not to be considered .

Page 13of 248


PLF STRUCTURAL ENGINEERS, INC.
CA #30758 PROJECT: BURNT STORE LAKES
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : LOAD DETAIL
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Truss Live load applied on Etabs at Roof Level

Page 14of 248


PLF STRUCTURAL ENGINEERS, INC.
CA #30758 PROJECT: BURNT STORE LAKES
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : LOAD DETAIL
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Truss Dead load applied on Etabs at Roof Level

Page 15of 248


PLF STRUCTURAL ENGINEERS, INC.
CA #30758 PROJECT: BURNT STORE LAKES
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : LOAD COMBINATION
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Ultimate Load Combinations: (ASCE 7-16 Section:2.3.1)

1) 1.4 DL
2) 1.2 DL + 1.6 LL + 0.5 Lr
3) 1.2 DL + 1.6 LL+ 0.5 Lr
4) 1.2 DL + 0.5 LL + 1.6 Lr
5) 1.2 DL + 1.0 Wx + 1.0 LL + 0.5 Lr
6) 1.2 DL + 1.0 Wy + 1.0 LL + 0.5 Lr
7) 0.9 DL+1.0 Wx
8) 0.9 DL+1.0 Wy

Service Load Combinations: (ASCE 7-16 Section:2.3.1)

1) 1.0 DL
2) 1.0 DL + 1.0 LL
3) 1.0 DL + 1.0 Lr
4) 1.0 DL + 0.75 LL + 0.75 Lr
5) 1.0 DL + 0.6Wx
6) 1.0 DL + 0.6Wy
7) 1.0 DL + 0.45 Wx + 0.75 LL + 0.75 Lr
8) 1.0 DL + 0.45 Wy + 0.75 LL + 0.75 Lr
9) 0.6 DL+0.6 Wx
10) 0.6 DL+0.6 Wy

DL - Dead loads
LL - Live load
LLr - Roof truss live load/Other roof load
Wx - Wind load at X direction
Wy - Wind load at Y direction

Page 16of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

CS2018 Ver 2021.08.14

STRUCTURAL CALCULATIONS
FOR

BURNT STORE LAKES

FLORIDA CITY, FL

To the best of my knowledge and professional judgement all calculations contained herein
have been reviewed, and conform to the recommendation of ASCE/SEI 7-16, ACI 318-
14, AISC 360-16, and the 2020 Florida Building Code, 7th Edition

Page 17of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

www.struware.com

Code Search
Code: Florida Building Code 2020

Occupancy:
Occupancy Group = R Residential

Risk Category & Importance Factors:


Risk Category = II
Wind factor = 1.00
Snow factor = 1.00
Seismic factor = 1.00

Type of Construction:
Fire Rating:
Roof = 0.0 hr
Floor = 0.0 hr

Building Geometry:
Roof angle (θ) 5.00 / 12 22.6 deg
Building length 69.7 ft
Least width 13.3 ft
Mean Roof Ht (h) 16.5 ft
Parapet ht above grd 0.0 ft
Minimum parapet ht 0.0 ft

Live Loads:
Roof 0 to 200 sf: 19 psf use 30.0 psf
200 to 600 sf: 30 psf
over 600 sf: 30 psf

Floor:
Typical Floor 40 psf
Partitions 15 psf
Lobbies & first floor corridors 100 psf
Corridors above first floor 80 psf
Balconies (1.5 times live load) 60 psf

Page 18of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

Wind Loads : ASCE 7 - 16


Ultimate Wind Speed 160 mph
Nominal Wind Speed 123.9 mph
Risk Category II
Exposure Category D
Enclosure Classif. Enclosed Building
Internal pressure +/-0.18
Directionality (Kd) 0.85
Kh case 1 1.047
Kh case 2 1.047
Type of roof Gable

Topographic Factor (Kzt)


Topography Flat
Hill Height (H) 80.0 ft
Half Hill Length (Lh) 100.0 ft
Actual H/Lh = 0.80
Use H/Lh = 0.50
Modified Lh = 160.0 ft
From top of crest: x = 50.0 ft
Bldg up/down wind? downwind

H/Lh= 0.50 K1 = 0.000


x/Lh = 0.31 K2 = 0.792
z/Lh = 0.10 K3 = 1.000
At Mean Roof Ht:
Kzt = (1+K1K2K3)^2 = 1.00

Gust Effect Factor Flexible structure if natural frequency < 1 Hz (T > 1 second).
h= 16.5 ft If building h/B>4 then may be flexible and should be investigated.
B= 13.3 ft h/B = 1.24
/z (0.6h) = 9.9 ft

G= 0.85 Using rigid structure default


Rigid Structure Flexible or Dynamically Sensitive Structure
ē= 0.13 Natural Frequency
34 (η1) = 0.0 Hz
ℓ = 650 ft Damping ratio (β) = 0
zmin = 7 ft /b = 0.80
c= 0.13 /α = 0.11
gQ, gv = 3.4 Vz = 164.2
Lz = 559.2 ft N1 = 0.00
Q= 0.95 Rn = 0.000
Iz = 0.15 Rh = 28.282 η= 0.000 h= 16.5 ft
G= 0.90 use G = 0.85 RB = 28.282 η= 0.000
RL = 28.282 η= 0.000
gR = 0.000
R = 0.000
Gf = 0.000

Page 19of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

Enclosure Classification
Test for Enclosed Building: Ao < 0.01Ag or 4 sf, whichever is smaller

Test for Open Building: All walls are at least 80% open.
Ao ≥ 0.8Ag

Test for Partially Enclosed Building: Predominately open on one side only

Input Test
Ao 500.0 sf Ao ≥ 1.1Aoi NO
Ag 600.0 sf Ao > 4' or 0.01Ag YES
Aoi 1000.0 sf Aoi / Agi ≤ 0.20 YES Building is NOT
Agi 10000.0 sf Partially Enclosed

Conditions to qualify as Partially Enclosed Building. Must satisfy all of the following:
Ao ≥ 1.1Aoi
Ao > smaller of 4' or 0.01 Ag
Aoi / Agi ≤ 0.20
Where:
Ao = the total area of openings in a wall that receives positive external pressure.
Ag = the gross area of that wall in which Ao is identified.
Aoi = the sum of the areas of openings in the building envelope (walls and roof) not including Ao.
Agi = the sum of the gross surface areas of the building envelope (walls and roof) not including Ag.

Test for Partially Open Building: A building that does not qualify as open, enclosed or partially enclosed.
(This type building will have same wind pressures as an enclosed building.

Reduction Factor for large volume partially enclosed buildings (Ri) :


If the partially enclosed building contains a single room that is unpartitioned , the internal
pressure coefficient may be multiplied by the reduction factor Ri.

Total area of all wall & roof openings (Aog): 0 sf


Unpartitioned internal volume (Vi) : 0 cf
Ri = 1.00

Ground Elevation Factor (Ke)


Grd level above sea level = 0.0 ft Ke = 1.0000
Constant = 0.00256 Adj Constant = 0.00256

Page 20of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

Wind Loads - MWFRS all h (Except for Open Buildings)


Kh (case 2) = 1.05 h= 16.5 ft GCpi = +/-0.18
Base pressure (qh) = 58.3 psf ridge ht = 17.9 ft G= 0.85
Roof Angle (θ) = 22.6 deg Bldg length = 69.7 ft qi = qh
Roof tributary area - (h/2)*L: 575 sf width = 13.3 ft
(h/2)*w: 110 sf
Ultimate Wind Surface Pressures (psf)
Wind Normal to Ridge Wind Parallel to Ridge
B/L = 0.19 h/L = 1.24 L/B = 5.24 h/L = 0.24
Surface Cp qhGCp w/+qiGCpi w/-qhGCpi Dist.* Cp qhGCp w/ +qiGCpi w/ -qhGCpi
Windward Wall (WW) 0.80 39.7 see table below 0.80 39.7 see table below
Leeward Wall (LW) -0.50 -24.8 -35.3 -14.3 -0.20 -9.9 -20.4 0.6
Side Wall (SW) -0.70 -34.7 -45.2 -24.2 -0.70 -34.7 -45.2 -24.2
Leeward Roof (LR) -0.60 -29.8 -40.3 -19.3 Included in windward roof
Neg Windward Roof pressure -0.60 -29.5 -40.0 -19.0 0 to h/2* -0.90 -44.6 -55.1 -34.1
Pos/min Windward Roof press. -0.09 -4.2 -14.8 6.3 h/2 to h* -0.90 -44.6 -55.1 -34.1
h to 2h* -0.50 -24.8 -35.3 -14.3
> 2h* -0.30 -14.9 -25.4 -4.4
Min press. -0.18 -8.9 -19.4 1.6
*Horizontal distance from windward edge

Windward Wall Pressures at "z" (psf) Combined WW + LW


Windward Wall Normal Parallel
z Kz Kzt qzGCp w/+qiGCpi w/-qhGCpi to Ridge to Ridge
0 to 15' 1.03 1.00 39.0 28.5 49.5 63.8 48.9
h= 16.5 ft 1.05 1.00 39.7 29.2 50.2 64.5 49.6
ridge = 17.9 ft 1.06 1.00 40.2 29.7 50.7 65.0 50.2

NOTE:
See figure in ASCE7 for the application of full and partial loading
of the above wind pressures. There are 4 different loading cases.

Parapet
z Kz Kzt qp (psf)
0.0 ft 1.03 1.00 0.0

Windward parapet: 0.0 psf (GCpn = +1.5)


Leeward parapet: 0.0 psf (GCpn = -1.0)

Windward roof overhangs ( add to windward roof pressure) : 39.7 psf (upward)

Page 21of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

Wind Loads - MWFRS h≤60' (Low-rise Buildings) except for open buildings
Kz = Kh (case 1) = 1.05 Edge Strip (a) = 3.0 ft
Base pressure (qh) = 0.0 psf h>B - can't use low-rise method End Zone (2a) = 6.0 ft
GCpi = +/-0.18 Zone 2 length = 6.7 ft

Wind Pressure Coefficients


CASE A CASE B
θ = 22.6 deg
Surface GCpf w/-GCpi w/+GCpi GCpf w/-GCpi w/+GCpi
1 0.54 0.72 0.36 -0.45 -0.27 -0.63
2 -0.45 -0.27 -0.63 -0.69 -0.51 -0.87
3 -0.47 -0.29 -0.65 -0.37 -0.19 -0.55
4 -0.41 -0.23 -0.59 -0.45 -0.27 -0.63
5 0.40 0.58 0.22
6 -0.29 -0.11 -0.47
1E 0.77 0.95 0.59 -0.48 -0.30 -0.66
2E -0.72 -0.54 -0.90 -1.07 -0.89 -1.25
3E -0.65 -0.47 -0.83 -0.53 -0.35 -0.71
4E -0.60 -0.42 -0.78 -0.48 -0.30 -0.66
5E 0.61 0.79 0.43
6E -0.43 -0.25 -0.61

Ultimate Wind Surface Pressures (psf)


1 0.0 0.0 0.0 0.0
2 0.0 0.0 0.0 0.0
3 0.0 0.0 0.0 0.0
4 0.0 0.0 0.0 0.0
5 0.0 0.0
6 0.0 0.0
1E 0.0 0.0 0.0 0.0
2E 0.0 0.0 0.0 0.0
3E 0.0 0.0 0.0 0.0
4E 0.0 0.0 0.0 0.0
5E 0.0 0.0
6E 0.0 0.0
Parapet
Windward parapet = 0.0 psf (GCpn = +1.5) Windward roof
Leeward parapet = 0.0 psf (GCpn = -1.0) overhangs = 0.0 psf (upward) add to
windward roof pressure
Horizontal MWFRS Simple Diaphragm Pressures (psf)
Transverse direction (normal to L)
Interior Zone: Wall 0.0 psf
Roof 0.0 psf
End Zone: Wall 0.0 psf
Roof 0.0 psf

Longitudinal direction (parallel to L)


Interior Zone: Wall 0.0 psf
End Zone: Wall 0.0 psf

The code requires the MWFRS be designed for a min ultimate


force of 16 psf multiplied by the wall area plus an 8 psf force
applied to the vertical projection of the roof.

Page 22of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

Wind Loads - h≤60' Longitudinal Direction MWFRS On Open or Partially


Enclosed Buildings with Transverse Frames and Pitched Roofs
Base pressure (qh) = 0.0 psf h>B - can't use low-rise method ASCE 7-16 procedure
GCpi = +/-0.18 Enclosed bldg, procdure doesn't apply
Roof Angle (θ) = 22.6 deg

B= 13.3 ft
# of frames (n) = 5
Solid are of end wall including fascia (As) = 1,500.0 sf
Roof ridge height = 17.9 ft
Roof eave height = 15.1 ft
Total end wall area if soild (Ae) = 219.5 sf

Longidinal Directional Force (F) = pAe


p= qh [(GCpf)windward -(GCpf)leeward] KB KS
Solidarity ratio (Φ) = 6.835
n= 5
KB = 1.667
KS = 40.508
Zones 5 & 6 area = 172 sf
5E & 6E area = 47 sf
(GCpf) windward - (GCpf) leeward] = 0.766
p= 0.0 psf

Total force to be resisted by MWFRS (F) = 0.0 kips applied at the centroid
of the end wall area Ae

Note: The longidudinal force acts in combination with roof loads


calculated elsewhere for an open or partially enclosed building.

Page 23of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

NOTE: Torsional loads are 25% of zones 1 - 6. See code for loading diagram.
Exception: One story buildings h<30' and 1 to 2 storybuildings framed with light-frame
construction or with flexible diaphragms need not be designed for the torsional load case.

ASCE 7-98 & ASCE 7-10 (& later) - MWFRS wind pressure zones

NOTE: Torsional loads are 25% of zones 1 - 4. See code for loading diagram.
Exception: One story buildings h<30' and 1 to 2 storybuildings framed with light-frame
construction or with flexible diaphragms need not be designed for the torsional load case.

ASCE 7-02 and ASCE 7-05 - MWFRS wind pressure zones

Page 24of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

Ultimate Wind Pressures


Wind Loads - Components & Cladding : h ≤ 60'
Kh (case 2) = 1.05 h= 16.5 ft
Base pressure (qh) = 58.3 psf a= 3.0 ft
Minimum parapet ht = 0.0 ft GCpi = +/-0.18
Roof Angle (θ) = 22.6 deg qi = qh = 58.3 psf
Type of roof = Gable

Roof Surface Pressure (psf) User input


Area 2 sf 4 sf 10 sf 20 sf 50 sf 100 sf 150 sf 300 sf 350 sf 75 sf 250 sf
Negative Zone 1 & 2e -98 -98 -98 -98 -84.2 -73.8 -67.6 -57.2 -57.2 -78.1 -59.9
Negative Zone 2n, 2r &3e -156.4 -156.4 -156.4 -137 -111.3 -91.9 -80.5 -80.5 -80.5 -99.9 -80.5
Negative Zone 3r -220.6 -220.6 -182.5 -153.6 -115.5 -115.5 -115.5 -115.5 -115.5 -115.5 -115.5
Positive All Zones 51.3 47.2 41.7 37.6 32.1 28.0 28.0 28.0 28.0 29.7 28.0
Overhang Zone 1 & 2e -116.7 -116.7 -116.7 -116.7 -112.7 -109.8 -108.0 -105.0 -105.0 -111.0 -105.8
Overhang Zone 2n & 2r -175 -175 -175 -163.1 -147.3 -135.4 -128.4 -128.4 -128.4 -140.3 -128.4
Overhang Zone 3e -210.1 -210.1 -210.1 -181.7 -144.2 -115.8 -99.2 -99.2 -99.2 -127.6 -99.2
Overhang Zone 3r -274.2 -274.2 -223.4 -185 -134.2 -134.2 -134.2 -134.2 -134.2 -134.2 -134.2

Overhang pressures in the table above assume an internal pressure coefficient (Gcpi) of 0.0
Overhang soffit pressure equals adj wall pressure (which includes internal pressure of 10.5 psf)

Parapet
qp = 0.0 psf Surface Pressure (psf) User input
Solid Parapet Pressure 4 sf 10 sf 20 sf 50 sf 150 sf 300 sf 500 sf 45 sf
CASE A: Zone 2e : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Zone 2n, 2r & 3e : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Zone 3r : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

CASE B : Interior zone : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Corner zone : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Walls GCp +/- GCpi Surface Pressure at h User input


Area 10 sf 100 sf 200 sf 500 sf 10 sf 100 sf 200 sf 500 sf 12 sf 12 sf
Negative Zone 4 -1.28 -1.10 -1.05 -0.98 -74.7 -64.4 -61.3 -57.2 -73.9 -73.9
Negative Zone 5 -1.58 -1.23 -1.12 -0.98 -92.2 -71.6 -65.4 -57.2 -90.6 -90.6
Positive Zone 4 & 5 1.18 1.00 0.95 0.88 68.9 58.5 55.4 51.3 68.0 68.0

Page 25of 248


PLF STRUCTURAL ENGINEERS, INC. JOB TITLE BURNT STORE LAKES
CA#30758
4960 SW 52nd Street, Suite #401 Davie FL. 33314 JOB NO. SHEET NO.
(O) 954-533-3237 (FAX) 954-697-7697 CALCULATED BY DATE 12-4-23
pfiallo@plfengineers.com CHECKED BY DATE

Location of C&C Wind Pressure Zones - ASCE 7-16

Roofs w/ θ ≤ 10° Walls h ≤ 60' Gable, Sawtooth and


and all walls & alt design h<90' Multispan Gable θ ≤ 7 degrees & Monoslope roofs
h > 60' Monoslope ≤ 3 degrees 3° < θ ≤ 10°
h ≤ 60' & alt design h<90' h ≤ 60' & alt design h<90'

Monoslope roofs Multispan Gable & Hip 7° < θ ≤ 27°


10° < θ ≤ 30° Gable 7° < θ ≤ 45°
h ≤ 60' & alt design h<90'

Sawtooth 10° < θ ≤ 45°


h ≤ 60' & alt design h<90'

Stepped roofs θ ≤ 3°
h ≤ 60' & alt design h<90'

Page 26of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter D

CIP Foundation design

Page 27of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Strip foundation design :

Design is based on finite analysis of shell elements.


Foundation data :

Material properties Footing Geometry at all Wall Locations


Clear cover = 1.5 in Footing Slab depth = 7.5 in
Concrete grade f'c = 6000 Psi External Foundation width = 1.5 ft
Rebar grade = 60000 Psi
Soil properties
Allowable bearing capacity= 2500 Psf (Refer Geotechnical soil Report)

PLAN VIEW:
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Notes:
* Property modifiers assigned to elements in ETABS will not be exported into SAFE
* Rigid area zones above columns will be automatically assigned to floors in SAFE.
* Uniform load sets defined in ETABS are not exported

Foundation Design Philosophy :

* Models is imported from ETABS into SAFE by specifying exporting option , story to be exported ,
load cases and combinations.

* The options used to Export from ETABS to SAFE is


Floor loads and loads from above: This option is recommended when loads from above have an
important effect on the floor being exported (i.e transferfloor), for foundation design and also this is the
recommended option to export gravity and lateral loads. In this case, loads in SAFE will be separated in
two load patterns floor loads and loads from above (i.e. Dead_Above, Dead); these load patterns will be
combined in one load case (i.e. DEAD)

Representation of Loads Imported from Etabs 3D view :


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Footing Slab properties:


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Soil subgrade properties Considered in Safe Software:


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Soil pressure due to service load combination (1.0 DL + 1.0 LL):

Safe soil bearing Capacity 2.5 ksf (refer soil report)

Soil pressure 1.32 < 2.5 ksf OK


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

7.5" thick Slab Bottom main reinforcement design at X-direction shear walls
* Footing Reinforcement designed for ultimate Envelope combination

Reinforcement requirement in X-Direction of Footing (along width of Footing):

Required reinforcement = (2) - #4

Provided reinforcement = (3) - #4


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

7.5" thick Slab Top main reinforcement design at X-direction shear walls
* Footing Reinforcement designed for ultimate Envelope combination

Reinforcement requirement in X-Direction of Footing (along width of Footing):

Required reinforcement = (2)- #4

Provided reinforcement = 2- #4
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

7.5" thick Slab Bottom reinforcement design at X-direction shear walls


* Footing Reinforcement designed for ultimate Envelope combination

2ft
#3 @
3.5" o.c

Reinforcement requirement in X-Direction of Footing (along width of Footing):

Provided reinforcement at Typical Location in shorter Direction = #3 @ 7" o.c C-bars


Provided area of reinforcement at marked location = 0.19 in^2/ft

Note: Additional reinforcemnt requirements are shown in reinforcement Layout


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

7.5" thick Slab Bottom main reinforcement design at Y-direction shear walls
* Footing Reinforcement designed for ultimate Envelope combination

Reinforcement requirement in Y-Direction of Footing (along width of Footing):

Required reinforcement = (2) - #4

Provided reinforcement = (3) - #4


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

7.5" thick Slab Top main reinforcement design at Y-direction shear walls
* Footing Reinforcement designed for ultimate Envelope combination

Reinforcement requirement in X-Direction of Footing (along width of Footing):

Required reinforcement = (2)- #4

Provided reinforcement = 2- #4
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

7.5" thick Slab Bottom reinforcement design at Y-direction shear walls


* Footing Reinforcement designed for ultimate Envelope combination

#3 @
3.5" o.c

2ft

#3 @
3.5" o.c

Reinforcement requirement in Y-Direction of Footing (along width of Footing):

Provided reinforcement at Typical Location in shorter Direction = #3 @ 7" o.c C-bars


Provided area of reinforcement at marked location = 0.19 in^2/ft

Note: Additional reinforcemnt requirements are shown in reinforcement Layout


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

SHEAR CHECK FOR STRIP FOUNDATION:


Depth of the Foundation, D = 7.5 in
Width of foundation, bw = 18 in
Length of Foundation = 1 ft
Grade of Concrete, f'c = 6000 Psi
Safe bearing capacity of soil = 36000 lb/ft3
Effective Depth of the Foundation, d = 6 in

Design For Shear:


F Shear = 0.75 (ACI:318-14,Table-21.2.1)
F Vn = F Vc
F Vc = F (2√f'cbwd) (ACI:318-14,R9.6.3)
= 0.75 x (2√6000x 18x7.5)/1000 = 12.5 Kip/ft
shear strength shall be checked for 0.5F Vc > Vu (PCI:chapter 5.3)
0.5 F Vc = 6.3 Kip/ft

Design Shear force Vu: (1.2DL+1.6LL) = 5.30 Kip/ft


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : STRIP FOUNDATION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Vu = 4.7 Kip/ft < 12.5 Kip/ft (PCI:chapter 5.3)

0.5 F Vc = 6.3 Kip/ft < 5.3 Kip/ft (Minimum Reinforcement to be provided)

Note: Per PCI Section 5.3, If Vu is Less than 0.5 Phi Vc, no shear Reinforcement is required.

MINIMUM SHEAR REINFORCEMENT CALCULATION Av min:

Design as per ACI318-14 :Table-9.6.34


Bw 18
* Av min,REQ'D = 0.75√f'ç = 0.75*√6000 = 0.02 in²/ft
fy 60000

Bw 18.0
* Av min,REQ'D = 50 = 50 = 0.02 in²/ft
fy 60000

For Av min Use:

Av pro = 0.19 in²/ft > Av req = 0.02 in²/ft


Reinforcement at marked location
1 Legged stirrups #3 7 in o/c OK

Shear friction factor ɸ = 0.75


Shear capacity of provided reinforcement, Vn = 0.75 x 0.188571428571429=x 60 8.49 kips
Required Shear capacity, Vu = 5.30 kips

ɸ Vn > Vu 8.486 > 5.30 Reinforcement is sufficient


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION WALL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
STRUCTURAL CALCULATION REPORT

FOUNDATION WALL DESIGN

1 ) Material properties
Clear cover = 1.5 in
Concrete grade f'c = 3000 Psi
Rebar grade = 60000 Psi

2 ) Foundation wall Geometry


Length of wall L = 1 ft
Height of wall h = 6 ft
Thickness of wall t = 8 in
Eccentricity e = 4 in

3 ) Load Details
P1.Load from Wall Above

Thickness of wall = 0.66 ft Length of wall = 1 ft


Height of wall = 9.5 ft
Load from Wall Above = (0.66 x 9.5 x 1 x 0.15) = 0.94 Kip

P2.Load from Roof Truss:

Dead Load Consideration on = 3.65 Kip/ft


foundation wall

Live Load Consideration on = 0.765 Kip/ft


foundation wall

4 ) Soil Load Detail


Soil Load Height (From Interior )= 6 ft
Soil Load Height (From Extirior )= 1.33 ft
Surcharge = 40 Psf

5 ) Analysis from Eriksson software


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION WALL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
STRUCTURAL CALCULATION REPORT

Dead load Reaction From Etabs ( 1.0 DL - SLS)

Dead Load from Wall Above = ( 1.57 + 2.75 + 2.75 + 2.81 + 2.96 +1.76 ) / 4

= 3.65 Kip
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION WALL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
STRUCTURAL CALCULATION REPORT

Live load Reaction From Etabs ( 1.0 LL + 1.0 Lr)

Live Load from Wall Above = ( 0.36 + 0.61 + 0.59 + 0.58 + 0.59 + 0.34 ) / 4

= 0.7675 Kip
Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Project Information
Project: Burnt store lakes Location: Project Location Date: 13/04/2023
Client: ONX Designer: Job No.:
Description: Foundation panel Spec: ACI 318-14
Material Properties
Concrete
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0
In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight

Rebar Mesh Strand


fy (ksi) 60 - fpu (ksi) -
Es (ksi) 29000 - Ep (ksi) -
Exterior Soil Interior Soil
Pressure Type: Grade Unit Weight (pcf): 120 Pressure Type: Grade Unit Weight (pcf): 120
Lateral Pressure Coef.: 0.5 Lateral Pressure Coef.: 0.5
Load Combinations
Strength Combinations Service Combinations
# D L R W E T H Include # D L R W E T H Include
1 1.4 0 0 0 0 1 1.6 1 1 0 0 0 0 0.75 1
2 1.2 1.6 0.5 0 0 1 1.6 2 1 1 0 0 0 0.75 1
3 1.2 1 1.6 0 0 1 1.6 3 1 0 1 0 0 0.75 1
4 1.2 0 1.6 0.5 0 1 1.6 4 1 0.75 0.75 0 0 0.75 1
5 1.2 1 0.5 1 0 1 1.6 5 1 0 0 0.6 0 0.75 1
6 1.2 1 0.2 0 1 1 1.6
7 0.9 0 0 1 0 1 1.6
8 0.9 0 0 0 1 1 1.6
Settings
Deflection Limits Stress Options Resistance Factors
Add initial bow to reported deflections Failure if cracked Developed Transfering
Tension 0.9 0.75
Additional Bow: 0" Ignore Lateral Strand Eccentricity
Compression 0.65 -
Total Deflection Limit: L / 150
Use Principal Axis Shear 0.75 -
Elastic Analysis
2nd Order Effects: P-Delta
In Place Stress Limits Development Multipliers
Analysis βd : Non-Sway Modulus of Rupture (psi): 7.5 √fc Strand (Normal): 1

R-Value Calculation Compression: 0.6 fc Strand (Debonded): 2


Handling Stress Limits Strand (Cut): 1
Concrete Resistance (k): 13.33
Tension: 7.5 √fc
Insulation Resistance (k): 0.238 Mild: 1
Compression: 0.6 fc Shear Options
Interior Resistance (R): 0.68
Flexure Options Treat as column
Exterior Resistance (R): 0.17 Method: Whitney Stress Block
Cracking Check: None Axial Options
Bottom Length Ignored: 0"
Ignore tensile strength failures
Top Length Ignored: 0"
Ignore buckling failures

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 1


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Concrete Extents
Panel Geometry
Top Elevation : 6'-0" Width : 1'-0" Thickness : 8"
Bottom Elevation : 0"
Height : 6'-0"
Section Type : Solid
Top in Form : Interior
Left Miter Right Miter
Left miter not included in design Right miter not included in design
Openings, Reveals, and Solid Zones
Wall design contains no openings, reveals, or solid zones.

8" 1'-0"

Area, in²: 96.00


Width, in: 12.00
Height, in: 8.00
Cx, in: 6.00
Cy, in: 4.00
6'-0"

6'-0"
Izz, in⁴: 512.00
Iyy, in⁴: 1152.00
Izy, in⁴: 0.00
Sb, in³: 128.00
St, in³: 128.00

0.200L
1'-2⅜"

Side Elevation Front Elevation Section Properties


1'-0"
8"

Cross Section

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 2


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Structural Model
Restraints Releases
Add foundation connection Restrain Moment:
Design contains no releases.

Add floor tie


ID Elevation Type Gravity Rest. Thermal Rest. Stiffness (k/in)
1 0" Restrained -
2 6'-0" Restrained -

6.00 ft

Concentrated Loads Load Options


Load Components (k / kip-ft) Pattern Live Loads for Flexure
ID Elevation Ecc Dead Live Roof Pres. Suct. Seis.
↓ 0.94 0 0 0 0 0
P1 6'-0.0" -3.0"
→ 0 0 0 0 0 0 Selfweight eccentricity: 0"
↓ 3.65 0.77 0 0 0 0
P2 6'-0.0" -3.0" Eccentricity measured from: Panel CG
→ 0 0 0 0 0 0

Wind Loads
Design contains no wind loads
Seismic Loads
Zone Location(s): Full height
Apply multipliers to Deadload + Self weight
Start of Zone (x/L) End of Zone (x/L) Seismic Load (Cs, % of DL)
0.00 1.00 0.0

Temperature Loads Interior Soil Loads Exterior Soil Loads Additional Self Weight
Exterior Temperature (F°): 105 Elevation: 6'-0" Elevation: 3'-5" Start from Bottom: 0"
Interior Temperature (F°): 75 Surcharge (psf): 40 Surcharge (psf): 40 End from Top: 0"
Thermal Elasticity Multiplier: 1 Magnitude (plf): 0
Exterior

H1

P1,P2
H2

Interior
Structural Sections
No structural sections defined, using entire cross section.

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 3


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Reinforcement
Strands
Design contains no prestressing
Rebar
Depth to Loc. from Start from End from Start End
Size Area Diameter Quantity Spacing
CG Left Bottom Top Condition Condition
#3 0.11 0.375" 2 10" 1.5" 1" 1" 1" 90° Hook Anchored
#3 0.11 0.375" 2 10" 6.5" 1" 1" 1" 90° Hook Anchored
Mesh
Design contains no mesh
Interrupts
Design contains no interrupts

1'-0" 1'-0"

1½"
5"
1½"
1" 10" 1" (4) #3
0.500L
6'-0"

3'-0"
Strand Mild
Aps, in²: 0.00 As, in²: 0.44
cgx, in: 0.00 cgx, in: 6.00
cgy, in: 0.00 cgy, in: 4.00
ex, in: 0.00
ey, in: 0.00

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 4


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

PROJECT: LOCATION: JOB NO.:


Burnt store lakes Project Location

CLIENT: ENGINEER: CHECKER: DATE:


ONX Checker 04/13/23

1'-0" DESIGN THICKNESS 8"


DESIGN WIDTH 1'-0"
DESIGN HEIGHT 6'-0"
1½"
5"

8"
1½"

1" 10" 1" (4) #3 x 5'-10"

Section View (0.50L - 3'-0")

CONCRETE MIX: CONCRETE AT RELEASE (f'ci): CONCRETE AT 28 DAYS (f'c): CONCRETE DENSITY:
Standard Mix 3500 psi 6000 psi 150 pcf
PRIMARY TOP REINFORCEMENT: (2) #3 x 5'-10"

PRIMARY BOT REINFORCEMENT: (2) #3 x 5'-10"

STRIPPING & BLOCKING DETAIL


STRIP WITH: REVISION: DESIGN NUMBER:

Strip
ERECT WITH: 1
Erection

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 5


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Loading Summary
Concentrated Load Summary
ID Type Dir Ecc, in Description
Dc Vert. -0.940 k at 6.00 ft 3.000 LOAD FROM WALL
Dc Vert. -3.650 k at 6.00 ft 3.000 LOAD FROM TRUSS
L Vert. -0.770 k at 6.00 ft 3.000 LOAD FROM TRUSS

Distributed Load Summary


ID Type Dir Description
He Horz. -0.205 k / ft at 0.00 ft to 0.000 k / ft at 3.42 ft External Soil Load
He Horz. -0.020 k / ft at 0.00 ft to -0.020 k / ft at 3.42 ft External Soil Surcharge
Hi Horz. 0.360 k / ft at 0.00 ft to 0.000 k / ft at 6.00 ft Internal Soil Load
Hi Horz. 0.020 k / ft at 0.00 ft to 0.020 k / ft at 6.00 ft Internal Soil Surcharge
SW Vert. -0.100 k / ft at 0.00 ft to -0.100 k / ft at 6.00 ft Self Weight

Point Moment Summary


Design contains no point moments

Load Patterns Summary


ID Wind Soil Loads Seismic Loads Live Loads
All Left Right L-R R-L
Pressure Suction External Internal Positive Negative
Alternate Alternate
1 - - ✓ - - - ✓ - - - -
2 - - - ✓ - - ✓ - - - -

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 6


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Project Information Panel Properties


Project: Burnt store lakes Location: Project Location Date: 04/13/23 f'ci: 3.5 ksi f'c: 6.0 ksi Δlim: 0.48 in
Client: ONX Designer: Job #: Δ T: 30.0 F° Initial Bow: 0.0 in Δ Max: 0.02/0.00 in
Description: Foundation panel
Specification: ACI 318-14, PCI Design Handbook 8ᵗʰ Edition

Loading [ ID - Load Case - Direction - Magnitude (k / plf) ] Ultimate Reactions (Elevation, Magnitude (k), Direction)
LOAD FROM WALL Dy 0.94 LOAD FROM TRUSS Dy 3.65 Ly 0.77 0" 1.53 → 0" 7.46 ↓ 0" 0.36 ←
Ext. Grade- 3'-5" w/ 40.0 psf surcharge 6'-0" 0.50 → 6'-0" 0.42 ←
Int. Grade- 6'-0" w/ 40.0 psf surcharge

Stripping Interaction Diagram (Controlling Section @ 1.00L / 71.9 in)

Stripping analysis not performed

500
Transportation

400
Transportation analysis not performed

Axial Capacity (k)


300
Stage: Erection

200
Erection analysis not performed
100

Stage: In-Place
Shear LC: LC 2 - 1.2D + 1.6L + 0.5R + 1.0T + 1.6H
Flexure LC: LC 2 - 1.2D + 1.6L + 0.5R + 1.0T + 1.6H
0

Shear Utilization: 0.21 (-1.5 k / -7.4 k) Max Comp.: 211 psi / 3600 psi
Flexure Utilization: 0.58 (-1.7 k-ft / -2.2 k-ft) Max Tension: 94 psi / 581 psi -60 -40 -20 0 20 40 60
Axial Utilization: 0.03 (7.5 k/ 254.6 k) Moment Capacity (k-ft)

1'-0"
P1,P2

6'-0"
H2
H1

0.6 0.3 0.0 300 150 0 100 50 0


Flexure Utilization Comp. Stress Tension Stress
Structural Model Front Elevation - Not to Scale (Mu/ϕMn) (psi) (psi)
1 Design Parameters
1.1 Section
8 INCH Properties
WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 7
Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ


(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
0.60 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
1.20 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
1.80 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
2.40 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
3.00 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
3.60 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
4.20 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
4.80 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
5.40 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00
6.00 12.00 8.00 96.00 6.00 4.00 512 1152 1664 0.00 0.00

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 8


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Detailed Flexure Capacity


Load Combination : All Combinations

Location : 5.99' (0.999 L) - LC 2 - Controlling

Y
X
Cross Section
Capacity Parameters Flexure Parameters Concrete Properties
Utilization : 0.577 Pu : 6.741 k f'c : 6000.0 psi λ : 1.00
ϕMnx : -2.199 k-ft Mx : -1.688 k-ft Ec : 4696.0 ksi wc : 150.0 pcf
ϕPn, Compression : 254.592 k εcu : 0.003 in/in Rebar Properties
ϕPn, Tension : 0.000 k c : 0.226 in
Section does not contain any rebar.
Pcrit : 1763.028 k θ : -180.000 deg
ϕ : 0.650 Height : 8.000 in Mesh Properties
ϕTension : 0.900 CGx : 6.000 in fy : ksi Es : ksi
ϕCompression : 0.650 CGy : 4.000 in Strand Properties
Section does not contain any strand.
Concrete Force
Method: Whitney Stress Block
β : 0.750
a : 0.169 in
Compression Area : 2.033 in²
Force Centroid, Cx : 6.000 in
Cy : 0.085 in
Compression Force : -10.370 k

Mild Tension Force


Section contains no mild reinforcement in tension.
Mild Compression Force
Sections contains no mild reinforcement in compression
Prestressed Reinforcement Force
Design contains to prestressed reinforcement

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 9


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Resistance Factor Axial Capacity Convergence Check


εmax : 10⁻³ in/in ϕ : 0.650 Ag : 96.00 in² Pu /ϕ : -10.370 k

Flexure Capacity Astr : 0.000 in² Fconc : -10.370 k


Apt : 0.000 in² Fmild : 0.000 k
x Axis
fse : 0.00 ksi Fstrand : 0.000 k
Mconc : -3.384 k-ft ϕPn Comp : 254.592 k Total : 0.000 k
Mmild : 0.000 k-ft ϕPn Tens : 0.000 k
Mstrand : 0.000 k-ft
Plain Concrete Strength
Mnx : -3.384 k-ft ϕMnx : 2.928 k-ft

ϕMnx : -2.199 k-ft

ϕMn vs ϕPn
Mn vs Pn
500

Demand ⬤
400 300
Axial Capacity (k)
200 100
0

-60 -40 -20 0 20 40 60


Moment Capacity (k-ft)
PM Diagram
(Loading angle fixed at 180.00 deg)

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 10


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 11


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

2.1 In-Place Strength Summary


All Combinations
2.1.1 Reaction Forces
Out-of-plane
Location Towards Interior Towards Exterior
0" 1.53 k 0.36 k
6'-0" 0.50 k 0.42 k
2.1.2 Flexure
2.1.2.1 Summary Table
Loc. Util. Mu Φ ΦMn Mcr Pu ΦPn c θ As A's Aps Loss d
(ft) (k-ft) (k-ft) (k-ft) (k) (k) (in) (deg) (in²) (in²) (in²) (%) (in)
0.00 0.00 0.0 0.65 2.4 6.9 7.3 254.6 0.24 0.0 0.00 0.00 0.00 0.00 0.00
0.30 0.08 -0.4 0.90 -4.8 -6.6 4.6 258.7 0.36 180.0 0.19 0.00 0.00 0.00 4.00
0.60 0.08 -0.7 0.90 -8.8 -6.6 4.6 264.3 0.69 180.0 0.44 0.00 0.00 0.00 4.00
0.90 0.12 -1.1 0.90 -9.6 -6.9 7.4 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
1.20 0.15 -1.4 0.90 -9.6 -6.9 7.3 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
1.50 0.17 -1.7 0.90 -9.6 -6.9 7.3 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
1.80 0.19 -1.9 0.90 -9.6 -6.9 7.2 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
2.10 0.21 -2.0 0.90 -9.6 -6.9 7.2 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
2.40 0.22 -2.2 0.90 -9.6 -6.9 7.2 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
2.70 0.23 -2.2 0.90 -9.6 -6.9 7.1 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
3.00 0.24 -2.3 0.90 -9.6 -6.9 7.1 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
3.30 0.24 -2.3 0.90 -9.6 -6.9 7.1 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
3.42 0.24 -2.3 0.90 -9.6 -6.9 7.1 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
3.60 0.24 -2.3 0.90 -9.5 -6.9 7.0 267.2 0.75 180.0 0.44 0.00 0.00 0.00 4.00
3.90 0.24 -2.3 0.90 -9.5 -6.9 7.0 267.2 0.74 180.0 0.44 0.00 0.00 0.00 4.00
4.20 0.24 -2.3 0.90 -9.5 -6.9 7.0 267.2 0.74 180.0 0.44 0.00 0.00 0.00 4.00
4.50 0.23 -2.2 0.90 -9.5 -6.9 6.9 267.2 0.74 180.0 0.44 0.00 0.00 0.00 4.00
4.80 0.22 -2.1 0.90 -9.5 -6.9 6.9 267.2 0.74 180.0 0.44 0.00 0.00 0.00 4.00
5.10 0.21 -2.0 0.90 -9.5 -6.9 6.8 267.2 0.74 180.0 0.44 0.00 0.00 0.00 4.00
5.40 0.20 -1.9 0.90 -9.5 -6.9 6.8 267.2 0.74 180.0 0.44 0.00 0.00 0.00 4.00
5.70 0.19 -1.8 0.90 -9.5 -6.9 6.8 267.2 0.74 180.0 0.44 0.00 0.00 0.00 4.00
5.99 0.58 -1.7 0.65 -2.2 -6.9 6.7 254.6 0.23 180.0 0.00 0.00 0.00 0.00 0.00
6.00 0.58 -1.7 0.65 -2.2 -6.9 6.7 254.6 0.23 180.0 0.00 0.00 0.00 0.00 0.00
2.1.3 Shear
2.1.3.1 Summary Table
Loc. Util Vu ϕVn Vc Vs Req b wd Av Min
(ft) (k) (k) (k) (k) (in²) (in²/ft)
0.00 0.21 -1.5 7.4 -9.9 0.0 0.0 0.000
0.30 0.18 -1.4 7.4 -9.9 0.0 48.0 0.000
0.60 0.16 -1.2 7.4 -9.9 0.0 48.0 0.000
0.90 0.14 -1.0 7.4 -9.9 0.0 48.0 0.000
1.20 0.12 -0.9 7.4 -9.9 0.0 48.0 0.000
1.50 0.10 -0.7 7.4 -9.9 0.0 48.0 0.000
1.80 0.08 -0.6 7.4 -9.9 0.0 48.0 0.000
2.10 0.06 -0.5 7.4 -9.9 0.0 48.0 0.000
2.40 0.05 -0.3 7.4 -9.9 0.0 48.0 0.000
2.70 0.05 -0.4 7.4 -9.9 0.0 48.0 0.000
3.00 0.05 -0.4 7.4 -9.9 0.0 48.0 0.000
3.30 0.06 -0.4 7.4 -9.9 0.0 48.0 0.000
3.42 0.06 -0.4 7.4 -9.9 0.0 48.0 0.000
3.60 0.06 -0.4 7.4 -9.9 0.0 48.0 0.000
3.90 0.06 -0.4 7.4 -9.9 0.0 48.0 0.000
4.20 0.06 -0.4 7.4 -9.9 0.0 48.0 0.000
4.50 0.06 -0.4 7.4 -9.9 0.0 48.0 0.000
4.80 0.06 -0.4 7.4 -9.9 0.0 48.0 0.000
5.10 0.06 0.4 7.4 9.9 0.0 48.0 0.000
5.40 0.06 0.5 7.4 9.9 0.0 48.0 0.000
5.70 0.07 0.5 7.4 9.9 0.0 48.0 0.000
6.00 0.07 0.5 7.4 9.9 0.0 0.0 0.000
2.1.4 Axial
2.1.4.1 Summary Table

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 12


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

Loc. Util. Pu ΦPn (C) ΦPn (T) ΦPcrit As Aps Loss Ag


(ft) (k) (k) (k) (k) (in²) (in²) (%) (in²)
0.00 0.03 7.46 254.59 0.00 ∞ 0.00 0.00 0.00 96.00
0.30 0.03 7.42 258.67 10.30 1763.03 0.44 0.00 0.00 96.00
0.60 0.03 7.39 264.33 23.76 1763.03 0.44 0.00 0.00 96.00
0.90 0.03 7.35 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
1.20 0.03 7.32 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
1.50 0.03 7.28 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
1.80 0.03 7.24 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
2.10 0.03 7.21 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
2.40 0.03 7.17 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
2.70 0.03 7.14 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
3.00 0.03 7.10 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
3.30 0.03 7.06 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
3.60 0.03 7.03 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
3.90 0.03 6.99 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
4.20 0.03 6.96 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
4.50 0.03 6.92 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
4.80 0.03 6.88 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
5.10 0.03 6.85 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
5.40 0.03 6.81 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
5.70 0.03 6.78 267.15 23.76 1763.03 0.44 0.00 0.00 96.00
5.99 0.03 6.74 254.59 0.00 1763.03 0.00 0.00 0.00 96.00
6.00 0.03 6.74 254.59 0.00 ∞ 0.00 0.00 0.00 96.00

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 13


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 14


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:00 pm

2.1.1 In-Place Service Summary


All Combinations
2.1.1.1 Tension
2.1.1.1.1 Summary Table
Location Tension Cracking M P
(ft) (psi) (psi) (k-ft) (k)
0.0 0.0 580.9 0.00 5.2
0.3 0.0 580.9 0.03 5.2
0.6 0.0 580.9 0.04 5.1
0.9 15.5 580.9 -0.73 5.1
1.2 32.9 580.9 -0.91 5.1
1.5 47.7 580.9 -1.07 5.0
1.8 60.1 580.9 -1.20 5.0
2.1 70.1 580.9 -1.30 5.0
2.4 78.0 580.9 -1.38 4.9
2.7 84.2 580.9 -1.53 5.7
3.0 89.1 580.9 -1.58 5.7
3.3 92.3 580.9 -1.61 5.6
3.6 94.0 580.9 -1.63 5.6
3.9 94.3 580.9 -1.62 5.6
4.2 93.3 580.9 -1.61 5.5
4.5 91.3 580.9 -1.59 5.5
4.8 88.2 580.9 -1.55 5.5
5.1 84.4 580.9 -1.51 5.4
5.4 80.0 580.9 -1.46 5.4
5.7 75.1 580.9 -1.40 5.4
6.0 69.8 580.9 -1.34 5.4
2.1.1.2 Total Compression
2.1.1.2.1 Summary Table
Location Comp. Limit M P
(ft) (psi) (psi) (k-ft) (k)
0.0 62.1 3600.0 0.00 6.0
0.3 88.6 3600.0 -0.29 5.9
0.6 112.0 3600.0 -0.54 5.9
0.9 132.5 3600.0 -0.76 5.9
1.2 150.2 3600.0 -0.95 5.8
1.5 165.3 3600.0 -1.12 5.8
1.8 178.0 3600.0 -1.26 5.8
2.1 188.3 3600.0 -1.37 5.7
2.4 196.5 3600.0 -1.46 5.7
2.7 202.7 3600.0 -1.53 5.7
3.0 207.0 3600.0 -1.58 5.7
3.3 209.6 3600.0 -1.61 5.6
3.6 210.7 3600.0 -1.63 5.6
3.9 210.3 3600.0 -1.62 5.6
4.2 208.7 3600.0 -1.61 5.5
4.5 206.0 3600.0 -1.59 5.5
4.8 202.4 3600.0 -1.55 5.5
5.1 198.0 3600.0 -1.51 5.4
5.4 192.9 3600.0 -1.46 5.4
5.7 187.4 3600.0 -1.40 5.4
6.0 181.5 3600.0 -1.34 5.4
2.1.1.3 Deflection
2.1.1.3.1 Summary Graph Legend
Deflection
0.50

Allowable
Deflection, in

Max Deflection: 0.020 in


0.25

Min Deflection: 0.000 in


0.00

0 7 14 22 29 36 43 50 58 65 72
Location, in:

8 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 15


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION WALL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
STRUCTURAL CALCULATION REPORT

FOUNDATION WALL DESIGN

1 ) Material properties
Clear cover = 1.5 in
Concrete grade f'c = 3000 Psi
Rebar grade = 60000 Psi

2 ) Foundation wall Geometry


Length of wall L = 1 ft
Height of wall h = 6 ft
Thickness of wall t = 8 in
Eccentricity e = 3 in

3 ) Load Details
P1.Load from Wall Above

Thickness of wall = 0.66 ft Length of wall = 1 ft


Height of wall = 9.5 ft
Load from Wall Above = (0.66 x 9.5 x 1 x 0.15) = 0.94 Kip

P2.Load from Roof Truss:

Dead Load Consideration on = 3.65 Kip/ft


foundation wall

Live Load Consideration on = 0.765 Kip/ft


foundation wall

4 ) Soil Load Detail


Soil Load Height (From Interior )= 6 ft
Soil Load Height (From Extirior )= 3.42 ft
Surcharge = 40 Psf

5 ) Analysis from Eriksson software


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION WALL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
STRUCTURAL CALCULATION REPORT

Dead load Reaction From Etabs ( 1.0 DL - SLS)

Dead Load from Wall Above = ( 1.57 + 2.75 + 2.75 + 2.81 + 2.96 +1.76 ) / 4

= 3.65 Kip
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION WALL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
STRUCTURAL CALCULATION REPORT

Live load Reaction From Etabs ( 1.0 LL + 1.0 Lr)

Live Load from Wall Above = ( 0.36 + 0.61 + 0.59 + 0.58 + 0.59 + 0.34 ) / 4

= 0.7675 Kip
Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Project Information
Project: Burnt store lakes Location: Project Location Date: 13/04/2023
Client: ONX Designer: Job No.:
Description: Foundation panel Spec: ACI 318-14
Material Properties
Concrete
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0
In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight

Rebar Mesh Strand


fy (ksi) 60 - fpu (ksi) -
Es (ksi) 29000 - Ep (ksi) -
Exterior Soil Interior Soil
Pressure Type: Grade Unit Weight (pcf): 120 Pressure Type: Grade Unit Weight (pcf): 120
Lateral Pressure Coef.: 0.5 Lateral Pressure Coef.: 0.5
Load Combinations
Strength Combinations Service Combinations
# D L R W E T H Include # D L R W E T H Include
1 1.4 0 0 0 0 1 1.6 1 1 0 0 0 0 0.75 1
2 1.2 1.6 0.5 0 0 1 1.6 2 1 1 0 0 0 0.75 1
3 1.2 1 1.6 0 0 1 1.6 3 1 0 1 0 0 0.75 1
4 1.2 0 1.6 0.5 0 1 1.6 4 1 0.75 0.75 0 0 0.75 1
5 1.2 1 0.5 1 0 1 1.6 5 1 0 0 0.6 0 0.75 1
6 1.2 1 0.2 0 1 1 1.6
7 0.9 0 0 1 0 1 1.6
8 0.9 0 0 0 1 1 1.6
Settings
Deflection Limits Stress Options Resistance Factors
Add initial bow to reported deflections Failure if cracked Developed Transfering
Tension 0.9 0.75
Additional Bow: 0" Ignore Lateral Strand Eccentricity
Compression 0.65 -
Total Deflection Limit: L / 150
Use Principal Axis Shear 0.75 -
Elastic Analysis
2nd Order Effects: P-Delta
In Place Stress Limits Development Multipliers
Analysis βd : Non-Sway Modulus of Rupture (psi): 7.5 √fc Strand (Normal): 1

R-Value Calculation Compression: 0.6 fc Strand (Debonded): 2


Handling Stress Limits Strand (Cut): 1
Concrete Resistance (k): 13.33
Tension: 7.5 √fc
Insulation Resistance (k): 0.238 Mild: 1
Compression: 0.6 fc Shear Options
Interior Resistance (R): 0.68
Flexure Options Treat as column
Exterior Resistance (R): 0.17 Method: Whitney Stress Block
Cracking Check: None Axial Options
Bottom Length Ignored: 0"
Ignore tensile strength failures
Top Length Ignored: 0"
Ignore buckling failures

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 1


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Concrete Extents
Panel Geometry
Top Elevation : 6'-0" Width : 1'-0" Thickness : 6"
Bottom Elevation : 0"
Height : 6'-0"
Section Type : Solid
Top in Form : Interior
Left Miter Right Miter
Left miter not included in design Right miter not included in design
Openings, Reveals, and Solid Zones
Wall design contains no openings, reveals, or solid zones.

6" 1'-0"

Area, in²: 72.00


Width, in: 12.00
Height, in: 6.00
Cx, in: 6.00
Cy, in: 3.00
6'-0"

6'-0"
Izz, in⁴: 216.00
Iyy, in⁴: 864.00
Izy, in⁴: 0.00
Sb, in³: 72.00
St, in³: 72.00

0.200L
1'-2⅜"

Side Elevation Front Elevation Section Properties


1'-0"
6"

Cross Section

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 2


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Structural Model
Restraints Releases
Add foundation connection Restrain Moment:
Design contains no releases.

Add floor tie


ID Elevation Type Gravity Rest. Thermal Rest. Stiffness (k/in)
1 0" Restrained -
2 6'-0" Restrained -

6.00 ft

Concentrated Loads Load Options


Load Components (k / kip-ft) Pattern Live Loads for Flexure
ID Elevation Ecc Dead Live Roof Pres. Suct. Seis.
↓ 0.94 0 0 0 0 0
P1 6'-0.0" -3.0"
→ 0 0 0 0 0 0 Selfweight eccentricity: 0"
↓ 3.65 0.77 0 0 0 0
P2 6'-0.0" -3.0" Eccentricity measured from: Panel CG
→ 0 0 0 0 0 0

Wind Loads
Design contains no wind loads
Seismic Loads
Zone Location(s): Full height
Apply multipliers to Deadload + Self weight
Start of Zone (x/L) End of Zone (x/L) Seismic Load (Cs, % of DL)
0.00 1.00 0.0

Temperature Loads Interior Soil Loads Exterior Soil Loads Additional Self Weight
Exterior Temperature (F°): 105 Elevation: 6'-0" Elevation: 3'-5" Start from Bottom: 0"
Interior Temperature (F°): 75 Surcharge (psf): 40 Surcharge (psf): 40 End from Top: 0"
Thermal Elasticity Multiplier: 1 Magnitude (plf): 0
Exterior

H1

P1,P2
H2

Interior
Structural Sections
No structural sections defined, using entire cross section.

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 3


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Reinforcement
Strands
Design contains no prestressing
Rebar
Depth to Loc. from Start from End from Start End
Size Area Diameter Quantity Spacing
CG Left Bottom Top Condition Condition
#3 0.11 0.375" 2 10" 3" 1" 1" 1" 90° Hook Anchored
Mesh
Design contains no mesh
Interrupts
Design contains no interrupts

1'-0"
1'-0"

3"
3"
1" 10" 1" (2) #3

0.500L
6'-0"

3'-0"
Strand Mild
Aps, in²: 0.00 As, in²: 0.22
cgx, in: 0.00 cgx, in: 6.00
cgy, in: 0.00 cgy, in: 3.00
ex, in: 0.00
ey, in: 0.00

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 4


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

PROJECT: LOCATION: JOB NO.:


Burnt store lakes Project Location

CLIENT: ENGINEER: CHECKER: DATE:


ONX Checker 04/13/23

DESIGN THICKNESS 6"


DESIGN WIDTH 1'-0"
1'-0" DESIGN HEIGHT 6'-0"
3"

6"
3"

1" 10" 1" (2) #3 x 5'-10"

Section View (0.50L - 3'-0")

CONCRETE MIX: CONCRETE AT RELEASE (f'ci): CONCRETE AT 28 DAYS (f'c): CONCRETE DENSITY:
Standard Mix 3500 psi 6000 psi 150 pcf
PRIMARY TOP REINFORCEMENT:

PRIMARY BOT REINFORCEMENT:

STRIPPING & BLOCKING DETAIL


STRIP WITH: REVISION: DESIGN NUMBER:

Strip
ERECT WITH: 1
Erection

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 5


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Loading Summary
Concentrated Load Summary
ID Type Dir Ecc, in Description
Dc Vert. -0.940 k at 6.00 ft 3.000 LOAD FROM WALL
Dc Vert. -3.650 k at 6.00 ft 3.000 LOAD FROM TRUSS
L Vert. -0.770 k at 6.00 ft 3.000 LOAD FROM TRUSS

Distributed Load Summary


ID Type Dir Description
He Horz. -0.205 k / ft at 0.00 ft to 0.000 k / ft at 3.42 ft External Soil Load
He Horz. -0.020 k / ft at 0.00 ft to -0.020 k / ft at 3.42 ft External Soil Surcharge
Hi Horz. 0.360 k / ft at 0.00 ft to 0.000 k / ft at 6.00 ft Internal Soil Load
Hi Horz. 0.020 k / ft at 0.00 ft to 0.020 k / ft at 6.00 ft Internal Soil Surcharge
SW Vert. -0.075 k / ft at 0.00 ft to -0.075 k / ft at 6.00 ft Self Weight

Point Moment Summary


Design contains no point moments

Load Patterns Summary


ID Wind Soil Loads Seismic Loads Live Loads
All Left Right L-R R-L
Pressure Suction External Internal Positive Negative
Alternate Alternate
1 - - ✓ - - - ✓ - - - -
2 - - - ✓ - - ✓ - - - -

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 6


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Project Information Panel Properties


Project: Burnt store lakes Location: Project Location Date: 04/13/23 f'ci: 3.5 ksi f'c: 6.0 ksi Δlim: 0.48 in
Client: ONX Designer: Job #: Δ T: 30.0 F° Initial Bow: 0.0 in Δ Max: 0.04/0.00 in
Description: Foundation panel
Specification: ACI 318-14, PCI Design Handbook 8ᵗʰ Edition

Loading [ ID - Load Case - Direction - Magnitude (k / plf) ] Ultimate Reactions (Elevation, Magnitude (k), Direction)
LOAD FROM WALL Dy 0.94 LOAD FROM TRUSS Dy 3.65 Ly 0.77 0" 1.54 → 0" 7.28 ↓ 0" 0.36 ←
Ext. Grade- 3'-5" w/ 40.0 psf surcharge 6'-0" 0.51 → 6'-0" 0.41 ←
Int. Grade- 6'-0" w/ 40.0 psf surcharge

Stripping Interaction Diagram (Controlling Section @ 1.00L / 71.9 in)

400
Stripping analysis not performed

350
Transportation

150 200 250 300


Transportation analysis not performed

Axial Capacity (k)


Stage: Erection

Erection analysis not performed


100

Stage: In-Place
50

Shear LC: LC 2 - 1.2D + 1.6L + 0.5R + 1.0T + 1.6H


Flexure LC: LC 2 - 1.2D + 1.6L + 0.5R + 1.0T + 1.6H
0

Shear Utilization: 0.28 (-1.5 k / -5.6 k) Max Comp.: 349 psi / 3600 psi
Flexure Utilization: 0.98 (-1.7 k-ft / -1.6 k-ft) Max Tension: 195 psi / 581 psi -30 -20 -10 0 10 20 30
Axial Utilization: 0.04 (7.3 k/ 190.9 k) Moment Capacity (k-ft)

1'-0"
P1,P2

6'-0"
H2
H1

1.0 0.5 0.0 400 200 0 200 100 0


Flexure Utilization Comp. Stress Tension Stress
Structural Model Front Elevation - Not to Scale (Mu/ϕMn) (psi) (psi)
1 Design Parameters
1.1 Section
6 INCH Properties
WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 7
Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ


(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
0.60 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
1.20 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
1.80 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
2.40 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
3.00 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
3.60 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
4.20 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
4.80 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
5.40 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00
6.00 12.00 6.00 72.00 6.00 3.00 216 864 1080 0.00 0.00

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 8


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Detailed Flexure Capacity


Load Combination : All Combinations

Location : 5.99' (0.999 L) - LC 2 - Controlling

Y
X

Cross Section
Capacity Parameters Flexure Parameters Concrete Properties
Utilization : 0.975 Pu : 6.740 k f'c : 6000.0 psi λ : 1.00
ϕMnx : -1.637 k-ft Mx : -1.688 k-ft Ec : 4696.0 ksi wc : 150.0 pcf
ϕPn, Compression : 190.944 k εcu : 0.003 in/in Rebar Properties
ϕPn, Tension : 0.000 k c : 0.226 in
Section does not contain any rebar.
Pcrit : 743.805 k θ : -180.000 deg
ϕ : 0.650 Height : 6.000 in Mesh Properties
ϕTension : 0.900 CGx : 6.000 in fy : ksi Es : ksi
ϕCompression : 0.650 CGy : 3.000 in Strand Properties
Section does not contain any strand.
Concrete Force
Method: Whitney Stress Block
β : 0.750
a : 0.169 in
Compression Area : 2.033 in²
Force Centroid, Cx : 6.000 in
Cy : 0.085 in
Compression Force : -10.370 k

Mild Tension Force


Section contains no mild reinforcement in tension.
Mild Compression Force
Sections contains no mild reinforcement in compression
Prestressed Reinforcement Force
Design contains to prestressed reinforcement

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 9


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Resistance Factor Axial Capacity Convergence Check


εmax : 10⁻³ in/in ϕ : 0.650 Ag : 72.00 in² Pu /ϕ : -10.370 k

Flexure Capacity Astr : 0.000 in² Fconc : -10.370 k


Apt : 0.000 in² Fmild : 0.000 k
x Axis
fse : 0.00 ksi Fstrand : 0.000 k
Mconc : -2.519 k-ft ϕPn Comp : 190.944 k Total : 0.000 k
Mmild : 0.000 k-ft ϕPn Tens : 0.000 k
Mstrand : 0.000 k-ft
Plain Concrete Strength
Mnx : -2.519 k-ft ϕMnx : 1.731 k-ft

ϕMnx : -1.637 k-ft

ϕMn vs ϕPn
Mn vs Pn
400

Demand ⬤
350
300 250
Axial Capacity (k)
150 200
100
50
0

-30 -20 -10 0 10 20 30


Moment Capacity (k-ft)
PM Diagram
(Loading angle fixed at 180.00 deg)

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 10


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 11


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

2.1 In-Place Strength Summary


All Combinations
2.1.1 Reaction Forces
Out-of-plane
Location Towards Interior Towards Exterior
0" 1.54 k 0.36 k
6'-0" 0.51 k 0.41 k
2.1.2 Flexure
2.1.2.1 Summary Table
Loc. Util. Mu Φ ΦMn Mcr Pu ΦPn c θ As A's Aps Loss d
(ft) (k-ft) (k-ft) (k-ft) (k) (k) (in) (deg) (in²) (in²) (in²) (%) (in)
0.00 0.00 0.0 0.65 1.7 4.0 7.1 190.9 0.24 0.0 0.00 0.00 0.00 0.00 0.00
0.30 0.17 -0.4 0.90 -2.3 -3.8 4.5 193.0 0.23 180.0 0.10 0.00 0.00 0.00 3.00
0.60 0.19 -0.8 0.90 -3.9 -3.8 4.5 195.8 0.40 180.0 0.22 0.00 0.00 0.00 3.00
0.90 0.27 -1.1 0.90 -3.9 -3.8 4.5 197.2 0.40 180.0 0.22 0.00 0.00 0.00 3.00
1.20 0.34 -1.3 0.90 -3.9 -3.8 4.5 197.2 0.40 180.0 0.22 0.00 0.00 0.00 3.00
1.50 0.39 -1.5 0.90 -3.9 -3.8 4.4 197.2 0.39 180.0 0.22 0.00 0.00 0.00 3.00
1.80 0.43 -1.7 0.90 -3.9 -3.8 4.4 197.2 0.39 180.0 0.22 0.00 0.00 0.00 3.00
2.10 0.47 -1.8 0.90 -3.9 -3.8 4.4 197.2 0.39 180.0 0.22 0.00 0.00 0.00 3.00
2.40 0.49 -1.9 0.90 -3.9 -3.8 4.4 197.2 0.39 180.0 0.22 0.00 0.00 0.00 3.00
2.70 0.51 -2.3 0.90 -4.5 -4.0 7.0 197.2 0.46 180.0 0.22 0.00 0.00 0.00 3.00
3.00 0.52 -2.3 0.90 -4.5 -4.0 7.0 197.2 0.46 180.0 0.22 0.00 0.00 0.00 3.00
3.30 0.53 -2.3 0.90 -4.4 -4.0 7.0 197.2 0.46 180.0 0.22 0.00 0.00 0.00 3.00
3.42 0.53 -2.3 0.90 -4.4 -4.0 7.0 197.2 0.46 180.0 0.22 0.00 0.00 0.00 3.00
3.60 0.53 -2.3 0.90 -4.4 -4.0 7.0 197.2 0.46 180.0 0.22 0.00 0.00 0.00 3.00
3.90 0.52 -2.3 0.90 -4.4 -4.0 6.9 197.2 0.46 180.0 0.22 0.00 0.00 0.00 3.00
4.20 0.51 -2.3 0.90 -4.4 -4.0 6.9 197.2 0.45 180.0 0.22 0.00 0.00 0.00 3.00
4.50 0.50 -2.2 0.90 -4.4 -4.0 6.9 197.2 0.45 180.0 0.22 0.00 0.00 0.00 3.00
4.80 0.48 -2.1 0.90 -4.4 -4.0 6.8 197.2 0.45 180.0 0.22 0.00 0.00 0.00 3.00
5.10 0.46 -2.0 0.90 -4.4 -4.0 6.8 197.2 0.45 180.0 0.22 0.00 0.00 0.00 3.00
5.40 0.44 -1.9 0.90 -4.4 -4.0 6.8 197.2 0.45 180.0 0.22 0.00 0.00 0.00 3.00
5.70 0.41 -1.8 0.90 -4.4 -4.0 6.8 197.2 0.45 180.0 0.22 0.00 0.00 0.00 3.00
5.99 0.98 -1.7 0.65 -1.6 -4.0 6.7 190.9 0.23 180.0 0.00 0.00 0.00 0.00 0.00
6.00 0.97 -1.7 0.65 -1.6 -4.0 6.7 190.9 0.23 180.0 0.00 0.00 0.00 0.00 0.00
2.1.3 Shear
2.1.3.1 Summary Table
Loc. Util Vu ϕVn Vc Vs Req b wd Av Min
(ft) (k) (k) (k) (k) (in²) (in²/ft)
0.00 0.28 -1.5 5.6 -7.4 0.0 0.0 0.000
0.30 0.24 -1.4 5.6 -7.4 0.0 36.0 0.000
0.60 0.21 -1.2 5.6 -7.4 0.0 36.0 0.000
0.90 0.19 -1.0 5.6 -7.4 0.0 36.0 0.000
1.20 0.16 -0.9 5.6 -7.4 0.0 36.0 0.000
1.50 0.13 -0.7 5.6 -7.4 0.0 36.0 0.000
1.80 0.11 -0.6 5.6 -7.4 0.0 36.0 0.000
2.10 0.08 -0.5 5.6 -7.4 0.0 36.0 0.000
2.40 0.06 -0.3 5.6 -7.4 0.0 36.0 0.000
2.70 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
3.00 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
3.30 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
3.42 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
3.60 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
3.90 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
4.20 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
4.50 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
4.80 0.07 -0.4 5.6 -7.4 0.0 36.0 0.000
5.10 0.08 0.4 5.6 7.4 0.0 36.0 0.000
5.40 0.08 0.5 5.6 7.4 0.0 36.0 0.000
5.70 0.09 0.5 5.6 7.4 0.0 36.0 0.000
6.00 0.09 0.5 5.6 7.4 0.0 0.0 0.000
2.1.4 Axial
2.1.4.1 Summary Table

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 12


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

Loc. Util. Pu ΦPn (C) ΦPn (T) ΦPcrit As Aps Loss Ag


(ft) (k) (k) (k) (k) (in²) (in²) (%) (in²)
0.00 0.04 7.28 190.94 0.00 ∞ 0.00 0.00 0.00 72.00
0.30 0.04 7.25 192.99 5.15 743.81 0.22 0.00 0.00 72.00
0.60 0.04 7.23 195.81 11.88 743.81 0.22 0.00 0.00 72.00
0.90 0.04 7.20 197.22 11.88 743.81 0.22 0.00 0.00 72.00
1.20 0.04 7.17 197.22 11.88 743.81 0.22 0.00 0.00 72.00
1.50 0.04 7.14 197.22 11.88 743.81 0.22 0.00 0.00 72.00
1.80 0.04 7.12 197.22 11.88 743.81 0.22 0.00 0.00 72.00
2.10 0.04 7.09 197.22 11.88 743.81 0.22 0.00 0.00 72.00
2.40 0.04 7.06 197.22 11.88 743.81 0.22 0.00 0.00 72.00
2.70 0.04 7.04 197.22 11.88 743.81 0.22 0.00 0.00 72.00
3.00 0.04 7.01 197.22 11.88 743.81 0.22 0.00 0.00 72.00
3.30 0.04 6.98 197.22 11.88 743.81 0.22 0.00 0.00 72.00
3.60 0.04 6.96 197.22 11.88 743.81 0.22 0.00 0.00 72.00
3.90 0.04 6.93 197.22 11.88 743.81 0.22 0.00 0.00 72.00
4.20 0.03 6.90 197.22 11.88 743.81 0.22 0.00 0.00 72.00
4.50 0.03 6.88 197.22 11.88 743.81 0.22 0.00 0.00 72.00
4.80 0.03 6.85 197.22 11.88 743.81 0.22 0.00 0.00 72.00
5.10 0.03 6.82 197.22 11.88 743.81 0.22 0.00 0.00 72.00
5.40 0.03 6.79 197.22 11.88 743.81 0.22 0.00 0.00 72.00
5.70 0.03 6.77 197.22 11.88 743.81 0.22 0.00 0.00 72.00
5.99 0.04 6.74 190.94 0.00 743.81 0.00 0.00 0.00 72.00
6.00 0.04 6.74 190.94 0.00 ∞ 0.00 0.00 0.00 72.00

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 13


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 14


Eriksson Wall v4.2.0 Licensee: ONX INC 04/12/2023 5:02 pm

2.1.1 In-Place Service Summary


All Combinations
2.1.1.1 Tension
2.1.1.1.1 Summary Table
Location Tension Cracking M P
(ft) (psi) (psi) (k-ft) (k)
0.0 0.0 580.9 0.00 5.0
0.3 0.0 580.9 0.03 5.0
0.6 17.5 580.9 -0.52 5.0
0.9 53.3 580.9 -0.73 5.0
1.2 84.2 580.9 -0.92 4.9
1.5 110.5 580.9 -1.07 4.9
1.8 132.3 580.9 -1.20 4.9
2.1 150.9 580.9 -1.38 5.7
2.4 166.4 580.9 -1.47 5.6
2.7 178.2 580.9 -1.54 5.6
3.0 186.8 580.9 -1.59 5.6
3.3 192.3 580.9 -1.62 5.6
3.6 195.0 580.9 -1.63 5.5
3.9 195.2 580.9 -1.63 5.5
4.2 193.2 580.9 -1.62 5.5
4.5 189.2 580.9 -1.59 5.5
4.8 183.4 580.9 -1.55 5.4
5.1 176.3 580.9 -1.51 5.4
5.4 167.9 580.9 -1.46 5.4
5.7 158.7 580.9 -1.40 5.4
6.0 148.9 580.9 -1.34 5.4
2.1.1.2 Total Compression
2.1.1.2.1 Summary Table
Location Comp. Limit M P
(ft) (psi) (psi) (k-ft) (k)
0.0 80.7 3600.0 0.00 5.8
0.3 128.2 3600.0 -0.29 5.8
0.6 170.3 3600.0 -0.54 5.8
0.9 207.1 3600.0 -0.76 5.7
1.2 239.0 3600.0 -0.96 5.7
1.5 266.3 3600.0 -1.12 5.7
1.8 289.2 3600.0 -1.26 5.7
2.1 307.9 3600.0 -1.38 5.7
2.4 322.7 3600.0 -1.47 5.6
2.7 334.0 3600.0 -1.54 5.6
3.0 342.0 3600.0 -1.59 5.6
3.3 346.8 3600.0 -1.62 5.6
3.6 348.9 3600.0 -1.63 5.5
3.9 348.5 3600.0 -1.63 5.5
4.2 345.8 3600.0 -1.62 5.5
4.5 341.2 3600.0 -1.59 5.5
4.8 334.8 3600.0 -1.55 5.4
5.1 327.0 3600.0 -1.51 5.4
5.4 318.1 3600.0 -1.46 5.4
5.7 308.2 3600.0 -1.40 5.4
6.0 297.8 3600.0 -1.34 5.4
2.1.1.3 Deflection
2.1.1.3.1 Summary Graph Legend
Deflection
0.50

Allowable
Deflection, in

Max Deflection: 0.035 in


0.25

Min Deflection: 0.000 in


0.00

0 7 14 22 29 36 43 50 58 65 72
Location, in:

6 INCH WALL.ewf Copyright © 2017-2021 Eriksson Software pg. 15


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : FOUNDATION BASE SLAB DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
STRUCTURAL CALCULATION REPORT

SOIL PRESSURE CHECK FOR FOUNDATION SUBJECTED TO ECCENTRIC BEARING OF WALL

1 ) Material properties
Clear cover = 1.5 in
Concrete grade f'c = 6000 Psi
Rebar grade = 60000 Psi

2 ) Footing Geometry
Footing Base Slab Width B = 1.5 ft
Footing Base Slab Depth tb = 8 in
Footing Wall Height h = 5.33 ft
Footing Wall Thickness tw = 8 in

3 ) Soil Load Height


Soil Load Height (From Interior )= 6 ft
Soil Load Height (From Extirior )= 1.75 ft

4 ) Load Consideration
P1.Load from Wall Above

Thickness of wall = 0.66 ft Length of wall = 1 ft


Height of wall = 9.5 ft

Load from Wall Above = (0.66 x 9.5 x 1 x 0.15) = 0.94 Kip

P2.Load from Roof Truss:

Dead Load Consideration on = 3.65 Kip/ft


foundation wall

Live Load Consideration on = 0.765 Kip/ft


foundation wall
Eccentricity e = 4 in

Actual bearing capacity = 8.7 Psi (Refer Prokon report detail)

= 4.8 X 144

= 1252.8 Psf

Allowable bearing capacity = 2500 Psf (refer soil report)

Soil pressure = 1253 < 2500 Psf Hence OK


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Retaining Wall Design : Ver W3.0.04 - 03 Apr 2017


Title : Cantilever wall example
C14
Input Data

Wall Dimensions Unfactored Live Loads General Parameters Design Parameters


H1 (ft) 6 C (ft) 0.67 W (psi) 0.27 Soil frict f (°) 30 SF Overt. 2
H2 (ft) 2 F (ft) 0 P (kip) 4 Fill slope b (°) 0 SF Slip 1.5
H3 (ft) 2 xf (ft) 0 xp (ft) 0.66 Wall frict d (°) 16 ULS DL Factor 1.2
Hw (ft) 0 At (ft) 0.66 L (kip/ft) 0.95 r Conc lb/ft3 150 ULS LL Factor 1.6
Hr (ft) 1.18 Ab (ft) 0.66 xl (ft) 0.33 r Soil lb/ft3 120 Pmax (psi) 17.36
B (ft) 0.42 Cov wall in 3 Lh (kip/ft) 0.000 fc' (psi) 6000 Soil Poisson u 0.5
D (ft) 0.42 Cov base in 1.5 x (ft) 0 fy (psi) 60000 DLFac Slide/Ovt 0.9

Seepage allowed
Active pressure applied on back of shear key for sliding

Theory : Coulomb
Wall type : Cantilever

SEISMIC ANALYSIS SETTINGS:

Seismic Analysis ON/OFF:OFF

Hor Accel. (g) 0.02


Vert Accel. (g) 0.01
Include LL's Y

VALUES OF PRESSURE COEFFICIENTS:


Active Pressure coefficient Ka :0.300 (User Defined)
Passive Pressure coefficient Kp :3.000 (User Defined)
Base frictional constant µ :0.577 (User Defined)

FORCES ACTING ON THE WALL AT SLS:


All forces/moments are per ft width

FORCES (kip) and their LEVER ARMS (ft)


Description F Horizontal Lever arm F Vertical Lever arm
left (+) down (+)
Destabilizing forces:
Total Active pressure Pa 0.277 1.333 0.079 1.080
As a result of surcharge w 0.045 2.000 0.013 1.080

Stabilizing forces:
Passive pressure on base Pp -0.720 0.667
Weight of the wall + base 0.678 0.750
Weight of soil on the base 0.235 0.982
Point load of 4.00 kN on wall 0.667 1.080
Line load of 0.95 kN/m on backfill 0.950 0.750
UDL of 0.3 psi 0.016 1.290

EQUILIBRIUM CALCULATIONS AT SLS


All forces/moments are per ft width

1.Moment Equilibrium

Point of rotation: bottom front corner of base.

For Overturning moment Mo calculate as follows:


Mo = Sum(hor. forces x l.a.) - Sum(vert. forces x l.a.)
For Stabilizing moment Mr calculate as follows:
Mr = -Sum(hor. forces x l.a.) + Sum(vert. forces x l.a.)
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

where l.a. = lever arm of each force.

Stabilizing moment Mr : 2.67 kipft


Destabilizing moment Mo : 0.36 kipft

Safety factor against overturning = Mr/Mo = 7.441

2.Force Equilibrium at SLS

Sum of Vertical forces Pv : 2.64 kip


Frictional resistance Pfric : 1.52 kip
Passive Pressure on shear key : 0.00 kip
Passive pressure on base : 720.00 kip
=> Total Horiz. resistance Fr : 721.52 kip

Horizontal sliding force on wall Fhw : 0.32 kip


Horizontal sliding force on shear key Fht : 0.00 kip
=> Total Horizontal sliding force Fh : 0.32 kip

Safety factor against overall sliding = Fr/Fh = 2242.898

FORCES ACTING ON THE WALL AT ULS:


All forces/moments are per ft width

FORCES (kip) and their LEVER ARMS (ft)


Description F Horizontal Lever arm F Vertical Lever arm
left (+) down (+)
Destabilizing forces:
Total Active pressure Pa 0.332 1.333 0.095 1.080
As a result of surcharge w 0.072 2.000 0.021 1.080

Stabilizing forces:
Passive pressure on base Pp -0.648 0.667
Weight of the wall + base 0.611 0.750
Weight of soil on the base 0.211 0.982
Point load of 3.60 kN on wall 0.600 1.080
Line load of 0.85 kN/m on backfill 0.855 0.750
UDL of 0.2 psi 0.015 1.290

EQUILIBRIUM CALCULATIONS AT ULS


All forces/moments are per ft width

1.Moment Equilibrium

Point of rotation: bottom front corner of base.

For Overturning moment Mo calculate as follows:


Mo = Sum(hor. forces x l.a.) - Sum(vert. forces x l.a.)
For Stabilizing moment Mr calculate as follows:
Mr = -Sum(hor. forces x l.a.) + Sum(vert. forces x l.a.)
where l.a. = lever arm of each force.

Stabilizing moment Mr : 10.70 kipft


Destabilizing moment Mo : 2.05 kipft

Safety factor against overturning = Mr/Mo = 5.214

2.Force Equilibrium at ULS

Sum of Vertical forces Pv : 2.37 kip


Frictional resistance Pfric : 1.37 kip
Passive Pressure on shear key : 0.00 kip
Passive pressure on base : 648.00 kip
=> Total Horiz. resistance Fr : 649.37 kip

Horizontal sliding force on wall Fhw : 5.90 kip


Horizontal sliding force on shear key Fht : 0.00 kip
=> Total Horizontal sliding force Fh : 5.90 kip
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Safety factor against overall sliding = Fr/Fh = 110.147

SOIL PRESSURES UNDER BASE AT SLS

Maximum pressure : 8.70 psi


Minimum pressure : 2.84 psi
Maximum pressure occurs at right hand side of base

WALL MOMENTS (ULS) AND REINFORCEMENT TO ACI 318 - 2014

Position from Moment Front Reinforcing Back Reinforcing Minimum


base top (ft) (kipft) (in²/ft) (in²/ft) (in²/ft)

0.00 0.163 0.000 0.008 0.211


0.11 0.000 0.000 0.000 0.211
0.21 0.000 0.000 0.000 0.211
0.32 0.000 0.000 0.000 0.211
0.43 0.000 0.000 0.000 0.211
0.53 0.000 0.000 0.000 0.211
0.64 0.000 0.000 0.000 0.211
0.75 0.000 0.000 0.000 0.211
0.85 0.000 0.000 0.000 0.211
0.96 0.000 0.000 0.000 0.211
1.07 0.000 0.000 0.000 0.211
1.17 0.000 0.000 0.000 0.211
1.28 0.000 0.000 0.000 0.211
1.39 0.000 0.000 0.000 0.211
1.49 0.000 0.000 0.000 0.211
1.60 0.000 0.000 0.000 0.211
1.71 0.000 0.000 0.000 0.211
1.81 0.000 0.000 0.000 0.211
1.92 0.000 0.000 0.000 0.211
2.03 0.000 0.000 0.000 0.211
2.13 0.000 0.000 0.000 0.211
2.24 0.000 0.000 0.000 0.211
2.35 0.000 0.000 0.000 0.211
2.45 0.000 0.000 0.000 0.211
2.56 0.000 0.000 0.000 0.211
2.66 0.000 0.000 0.000 0.211
2.77 0.000 0.000 0.000 0.211
2.88 0.000 0.000 0.000 0.211
2.98 0.000 0.000 0.000 0.211
3.09 0.000 0.000 0.000 0.211
3.20 0.000 0.000 0.000 0.211
3.30 0.000 0.000 0.000 0.211
3.41 0.000 0.000 0.000 0.211
3.52 0.000 0.000 0.000 0.211
3.62 0.000 0.000 0.000 0.211
3.73 0.000 0.000 0.000 0.211
3.84 0.000 0.000 0.000 0.211
3.94 0.000 0.000 0.000 0.211
4.05 0.000 0.000 0.000 0.211
4.16 0.000 0.000 0.000 0.211
4.26 0.000 0.000 0.000 0.211
4.37 0.000 0.000 0.000 0.211
4.48 0.000 0.000 0.000 0.211
4.58 0.000 0.000 0.000 0.211
4.69 0.000 0.000 0.000 0.211
4.80 0.000 0.000 0.000 0.211
4.90 0.000 0.000 0.000 0.211
5.01 0.000 0.000 0.000 0.211
5.12 0.000 0.000 0.000 0.211
5.22 0.000 0.000 0.000 0.211
5.33 0.000 0.000 0.000 0.211

BASE MOMENTS (ULS) AND REINFORCEMENT TO ACI 318 - 2014

Position from Moment Top Reinforcing Bot Reinforcing Minimum


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

left (ft) (kipft) (in²/ft) (in²/ft) (in²/ft)

0.00 0.000 0.000 0.000 0.287


0.03 -0.001 0.000 0.000 0.287
0.06 -0.003 0.000 0.000 0.287
0.09 -0.006 0.000 0.000 0.287
0.12 -0.010 0.000 0.000 0.287
0.14 -0.016 0.000 0.001 0.287
0.17 -0.023 0.000 0.001 0.287
0.20 -0.031 0.000 0.001 0.287
0.23 -0.040 0.000 0.001 0.287
0.26 -0.051 0.000 0.002 0.287
0.29 -0.063 0.000 0.002 0.287
0.32 -0.076 0.000 0.003 0.287
0.35 -0.091 0.000 0.003 0.287
0.38 -0.107 0.000 0.004 0.287
0.40 -0.124 0.000 0.004 0.287
0.43 -0.142 0.000 0.005 0.287
0.46 -0.161 0.000 0.000 0.287
0.49 -0.182 0.000 0.000 0.287
0.52 -0.204 0.000 0.000 0.287
0.55 -0.228 0.000 0.000 0.287
0.58 -0.252 0.000 0.000 0.287
0.61 -0.278 0.000 0.000 0.287
0.63 -0.305 0.000 0.000 0.287
0.66 -0.334 0.000 0.000 0.287
0.69 -0.363 0.000 0.000 0.287
0.72 -0.394 0.000 0.000 0.287
0.75 -0.410 0.000 0.000 0.287
0.78 -0.636 0.000 0.000 0.287
0.81 -0.563 0.000 0.000 0.287
0.84 -0.517 0.000 0.000 0.287
0.87 -0.473 0.000 0.000 0.287
0.89 -0.431 0.000 0.000 0.287
0.92 -0.391 0.000 0.000 0.287
0.95 -0.353 0.000 0.000 0.287
0.98 -0.317 0.000 0.000 0.287
1.01 -0.283 0.000 0.000 0.287
1.04 -0.250 0.000 0.000 0.287
1.07 -0.220 0.008 0.000 0.287
1.10 -0.192 0.007 0.000 0.287
1.12 -0.165 0.006 0.000 0.287
1.15 -0.141 0.005 0.000 0.287
1.18 -0.118 0.004 0.000 0.287
1.21 -0.098 0.004 0.000 0.287
1.24 -0.079 0.003 0.000 0.287
1.27 -0.063 0.002 0.000 0.287
1.30 -0.048 0.002 0.000 0.287
1.33 -0.035 0.001 0.000 0.287
1.36 -0.024 0.001 0.000 0.287
1.38 -0.016 0.001 0.000 0.287
1.41 -0.009 0.000 0.000 0.287
1.44 -0.004 0.000 0.000 0.287
1.47 -0.001 0.000 0.000 0.287
1.50 0.000 0.000 0.000 0.287

SHEAR CHECK AT WALL-BASE JUNCTION TO ACI 318 - 2014

Shear force at bottom of wall V = 3.3 kip


Shear stress at bottom of wall v = 4.19 psi OK
Allowable shear stress vc = 112.08 psi (based on Wall tensile reinf.)
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Sketch of Wall

Design code: ACI 318 - 2014


0.330.95kip/ft
4.00kip
0.66
0.66
2.00

0.27
0.00°
16.00°

30.00°
6.00
2.00

0.42
0.66
0.42
0.67

Ka=0.30 (User defined)


Kp=3.00 (User defined)
µ=0.58 (User def.)
2.8psi V= 3.3kip
8.7psi v= 4.19psi
Wall type: Cantilever SFslip = 6.97 vc=112.08psi
Theory: Coulomb SFslip (ULS) = 5.00
SFovt = 7.44
SFovt (ULS) = 5.21
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Wall Bending Moments

Wall Moments

Moment max = .1628kipft @ -.670ft


5.00

4.50

4.00

3.50

3.00
Height (ft)

2.50

2.00

1.50

1.00

.500
.200

.400

.600

.800

1.00

1.20
Bending moment (kipft)

Base Bending Moments

Base Moments Moment max = -.6360kipft @ .754ft


.100

.200

.300

.400

.500

.600

.700

.800

.900

1.00

1.10

1.20

1.30

1.40

1.50

-.050
-.100
-.150
-.200
Bending moment (kipft)

-.250
-.300
-.350
-.400
-.450
-.500
-.550
-.600
-.650

Position (ft)
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST SLAB DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter E

Grade slab design

Page 84of 248


"GRDSLAB.xls" Program
Version 1.9

CONCRETE SLAB ON GRADE ANALYSIS


For Slab Subjected to Stationary Uniformly Distributed Live Loads

Job Name: BURNT STORE LAKES Subject:


Job Number: Originator: Checker:

Input Data:
*Aisle Width
Slab Thickness, t = 4.000 in. wLL wLL
Concrete Strength, f 'c = 5000 psi Top/Slab
Subgrade Modulus, k = 100 pci
Factor of Safety, FS = 2.000
t
Uniform Live Load, wLL = 200.00 psf

(Subgrade)

Concrete Slab on Grade with Uniform Loads

*Note: In an unjointed aisleway between uniformly distributed load areas,


negative bending moment in slab may be up to twice as great as
positive moment in slab beneath loaded area. Allowable uniform
load determined below is based on critical aisle width and as a
result, there are no restrictions on load layout configuration or
uniformity of loading.
Results:

Design Parameters:
Modulus of Rupture, MR = 636.40 psi MR = 9*SQRT(f 'c)
Allow. Bending Stress, Fb = 318.20 psi Fb = MR/FS
Modulus of Elasticity, Ec = 4030509 Ec = 57000*SQRT(f 'c)
Poisson's Ratio, m = 0.15 m = 0.15 (assumed for concrete)
Radius of Stiffness, Lr = 21.66 in. Lr = (Ec*t^3/(12*(1-m^2)*k))^0.25
Critical Aisle Width, Wcr = 3.99 ft. Wcr = (2.209*Lr)/12 (Ref. 3, Appendix 2 page 64)
(presented for information only)
Stationary Uniformly Distributed Live Loads:
Per Ref. #1: wLL(allow) = 817.44 psf wLL(allow) = 257.876*Fb*SQRT(k*t/Ec)
wLL(allow) >= wLL, O.K.

Per Ref. #2: wLL(allow) = 782.77 psf wLL(allow) = 0.123*Fb*SQRT(k*t)


wLL(allow) >= wLL, O.K.

Reference:
1. "Concrete Floor Slabs on Grade Subjected to Heavy Loads"
Army Technical Manual TM 5-809-12, Air Force Manual AFM 88-3, Chapter 15 (1987)
2. "Slab Thickness Design for Industrial Concrete Floors on Grade" (IS195.01D)
by Robert G. Packard (Portland Cement Association, 1976)
3. "Design of Slabs-on-Ground" - ACI 360R-06 - by American Concrete Institute

Comments:

1 of 1 24-04-2023 19:27

Page 85of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST BEAM / lLINTEL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter F

Precast Beam design

Page 86of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : PRECAST BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Beam design type markup,


* Precast beam design considered as Simply supported
* Precast beam design done with concise beam Software
Note: - *Without highlighted beam is checked but not included in the package and it will available upon request

Level -2 Beam layout:

Page 87of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Level-2 Precast beam Design: TYPE PB1

Material property data:


Grade of concrete = 6000 Psi
Grade of steel = 60 Ksi
Density of concrete = 0.15 Kip/ft³

Beam Geometry data:


Length of beam = 19 ft
Width of beam = 0.66 ft
Depth of beam = 2.16 ft
Thickness of screed = 0 ft
Beam support condtion = SSD

Beam Loading:
Self weight of beam = 0.66x2.16x0.150 = 0.214 Kip/ft

DESIGN LOADS:

Roof truss load on Beam:


Case - 1 - Gravity load check (Self weight + Roof truss dead load + Live load)
Case - 2 - Wind Suction load check (Self weight + Roof truss dead load + Wind load)
P1: Load from Roof:

Dead Load (Refer truss design) (U1 - Truss) = 1.41 Kip


(U2 - Truss) = 1.47 Kip
(U3 - Truss) = 1.61 Kip
(U4 - Truss) = 1.66 Kip
(U5 - Truss) = 1.61 Kip
(U6 - Truss) = 1.61 Kip
(U7 - Truss) = 1.61 Kip
(U8 - Truss) = 1.61 Kip

Live Load (Refer truss design) (U1 - Truss) = 1.3 Kip


(U2 - Truss) = 1.34 Kip
(U3 - Truss) = 1.43 Kip
(U4 - Truss) = 1.47 Kip
(U5 - Truss) = 1.47 Kip
(U6 - Truss) = 1.43 Kip
(U7 - Truss) = 1.43 Kip
(U8 - Truss) = 1.43 Kip

Total dead load on beam = 12.596 Kip 0.663 Kip/ft


Total live load on beam = 11.289 Kip 0.594 Kip/ft

Page 88of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

P2: Wind Suction load on Roof (upward):

Wind load (Refer truss design Detail) = -1.93 Klf

Loading Diagram:

Reinforcement design : Case - 1 Case - 2


Bottom Tension reinforcement at span
Required moment capacity,Mu (refer concise report) = 98 Kip-ft 105 Kip-ft
Provided Moment capacity,Mn (refer concise report) = 118 Kip-ft 136 Kip-ft

98 < 118 Hence safe

Shear reinforcementCalculation:
at Ends of Beam:
Required Shear capacity,Vs (refer concise report) = 17.00 Kip 16.00 Kip
Provided Shear capacity,Vn (refer concise report) = 57.00 Kip 45.00 Kip
Provided reinforcement As = #3 - 6 in = 0.44 in²/ft 0.44 in²/ft
(use Double ties)
17.00 < 57 Hence safe

At Interior of Beam:
Required Shear capacity,Vs (refer concise report) = 2.00 Kip 1.00 Kip
Provided Shear capacity,Vn (refer concise report) = 37.00 Kip 37.00 Kip
Provided reinforcement As = #3 - 12 in = 0.11 in²/ft 0.11 in²/ft

2 < 37 Hence safe

Provide #3 stirrups spacing @ 12" O.C

Page 89of 248


BSL - PB-001 Beam Design-Gravity Load.con
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con Page 90of 248 Fri Mar 31 16:47:53 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

SUMMARY REPORT

Design Code Used: ACI 318-14

________________________________________________________________________________________________________________________

NON-DEFAULT OPTION SETTINGS

** ON ** P1: Vary user defined losses along beam


** ON ** F1: Check minimum strength at critical sections only
** OFF ** F7: Reduce φ in the development length of strands (CSA A23.3 only)
** OFF ** F8: Use a rectangular stress block at concrete ultimate strain
** ON ** F10: Use the cracking moment for minimum flexural strength (ACI and NZ codes for non-prestressed bea
** ON ** S1: Use the simplified shear method if applicable
** ON ** S2: Take the best of the detailed and simplified method
** ON ** S5: Use Zia/Hsu Method for torsion as per PCI Standard Practice guide (ACI Codes Only)
** ON ** S8: Calculate pre-tensioned bursting steel requirements
** ON ** S10: Use the ultimate section capacity for horizontal shear (moment region check)
** OFF ** D3: Have Concise Beam calculate long-term deflection multipliers for prestressed Beams

________________________________________________________________________________________________________________________

CONCRETE MATERIAL PROPERTIES

Precast Beam
Concrete Density, Wt 150 lb/ft^3
Compressive Strength, f'c 6000.0 psi
Flexural Modulus of Rupture, fr 581 psi
Modulus of Elasticity, Ec 4.696E+6 psi

PRECAST CONCRETE MIX, SCHEDULE, AND SERVICE ENVIRONMENT


(schedule from time of casting precast beam at 0 days)

Cement Content 691 lb/yd^3 Age at Stripping 2.00 days


Air Content 5.00 % Age at Erection 40 days
Slump 1.97 in Age at Cast-in-Place Pour 50 days
Aggregate Mix 0.40 fines/total Age Cast-in-Place is Composite 53 days
Aggregate Size 0.79 in Age Construction is Complete 143 days
Basic Shrinkage Strain 0.000780 in/in
Curing Method Moist Relative Humidity in Service 70 %
Concrete Hydration Rate Normal Ambient Temperature in Service 20 deg
Exposure in Service Inter

________________________________________________________________________________________________________________________

PRECAST BEAM LAYOUT


____________________________________________________________________________________________________________________
|Seg.| Segment Length | Section Identification | Offset |
| No.| From | To | Length | Folder | Section | Section | Z | Y |
| | ft | ft | ft | Name | Name | Type | in | in |
____________________________________________________________________________________________________________________
| 1| 0.000| 19.000| 19.000| B1 | PB1- 2.16' depth | Solid Beam | 0.00| 0.00|
____________________________________________________________________________________________________________________

The cast-in-place pour, if defined, has been turned off (not included).

Span Length at Transfer = 19.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 19.000 ft
Span Length during Lift = 19.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 19.000 ft
Span Length in Service = 19.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 19.000 ft
Total Beam Length = 19.000 ft, Bearing Length, Left = 3.00 in, Right = 3.00 in

________________________________________________________________________________________________________________________

GROSS PRECAST SECTION PROPERTIES (NON-COMPOSITE)


(based on Ec of the precast beam - transformed area of rebar and strand NOT included)
____________________________________________________________________________________________________________
|Seg.| Section Properties | Section | Section | Shear | Volume /| Section Moduli |
| No.| A | I | yb | Height | Width | Width | Surface | Sb | St |
| | in^2 | in^4 | in | in | in | in | in | in^3 | in^3 |
____________________________________________________________________________________________________________
| 1| 208.0| 11717| 13.00| 26.00| 8.00| 8.00| 3.06| -901| 901|
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED SECTION PROPERTIES SUMMARY


____________________________________________________________________________________________________
| | Net Precast Section | Transformed Precast Section | Transformed Precast Section |
| | at Transfer (based on Eci) | at Transfer (based on Eci) | at 28 Days (based on Ec) |
| |(include rebar,deduct strand)| (include rebar and strand) | (include rebar and strand) |
| x | A | I | yb | A | I | yb | A | I | yb |
| ft | in^2 | in^4 | in | in^2 | in^4 | in | in^2 | in^4 | in |
____________________________________________________________________________________________________
| 0.000| 208.0| 11719| 13.00| 208.0| 11719| 13.00| 208.0| 11719| 13.00|
| 1.520| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 3.420| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 5.320| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 7.220| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 9.120| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 9.500| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 9.880| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 11.020| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 11.780| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 13.680| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 15.580| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 17.480| 227.1| 13494| 13.01| 227.1| 13494| 13.01| 222.0| 13015| 13.01|
| 19.000| 208.0| 11719| 13.00| 208.0| 11719| 13.00| 208.0| 11719| 13.00|
____________________________________________________________________________________________________
|These section properties can used to calculate uncracked concrete stresses using the following |
| guidelines. |
|- Net Precast Section at Transfer properties are used with the initial prestress after transfer |
| (after elastic shortening loss). |
|- Transformed Precast Section at Transfer properties are used with the precast beam self-weight. |
|- Transformed Precast Section at 28 Days properties are used with external loads applied to the |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con 1 of 6 248
Page 91of Fri Mar 31 18:22:08 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

| non-composite precast beam. |


____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LONGITUDINAL REINFORCING STEEL


________________________________________________________________________________________________________________________
|ID| Qty | Steel | Bar | | Bar |End Location & Type| Bar | | Cross |Vertical| Offset ** |
| | | Grade | Size | | Area | From | | To | | Spacing| | Spacing| Offset | Reference |
| | | ksi |C=coated| | in^2 | ft | *| ft | *| in | | in | in | |
________________________________________________________________________________________________________________________
| 1| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 2.00| Bottom of Precast Beam |
| 2| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 2.00| Top of Precast Beam |
| 3| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 4.00| Bottom of Precast Beam |
| 4| 2.000| 60.0| # 3 | | 0.220| 0.000|SE|19.000|SE| 4.00| | - | 14.00| Bottom of Precast Beam |
| 5| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 4.00| Top of Precast Beam |
________________________________________________________________________________________________________________________
|Some reinforcing groups are inactive. |
|* Straight Embeddment (SE), Fully Developed (FD), Standard Hook (SH), Headed Bar (HB) |
|** Offsets are measured up from the bottom or down from the top |
|See the "Development Length" text report for details of the bar and wire development lengths |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR STIRRUPS
_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 5.000| 60.0| *| # 3 | 2| 0.22| 6.00|
| 5.000| 14.000| 60.0| *| # 3 | 2| 0.22| 12.00|
| 14.000| 19.000| 60.0| *| # 3 | 2| 0.22| 6.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

INTERFACE SHEAR TIES


_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 5.000| 60.0| *| # 3 | 2| 0.22| 6.00|
| 5.000| 14.000| 60.0| *| # 3 | 2| 0.22| 12.00|
| 14.000| 19.000| 60.0| *| # 3 | 2| 0.22| 6.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

________________________________________________________________________________________________________________________

APPLIED LOADS
____________________________________________________________________________________________________________________________
| Load Group | Stages Applied | Load Details ** |
| & Type | & Distribution | (left to right) |
____________________________________________________________________________________________________________________________
|Beam Weight(1) |Stripping to Final Service |Segment #0: [V] 0.217 kip/ft full length |
| D: DL, Factory Produced |No Load Distribution | |
| | | |
|DL From Truss |Final Service stage only |Dead Load: [V] 0.661 kip/ft full length |
| D: DL, General |No Load Distribution | |
| | | |
|LL From Truss |Final Service stage only |Live Load: [V] 0.591 kip/ft full length |
| L: LL, General |No Load Distribution | |
| | | |
____________________________________________________________________________________________________________________________
|* indicates load groups generated automatically by Concise Beam. |
|** [V] Vertical Load, [M] Moment, [T] Torsion. |
____________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LOAD COMBINATIONS

Serviceability (SLS) & Fatigue (FLS) Limit State Combinations (used individually)
SLS Stress : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S + 1.00Ws + 0.60Wu
SLS Deflect : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S
FLS Fatigue : 1.00P + 1.00D + 1.00F + 1.00L + 1.00L1 + 1.00Lr

Ultimate (Strength) Limit State (ULS) Combinations (searched collectively to obtain envelope)
1: ULS Combo 1 : 1.40D + 1.40F
2: ULS Combo 2 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50Lr
3: ULS Combo 3 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50S
4: ULS Combo 4 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50R
5: ULS Combo 5 : 1.20D + 0.50L + 1.00L1 + 1.60Lr
6: ULS Combo 6 : 1.20D + 0.50L + 1.00L1 + 1.60S
7: ULS Combo 7 : 1.20D + 0.50L + 1.00L1 + 1.60R
8: ULS Combo 8 : 1.20D + 1.60Lr + 0.80Ws + 0.50Wu
9: ULS Combo 9 : 1.20D + 1.60S + 0.80Ws + 0.50Wu
10: ULS Combo 10 : 1.20D + 1.60R + 0.80Ws + 0.50Wu
11: ULS Combo 11 : 1.20D + 0.50L + 1.00L1 + 0.50Lr + 1.60Ws + 1.00Wu
12: ULS Combo 12 : 1.20D + 0.50L + 1.00L1 + 0.50S + 1.60Ws + 1.00Wu
13: ULS Combo 13 : 1.20D + 0.50L + 1.00L1 + 0.50R + 1.60Ws + 1.00Wu
14: ULS Combo 14 : 1.20D + 0.50L + 1.00L1 + 0.20S + 1.40Es + 1.00Eu
15: ULS Combo 15 : 0.90D + 1.60L + 1.60L1 + 0.50Lr
16: ULS Combo 16 : 0.90D + 1.60Ws + 1.00Wu
17: ULS Combo 17 : 0.90D + 0.90F + 1.40Es + 1.00Eu

________________________________________________________________________________________________________________________

COMBINED ANALYSIS IN SERVICE - LOAD COMBINATION RESULTS


(external loads only)
______________________________________________________________________________________________________________
| Station| SLS (stress) Load Combination | ULS Load Envelopes |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con 2 of 6 248
Page 92of Fri Mar 31 18:22:08 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

| | Moment | Moment | Shear | Moment |


| x | Sustained | Total Load | Total Load |Govern.| Total Load |Govern.|
| ft | kip.ft | kip.ft | kip | Combo.| kip.ft | Combo.|
| | | min | max | min | max |min|max| min | max |min|max|
______________________________________________________________________________________________________________
| 0.000| 0.00 | 0.00 | 0.00 | 7.50 | 18.99 | 16| 2| 0.00 | 0.00 | 1| 1|
| 1.520| 19.51 | 19.51 | 19.51 | 6.30 | 15.95 | 16| 2| 10.49 | 26.55 | 16| 2|
| 3.420| 39.13 | 39.13 | 39.13 | 4.80 | 12.15 | 16| 2| 21.04 | 53.25 | 16| 2|
| 5.320| 53.44 | 53.44 | 53.44 | 3.30 | 8.35 | 16| 2| 28.74 | 72.73 | 16| 2|
| 7.220| 62.46 | 62.46 | 62.46 | 1.80 | 4.56 | 16| 2| 33.59 | 85.00 | 16| 2|
| 9.120| 66.17 | 66.17 | 66.17 | 0.30 | 0.76 | 16| 2| 35.59 | 90.05 | 16| 2|
| 9.500| 66.27 | 66.27 | 66.27 | 0.00 | 0.00 | 1| 1| 35.64 | 90.20 | 16| 2|
| 9.880| 66.17 | 66.17 | 66.17 | -0.76 | -0.30 | 2| 16| 35.59 | 90.05 | 16| 2|
| 11.020| 64.58 | 64.58 | 64.58 | -3.04 | -1.20 | 2| 16| 34.73 | 87.89 | 16| 2|
| 11.780| 62.46 | 62.46 | 62.46 | -4.56 | -1.80 | 2| 16| 33.59 | 85.00 | 16| 2|
| 13.680| 53.44 | 53.44 | 53.44 | -8.35 | -3.30 | 2| 16| 28.74 | 72.73 | 16| 2|
| 15.580| 39.13 | 39.13 | 39.13 | -12.15 | -4.80 | 2| 16| 21.04 | 53.25 | 16| 2|
| 17.480| 19.51 | 19.51 | 19.51 | -15.95 | -6.30 | 2| 16| 10.49 | 26.55 | 16| 2|
| 19.000| 0.00 | 0.00 | 0.00 | -18.99 | -7.50 | 2| 16| 0.00 | 0.00 | 1| 1|
______________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SUPPORT REACTIONS DURING HANDLING


(+ve = upwards, counter-clockwise)
______________________________________________________________________
| | Initial Lifting | Erection Lifting |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical | Vertical |
| | kip | kip | kip | kip |
______________________________________________________________________
| Unfactored Load Group Effects |
|Beam Weight(1) | 2.06 | 2.06 | 2.06 | 2.06 |
| | | | | |
| Load Envelope Effects |
|SLS Minimum | 2.06 | 2.06 | 2.06 | 2.06 |
|SLS Maximum | 2.06 | 2.06 | 2.06 | 2.06 |
______________________________________________________________________

REACTIONS ON FINAL SUPPORTS


(+ve = upwards, counter-clockwise)
________________________________________________________________________________________________
| | During CIP Pour | In Service |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical[*]| Torsion[*] | Vertical[*]| Torsion[*] |
| | kip | kip | kip | kip.ft | kip | kip.ft |
________________________________________________________________________________________________
| Unfactored Load Group Effects |
|Beam Weight(1) | 2.06 | 2.06 | 2.06 | 0.00 | 2.06 | 0.00 |
|DL From Truss | | | 6.28 | 0.00 | 6.28 | 0.00 |
|LL From Truss | | | 5.61 | 0.00 | 5.61 | 0.00 |
| | | | | | | |
| Load Envelope Effects |
|SLS DL | | | 8.34 | 0.00 | 8.34 | 0.00 |
|SLS Sustain | | | 13.95 | 0.00 | 13.95 | 0.00 |
|SLS Minimum | 2.06 | 2.06 | 13.95 | 0.00 | 13.95 | 0.00 |
|SLS Maximum | 2.06 | 2.06 | 13.95 | 0.00 | 13.95 | 0.00 |
|ULS Minimum | | | 7.50 [16]| 0.00 [ 1]| 7.50 [16]| 0.00 [ 1]|
|ULS Maximum | | | 18.99 [ 2]| 0.00 [ 1]| 18.99 [ 2]| 0.00 [ 1]|
________________________________________________________________________________________________
|* Governing ULS Load Combination (below) |
________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED CONCRETE STRESS RESULTS


(+ve = compression, -ve = tension)
____________________________________________________________________________________________________________
| | x | Stress | Limit * | |
| Location | ft | psi | psi | |
____________________________________________________________________________________________________________
|STRESSES DURING INITIAL LIFTING | |
|Critical Compression | |
| Top of Beam | 9.500| 113| 2100| |
| Bottom of Beam | 0.000| 0| 2100| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -444| |
| Bottom of Beam | 9.500| -113| -444| |
____________________________________________________________________________________________________________
|STRESSES DURING ERECTION LIFTING | |
|Critical Compression | |
| Top of Beam | 9.500| 113| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| |
| Bottom of Beam | 9.500| -113| -581| |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE | |
|Critical Compression | |
| Top of Beam | 9.500| 794| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| Not cracked |
| Bottom of Beam | 9.500| -795| -581| Check crack control requirements below |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE (SUSTAINED LOADS ONLY) | |
|Critical Compression | |
| Top of Beam | 9.500| 794| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
____________________________________________________________________________________________________________
|* Tensile stress limit shown for the precast beam is the flexural cracking strength for comparison only. |
| Crack control is required. |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con 3 of 6 248
Page 93of Fri Mar 31 18:22:08 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

|* Compression limit shown is 0.6 times the compressive strength for comparison only. |
|** See the detailed Uncracked Stress reports for full extent of tensile reinforcing required to control |
| cracking during transfer and handling. |
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

CRACK CONTROL STEEL AND SPACING


(+ve = compression, -ve = tension)
___________________________________________________________________________________________________________________________
| | Bottom | Top of | |
| | of Beam | Beam | |
___________________________________________________________________________________________________________________________
| kb | 1.00| 0.00| | Adjustment coefficient for prestressing steel |
| cc | 1.69| 0.00|in | Clear concrete cover to steel closest to tension face |
| fs | -31.2| 0.0|ksi | Steel stress nearest to tension face after decompression |
| Max spacing | 15.03| 0.00|in | Maximum centre/centre spacing of steel closest to tension face |
___________________________________________________________________________________________________________________________

CRACK WIDTH ESTIMATE


___________________________________________________________________________________________________________________________
| | Bottom | Top of | |
| | of Beam | Beam | |
___________________________________________________________________________________________________________________________
| Cracked? | Yes | No | | |
| Cracking at | 9.500| 0.000|ft | Location of maximum crack width from left end of beam |
| Ms | 66.27| 0.00|kip.ft | External service moment (DL + LL) |
| Pdc | 0.00| 0.00|kip | Prestress force at cracked centroid |
| Mint | 66.27| 0.00|kip.ft | Internal moment about cracked centroid |
| c | 5.60| 0.00|in | Concrete depth in compression |
| Steel type | Rebar| Rebar| | Type of steel in tension |
| Method |Gergely-Lutz|Gergely-Lutz| | Crack width estimate equation used * |
| k1 | 75.842E-6 | 0.00 |in^2/Kip| Coefficient dependent on steel type |
| h2/h1 | 1.11| 0.00| | Ratio of depth in tension to depth of steel from NA |
| Act | 74.5| 0.0|in^2 | Area of concrete in tension around crack control steel |
| dc | 2.00| 0.00|in | Concrete cover to center of steel at tension face |
| A | 15.8| 0.0|in^2 | Area of concrete in tension around each bar |
| fs | -31.2| 0.0|ksi | Steel stress nearest tension face |
| | | | | |
|Est Crack Width| 0.008| 0.000|in | Estimated maximum crack width |
| | | | | |
| fc | 1535| 0|psi | Maximum concrete compressive stress |
| limit | 3600| 3600|psi | Allowable concrete compressive stress for prestressed concrete |
___________________________________________________________________________________________________________________________
|Crack width estimates are only approximations based on idealized behaviour and average crack spacing. These estimates |
| only represent a level of cracking and should only be used in comparison with appropriate limits such as those given |
| below. It would not be appropriate to compare these estimates to measured crack widths. |
| |
|* Gergely & Lutz equation: w = k1 x fs x h2 / h1 x CubicRoot(dc * A) |
___________________________________________________________________________________________________________________________

Recommended Maximum Crack Width (in)


(from PCI Design Handbook, 5th edition)
____________________________________________________________________
| | Critical | Prestressed | Reinforced |
| | Appearance | Concrete | Concrete |
____________________________________________________________________
| Exterior Exposure| 0.007| 0.010| 0.013|
| Interior Exposure| 0.010| 0.012| 0.016|
____________________________________________________________________

________________________________________________________________________________________________________________________

DEFLECTION ESTIMATE AT ALL STAGES


_____________________________________________________________________________________________________________
| | Net Deflection | Change in Deflection| Span/Deflection Ratio |
|Location| Net @ | Net @ | Net Sust.| Net Total| Sustained| LL | Net Total| Sustained| LL |
| x | Erection |Completion| @ Final | @ Final | Growth+LL| alone |Deflection| Growth+LL| alone |
| ft | in | in | in | in | in | in | | | |
| Column | B | C | D | E | E - C | E - D | L/E * | L/(E-C) *| L/(E-D) |
_____________________________________________________________________________________________________________
| 0.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
| 1.520| -0.004 | -0.005 | -0.066 | -0.066 | -0.061 | 0.000 | 3435 | 3710 | 0 |
| 3.420| -0.008 | -0.011 | -0.145 | -0.145 | -0.134 | 0.000 | 1576 | 1701 | 0 |
| 5.320| -0.011 | -0.015 | -0.213 | -0.213 | -0.198 | 0.000 | 1071 | 1153 | 0 |
| 7.220| -0.013 | -0.018 | -0.263 | -0.263 | -0.245 | 0.000 | 866 | 930 | 0 |
| 9.120| -0.014 | -0.019 | -0.285 | -0.285 | -0.266 | 0.000 | 798 | 857 | 0 |
| 9.500| -0.014 | -0.019 | -0.286 | -0.286 | -0.267 | 0.000 | 796 | 855 | 0 |
| 9.880| -0.014 | -0.019 | -0.285 | -0.285 | -0.266 | 0.000 | 798 | 857 | 0 |
| 11.020| -0.014 | -0.019 | -0.276 | -0.276 | -0.257 | 0.000 | 826 | 887 | 0 |
| 11.780| -0.013 | -0.018 | -0.263 | -0.263 | -0.245 | 0.000 | 866 | 930 | 0 |
| 13.680| -0.011 | -0.015 | -0.213 | -0.213 | -0.198 | 0.000 | 1071 | 1153 | 0 |
| 15.580| -0.008 | -0.011 | -0.145 | -0.145 | -0.134 | 0.000 | 1576 | 1701 | 0 |
| 17.480| -0.004 | -0.005 | -0.066 | -0.066 | -0.061 | 0.000 | 3435 | 3710 | 0 |
| 19.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
_____________________________________________________________________________________________________________
| Col. B |Net deflection at erection includes all dead loads applied before the cast-in-place pour plus |
| | long-time deflection growth of the beam weight up to erection. |
| Col. C |Net deflection at completion of construction includes all dead loads plus long-time deflection |
| | growth of the dead load up to completion. |
| Col. D |Net sustained deflection at final includes all dead loads, and sustained live loads, plus |
| | long-time deflection growth. |
| Col. E |Net total deflection at final includes all dead loads, and all live loads, plus long-time |
| | deflection growth. |
| Note |Sustained deflection or growth includes dead loads and sustained live loads. |
| * |Span/deflection ratio is maximized with or without the inclusion of live load. |
_____________________________________________________________________________________________________________

Span/Deflection Limits: Sustained Load Growth + LL = L / 480 for non-structural attachments


Sustained Load Growth + LL = L / 240 otherwise
LL alone = L / 360 for floors *
LL alone = L / 180 for roofs *
* See the Vibration Check in Service report for more specific vibration guidelines

________________________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con 4 of 6 248
Page 94of Fri Mar 31 18:22:08 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

UNRESTRAINED SUPPORT ROTATIONS AT ALL STAGES


(+ve = clockwise rotation)
________________________________________________________________________________________
| | Net Rotation | Change in Rotation |
| Support| Net @ | Net @ | Net DL | Net Total | DL growth | LL |
|Location| Erection | Completion | @ Final | @ Final | + LL | alone |
| | degrees | degrees | degrees | degrees | degrees | degrees |
| Column | B | C | D | E | E - C | E - D |
________________________________________________________________________________________
| Left| 0.0116 | 0.0157 | 0.2103 | 0.2103 | 0.1946 | 0.0000 |
| Right| -0.0116 | -0.0157 | -0.2103 | -0.2103 | -0.1946 | 0.0000 |
________________________________________________________________________________________

UNRESTRAINED LONGITUDINAL CHANGE OF LENGTH DUE TO CREEP AND SHRINKAGE


(-ve = shortening, +ve = elongation)
__________________________________________________________________________________________________
| | Total Change of Length | Difference in Change |
| | Erection | Composite|Completion| Final | | to Compl.| to Final | to Final |
| | in | in | in | in | | in | in | in |
| | B | | C | D | | C - B | D - C | D - B |
__________________________________________________________________________________________________
| Creep| 0.0000| 0.0000| 0.0000| 0.0000| | 0.0000| 0.0000| 0.0000|
| Shrink.| -0.0412| -0.0476| -0.0706| -0.1071| | -0.0294| -0.0365| -0.0659|
| Total| -0.0412| -0.0476| -0.0706| -0.1071| | -0.0294| -0.0365| -0.0659|
__________________________________________________________________________________________________

Elastic Shortening = 0.0000 in

________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

FLEXURAL DESIGN CHECK IN FINAL SERVICE


________________________________________________________________________________________________________________________
| | Design | Cracking | Minimum * | Design | Depth in | Net Tensile| Flexural | Ø | Warnings |
| | Moment | Moment | Flexural | Strength | Compression| Strain |Classication| | & Notes |
| x | Mu | Mcr | Strength | ØMn | c | | | | |
| ft | kip.ft | kip.ft | kip.ft | kip.ft | in | | | | |
________________________________________________________________________________________________________________________
| 0.000| 0.00| 43.64| 0.00| 0.11| 5.55| 0.0000| Tension | 0.90| 3 |
| 1.520| 26.55| 48.45| 35.40| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 3.420| 53.25| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 5.320| 72.73| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 7.220| 85.00| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 9.120| 90.05| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 9.500| 90.20| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 9.880| 90.05| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 11.020| 87.89| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 11.780| 85.00| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 13.680| 72.73| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 15.580| 53.25| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 17.480| 26.55| 48.45| 35.40| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 19.000| 0.00| 43.64| 0.00| 0.11| 5.55| 0.0000| Tension | 0.90| 3 |
| |
________________________________________________________________________________________________________________________
|Points of Maximum and Minimum Factored Moment |
| 9.500| 90.20| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 0.000| 0.00| 43.64| 0.00| -0.12| 5.59| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Factored Moment to Design Strength |
| 9.500| 90.20| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 0.000| 0.00| 43.64| 0.00| -0.12| 5.59| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Minimum Strength to Design Strength |
| 2.850| 46.00| 48.45| 58.14| 135.73| 2.92| 0.0216| Tension | 0.90| |
| 0.000| 0.00| 43.64| 0.00| -0.12| 5.59| 0.0000| Tension | 0.90| 3 |
________________________________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design strength is based on a reduced maximum concrete strain to avoid steel slippage or rupture. See |
| | Flexural Design Detail Report and Help file's Technical Background for more information. |
| * |Minimum Flexural Strength is 1.2 Mcr or 4/3 Mu [ACI 318-14::9.6/Option F10] |
|ØMn(As,min) is the factored flexural strength based on the minimum required area for tensile steel required by the |
| selected code. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods (Option G3). |
|See the Flexural Design Details text report for more details. |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR DESIGN CHECK IN FINAL SERVICE


_____________________________________________________________________________________________________
| | Design | Vertical | Concrete | Required | Strength Provided | Warnings |
| | Shear | Prestress| Strength | Stirrups | Stirrups | Total | & Notes |
| x | Vu | Vp | ØVc | ØVs | ØVs | ØVn | |
| ft | kip | kip | kip | kip | kip | kip | |
_____________________________________________________________________________________________________
| 0.000| 14.90| 0.00| 21.43| 8.04| 38.04| 59.48| 1 3 5 |
| 1.520| 14.90| 0.00| 22.63| 8.02| 37.95| 60.58| 1 3 |
| 3.420| 12.15| 0.00| 21.38| 8.02| 37.95| 59.33| 1 5 |
| 5.320| 8.35| 0.00| 21.38| 0.00| 18.98| 40.35| 5 |
| 7.220| 4.56| 0.00| 21.38| 0.00| 18.98| 40.35| 5 |
| 9.120| 0.76| 0.00| 21.38| 0.00| 18.98| 40.35| 5 |
| 9.500| 0.00| 0.00| 21.38| 0.00| 18.98| 40.35| 5 |
| 9.500| 0.00| 0.00| -21.38| 0.00| -18.98| -40.35| 5 |
| 9.880| -0.76| 0.00| -21.38| 0.00| -18.98| -40.35| 5 |
| 11.020| -3.04| 0.00| -21.38| 0.00| -18.98| -40.35| 5 |
| 11.780| -4.56| 0.00| -21.38| 0.00| -18.98| -40.35| 5 |
| 13.680| -8.35| 0.00| -21.38| 0.00| -18.98| -40.35| 5 |
| 15.580| -12.15| 0.00| -21.38| -8.02| -37.95| -59.33| 1 5 |
| 17.480| -14.90| 0.00| -22.63| -8.02| -37.95| -60.58| 1 3 |
| 19.000| -14.90| 0.00| -21.43| -8.04| -38.04| -59.48| 1 3 5 |
_____________________________________________________________________________________________________
|Warnings & Notes |
|Note [1]|Transverse shear steel is required. See the Shear Transvese Reinforcing Design Check |
| | report. |
|Note [3]|Design shear force at critical section near support used [ACI 318-14::7.4.3.2/9.4.3.2]. |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con 5 of 6 248
Page 95of Fri Mar 31 18:22:08 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

|Note [5]|Calculation of the shear strength of the concrete used the simplified method [ACI |
| | 318-14::22.5.5.1/22.5.8.2]. |
| Note |The PCI recommended Zia/Hsu method was used to calculate the above shear design check |
| | results [PCI Handbbok 8th ed. section 5.4.1]. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods |
| | (Option G3). |
|See the Shear Design Check Details text report for more details. |
_____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR TRANSVERSE REINFORCING DESIGN CHECK IN FINAL SERVICE


_________________________________________________________________________________________________
| |Shear Steel|Shear Steel|Shear Steel| Stirrup | Stirrup Spacing | Warnings |
| | Grade | Required | Provided | Provided | Provided | Max. Allow| & Notes |
| x | fy | Av/s | Av/s | Av | s | s | |
| ft | ksi | in^2/ft | in^2/ft | in^2 | in | in | |
_________________________________________________________________________________________________
| 0.000| 60.0| 0.093| 0.440| 0.220| 6.00| 11.53| 1 4 5 |
| 1.520| 60.0| 0.093| 0.440| 0.220| 6.00| 11.50| 1 4 5 |
| 3.420| 60.0| 0.093| 0.440| 0.220| 6.00| 11.50| 1 5 |
| 5.320| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 7.220| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.120| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.500| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.500| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.880| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 11.020| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 11.780| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 13.680| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 15.580| 60.0| 0.093| 0.440| 0.220| 6.00| 11.50| 1 5 |
| 17.480| 60.0| 0.093| 0.440| 0.220| 6.00| 11.50| 1 4 5 |
| 19.000| 60.0| 0.093| 0.440| 0.220| 6.00| 11.53| 1 4 5 |
_________________________________________________________________________________________________
|Warnings & Notes |
|Note [1]|Amount of shear steel required represents minimum code requirements [ACI |
| | 318-14::9.6.3.3]. |
|Note [4]|Design shear force at critical section near support used [ACI |
| | 318-14::7.4.3.2/9.4.3.2]. |
|Note [5]|Required stirrup spacing represents maximum code requirements [ACI 318-14::9.7.6.2.2].|
| Note |Shear steel requirements for pre-tension bursting have been included (calculation |
| | option S8). |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical |
| | methods (calculation option G3). |
| * |Portion of the total stirrup area required to resist torsional shear flow (one leg |
| | around periphery). |
| ** |Allowable reduction within flexural compression zone [ACI 318-14::9.5.4.5]. Limited to|
| | half the Total and Al minimum. |
|See the Shear Design Check Details text report for more details. |
_________________________________________________________________________________________________

________________________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con 6 of 6 248
Page 96of Fri Mar 31 18:22:08 2023
Flexure Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

Flexure Check - Final Service


(ACI 318-14)
160

140

120

100
Moment - kip.ft

80

60

40

20

-20

-40

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Design Moment, Mu: +ve Bending
Min. Strength Required: +ve Bending
Design Strength, ØMn: +ve Bending

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con Page 97of 248 Fri Mar 31 18:22:18 2023
Shear Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

Shear Check - Final Service


(ACI 318-14)
100

80

60

40

20
Shear - kip

-20

-40

-60

-80

-100

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Design Shear, Vu
Total Strength Provided, ØVn
Concrete Strength Provided, ØVc
Critical Section for Shear Loading

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con Page 98of 248 Fri Mar 31 18:22:27 2023
Deflection - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

Deflection - Final Service


(ACI 318-14)
0.100

0.050

0.000

-0.050
Deflection - in

-0.100

-0.150

-0.200

-0.250

-0.300

-0.350

-0.400

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Deflection @ Erection
Deflection On Completion
Final Service Sustained Deflection
Final Service Sust. + LL Deflection

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con Page 99of 248 Fri Mar 31 18:22:36 2023
Deflection Limits - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

Deflection Limits - Final Service


(ACI 318-14)
2.000

1.600

1.200

0.800
Deflection - in

0.400

0.000

-0.400

-0.800

-1.200

-1.600

-2.000

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Sustained Load Growth + Live Load
Sust.+LL Maximum Limit (L/240)
Sust.+LL Non-Structural Limit (L/480)
Live Load Only
LL Limit for Roofs (L/180)
LL Limit for Floors (L/360)

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con Page 100of 248 Fri Mar 31 18:22:44 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

Concrete Stress (beam) - Final Service


(ACI 318-14)
4900

4200

3500
Stress (compression +ve) - psi

2800

2100

1400

700

-700

-1400

-2100

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con Page 101of 248 Fri Mar 31 18:22:57 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB-004 -Gravity

Concrete Stress (Sust) - Final Service


(ACI 318-14)
4900

4200

3500
Stress (compression +ve) - psi

2800

2100

1400

700

-700

-1400

-2100

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-Gravity Load.con Page 102of 248 Fri Mar 31 18:23:05 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

SUMMARY REPORT

Design Code Used: ACI 318-14

________________________________________________________________________________________________________________________

NON-DEFAULT OPTION SETTINGS

** ON ** P1: Vary user defined losses along beam


** ON ** F1: Check minimum strength at critical sections only
** OFF ** F7: Reduce φ in the development length of strands (CSA A23.3 only)
** OFF ** F8: Use a rectangular stress block at concrete ultimate strain
** ON ** F10: Use the cracking moment for minimum flexural strength (ACI and NZ codes for non-prestressed bea
** ON ** S1: Use the simplified shear method if applicable
** ON ** S2: Take the best of the detailed and simplified method
** ON ** S5: Use Zia/Hsu Method for torsion as per PCI Standard Practice guide (ACI Codes Only)
** ON ** S8: Calculate pre-tensioned bursting steel requirements
** ON ** S10: Use the ultimate section capacity for horizontal shear (moment region check)
** OFF ** D3: Have Concise Beam calculate long-term deflection multipliers for prestressed Beams

________________________________________________________________________________________________________________________

CONCRETE MATERIAL PROPERTIES

Precast Beam
Concrete Density, Wt 150 lb/ft^3
Compressive Strength, f'c 6000.0 psi
Flexural Modulus of Rupture, fr 581 psi
Modulus of Elasticity, Ec 4.696E+6 psi

PRECAST CONCRETE MIX, SCHEDULE, AND SERVICE ENVIRONMENT


(schedule from time of casting precast beam at 0 days)

Cement Content 691 lb/yd^3 Age at Stripping 2.00 days


Air Content 5.00 % Age at Erection 40 days
Slump 1.97 in Age at Cast-in-Place Pour 50 days
Aggregate Mix 0.40 fines/total Age Cast-in-Place is Composite 53 days
Aggregate Size 0.79 in Age Construction is Complete 143 days
Basic Shrinkage Strain 0.000780 in/in
Curing Method Moist Relative Humidity in Service 70 %
Concrete Hydration Rate Normal Ambient Temperature in Service 20 deg
Exposure in Service Inter

________________________________________________________________________________________________________________________

PRECAST BEAM LAYOUT


____________________________________________________________________________________________________________________
|Seg.| Segment Length | Section Identification | Offset |
| No.| From | To | Length | Folder | Section | Section | Z | Y |
| | ft | ft | ft | Name | Name | Type | in | in |
____________________________________________________________________________________________________________________
| 1| 0.000| 19.000| 19.000| B1 | PB1- 2.16' depth | Solid Beam | 0.00| 0.00|
____________________________________________________________________________________________________________________

The cast-in-place pour, if defined, has been turned off (not included).

Span Length at Transfer = 19.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 19.000 ft
Span Length during Lift = 19.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 19.000 ft
Span Length in Service = 19.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 19.000 ft
Total Beam Length = 19.000 ft, Bearing Length, Left = 3.00 in, Right = 3.00 in

________________________________________________________________________________________________________________________

GROSS PRECAST SECTION PROPERTIES (NON-COMPOSITE)


(based on Ec of the precast beam - transformed area of rebar and strand NOT included)
____________________________________________________________________________________________________________
|Seg.| Section Properties | Section | Section | Shear | Volume /| Section Moduli |
| No.| A | I | yb | Height | Width | Width | Surface | Sb | St |
| | in^2 | in^4 | in | in | in | in | in | in^3 | in^3 |
____________________________________________________________________________________________________________
| 1| 208.0| 11717| 13.00| 26.00| 8.00| 8.00| 3.06| -901| 901|
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED SECTION PROPERTIES SUMMARY


____________________________________________________________________________________________________
| | Net Precast Section | Transformed Precast Section | Transformed Precast Section |
| | at Transfer (based on Eci) | at Transfer (based on Eci) | at 28 Days (based on Ec) |
| |(include rebar,deduct strand)| (include rebar and strand) | (include rebar and strand) |
| x | A | I | yb | A | I | yb | A | I | yb |
| ft | in^2 | in^4 | in | in^2 | in^4 | in | in^2 | in^4 | in |
____________________________________________________________________________________________________
| 0.000| 208.0| 11719| 13.00| 208.0| 11719| 13.00| 208.0| 11719| 13.00|
| 1.520| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 3.420| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 5.320| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 7.220| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 9.120| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 9.500| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 9.880| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 11.020| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 11.780| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 13.680| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 15.580| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 17.480| 227.1| 13492| 13.00| 227.1| 13492| 13.00| 222.0| 13014| 13.00|
| 19.000| 208.0| 11719| 13.00| 208.0| 11719| 13.00| 208.0| 11719| 13.00|
____________________________________________________________________________________________________
|These section properties can used to calculate uncracked concrete stresses using the following |
| guidelines. |
|- Net Precast Section at Transfer properties are used with the initial prestress after transfer |
| (after elastic shortening loss). |
|- Transformed Precast Section at Transfer properties are used with the precast beam self-weight. |
|- Transformed Precast Section at 28 Days properties are used with external loads applied to the |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con 1 of 6 248
Page 103of Fri Mar 31 16:56:48 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

| non-composite precast beam. |


____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LONGITUDINAL REINFORCING STEEL


________________________________________________________________________________________________________________________
|ID| Qty | Steel | Bar | | Bar |End Location & Type| Bar | | Cross |Vertical| Offset ** |
| | | Grade | Size | | Area | From | | To | | Spacing| | Spacing| Offset | Reference |
| | | ksi |C=coated| | in^2 | ft | *| ft | *| in | | in | in | |
________________________________________________________________________________________________________________________
| 1| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 2.00| Bottom of Precast Beam |
| 2| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 2.00| Top of Precast Beam |
| 3| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 4.00| Bottom of Precast Beam |
| 4| 2.000| 60.0| # 5 | | 0.620| 0.000|SE|19.000|SE| 4.00| | - | 4.00| Top of Precast Beam |
| 5| 2.000| 60.0| # 3 | | 0.220| 0.000|SE|19.000|SE| 4.00| | - | 13.00| Bottom of Precast Beam |
________________________________________________________________________________________________________________________
|* Straight Embeddment (SE), Fully Developed (FD), Standard Hook (SH), Headed Bar (HB) |
|** Offsets are measured up from the bottom or down from the top |
|See the "Development Length" text report for details of the bar and wire development lengths |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR STIRRUPS
_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 5.000| 60.0| *| # 3 | 2| 0.22| 6.00|
| 5.000| 14.000| 60.0| *| # 3 | 2| 0.22| 12.00|
| 14.000| 19.000| 60.0| *| # 3 | 2| 0.22| 6.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

INTERFACE SHEAR TIES


_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 5.000| 60.0| *| # 3 | 2| 0.22| 6.00|
| 5.000| 14.000| 60.0| *| # 3 | 2| 0.22| 12.00|
| 14.000| 19.000| 60.0| *| # 3 | 2| 0.22| 6.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

________________________________________________________________________________________________________________________

APPLIED LOADS
____________________________________________________________________________________________________________________________
| Load Group | Stages Applied | Load Details ** |
| & Type | & Distribution | (left to right) |
____________________________________________________________________________________________________________________________
|Beam Weight(1) |Erection to Final Service |Segment #0: [V] 0.217 kip/ft full length |
| D: DL, Factory Produced |No Load Distribution | |
| | | |
|DL From Truss |Final Service stage only |Dead Load: [V] 0.661 kip/ft full length |
| D: DL, General |No Load Distribution | |
| | | |
|WL From Truss |Final Service stage only |Wind Load: [V] -1.927 kip/ft full length |
| Ws: Wind on Traffic (SLS) |No Load Distribution | |
| | | |
____________________________________________________________________________________________________________________________
|* indicates load groups generated automatically by Concise Beam. |
|** [V] Vertical Load, [M] Moment, [T] Torsion. |
____________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LOAD COMBINATIONS

Serviceability (SLS) & Fatigue (FLS) Limit State Combinations (used individually)
SLS Stress : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S + 1.00Ws + 0.60Wu
SLS Deflect : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S
FLS Fatigue : 1.00P + 1.00D + 1.00F + 1.00L + 1.00L1 + 1.00Lr

Ultimate (Strength) Limit State (ULS) Combinations (searched collectively to obtain envelope)
1: ULS Combo 1 : 1.40D + 1.40F
2: ULS Combo 2 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50Lr
3: ULS Combo 3 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50S
4: ULS Combo 4 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50R
5: ULS Combo 5 : 1.20D + 0.50L + 1.00L1 + 1.60Lr
6: ULS Combo 6 : 1.20D + 0.50L + 1.00L1 + 1.60S
7: ULS Combo 7 : 1.20D + 0.50L + 1.00L1 + 1.60R
8: ULS Combo 8 : 1.20D + 1.60Lr + 0.80Ws + 0.50Wu
9: ULS Combo 9 : 1.20D + 1.60S + 0.80Ws + 0.50Wu
10: ULS Combo 10 : 1.20D + 1.60R + 0.80Ws + 0.50Wu
11: ULS Combo 11 : 1.20D + 0.50L + 1.00L1 + 0.50Lr + 1.60Ws + 1.00Wu
12: ULS Combo 12 : 1.20D + 0.50L + 1.00L1 + 0.50S + 1.60Ws + 1.00Wu
13: ULS Combo 13 : 1.20D + 0.50L + 1.00L1 + 0.50R + 1.60Ws + 1.00Wu
14: ULS Combo 14 : 1.20D + 0.50L + 1.00L1 + 0.20S + 1.40Es + 1.00Eu
15: ULS Combo 15 : 0.90D + 1.60L + 1.60L1 + 0.50Lr
16: ULS Combo 16 : 0.90D + 1.60Ws + 1.00Wu
17: ULS Combo 17 : 0.90D + 0.90F + 1.40Es + 1.00Eu

________________________________________________________________________________________________________________________

COMBINED ANALYSIS IN SERVICE - LOAD COMBINATION RESULTS


(external loads only)
______________________________________________________________________________________________________________
| Station| SLS (stress) Load Combination | ULS Load Envelopes |
| | Moment | Moment | Shear | Moment |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con 2 of 6 248
Page 104of Fri Mar 31 16:56:48 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

| x | Sustained | Total Load | Total Load |Govern.| Total Load |Govern.|


| ft | kip.ft | kip.ft | kip | Combo.| kip.ft | Combo.|
| | | min | max | min | max |min|max| min | max |min|max|
______________________________________________________________________________________________________________
| 0.000| 0.00 | 0.00 | 0.00 | -21.79 | 11.67 | 16| 1| 0.00 | 0.00 | 1| 1|
| 1.520| -13.94 | -13.94 | -13.94 | -18.30 | 9.81 | 16| 1| -30.47 | 16.32 | 16| 1|
| 3.420| -27.96 | -27.96 | -27.96 | -13.94 | 7.47 | 16| 1| -61.10 | 32.74 | 16| 1|
| 5.320| -38.18 | -38.18 | -38.18 | -9.59 | 5.14 | 16| 1| -83.45 | 44.71 | 16| 1|
| 7.220| -44.62 | -44.62 | -44.62 | -5.23 | 2.80 | 16| 1| -97.52 | 52.25 | 16| 1|
| 9.120| -47.28 | -47.28 | -47.28 | -0.87 | 0.47 | 16| 1| -103.32 | 55.36 | 16| 1|
| 9.500| -47.35 | -47.35 | -47.35 | 0.00 | 0.00 | 1| 1| -103.49 | 55.45 | 16| 1|
| 9.880| -47.28 | -47.28 | -47.28 | -0.47 | 0.87 | 1| 16| -103.32 | 55.36 | 16| 1|
| 11.020| -46.14 | -46.14 | -46.14 | -1.87 | 3.49 | 1| 16| -100.84 | 54.03 | 16| 1|
| 11.780| -44.62 | -44.62 | -44.62 | -2.80 | 5.23 | 1| 16| -97.52 | 52.25 | 16| 1|
| 13.680| -38.18 | -38.18 | -38.18 | -5.14 | 9.59 | 1| 16| -83.45 | 44.71 | 16| 1|
| 15.580| -27.96 | -27.96 | -27.96 | -7.47 | 13.94 | 1| 16| -61.10 | 32.74 | 16| 1|
| 17.480| -13.94 | -13.94 | -13.94 | -9.81 | 18.30 | 1| 16| -30.47 | 16.32 | 16| 1|
| 19.000| 0.00 | 0.00 | 0.00 | -11.67 | 21.79 | 1| 16| 0.00 | 0.00 | 1| 1|
______________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SUPPORT REACTIONS DURING HANDLING


(+ve = upwards, counter-clockwise)
______________________________________________________________________
| | Initial Lifting | Erection Lifting |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical | Vertical |
| | kip | kip | kip | kip |
______________________________________________________________________
| Unfactored Load Group Effects |
| | | | | |
| Load Envelope Effects |
|SLS Minimum | 0.00 | 0.00 | 0.00 | 0.00 |
|SLS Maximum | 0.00 | 0.00 | 0.00 | 0.00 |
______________________________________________________________________

REACTIONS ON FINAL SUPPORTS


(+ve = upwards, counter-clockwise)
________________________________________________________________________________________________
| | During CIP Pour | In Service |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical[*]| Torsion[*] | Vertical[*]| Torsion[*] |
| | kip | kip | kip | kip.ft | kip | kip.ft |
________________________________________________________________________________________________
| Unfactored Load Group Effects |
|Beam Weight(1) | 2.06 | 2.06 | 2.06 | 0.00 | 2.06 | 0.00 |
|DL From Truss | | | 6.28 | 0.00 | 6.28 | 0.00 |
|WL From Truss | | | -18.31 | 0.00 | -18.31 | 0.00 |
| | | | | | | |
| Load Envelope Effects |
|SLS DL | | | 8.34 | 0.00 | 8.34 | 0.00 |
|SLS Sustain | | | -9.97 | 0.00 | -9.97 | 0.00 |
|SLS Minimum | 2.06 | 2.06 | -9.97 | 0.00 | -9.97 | 0.00 |
|SLS Maximum | 2.06 | 2.06 | -9.97 | 0.00 | -9.97 | 0.00 |
|ULS Minimum | | | -21.79 [16]| 0.00 [ 1]| -21.79 [16]| 0.00 [ 1]|
|ULS Maximum | | | 11.67 [ 1]| 0.00 [ 1]| 11.67 [ 1]| 0.00 [ 1]|
________________________________________________________________________________________________
|* Governing ULS Load Combination (below) |
________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED CONCRETE STRESS RESULTS


(+ve = compression, -ve = tension)
____________________________________________________________________________________________________________
| | x | Stress | Limit * | |
| Location | ft | psi | psi | |
____________________________________________________________________________________________________________
|STRESSES DURING INITIAL LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 2100| |
| Bottom of Beam | 0.000| 0| 2100| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -444| |
| Bottom of Beam | 0.000| 0| -444| |
____________________________________________________________________________________________________________
|STRESSES DURING ERECTION LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| |
| Bottom of Beam | 0.000| 0| -581| |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 3600| |
| Bottom of Beam | 9.500| 568| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 9.500| -568| -581| Not cracked |
| Bottom of Beam | 0.000| 0| -581| Not cracked |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE (SUSTAINED LOADS ONLY) | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 3600| |
| Bottom of Beam | 9.500| 568| 3600| |
____________________________________________________________________________________________________________
|* Tensile stress limit shown for the precast beam is the flexural cracking strength for comparison only. |
| Crack control is required. |
|* Compression limit shown is 0.6 times the compressive strength for comparison only. |
|** See the detailed Uncracked Stress reports for full extent of tensile reinforcing required to control |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con 3 of 6 248
Page 105of Fri Mar 31 16:56:48 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

| cracking during transfer and handling. |


____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

CRACK CONTROL STEEL AND SPACING


(+ve = compression, -ve = tension)
___________________________________________________________________________________________________________________________
| | Bottom | Top of | |
| | of Beam | Beam | |
___________________________________________________________________________________________________________________________
| kb | 0.00| 0.00| | Adjustment coefficient for prestressing steel |
| cc | 0.00| 0.00|in | Clear concrete cover to steel closest to tension face |
| fs | 0.0| 0.0|ksi | Steel stress nearest to tension face after decompression |
| Max spacing | 0.00| 0.00|in | Maximum centre/centre spacing of steel closest to tension face |
___________________________________________________________________________________________________________________________

Beam not cracked, cracking controlled, or crack depth less than concrete cover.

________________________________________________________________________________________________________________________

DEFLECTION ESTIMATE AT ALL STAGES


_____________________________________________________________________________________________________________
| | Net Deflection | Change in Deflection| Span/Deflection Ratio |
|Location| Net @ | Net @ | Net Sust.| Net Total| Sustained| LL | Net Total| Sustained| LL |
| x | Erection |Completion| @ Final | @ Final | Growth+LL| alone |Deflection| Growth+LL| alone |
| ft | in | in | in | in | in | in | | | |
| Column | B | C | D | E | E - C | E - D | L/E * | L/(E-C) *| L/(E-D) |
_____________________________________________________________________________________________________________
| 0.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
| 1.520| -0.003 | -0.005 | -0.026 | -0.026 | -0.022 | 0.000 | 8668 | 10550 | 0 |
| 3.420| -0.006 | -0.010 | -0.056 | -0.056 | -0.046 | 0.000 | 4044 | 4922 | 0 |
| 5.320| -0.008 | -0.014 | -0.081 | -0.081 | -0.066 | 0.000 | 2828 | 3441 | 0 |
| 7.220| -0.010 | -0.017 | -0.097 | -0.097 | -0.080 | 0.000 | 2353 | 2864 | 0 |
| 9.120| -0.010 | -0.019 | -0.104 | -0.104 | -0.085 | 0.000 | 2196 | 2673 | 0 |
| 9.500| -0.010 | -0.019 | -0.104 | -0.104 | -0.085 | 0.000 | 2192 | 2668 | 0 |
| 9.880| -0.010 | -0.019 | -0.104 | -0.104 | -0.085 | 0.000 | 2196 | 2673 | 0 |
| 11.020| -0.010 | -0.018 | -0.101 | -0.101 | -0.083 | 0.000 | 2261 | 2752 | 0 |
| 11.780| -0.010 | -0.017 | -0.097 | -0.097 | -0.080 | 0.000 | 2353 | 2864 | 0 |
| 13.680| -0.008 | -0.014 | -0.081 | -0.081 | -0.066 | 0.000 | 2828 | 3441 | 0 |
| 15.580| -0.006 | -0.010 | -0.056 | -0.056 | -0.046 | 0.000 | 4044 | 4922 | 0 |
| 17.480| -0.003 | -0.005 | -0.026 | -0.026 | -0.022 | 0.000 | 8668 | 10550 | 0 |
| 19.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
_____________________________________________________________________________________________________________
| Col. B |Net deflection at erection includes all dead loads applied before the cast-in-place pour plus |
| | long-time deflection growth of the beam weight up to erection. |
| Col. C |Net deflection at completion of construction includes all dead loads plus long-time deflection |
| | growth of the dead load up to completion. |
| Col. D |Net sustained deflection at final includes all dead loads, and sustained live loads, plus |
| | long-time deflection growth. |
| Col. E |Net total deflection at final includes all dead loads, and all live loads, plus long-time |
| | deflection growth. |
| Note |Sustained deflection or growth includes dead loads and sustained live loads. |
| * |Span/deflection ratio is maximized with or without the inclusion of live load. |
_____________________________________________________________________________________________________________

Span/Deflection Limits: Sustained Load Growth + LL = L / 480 for non-structural attachments


Sustained Load Growth + LL = L / 240 otherwise
LL alone = L / 360 for floors *
LL alone = L / 180 for roofs *
* See the Vibration Check in Service report for more specific vibration guidelines

________________________________________________________________________________________________________________________

UNRESTRAINED SUPPORT ROTATIONS AT ALL STAGES


(+ve = clockwise rotation)
________________________________________________________________________________________
| | Net Rotation | Change in Rotation |
| Support| Net @ | Net @ | Net DL | Net Total | DL growth | LL |
|Location| Erection | Completion | @ Final | @ Final | + LL | alone |
| | degrees | degrees | degrees | degrees | degrees | degrees |
| Column | B | C | D | E | E - C | E - D |
________________________________________________________________________________________
| Left| 0.0084 | 0.0149 | 0.0837 | 0.0837 | 0.0688 | 0.0000 |
| Right| -0.0084 | -0.0149 | -0.0837 | -0.0837 | -0.0688 | 0.0000 |
________________________________________________________________________________________

UNRESTRAINED LONGITUDINAL CHANGE OF LENGTH DUE TO CREEP AND SHRINKAGE


(-ve = shortening, +ve = elongation)
__________________________________________________________________________________________________
| | Total Change of Length | Difference in Change |
| | Erection | Composite|Completion| Final | | to Compl.| to Final | to Final |
| | in | in | in | in | | in | in | in |
| | B | | C | D | | C - B | D - C | D - B |
__________________________________________________________________________________________________
| Creep| 0.0000| 0.0000| 0.0000| 0.0000| | 0.0000| 0.0000| 0.0000|
| Shrink.| -0.0412| -0.0476| -0.0706| -0.1071| | -0.0294| -0.0365| -0.0659|
| Total| -0.0412| -0.0476| -0.0706| -0.1071| | -0.0294| -0.0365| -0.0659|
__________________________________________________________________________________________________

Elastic Shortening = 0.0000 in

________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

FLEXURAL DESIGN CHECK IN FINAL SERVICE


________________________________________________________________________________________________________________________
| | Design | Cracking | Minimum * | Design | Depth in | Net Tensile| Flexural | Ø | Warnings |
| | Moment | Moment | Flexural | Strength | Compression| Strain |Classication| | & Notes |
| x | Mu | Mcr | Strength | ØMn | c | | | | |
| ft | kip.ft | kip.ft | kip.ft | kip.ft | in | | | | |
________________________________________________________________________________________________________________________
| 0.000| 0.00| 43.64| 0.00| 0.12| 5.56| 0.0000| Tension | 0.90| 3 |
| 1.520| 16.32| 48.46| 21.76| 136.72| 2.92| 0.0216| Tension | 0.90| |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con 4 of 6 248
Page 106of Fri Mar 31 16:56:48 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

| 1.520| -30.47| 48.46| -40.62| -136.72| 2.92| 0.0216| Tension | 0.90| |


| 3.420| 32.74| 48.46| 43.65| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 3.420| -61.10| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 5.320| 44.71| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 5.320| -83.45| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 7.220| 52.25| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 7.220| -97.52| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.120| 55.36| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.120| -103.32| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.500| 55.45| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.500| -103.49| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.880| 55.36| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.880| -103.32| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 11.020| 54.03| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 11.020| -100.84| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 11.780| 52.25| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 11.780| -97.52| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 13.680| 44.71| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 13.680| -83.45| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 15.580| 32.74| 48.46| 43.65| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 15.580| -61.10| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 17.480| 16.32| 48.46| 21.76| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 17.480| -30.47| 48.46| -40.62| -136.72| 2.92| 0.0216| Tension | 0.90| |
| 19.000| 0.00| 43.64| 0.00| 0.12| 5.56| 0.0000| Tension | 0.90| 3 |
| |
________________________________________________________________________________________________________________________
|Points of Maximum and Minimum Factored Moment |
| 9.500| 55.45| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.500| -103.49| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
|Points of Maximum Ratio of Factored Moment to Design Strength |
| 9.500| 55.45| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 9.500| -103.49| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
|Points of Maximum Ratio of Minimum Strength to Design Strength |
| 5.130| 43.71| 48.46| 58.16| 136.72| 2.92| 0.0216| Tension | 0.90| |
| 2.280| -43.71| 48.46| -58.16| -136.72| 2.92| 0.0216| Tension | 0.90| |
________________________________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design strength is based on a reduced maximum concrete strain to avoid steel slippage or rupture. See |
| | Flexural Design Detail Report and Help file's Technical Background for more information. |
| * |Minimum Flexural Strength is 1.2 Mcr or 4/3 Mu [ACI 318-14::9.6/Option F10] |
|ØMn(As,min) is the factored flexural strength based on the minimum required area for tensile steel required by the |
| selected code. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods (Option G3). |
|See the Flexural Design Details text report for more details. |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR DESIGN CHECK IN FINAL SERVICE


_____________________________________________________________________________________________________
| | Design | Vertical | Concrete | Required | Strength Provided | Warnings |
| | Shear | Prestress| Strength | Stirrups | Stirrups | Total | & Notes |
| x | Vu | Vp | ØVc | ØVs | ØVs | ØVn | |
| ft | kip | kip | kip | kip | kip | kip | |
_____________________________________________________________________________________________________
| 0.000| -17.23| 0.00| -20.77| -7.79| -36.88| -57.65| 1 3 5 |
| 1.520| -17.23| 0.00| -21.72| -7.49| -35.46| -57.18| 1 3 |
| 3.420| -13.94| 0.00| -20.10| -7.49| -35.46| -55.56| 1 |
| 5.320| -9.59| 0.00| -19.98| 0.00| -17.73| -37.71| 5 |
| 7.220| -5.23| 0.00| -19.98| 0.00| -17.73| -37.71| 5 |
| 9.120| -0.87| 0.00| -19.98| 0.00| -17.73| -37.71| 5 |
| 9.500| 0.00| 0.00| -19.98| 0.00| -17.73| -37.71| 5 |
| 9.500| 0.00| 0.00| 19.98| 0.00| 17.73| 37.71| 5 |
| 9.880| 0.87| 0.00| 19.98| 0.00| 17.73| 37.71| 5 |
| 11.020| 3.49| 0.00| 19.98| 0.00| 17.73| 37.71| 5 |
| 11.780| 5.23| 0.00| 19.98| 0.00| 17.73| 37.71| 5 |
| 13.680| 9.59| 0.00| 19.98| 0.00| 17.73| 37.71| 5 |
| 15.580| 13.94| 0.00| 20.10| 7.49| 35.46| 55.56| 1 |
| 17.480| 17.23| 0.00| 21.72| 7.49| 35.46| 57.18| 1 3 |
| 19.000| 17.23| 0.00| 20.77| 7.79| 36.88| 57.65| 1 3 5 |
_____________________________________________________________________________________________________
|Warnings & Notes |
|Note [1]|Transverse shear steel is required. See the Shear Transvese Reinforcing Design Check |
| | report. |
|Note [3]|Design shear force at critical section near support used [ACI 318-14::7.4.3.2/9.4.3.2]. |
|Note [5]|Calculation of the shear strength of the concrete used the simplified method [ACI |
| | 318-14::22.5.5.1/22.5.8.2]. |
| Note |The PCI recommended Zia/Hsu method was used to calculate the above shear design check |
| | results [PCI Handbbok 8th ed. section 5.4.1]. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods |
| | (Option G3). |
|See the Shear Design Check Details text report for more details. |
_____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR TRANSVERSE REINFORCING DESIGN CHECK IN FINAL SERVICE


_________________________________________________________________________________________________
| |Shear Steel|Shear Steel|Shear Steel| Stirrup | Stirrup Spacing | Warnings |
| | Grade | Required | Provided | Provided | Provided | Max. Allow| & Notes |
| x | fy | Av/s | Av/s | Av | s | s | |
| ft | ksi | in^2/ft | in^2/ft | in^2 | in | in | |
_________________________________________________________________________________________________
| 0.000| 60.0| 0.093| 0.440| 0.220| 6.00| 11.17| 1 4 5 |
| 1.520| 60.0| 0.093| 0.440| 0.220| 6.00| 10.75| 1 4 5 |
| 3.420| 60.0| 0.093| 0.440| 0.220| 6.00| 10.75| 1 5 |
| 5.320| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 7.220| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.120| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.500| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.500| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 9.880| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 11.020| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 11.780| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |
| 13.680| 60.0| 0.000| 0.220| 0.220| 12.00| 0.00| |

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con 5 of 6 248
Page 107of Fri Mar 31 16:56:48 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

| 15.580| 60.0| 0.093| 0.440| 0.220| 6.00| 10.75| 1 5 |


| 17.480| 60.0| 0.093| 0.440| 0.220| 6.00| 10.75| 1 4 5 |
| 19.000| 60.0| 0.093| 0.440| 0.220| 6.00| 11.17| 1 4 5 |
_________________________________________________________________________________________________
|Warnings & Notes |
|Warn.[A]|WARNING, Shear stirrup spacing is too wide. |
| |Extent: x = at 5.130 ft, at 13.870 ft |
|Note [1]|Amount of shear steel required represents minimum code requirements [ACI |
| | 318-14::9.6.3.3]. |
|Note [4]|Design shear force at critical section near support used [ACI |
| | 318-14::7.4.3.2/9.4.3.2]. |
|Note [5]|Required stirrup spacing represents maximum code requirements [ACI 318-14::9.7.6.2.2].|
| Note |Shear steel requirements for pre-tension bursting have been included (calculation |
| | option S8). |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical |
| | methods (calculation option G3). |
| * |Portion of the total stirrup area required to resist torsional shear flow (one leg |
| | around periphery). |
| ** |Allowable reduction within flexural compression zone [ACI 318-14::9.5.4.5]. Limited to|
| | half the Total and Al minimum. |
|See the Shear Design Check Details text report for more details. |
_________________________________________________________________________________________________

________________________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con 6 of 6 248
Page 108of Fri Mar 31 16:56:48 2023
Flexure Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

Flexure Check - Final Service


(ACI 318-14)
200

160

120

80
Moment - kip.ft

40

-40

-80

-120

-160

-200

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Design Moment, Mu: +ve Bending
Min. Strength Required: +ve Bending
Design Strength, ØMn: +ve Bending
Factored Moment, Mu: -ve Bending
Min. Strength Required: -ve Bending
Design Strength, ØMn: -ve Bending

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con Page 109of 248 Fri Mar 31 16:56:59 2023
Shear Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

Shear Check - Final Service


(ACI 318-14)
100

80

60

40

20
Shear - kip

-20

-40

-60

-80

-100

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Design Shear, Vu
Total Strength Provided, ØVn
Concrete Strength Provided, ØVc
Critical Section for Shear Loading

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con Page 110of 248 Fri Mar 31 16:57:07 2023
Deflection - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

Deflection - Final Service


(ACI 318-14)
0.040

0.020

0.000

-0.020
Deflection - in

-0.040

-0.060

-0.080

-0.100

-0.120

-0.140

-0.160

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Deflection @ Erection
Deflection On Completion
Final Service Sustained Deflection
Final Service Sust. + LL Deflection

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con Page 111of 248 Fri Mar 31 16:58:01 2023
Deflection Limits - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

Deflection Limits - Final Service


(ACI 318-14)
2.000

1.600

1.200

0.800
Deflection - in

0.400

0.000

-0.400

-0.800

-1.200

-1.600

-2.000

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Sustained Load Growth + Live Load
Sust.+LL Maximum Limit (L/240)
Sust.+LL Non-Structural Limit (L/480)
Live Load Only
LL Limit for Roofs (L/180)
LL Limit for Floors (L/360)

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con Page 112of 248 Fri Mar 31 16:58:38 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

Concrete Stress (beam) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con Page 113of 248 Fri Mar 31 16:58:52 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: PB1-Wind Suction

Concrete Stress (Sust) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.00 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20 17.10 19.00

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - PB-001 Beam Design-WIND SCTION.con Page 114of 248 Fri Mar 31 16:59:02 2023
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST BEAM / lLINTEL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter G

Precast Lintel design

Page 115of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : PRECAST LINTEL BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Beam design type markup,


* Precast Lintel beam design considered as Simply supported
* Precast Lintel beam design done with concise beam Software
Note: - *Without highlighted beam is checked but not included in the package and it will available upon request

Level -2 Litel Beam layout:

Page 116of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST LINTEL BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Level-2 Precast Lintel beam Design: TYPE LB-01

Material property data:


Grade of concrete = 6000 Psi
Grade of steel = 60 Ksi
Density of concrete = 0.15 Kip/ft³

Beam Geometry data:


Length of beam = 16 ft
Width of beam = 0.33 ft (4" Interior Wythe is Considered as
Depth of beam = 4.14 ft Structural Wythe in Concise Software)
Thickness of screed = 0 ft
Beam support condtion = SSD

Beam Loading:
Self weight of beam = 0.33x4.14x0.150 = 0.205 Kip/ft

DESIGN LOADS:

Roof truss load on Beam:

P1: Load from Right side Roof:

Dead Load (Refer truss design) (U12 - Truss) = 0.62 Kip


(U25 - Truss) = 1.12 Kip
(U26 - Truss) = 1.14 Kip
(U28 - Truss) = 1.15 Kip
(U30 - Truss) = 1.13 Kip
(U32 - Truss) = 1.13 Kip
(U34 - Truss) = 1.12 Kip

Live Load (Refer truss design) (U12 - Truss) = 0.65 Kip


(U25 - Truss) = 1.03 Kip
(U26 - Truss) = 1.04 Kip
(U28 - Truss) = 1.04 Kip
(U30 - Truss) = 1.02 Kip
(U32 - Truss) = 1.02 Kip
(U34 - Truss) = 1.02 Kip

Total dead load on beam = 7.407 Kip


Total live load on beam = 6.829 Kip

Page 117of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST LINTEL BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Loading Diagram:

Reinforcement design :
Bottom Tension reinforcement at span
Required moment capacity,Mu (refer concise report) = 48.83 Kip-ft
Provided Moment capacity,Mn (refer concise report) = 75.27 Kip-ft

48.8 < 75.27 Hence safe

Shear reinforcementCalculation:
at Ends of Beam:
Required Shear capacity,Vs (refer concise report) = 10.48 Kip
Provided Shear capacity,Vn (refer concise report) = 39.00 Kip
Provided reinforcement As = #3 - 12 in = 0.11 in²/ft

10.48 < 39 Hence safe

At Interior of Beam:
Required Shear capacity,Vs (refer concise report) = 2.00 Kip
Provided Shear capacity,Vn (refer concise report) = 39.00 Kip
Provided reinforcement As = #3 - 12 in = 0.11 in²/ft

2 < 39 Hence safe

Provide #3 stirrups spacing @ 12" O.C for Full Length

Page 118of 248


BSL - LB-01 Lintel' Beam Design.con
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con Page 119of 248 Fri Mar 31 15:27:20 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

SUMMARY REPORT

Design Code Used: ACI 318-14

________________________________________________________________________________________________________________________

NON-DEFAULT OPTION SETTINGS

** ON ** P1: Vary user defined losses along beam


** ON ** F1: Check minimum strength at critical sections only
** OFF ** F7: Reduce φ in the development length of strands (CSA A23.3 only)
** OFF ** F8: Use a rectangular stress block at concrete ultimate strain
** ON ** F10: Use the cracking moment for minimum flexural strength (ACI and NZ codes for non-prestressed bea
** ON ** S1: Use the simplified shear method if applicable
** ON ** S2: Take the best of the detailed and simplified method
** ON ** S5: Use Zia/Hsu Method for torsion as per PCI Standard Practice guide (ACI Codes Only)
** ON ** S8: Calculate pre-tensioned bursting steel requirements
** ON ** S10: Use the ultimate section capacity for horizontal shear (moment region check)
** OFF ** D3: Have Concise Beam calculate long-term deflection multipliers for prestressed Beams

________________________________________________________________________________________________________________________

CONCRETE MATERIAL PROPERTIES

Precast Beam
Concrete Density, Wt 150 lb/ft^3
Compressive Strength, f'c 6000.0 psi
Flexural Modulus of Rupture, fr 581 psi
Modulus of Elasticity, Ec 4.696E+6 psi

PRECAST CONCRETE MIX, SCHEDULE, AND SERVICE ENVIRONMENT


(schedule from time of casting precast beam at 0 days)

Cement Content 691 lb/yd^3 Age at Stripping 2.00 days


Air Content 5.00 % Age at Erection 40 days
Slump 1.97 in Age at Cast-in-Place Pour 50 days
Aggregate Mix 0.40 fines/total Age Cast-in-Place is Composite 53 days
Aggregate Size 0.79 in Age Construction is Complete 143 days
Basic Shrinkage Strain 0.000780 in/in
Curing Method Moist Relative Humidity in Service 70 %
Concrete Hydration Rate Normal Ambient Temperature in Service 20 deg
Exposure in Service Inter

________________________________________________________________________________________________________________________

PRECAST BEAM LAYOUT


____________________________________________________________________________________________________________________
|Seg.| Segment Length | Section Identification | Offset |
| No.| From | To | Length | Folder | Section | Section | Z | Y |
| | ft | ft | ft | Name | Name | Type | in | in |
____________________________________________________________________________________________________________________
| 1| 0.000| 16.000| 16.000| B1 | LB-01- 4.145' | Solid Beam | 0.00| 0.00|
____________________________________________________________________________________________________________________

The cast-in-place pour, if defined, has been turned off (not included).

Warning: The span to depth ratio of the beam is less than 4 and could be classified as a deep beam.
Concise Beam uses simple beam theory which may not applicable to deep beams.

Span Length at Transfer = 16.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 16.000 ft
Span Length during Lift = 16.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 16.000 ft
Span Length in Service = 16.000 ft, Centre of Supports, Left @ 0.000 ft, Right @ 16.000 ft
Total Beam Length = 16.000 ft, Bearing Length, Left = 3.00 in, Right = 3.00 in

________________________________________________________________________________________________________________________

GROSS PRECAST SECTION PROPERTIES (NON-COMPOSITE)


(based on Ec of the precast beam - transformed area of rebar and strand NOT included)
____________________________________________________________________________________________________________
|Seg.| Section Properties | Section | Section | Shear | Volume /| Section Moduli |
| No.| A | I | yb | Height | Width | Width | Surface | Sb | St |
| | in^2 | in^4 | in | in | in | in | in | in^3 | in^3 |
____________________________________________________________________________________________________________
| 1| 199.0| 41020| 24.87| 49.74| 4.00| 4.00| 1.85| -1649| 1649|
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED SECTION PROPERTIES SUMMARY


____________________________________________________________________________________________________
| | Net Precast Section | Transformed Precast Section | Transformed Precast Section |
| | at Transfer (based on Eci) | at Transfer (based on Eci) | at 28 Days (based on Ec) |
| |(include rebar,deduct strand)| (include rebar and strand) | (include rebar and strand) |
| x | A | I | yb | A | I | yb | A | I | yb |
| ft | in^2 | in^4 | in | in^2 | in^4 | in | in^2 | in^4 | in |
____________________________________________________________________________________________________
| 0.000| 199.0| 41022| 24.87| 199.0| 41022| 24.87| 199.0| 41021| 24.87|
| 1.280| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 2.750| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 4.320| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 5.760| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 7.360| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 8.080| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 8.800| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 10.400| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 11.840| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 13.280| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 14.880| 204.1| 42774| 24.89| 204.1| 42774| 24.89| 202.7| 42301| 24.89|
| 16.000| 199.0| 41022| 24.87| 199.0| 41022| 24.87| 199.0| 41021| 24.87|
____________________________________________________________________________________________________
|These section properties can used to calculate uncracked concrete stresses using the following |
| guidelines. |
|- Net Precast Section at Transfer properties are used with the initial prestress after transfer |
| (after elastic shortening loss). |

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con 1 of 6 248
Page 120of Fri Mar 31 15:27:33 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

|- Transformed Precast Section at Transfer properties are used with the precast beam self-weight. |
|- Transformed Precast Section at 28 Days properties are used with external loads applied to the |
| non-composite precast beam. |
____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LONGITUDINAL REINFORCING STEEL


________________________________________________________________________________________________________________________
|ID| Qty | Steel | Bar | | Bar |End Location & Type| Bar | | Cross |Vertical| Offset ** |
| | | Grade | Size | | Area | From | | To | | Spacing| | Spacing| Offset | Reference |
| | | ksi |C=coated| | in^2 | ft | *| ft | *| in | | in | in | |
________________________________________________________________________________________________________________________
| 1| 1.000| 60.0| # 4 | | 0.200| 0.000|SE|16.000|SE| 4.00| | - | 2.00| Bottom of Precast Beam |
| 2| 1.000| 60.0| # 4 | | 0.200| 0.000|SE|16.000|SE| 4.00| | - | 2.00| Top of Precast Beam |
| 3| 1.000| 60.0| # 3 | | 0.110| 0.000|SE|16.000|SE| 4.00| | - | 14.00| Bottom of Precast Beam |
| 4| 1.000| 60.0| # 3 | | 0.110| 0.000|SE|16.000|SE| 4.00| | - | 26.00| Bottom of Precast Beam |
| 5| 1.000| 60.0| # 3 | | 0.110| 0.000|SE|16.000|SE| 4.00| | - | 40.00| Bottom of Precast Beam |
________________________________________________________________________________________________________________________
|* Straight Embeddment (SE), Fully Developed (FD), Standard Hook (SH), Headed Bar (HB) |
|** Offsets are measured up from the bottom or down from the top |
|See the "Development Length" text report for details of the bar and wire development lengths |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR STIRRUPS
_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 16.000| 60.0| *| # 3 | 1| 0.11| 12.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

INTERFACE SHEAR TIES


_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 16.000| 60.0| *| # 3 | 1| 0.11| 12.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

________________________________________________________________________________________________________________________

APPLIED LOADS
____________________________________________________________________________________________________________________________
| Load Group | Stages Applied | Load Details ** |
| & Type | & Distribution | (left to right) |
____________________________________________________________________________________________________________________________
|Beam Weight(1) |Erection to Final Service |Segment #0: [V] 0.207 kip/ft full length |
| D: DL, Factory Produced |No Load Distribution | |
| | | |
|DL From Right side Truss |Final Service stage only |Truss - U12: [V] 0.623 kip @ 0 ft |
| D: DL, General |No Load Distribution |Truss - U25: [V] 1.12 kip @ 2.75 ft |
| | |Truss - U26: [V] 1.14 kip @ 5.41 ft |
| | |Truss - U28: [V] 1.15 kip @ 8.08 ft |
| | |Truss - U30: [V] 1.13 kip @ 10.57 ft |
| | |Truss - U32: [V] 1.13 kip @ 13.23 ft |
| | |Truss - U34: [V] 1.12 kip @ 15.9 ft |
| | | |
|LL From Right side Truss |Final Service stage only |Truss - U12: [V] 0.623 kip @ 0 ft |
| L: LL, General |No Load Distribution |Truss - U25: [V] 1.03 kip @ 2.75 ft |
| | |Truss - U26: [V] 1.04 kip @ 5.41 ft |
| | |Truss - U28: [V] 1.04 kip @ 8.08 ft |
| | |Truss - U30: [V] 1.02 kip @ 10.57 ft |
| | |Truss - U32: [V] 1.02 kip @ 13.23 ft |
| | |Truss - U34: [V] 1.02 kip @ 15.9 ft |
| | | |
____________________________________________________________________________________________________________________________
|* indicates load groups generated automatically by Concise Beam. |
|** [V] Vertical Load, [M] Moment, [T] Torsion. |
____________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LOAD COMBINATIONS

Serviceability (SLS) & Fatigue (FLS) Limit State Combinations (used individually)
SLS Stress : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S + 1.00Ws + 0.60Wu
SLS Deflect : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S
FLS Fatigue : 1.00P + 1.00D + 1.00F + 1.00L + 1.00L1 + 1.00Lr

Ultimate (Strength) Limit State (ULS) Combinations (searched collectively to obtain envelope)
1: ULS Combo 1 : 1.40D + 1.40F
2: ULS Combo 2 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50Lr
3: ULS Combo 3 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50S
4: ULS Combo 4 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50R
5: ULS Combo 5 : 1.20D + 0.50L + 1.00L1 + 1.60Lr
6: ULS Combo 6 : 1.20D + 0.50L + 1.00L1 + 1.60S
7: ULS Combo 7 : 1.20D + 0.50L + 1.00L1 + 1.60R
8: ULS Combo 8 : 1.20D + 1.60Lr + 0.80Ws + 0.50Wu
9: ULS Combo 9 : 1.20D + 1.60S + 0.80Ws + 0.50Wu
10: ULS Combo 10 : 1.20D + 1.60R + 0.80Ws + 0.50Wu
11: ULS Combo 11 : 1.20D + 0.50L + 1.00L1 + 0.50Lr + 1.60Ws + 1.00Wu
12: ULS Combo 12 : 1.20D + 0.50L + 1.00L1 + 0.50S + 1.60Ws + 1.00Wu
13: ULS Combo 13 : 1.20D + 0.50L + 1.00L1 + 0.50R + 1.60Ws + 1.00Wu
14: ULS Combo 14 : 1.20D + 0.50L + 1.00L1 + 0.20S + 1.40Es + 1.00Eu
15: ULS Combo 15 : 0.90D + 1.60L + 1.60L1 + 0.50Lr
16: ULS Combo 16 : 0.90D + 1.60Ws + 1.00Wu
17: ULS Combo 17 : 0.90D + 0.90F + 1.40Es + 1.00Eu

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con 2 of 6 248
Page 121of Fri Mar 31 15:27:33 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

________________________________________________________________________________________________________________________

COMBINED ANALYSIS IN SERVICE - LOAD COMBINATION RESULTS


(external loads only)
______________________________________________________________________________________________________________
| Station| SLS (stress) Load Combination | ULS Load Envelopes |
| | Moment | Moment | Shear | Moment |
| x | Sustained | Total Load | Total Load |Govern.| Total Load |Govern.|
| ft | kip.ft | kip.ft | kip | Combo.| kip.ft | Combo.|
| | | min | max | min | max |min|max| min | max |min|max|
______________________________________________________________________________________________________________
| 0.000| 0.00 | 0.00 | 0.00 | 4.05 | 9.53 | 16| 2| 0.00 | 0.00 | 1| 1|
| 1.280| 8.89 | 8.89 | 8.89 | 3.81 | 9.21 | 16| 2| 5.03 | 12.00 | 16| 2|
| 2.750| 18.69 | 18.69 | 18.69 | 3.53 | 8.85 | 16| 2| 10.42 | 25.27 | 16| 2|
| 2.750| 18.69 | 18.69 | 18.69 | 2.52 | 5.85 | 16| 2| 10.42 | 25.27 | 16| 2|
| 4.320| 25.28 | 25.28 | 25.28 | 2.23 | 5.46 | 16| 2| 14.15 | 34.15 | 16| 2|
| 5.760| 30.11 | 30.11 | 30.11 | 0.94 | 2.07 | 16| 2| 16.82 | 40.70 | 16| 2|
| 7.360| 32.34 | 32.34 | 32.34 | 0.64 | 1.68 | 16| 2| 18.08 | 43.71 | 16| 2|
| 8.080| 33.17 | 33.17 | 33.17 | 0.50 | 1.50 | 16| 2| 18.49 | 44.85 | 16| 2|
| 8.080| 33.17 | 33.17 | 33.17 | -1.55 | -0.53 | 2| 16| 18.49 | 44.85 | 16| 2|
| 8.800| 32.31 | 32.31 | 32.31 | -1.73 | -0.66 | 2| 16| 18.06 | 43.67 | 16| 2|
| 10.400| 30.02 | 30.02 | 30.02 | -2.12 | -0.96 | 2| 16| 16.76 | 40.59 | 16| 2|
| 11.840| 24.78 | 24.78 | 24.78 | -5.47 | -2.25 | 2| 16| 13.89 | 33.48 | 16| 2|
| 13.280| 18.64 | 18.64 | 18.64 | -8.82 | -3.53 | 2| 16| 10.40 | 25.20 | 16| 2|
| 14.880| 7.99 | 7.99 | 7.99 | -9.21 | -3.83 | 2| 16| 4.51 | 10.77 | 16| 2|
| 16.000| 0.00 | 0.00 | 0.00 | -12.47 | -5.05 | 2| 16| 0.00 | 0.00 | 1| 1|
______________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SUPPORT REACTIONS DURING HANDLING


(+ve = upwards, counter-clockwise)
______________________________________________________________________
| | Initial Lifting | Erection Lifting |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical | Vertical |
| | kip | kip | kip | kip |
______________________________________________________________________
| Unfactored Load Group Effects |
| | | | | |
| Load Envelope Effects |
|SLS Minimum | 0.00 | 0.00 | 0.00 | 0.00 |
|SLS Maximum | 0.00 | 0.00 | 0.00 | 0.00 |
______________________________________________________________________

REACTIONS ON FINAL SUPPORTS


(+ve = upwards, counter-clockwise)
________________________________________________________________________________________________
| | During CIP Pour | In Service |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical[*]| Torsion[*] | Vertical[*]| Torsion[*] |
| | kip | kip | kip | kip.ft | kip | kip.ft |
________________________________________________________________________________________________
| Unfactored Load Group Effects |
|Beam Weight(1) | 1.66 | 1.66 | 1.66 | 0.00 | 1.66 | 0.00 |
|DL From Right si| | | 3.46 | 0.00 | 3.95 | 0.00 |
|LL From Right si| | | 3.21 | 0.00 | 3.58 | 0.00 |
| | | | | | | |
| Load Envelope Effects |
|SLS DL | | | 5.12 | 0.00 | 5.61 | 0.00 |
|SLS Sustain | | | 8.33 | 0.00 | 9.20 | 0.00 |
|SLS Minimum | 1.66 | 1.66 | 8.33 | 0.00 | 9.20 | 0.00 |
|SLS Maximum | 1.66 | 1.66 | 8.33 | 0.00 | 9.20 | 0.00 |
|ULS Minimum | | | 4.61 [16]| 0.00 [ 1]| 5.05 [16]| 0.00 [ 1]|
|ULS Maximum | | | 11.28 [ 2]| 0.00 [ 1]| 12.47 [ 2]| 0.00 [ 1]|
________________________________________________________________________________________________
|* Governing ULS Load Combination (below) |
________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED CONCRETE STRESS RESULTS


(+ve = compression, -ve = tension)
____________________________________________________________________________________________________________
| | x | Stress | Limit * | |
| Location | ft | psi | psi | |
____________________________________________________________________________________________________________
|STRESSES DURING INITIAL LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 2100| |
| Bottom of Beam | 0.000| 0| 2100| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -444| |
| Bottom of Beam | 0.000| 0| -444| |
____________________________________________________________________________________________________________
|STRESSES DURING ERECTION LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| |
| Bottom of Beam | 0.000| 0| -581| |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE | |
|Critical Compression | |
| Top of Beam | 8.080| 234| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| Not cracked |
| Bottom of Beam | 8.080| -234| -581| Not cracked |
____________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con 3 of 6 248
Page 122of Fri Mar 31 15:27:33 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

|STRESSES IN SERVICE (SUSTAINED LOADS ONLY) | |


|Critical Compression | |
| Top of Beam | 8.080| 234| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
____________________________________________________________________________________________________________
|* Tensile stress limit shown for the precast beam is the flexural cracking strength for comparison only. |
| Crack control is required. |
|* Compression limit shown is 0.6 times the compressive strength for comparison only. |
|** See the detailed Uncracked Stress reports for full extent of tensile reinforcing required to control |
| cracking during transfer and handling. |
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

CRACK CONTROL STEEL AND SPACING


(+ve = compression, -ve = tension)
___________________________________________________________________________________________________________________________
| | Bottom | Top of | |
| | of Beam | Beam | |
___________________________________________________________________________________________________________________________
| kb | 1.00| 0.00| | Adjustment coefficient for prestressing steel |
| cc | 1.75| 0.00|in | Clear concrete cover to steel closest to tension face |
| fs | -31.0| 0.0|ksi | Steel stress nearest to tension face after decompression |
| Max spacing | 14.95| 0.00|in | Maximum centre/centre spacing of steel closest to tension face |
___________________________________________________________________________________________________________________________

Beam not cracked, cracking controlled, or crack depth less than concrete cover.

________________________________________________________________________________________________________________________

DEFLECTION ESTIMATE AT ALL STAGES


_____________________________________________________________________________________________________________
| | Net Deflection | Change in Deflection| Span/Deflection Ratio |
|Location| Net @ | Net @ | Net Sust.| Net Total| Sustained| LL | Net Total| Sustained| LL |
| x | Erection |Completion| @ Final | @ Final | Growth+LL| alone |Deflection| Growth+LL| alone |
| ft | in | in | in | in | in | in | | | |
| Column | B | C | D | E | E - C | E - D | L/E * | L/(E-C) *| L/(E-D) |
_____________________________________________________________________________________________________________
| 0.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
| 1.280| 0.000 | 0.000 | -0.005 | -0.005 | -0.005 | 0.000 | 35009 | 40827 | 0 |
| 2.750| 0.000 | -0.002 | -0.011 | -0.011 | -0.010 | 0.000 | 16976 | 19790 | 0 |
| 4.320| -0.001 | -0.002 | -0.016 | -0.016 | -0.014 | 0.000 | 11682 | 13616 | 0 |
| 5.760| -0.001 | -0.003 | -0.020 | -0.020 | -0.017 | 0.000 | 9712 | 11317 | 0 |
| 7.360| -0.002 | -0.003 | -0.022 | -0.022 | -0.019 | 0.000 | 8871 | 10336 | 0 |
| 8.080| -0.002 | -0.003 | -0.022 | -0.022 | -0.019 | 0.000 | 8801 | 10253 | 0 |
| 8.800| -0.002 | -0.003 | -0.022 | -0.022 | -0.019 | 0.000 | 8906 | 10375 | 0 |
| 10.400| -0.001 | -0.003 | -0.019 | -0.019 | -0.017 | 0.000 | 9846 | 11471 | 0 |
| 11.840| -0.001 | -0.002 | -0.016 | -0.016 | -0.014 | 0.000 | 11993 | 13973 | 0 |
| 13.280| 0.000 | -0.002 | -0.011 | -0.011 | -0.010 | 0.000 | 17099 | 19925 | 0 |
| 14.880| 0.000 | 0.000 | -0.005 | -0.005 | -0.004 | 0.000 | 39771 | 46357 | 0 |
| 16.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
_____________________________________________________________________________________________________________
| Col. B |Net deflection at erection includes all dead loads applied before the cast-in-place pour plus |
| | long-time deflection growth of the beam weight up to erection. |
| Col. C |Net deflection at completion of construction includes all dead loads plus long-time deflection |
| | growth of the dead load up to completion. |
| Col. D |Net sustained deflection at final includes all dead loads, and sustained live loads, plus |
| | long-time deflection growth. |
| Col. E |Net total deflection at final includes all dead loads, and all live loads, plus long-time |
| | deflection growth. |
| Note |Sustained deflection or growth includes dead loads and sustained live loads. |
| * |Span/deflection ratio is maximized with or without the inclusion of live load. |
_____________________________________________________________________________________________________________

Span/Deflection Limits: Sustained Load Growth + LL = L / 480 for non-structural attachments


Sustained Load Growth + LL = L / 240 otherwise
LL alone = L / 360 for floors *
LL alone = L / 180 for roofs *
* See the Vibration Check in Service report for more specific vibration guidelines

________________________________________________________________________________________________________________________

UNRESTRAINED SUPPORT ROTATIONS AT ALL STAGES


(+ve = clockwise rotation)
________________________________________________________________________________________
| | Net Rotation | Change in Rotation |
| Support| Net @ | Net @ | Net DL | Net Total | DL growth | LL |
|Location| Erection | Completion | @ Final | @ Final | + LL | alone |
| | degrees | degrees | degrees | degrees | degrees | degrees |
| Column | B | C | D | E | E - C | E - D |
________________________________________________________________________________________
| Left| 0.0015 | 0.0030 | 0.0207 | 0.0207 | 0.0177 | 0.0000 |
| Right| -0.0015 | -0.0030 | -0.0208 | -0.0208 | -0.0178 | 0.0000 |
________________________________________________________________________________________

UNRESTRAINED LONGITUDINAL CHANGE OF LENGTH DUE TO CREEP AND SHRINKAGE


(-ve = shortening, +ve = elongation)
__________________________________________________________________________________________________
| | Total Change of Length | Difference in Change |
| | Erection | Composite|Completion| Final | | to Compl.| to Final | to Final |
| | in | in | in | in | | in | in | in |
| | B | | C | D | | C - B | D - C | D - B |
__________________________________________________________________________________________________
| Creep| 0.0000| 0.0000| 0.0000| 0.0000| | 0.0000| 0.0000| 0.0000|
| Shrink.| -0.0515| -0.0586| -0.0785| -0.1031| | -0.0270| -0.0246| -0.0516|
| Total| -0.0515| -0.0586| -0.0785| -0.1031| | -0.0270| -0.0246| -0.0516|
__________________________________________________________________________________________________

Elastic Shortening = 0.0000 in

________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

FLEXURAL DESIGN CHECK IN FINAL SERVICE

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con 4 of 6 248
Page 123of Fri Mar 31 15:27:33 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

________________________________________________________________________________________________________________________
| | Design | Cracking | Minimum * | Design | Depth in | Net Tensile| Flexural | Ø | Warnings |
| | Moment | Moment | Flexural | Strength | Compression| Strain |Classication| | & Notes |
| x | Mu | Mcr | Strength | ØMn | c | | | | |
| ft | kip.ft | kip.ft | kip.ft | kip.ft | in | | | | |
________________________________________________________________________________________________________________________
| 0.000| 0.00| 79.85| 0.00| 0.06| 6.30| 0.0000| Tension | 0.90| 3 |
| 1.280| 12.00| 82.29| 15.99| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 2.750| 25.27| 82.29| 33.69| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 4.320| 34.15| 82.29| 45.54| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 5.760| 40.70| 82.29| 54.27| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 7.360| 43.71| 82.29| 58.27| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 8.080| 44.85| 82.29| 59.80| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 8.800| 43.67| 82.29| 58.23| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 10.400| 40.59| 82.29| 54.12| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 11.840| 33.48| 82.29| 44.64| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 13.280| 25.20| 82.29| 33.60| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 14.880| 10.77| 82.29| 14.36| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 16.000| 0.00| 79.85| 0.00| 0.06| 6.30| 0.0000| Tension | 0.90| 3 |
| |
________________________________________________________________________________________________________________________
|Points of Maximum and Minimum Factored Moment |
| 8.080| 44.85| 82.29| 59.80| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 0.000| 0.00| 79.85| 0.00| -0.06| 6.59| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Factored Moment to Design Strength |
| 8.080| 44.85| 82.29| 59.80| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 0.000| 0.00| 79.85| 0.00| -0.06| 6.59| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Minimum Strength to Design Strength |
| 8.080| 44.85| 82.29| 59.80| 75.27| 2.11| 0.0600| Tension | 0.90| 3 |
| 0.000| 0.00| 79.85| 0.00| -0.06| 6.59| 0.0000| Tension | 0.90| 3 |
________________________________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design strength is based on a reduced maximum concrete strain to avoid steel slippage or rupture. See |
| | Flexural Design Detail Report and Help file's Technical Background for more information. |
| * |Minimum Flexural Strength is 1.2 Mcr or 4/3 Mu [ACI 318-14::9.6/Option F10] |
|ØMn(As,min) is the factored flexural strength based on the minimum required area for tensile steel required by the |
| selected code. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods (Option G3). |
|See the Flexural Design Details text report for more details. |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR DESIGN CHECK IN FINAL SERVICE


_____________________________________________________________________________________________________
| | Design | Vertical | Concrete | Required | Strength Provided | Warnings |
| | Shear | Prestress| Strength | Stirrups | Stirrups | Total | & Notes |
| x | Vu | Vp | ØVc | ØVs | ØVs | ØVn | |
| ft | kip | kip | kip | kip | kip | kip | |
_____________________________________________________________________________________________________
| 0.000| 9.50| 0.00| 20.62| 0.00| 18.30| 38.92| 3 5 |
| 1.280| 9.21| 0.00| 20.21| 0.00| 17.94| 38.14| 5 |
| 2.750| 8.85| 0.00| 20.21| 0.00| 17.94| 38.14| 5 |
| 2.750| 5.85| 0.00| 20.21| 0.00| 17.94| 38.14| 5 |
| 4.320| 5.46| 0.00| 20.21| 0.00| 17.94| 38.14| 5 |
| 5.760| 2.07| 0.00| 20.21| 0.00| 17.94| 38.14| 5 |
| 7.360| 1.68| 0.00| 20.21| 0.00| 17.94| 38.14| 5 |
| 8.080| 1.50| 0.00| 20.21| 0.00| 17.94| 38.14| 5 |
| 8.080| -1.55| 0.00| -20.21| 0.00| -17.94| -38.14| 5 |
| 8.800| -1.73| 0.00| -20.21| 0.00| -17.94| -38.14| 5 |
| 10.400| -2.12| 0.00| -20.21| 0.00| -17.94| -38.14| 5 |
| 11.840| -5.47| 0.00| -20.21| 0.00| -17.94| -38.14| 5 |
| 13.280| -8.82| 0.00| -20.21| 0.00| -17.94| -38.14| 5 |
| 14.880| -9.21| 0.00| -20.21| 0.00| -17.94| -38.14| 5 |
| 16.000| -9.46| 0.00| -20.62| 0.00| -18.30| -38.92| 3 5 |
_____________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design shear force at critical section near support used [ACI 318-14::7.4.3.2/9.4.3.2]. |
|Note [5]|Calculation of the shear strength of the concrete used the simplified method [ACI |
| | 318-14::22.5.5.1/22.5.8.2]. |
| Note |The PCI recommended Zia/Hsu method was used to calculate the above shear design check |
| | results [PCI Handbbok 8th ed. section 5.4.1]. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods |
| | (Option G3). |
|See the Shear Design Check Details text report for more details. |
_____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR TRANSVERSE REINFORCING DESIGN CHECK IN FINAL SERVICE


_________________________________________________________________________________________________
| |Shear Steel|Shear Steel|Shear Steel| Stirrup | Stirrup Spacing | Warnings |
| | Grade | Required | Provided | Provided | Provided | Max. Allow| & Notes |
| x | fy | Av/s | Av/s | Av | s | s | |
| ft | ksi | in^2/ft | in^2/ft | in^2 | in | in | |
_________________________________________________________________________________________________
| 0.000| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| 4 |
| 1.280| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 2.750| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 2.750| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 4.320| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 5.760| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 7.360| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 8.080| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 8.080| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 8.800| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 10.400| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 11.840| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 13.280| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 14.880| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 16.000| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| 4 |
_________________________________________________________________________________________________
|Warnings & Notes |
|Note [4]|Design shear force at critical section near support used [ACI |
| | 318-14::7.4.3.2/9.4.3.2]. |

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con 5 of 6 248
Page 124of Fri Mar 31 15:27:33 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

| Note |Shear steel requirements for pre-tension bursting have been included (calculation |
| | option S8). |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical |
| | methods (calculation option G3). |
| * |Portion of the total stirrup area required to resist torsional shear flow (one leg |
| | around periphery). |
| ** |Allowable reduction within flexural compression zone [ACI 318-14::9.5.4.5]. Limited to|
| | half the Total and Al minimum. |
|See the Shear Design Check Details text report for more details. |
_________________________________________________________________________________________________

________________________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con 6 of 6 248
Page 125of Fri Mar 31 15:27:33 2023
Flexure Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

Flexure Check - Final Service


(ACI 318-14)
160.0

140.0

120.0

100.0
Moment - kip.ft

80.0

60.0

40.0

20.0

0.0

-20.0

-40.0

0.00 1.60 3.20 4.80 6.40 8.00 9.60 11.20 12.80 14.40 16.00

Distance From Left End of Beam - ft


Design Moment, Mu: +ve Bending
Min. Strength Required: +ve Bending
Design Strength, ØMn: +ve Bending

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con Page 126of 248 Fri Mar 31 15:27:43 2023
Shear Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

Shear Check - Final Service


(ACI 318-14)
50.0

40.0

30.0

20.0

10.0
Shear - kip

0.0

-10.0

-20.0

-30.0

-40.0

-50.0

0.00 1.60 3.20 4.80 6.40 8.00 9.60 11.20 12.80 14.40 16.00

Distance From Left End of Beam - ft


Design Shear, Vu
Total Strength Provided, ØVn
Concrete Strength Provided, ØVc
Critical Section for Shear Loading

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con Page 127of 248 Fri Mar 31 15:27:51 2023
Deflection - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

Deflection - Final Service


(ACI 318-14)
0.008

0.004

0.000

-0.004
Deflection - in

-0.008

-0.012

-0.016

-0.020

-0.024

-0.028

-0.032

0.00 1.60 3.20 4.80 6.40 8.00 9.60 11.20 12.80 14.40 16.00

Distance From Left End of Beam - ft


Deflection @ Erection
Deflection On Completion
Final Service Sustained Deflection
Final Service Sust. + LL Deflection

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con Page 128of 248 Fri Mar 31 15:28:00 2023
Deflection Limits - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

Deflection Limits - Final Service


(ACI 318-14)
1.500

1.200

0.900

0.600
Deflection - in

0.300

0.000

-0.300

-0.600

-0.900

-1.200

-1.500

0.00 1.60 3.20 4.80 6.40 8.00 9.60 11.20 12.80 14.40 16.00

Distance From Left End of Beam - ft


Sustained Load Growth + Live Load
Sust.+LL Maximum Limit (L/240)
Sust.+LL Non-Structural Limit (L/480)
Live Load Only
LL Limit for Roofs (L/180)
LL Limit for Floors (L/360)

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con Page 129of 248 Fri Mar 31 15:28:07 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

Concrete Stress (beam) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.00 1.60 3.20 4.80 6.40 8.00 9.60 11.20 12.80 14.40 16.00

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con Page 130of 248 Fri Mar 31 15:28:19 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-01

Concrete Stress (Sust) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.00 1.60 3.20 4.80 6.40 8.00 9.60 11.20 12.80 14.40 16.00

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - LB-01 Lintel' Beam Design.con Page 131of 248 Fri Mar 31 15:28:28 2023
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST LINTEL BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Level-2 Precast Lintel beam Design: TYPE LB-04

Material property data:


Grade of concrete = 6000 Psi
Grade of steel = 60 Ksi
Density of concrete = 0.15 Kip/ft³

Beam Geometry data:


Length of beam = 8.16 ft
Width of beam = 0.33 ft (4" Interior Wythe is Considered as
Depth of beam = 2.45 ft Structural Wythe in Concise Software)
Thickness of screed = 0 ft
Beam support condtion = SSD

Beam Loading:
Self weight of beam = 0.33x2.45x0.150 = 0.121 Kip/ft

DESIGN LOADS:

Roof truss load on Beam:

P1: Load from Right side Roof:

Dead Load (Refer truss design) (U13 - Truss) = 1.07 Kip


(U29 - Truss) = 0.66 Kip
(U31 - Truss) = 0.66 Kip

Live Load (Refer truss design) (U13 - Truss) = 1.05 Kip


(U29 - Truss) = 0.61 Kip
(U31 - Truss) = 0.61 Kip

Total dead load on beam = 2.387 Kip


Total live load on beam = 2.267 Kip

Page 132of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST LINTEL BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Loading Diagram:

Reinforcement design :
Bottom Tension reinforcement at span
Required moment capacity,Mu (refer concise report) = 6 Kip-ft
Provided Moment capacity,Mn (refer concise report) = 31 Kip-ft

6 < 31 Hence safe

Shear reinforcementCalculation:
at Ends of Beam:
Required Shear capacity,Vs (refer concise report) = 4.00 Kip
Provided Shear capacity,Vn (refer concise report) = 24.00 Kip
Provided reinforcement As = #3 - 12 in = 0.11 in²/ft

4.00 < 24 Hence safe

At Interior of Beam:
Required Shear capacity,Vs (refer concise report) = 1.00 Kip
Provided Shear capacity,Vn (refer concise report) = 24.00 Kip
Provided reinforcement As = #3 - 12 in = 0.11 in²/ft

1 < 24 Hence safe

Provide #3 stirrups spacing @ 12" O.C for Full Length

Page 133of 248


BSL - LB-04 Lintel' Beam Design.con
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con Page 134of 248 Fri Mar 31 15:29:03 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

SUMMARY REPORT

Design Code Used: ACI 318-14

________________________________________________________________________________________________________________________

NON-DEFAULT OPTION SETTINGS

** ON ** P1: Vary user defined losses along beam


** ON ** F1: Check minimum strength at critical sections only
** OFF ** F7: Reduce φ in the development length of strands (CSA A23.3 only)
** OFF ** F8: Use a rectangular stress block at concrete ultimate strain
** ON ** F10: Use the cracking moment for minimum flexural strength (ACI and NZ codes for non-prestressed bea
** ON ** S1: Use the simplified shear method if applicable
** ON ** S2: Take the best of the detailed and simplified method
** ON ** S5: Use Zia/Hsu Method for torsion as per PCI Standard Practice guide (ACI Codes Only)
** ON ** S8: Calculate pre-tensioned bursting steel requirements
** ON ** S10: Use the ultimate section capacity for horizontal shear (moment region check)
** OFF ** D3: Have Concise Beam calculate long-term deflection multipliers for prestressed Beams

________________________________________________________________________________________________________________________

CONCRETE MATERIAL PROPERTIES

Precast Beam
Concrete Density, Wt 150 lb/ft^3
Compressive Strength, f'c 6000.0 psi
Flexural Modulus of Rupture, fr 581 psi
Modulus of Elasticity, Ec 4.696E+6 psi

PRECAST CONCRETE MIX, SCHEDULE, AND SERVICE ENVIRONMENT


(schedule from time of casting precast beam at 0 days)

Cement Content 691 lb/yd^3 Age at Stripping 2.00 days


Air Content 5.00 % Age at Erection 40 days
Slump 1.97 in Age at Cast-in-Place Pour 50 days
Aggregate Mix 0.40 fines/total Age Cast-in-Place is Composite 53 days
Aggregate Size 0.79 in Age Construction is Complete 143 days
Basic Shrinkage Strain 0.000780 in/in
Curing Method Moist Relative Humidity in Service 70 %
Concrete Hydration Rate Normal Ambient Temperature in Service 20 deg
Exposure in Service Inter

________________________________________________________________________________________________________________________

PRECAST BEAM LAYOUT


____________________________________________________________________________________________________________________
|Seg.| Segment Length | Section Identification | Offset |
| No.| From | To | Length | Folder | Section | Section | Z | Y |
| | ft | ft | ft | Name | Name | Type | in | in |
____________________________________________________________________________________________________________________
| 1| 0.000| 8.160| 8.160| B1 | LB-04- 2.45' | Solid Beam | 0.00| 0.00|
____________________________________________________________________________________________________________________

The cast-in-place pour, if defined, has been turned off (not included).

Warning: The span to depth ratio of the beam is less than 4 and could be classified as a deep beam.
Concise Beam uses simple beam theory which may not applicable to deep beams.

Span Length at Transfer = 8.160 ft, Centre of Supports, Left @ 0.000 ft, Right @ 8.160 ft
Span Length during Lift = 8.160 ft, Centre of Supports, Left @ 0.000 ft, Right @ 8.160 ft
Span Length in Service = 8.160 ft, Centre of Supports, Left @ 0.000 ft, Right @ 8.160 ft
Total Beam Length = 8.160 ft, Bearing Length, Left = 3.00 in, Right = 3.00 in

________________________________________________________________________________________________________________________

GROSS PRECAST SECTION PROPERTIES (NON-COMPOSITE)


(based on Ec of the precast beam - transformed area of rebar and strand NOT included)
____________________________________________________________________________________________________________
|Seg.| Section Properties | Section | Section | Shear | Volume /| Section Moduli |
| No.| A | I | yb | Height | Width | Width | Surface | Sb | St |
| | in^2 | in^4 | in | in | in | in | in | in^3 | in^3 |
____________________________________________________________________________________________________________
| 1| 118.0| 8557| 14.75| 29.50| 4.00| 4.00| 1.76| -580| 580|
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED SECTION PROPERTIES SUMMARY


____________________________________________________________________________________________________
| | Net Precast Section | Transformed Precast Section | Transformed Precast Section |
| | at Transfer (based on Eci) | at Transfer (based on Eci) | at 28 Days (based on Ec) |
| |(include rebar,deduct strand)| (include rebar and strand) | (include rebar and strand) |
| x | A | I | yb | A | I | yb | A | I | yb |
| ft | in^2 | in^4 | in | in^2 | in^4 | in | in^2 | in^4 | in |
____________________________________________________________________________________________________
| 0.000| 118.0| 8558| 14.75| 118.0| 8558| 14.75| 118.0| 8558| 14.75|
| 0.653| 120.4| 8858| 14.75| 120.4| 8858| 14.75| 119.7| 8777| 14.75|
| 1.387| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 2.203| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 3.019| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 3.754| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 3.998| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 4.325| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 4.570| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 5.141| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 5.957| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 6.691| 121.6| 9019| 14.76| 121.6| 9019| 14.76| 120.6| 8895| 14.76|
| 7.507| 120.4| 8858| 14.75| 120.4| 8858| 14.75| 119.7| 8777| 14.75|
| 8.160| 118.0| 8558| 14.75| 118.0| 8558| 14.75| 118.0| 8558| 14.75|
____________________________________________________________________________________________________
|These section properties can used to calculate uncracked concrete stresses using the following |
| guidelines. |
|- Net Precast Section at Transfer properties are used with the initial prestress after transfer |

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con 1 of 6 248
Page 135of Fri Mar 31 15:29:15 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

| (after elastic shortening loss). |


|- Transformed Precast Section at Transfer properties are used with the precast beam self-weight. |
|- Transformed Precast Section at 28 Days properties are used with external loads applied to the |
| non-composite precast beam. |
____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LONGITUDINAL REINFORCING STEEL


________________________________________________________________________________________________________________________
|ID| Qty | Steel | Bar | | Bar |End Location & Type| Bar | | Cross |Vertical| Offset ** |
| | | Grade | Size | | Area | From | | To | | Spacing| | Spacing| Offset | Reference |
| | | ksi |C=coated| | in^2 | ft | *| ft | *| in | | in | in | |
________________________________________________________________________________________________________________________
| 1| 1.000| 60.0| # 4 | | 0.200| 0.000|SE| 8.160|SE| 4.00| | - | 2.00| Bottom of Precast Beam |
| 2| 1.000| 60.0| # 4 | | 0.200| 0.000|SE| 8.160|SE| 4.00| | - | 2.00| Top of Precast Beam |
| 3| 1.000| 60.0| # 3 | | 0.110| 0.000|SE| 8.160|SE| 4.00| | - | 16.00| Bottom of Precast Beam |
________________________________________________________________________________________________________________________
|* Straight Embeddment (SE), Fully Developed (FD), Standard Hook (SH), Headed Bar (HB) |
|** Offsets are measured up from the bottom or down from the top |
|See the "Development Length" text report for details of the bar and wire development lengths |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR STIRRUPS
_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 8.160| 60.0| *| # 3 | 1| 0.11| 12.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

INTERFACE SHEAR TIES


_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 8.160| 60.0| *| # 3 | 1| 0.11| 12.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

________________________________________________________________________________________________________________________

APPLIED LOADS
____________________________________________________________________________________________________________________________
| Load Group | Stages Applied | Load Details ** |
| & Type | & Distribution | (left to right) |
____________________________________________________________________________________________________________________________
|Beam Weight(1) |Erection to Final Service |Segment #0: [V] 0.123 kip/ft full length |
| D: DL, Factory Produced |No Load Distribution | |
| | | |
|DL From Right side Truss |Final Service stage only |Truss - U13: [V] 1.05 kip @ 0.75 ft |
| D: DL, General |No Load Distribution |Truss - U29: [V] 0.61 kip @ 3.41 ft |
| | |Truss - U31: [V] 0.61 kip @ 6.08 ft |
| | | |
|LL From Right side Truss |Final Service stage only |Truss - U13: [V] 0.19 kip @ 0.75 ft |
| D: DL, General |No Load Distribution |Truss - U29: [V] 0.25 kip @ 3.41 ft |
| | |Truss - U31: [V] 0.19 kip @ 6.08 ft |
| | | |
____________________________________________________________________________________________________________________________
|* indicates load groups generated automatically by Concise Beam. |
|** [V] Vertical Load, [M] Moment, [T] Torsion. |
____________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LOAD COMBINATIONS

Serviceability (SLS) & Fatigue (FLS) Limit State Combinations (used individually)
SLS Stress : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S + 1.00Ws + 0.60Wu
SLS Deflect : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S
FLS Fatigue : 1.00P + 1.00D + 1.00F + 1.00L + 1.00L1 + 1.00Lr

Ultimate (Strength) Limit State (ULS) Combinations (searched collectively to obtain envelope)
1: ULS Combo 1 : 1.40D + 1.40F
2: ULS Combo 2 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50Lr
3: ULS Combo 3 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50S
4: ULS Combo 4 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50R
5: ULS Combo 5 : 1.20D + 0.50L + 1.00L1 + 1.60Lr
6: ULS Combo 6 : 1.20D + 0.50L + 1.00L1 + 1.60S
7: ULS Combo 7 : 1.20D + 0.50L + 1.00L1 + 1.60R
8: ULS Combo 8 : 1.20D + 1.60Lr + 0.80Ws + 0.50Wu
9: ULS Combo 9 : 1.20D + 1.60S + 0.80Ws + 0.50Wu
10: ULS Combo 10 : 1.20D + 1.60R + 0.80Ws + 0.50Wu
11: ULS Combo 11 : 1.20D + 0.50L + 1.00L1 + 0.50Lr + 1.60Ws + 1.00Wu
12: ULS Combo 12 : 1.20D + 0.50L + 1.00L1 + 0.50S + 1.60Ws + 1.00Wu
13: ULS Combo 13 : 1.20D + 0.50L + 1.00L1 + 0.50R + 1.60Ws + 1.00Wu
14: ULS Combo 14 : 1.20D + 0.50L + 1.00L1 + 0.20S + 1.40Es + 1.00Eu
15: ULS Combo 15 : 0.90D + 1.60L + 1.60L1 + 0.50Lr
16: ULS Combo 16 : 0.90D + 1.60Ws + 1.00Wu
17: ULS Combo 17 : 0.90D + 0.90F + 1.40Es + 1.00Eu

________________________________________________________________________________________________________________________

COMBINED ANALYSIS IN SERVICE - LOAD COMBINATION RESULTS


(external loads only)
______________________________________________________________________________________________________________
| Station| SLS (stress) Load Combination | ULS Load Envelopes |
| | Moment | Moment | Shear | Moment |
| x | Sustained | Total Load | Total Load |Govern.| Total Load |Govern.|

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con 2 of 6 248
Page 136of Fri Mar 31 15:29:15 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

| ft | kip.ft | kip.ft | kip | Combo.| kip.ft | Combo.|


| | | min | max | min | max |min|max| min | max |min|max|
______________________________________________________________________________________________________________
| 0.000| 0.00 | 0.00 | 0.00 | 2.10 | 3.26 | 15| 1| 0.00 | 0.00 | 1| 1|
| 0.653| 1.50 | 1.50 | 1.50 | 2.03 | 3.15 | 15| 1| 1.35 | 2.09 | 15| 1|
| 1.387| 2.33 | 2.33 | 2.33 | 0.83 | 1.29 | 15| 1| 2.09 | 3.26 | 15| 1|
| 2.203| 3.04 | 3.04 | 3.04 | 0.74 | 1.15 | 15| 1| 2.73 | 4.25 | 15| 1|
| 3.019| 3.67 | 3.67 | 3.67 | 0.65 | 1.01 | 15| 1| 3.30 | 5.13 | 15| 1|
| 3.754| 3.87 | 3.87 | 3.87 | -0.32 | -0.21 | 1| 15| 3.48 | 5.41 | 15| 1|
| 3.998| 3.81 | 3.81 | 3.81 | -0.36 | -0.23 | 1| 15| 3.43 | 5.33 | 15| 1|
| 4.325| 3.72 | 3.72 | 3.72 | -0.42 | -0.27 | 1| 15| 3.34 | 5.20 | 15| 1|
| 4.570| 3.64 | 3.64 | 3.64 | -0.46 | -0.30 | 1| 15| 3.28 | 5.10 | 15| 1|
| 5.141| 3.43 | 3.43 | 3.43 | -0.56 | -0.36 | 1| 15| 3.09 | 4.80 | 15| 1|
| 5.957| 3.06 | 3.06 | 3.06 | -0.70 | -0.45 | 1| 15| 2.76 | 4.29 | 15| 1|
| 6.691| 2.17 | 2.17 | 2.17 | -1.95 | -1.25 | 1| 15| 1.96 | 3.04 | 15| 1|
| 7.507| 1.00 | 1.00 | 1.00 | -2.09 | -1.34 | 1| 15| 0.90 | 1.40 | 15| 1|
| 8.160| 0.00 | 0.00 | 0.00 | -2.20 | -1.41 | 1| 15| 0.00 | 0.00 | 1| 1|
______________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SUPPORT REACTIONS DURING HANDLING


(+ve = upwards, counter-clockwise)
______________________________________________________________________
| | Initial Lifting | Erection Lifting |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical | Vertical |
| | kip | kip | kip | kip |
______________________________________________________________________
| Unfactored Load Group Effects |
| | | | | |
| Load Envelope Effects |
|SLS Minimum | 0.00 | 0.00 | 0.00 | 0.00 |
|SLS Maximum | 0.00 | 0.00 | 0.00 | 0.00 |
______________________________________________________________________

REACTIONS ON FINAL SUPPORTS


(+ve = upwards, counter-clockwise)
________________________________________________________________________________________________
| | During CIP Pour | In Service |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical[*]| Torsion[*] | Vertical[*]| Torsion[*] |
| | kip | kip | kip | kip.ft | kip | kip.ft |
________________________________________________________________________________________________
| Unfactored Load Group Effects |
|Beam Weight(1) | 0.50 | 0.50 | 0.50 | 0.00 | 0.50 | 0.00 |
|DL From Right si| | | 1.46 | 0.00 | 0.81 | 0.00 |
|LL From Right si| | | 0.37 | 0.00 | 0.26 | 0.00 |
| | | | | | | |
| Load Envelope Effects |
|SLS DL | | | 2.33 | 0.00 | 1.57 | 0.00 |
|SLS Sustain | | | 2.33 | 0.00 | 1.57 | 0.00 |
|SLS Minimum | 0.50 | 0.50 | 2.33 | 0.00 | 1.57 | 0.00 |
|SLS Maximum | 0.50 | 0.50 | 2.33 | 0.00 | 1.57 | 0.00 |
|ULS Minimum | | | 2.10 [15]| 0.00 [ 1]| 1.41 [15]| 0.00 [ 1]|
|ULS Maximum | | | 3.26 [ 1]| 0.00 [ 1]| 2.20 [ 1]| 0.00 [ 1]|
________________________________________________________________________________________________
|* Governing ULS Load Combination (below) |
________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED CONCRETE STRESS RESULTS


(+ve = compression, -ve = tension)
____________________________________________________________________________________________________________
| | x | Stress | Limit * | |
| Location | ft | psi | psi | |
____________________________________________________________________________________________________________
|STRESSES DURING INITIAL LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 2100| |
| Bottom of Beam | 0.000| 0| 2100| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -444| |
| Bottom of Beam | 0.000| 0| -444| |
____________________________________________________________________________________________________________
|STRESSES DURING ERECTION LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| |
| Bottom of Beam | 0.000| 0| -581| |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE | |
|Critical Compression | |
| Top of Beam | 3.410| 78| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| Not cracked |
| Bottom of Beam | 3.410| -78| -581| Not cracked |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE (SUSTAINED LOADS ONLY) | |
|Critical Compression | |
| Top of Beam | 3.410| 78| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
____________________________________________________________________________________________________________
|* Tensile stress limit shown for the precast beam is the flexural cracking strength for comparison only. |
| Crack control is required. |
|* Compression limit shown is 0.6 times the compressive strength for comparison only. |
|** See the detailed Uncracked Stress reports for full extent of tensile reinforcing required to control |
| cracking during transfer and handling. |

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con 3 of 6 248
Page 137of Fri Mar 31 15:29:15 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

CRACK CONTROL STEEL AND SPACING


(+ve = compression, -ve = tension)
___________________________________________________________________________________________________________________________
| | Bottom | Top of | |
| | of Beam | Beam | |
___________________________________________________________________________________________________________________________
| kb | 1.00| 0.00| | Adjustment coefficient for prestressing steel |
| cc | 1.75| 0.00|in | Clear concrete cover to steel closest to tension face |
| fs | -40.0| 0.0|ksi | Steel stress nearest to tension face after decompression |
| Max spacing | 10.62| 0.00|in | Maximum centre/centre spacing of steel closest to tension face |
___________________________________________________________________________________________________________________________

Beam not cracked, cracking controlled, or crack depth less than concrete cover.

________________________________________________________________________________________________________________________

DEFLECTION ESTIMATE AT ALL STAGES


_____________________________________________________________________________________________________________
| | Net Deflection | Change in Deflection| Span/Deflection Ratio |
|Location| Net @ | Net @ | Net Sust.| Net Total| Sustained| LL | Net Total| Sustained| LL |
| x | Erection |Completion| @ Final | @ Final | Growth+LL| alone |Deflection| Growth+LL| alone |
| ft | in | in | in | in | in | in | | | |
| Column | B | C | D | E | E - C | E - D | L/E * | L/(E-C) *| L/(E-D) |
_____________________________________________________________________________________________________________
| 0.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
| 0.653| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 120641 | 147310 | 0 |
| 1.387| 0.000 | 0.000 | -0.002 | -0.002 | -0.001 | 0.000 | 59796 | 73169 | 0 |
| 2.203| 0.000 | 0.000 | -0.002 | -0.002 | -0.002 | 0.000 | 41120 | 50402 | 0 |
| 3.019| 0.000 | 0.000 | -0.003 | -0.003 | -0.002 | 0.000 | 33899 | 41592 | 0 |
| 3.754| 0.000 | 0.000 | -0.003 | -0.003 | -0.003 | 0.000 | 31559 | 38758 | 0 |
| 3.998| 0.000 | 0.000 | -0.003 | -0.003 | -0.003 | 0.000 | 31387 | 38563 | 0 |
| 4.325| 0.000 | 0.000 | -0.003 | -0.003 | -0.003 | 0.000 | 31579 | 38818 | 0 |
| 4.570| 0.000 | 0.000 | -0.003 | -0.003 | -0.002 | 0.000 | 32040 | 39399 | 0 |
| 5.141| 0.000 | 0.000 | -0.003 | -0.003 | -0.002 | 0.000 | 34316 | 42221 | 0 |
| 5.957| 0.000 | 0.000 | -0.002 | -0.002 | -0.002 | 0.000 | 41867 | 51530 | 0 |
| 6.691| 0.000 | 0.000 | -0.002 | -0.002 | -0.001 | 0.000 | 58484 | 72031 | 0 |
| 7.507| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 125868 | 155178 | 0 |
| 8.160| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
_____________________________________________________________________________________________________________
| Col. B |Net deflection at erection includes all dead loads applied before the cast-in-place pour plus |
| | long-time deflection growth of the beam weight up to erection. |
| Col. C |Net deflection at completion of construction includes all dead loads plus long-time deflection |
| | growth of the dead load up to completion. |
| Col. D |Net sustained deflection at final includes all dead loads, and sustained live loads, plus |
| | long-time deflection growth. |
| Col. E |Net total deflection at final includes all dead loads, and all live loads, plus long-time |
| | deflection growth. |
| Note |Sustained deflection or growth includes dead loads and sustained live loads. |
| * |Span/deflection ratio is maximized with or without the inclusion of live load. |
_____________________________________________________________________________________________________________

Span/Deflection Limits: Sustained Load Growth + LL = L / 480 for non-structural attachments


Sustained Load Growth + LL = L / 240 otherwise
LL alone = L / 360 for floors *
LL alone = L / 180 for roofs *
* See the Vibration Check in Service report for more specific vibration guidelines

________________________________________________________________________________________________________________________

UNRESTRAINED SUPPORT ROTATIONS AT ALL STAGES


(+ve = clockwise rotation)
________________________________________________________________________________________
| | Net Rotation | Change in Rotation |
| Support| Net @ | Net @ | Net DL | Net Total | DL growth | LL |
|Location| Erection | Completion | @ Final | @ Final | + LL | alone |
| | degrees | degrees | degrees | degrees | degrees | degrees |
| Column | B | C | D | E | E - C | E - D |
________________________________________________________________________________________
| Left| 549.991E-6 | 0.0011 | 0.0060 | 0.0060 | 0.0049 | 0.0000 |
| Right|-549.990E-6 | -0.0011 | -0.0058 | -0.0058 | -0.0047 | 0.0000 |
________________________________________________________________________________________

UNRESTRAINED LONGITUDINAL CHANGE OF LENGTH DUE TO CREEP AND SHRINKAGE


(-ve = shortening, +ve = elongation)
__________________________________________________________________________________________________
| | Total Change of Length | Difference in Change |
| | Erection | Composite|Completion| Final | | to Compl.| to Final | to Final |
| | in | in | in | in | | in | in | in |
| | B | | C | D | | C - B | D - C | D - B |
__________________________________________________________________________________________________
| Creep| 0.0000| 0.0000| 0.0000| 0.0000| | 0.0000| 0.0000| 0.0000|
| Shrink.| -0.0269| -0.0305| -0.0407| -0.0529| | -0.0137| -0.0122| -0.0259|
| Total| -0.0269| -0.0305| -0.0407| -0.0529| | -0.0137| -0.0122| -0.0259|
__________________________________________________________________________________________________

Elastic Shortening = 0.0000 in

________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

FLEXURAL DESIGN CHECK IN FINAL SERVICE


________________________________________________________________________________________________________________________
| | Design | Cracking | Minimum * | Design | Depth in | Net Tensile| Flexural | Ø | Warnings |
| | Moment | Moment | Flexural | Strength | Compression| Strain |Classication| | & Notes |
| x | Mu | Mcr | Strength | ØMn | c | | | | |
| ft | kip.ft | kip.ft | kip.ft | kip.ft | in | | | | |
________________________________________________________________________________________________________________________
| 0.000| 0.00| 28.09| 0.00| 0.03| 4.05| 0.0000| Tension | 0.90| 3 |
| 0.653| 2.09| 28.80| 2.79| 16.88| 4.12| 0.0014| Tension | 0.90| 3 |
| 1.387| 3.26| 29.18| 4.34| 31.12| 1.54| 0.0507| Tension | 0.90| |

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con 4 of 6 248
Page 138of Fri Mar 31 15:29:15 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

| 2.203| 4.25| 29.18| 5.67| 31.12| 1.54| 0.0507| Tension | 0.90| |


| 3.019| 5.13| 29.18| 6.84| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 3.754| 5.41| 29.18| 7.22| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 3.998| 5.33| 29.18| 7.11| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 4.325| 5.20| 29.18| 6.94| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 4.570| 5.10| 29.18| 6.79| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 5.141| 4.80| 29.18| 6.41| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 5.957| 4.29| 29.18| 5.72| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 6.691| 3.04| 29.18| 4.06| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 7.507| 1.40| 28.80| 1.87| 16.88| 4.12| 0.0014| Tension | 0.90| 3 |
| 8.160| 0.00| 28.09| 0.00| 0.03| 4.05| 0.0000| Tension | 0.90| 3 |
| |
________________________________________________________________________________________________________________________
|Points of Maximum and Minimum Factored Moment |
| 3.410| 5.51| 29.18| 7.35| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 0.000| 0.00| 28.09| 0.00| -0.03| 4.15| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Factored Moment to Design Strength |
| 3.410| 5.51| 29.18| 7.35| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 0.000| 0.00| 28.09| 0.00| -0.03| 4.15| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Minimum Strength to Design Strength |
| 3.410| 5.51| 29.18| 7.35| 31.12| 1.54| 0.0507| Tension | 0.90| |
| 0.000| 0.00| 28.09| 0.00| -0.03| 4.15| 0.0000| Tension | 0.90| 3 |
________________________________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design strength is based on a reduced maximum concrete strain to avoid steel slippage or rupture. See |
| | Flexural Design Detail Report and Help file's Technical Background for more information. |
| * |Minimum Flexural Strength is 1.2 Mcr or 4/3 Mu [ACI 318-14::9.6/Option F10] |
|ØMn(As,min) is the factored flexural strength based on the minimum required area for tensile steel required by the |
| selected code. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods (Option G3). |
|See the Flexural Design Details text report for more details. |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR DESIGN CHECK IN FINAL SERVICE


_____________________________________________________________________________________________________
| | Design | Vertical | Concrete | Required | Strength Provided | Warnings |
| | Shear | Prestress| Strength | Stirrups | Stirrups | Total | & Notes |
| x | Vu | Vp | ØVc | ØVs | ØVs | ØVn | |
| ft | kip | kip | kip | kip | kip | kip | |
_____________________________________________________________________________________________________
| 0.000| 3.24| 0.00| 12.78| 0.00| 11.34| 24.12| 3 5 |
| 0.653| 3.15| 0.00| 12.78| 0.00| 11.34| 24.12| 5 |
| 1.387| 1.29| 0.00| 12.78| 0.00| 11.34| 24.12| 5 |
| 2.203| 1.15| 0.00| 12.78| 0.00| 11.34| 24.12| 5 |
| 3.019| 1.01| 0.00| 12.78| 0.00| 11.34| 24.12| 5 |
| 3.754| -0.32| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 3.998| -0.36| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 4.325| -0.42| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 4.570| -0.46| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 5.141| -0.56| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 5.957| -0.70| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 6.691| -1.95| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 7.507| -2.09| 0.00| -12.78| 0.00| -11.34| -24.12| 5 |
| 8.160| -2.18| 0.00| -12.78| 0.00| -11.34| -24.12| 3 5 |
_____________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design shear force at critical section near support used [ACI 318-14::7.4.3.2/9.4.3.2]. |
|Note [5]|Calculation of the shear strength of the concrete used the simplified method [ACI |
| | 318-14::22.5.5.1/22.5.8.2]. |
| Note |The PCI recommended Zia/Hsu method was used to calculate the above shear design check |
| | results [PCI Handbbok 8th ed. section 5.4.1]. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods |
| | (Option G3). |
|See the Shear Design Check Details text report for more details. |
_____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR TRANSVERSE REINFORCING DESIGN CHECK IN FINAL SERVICE


_________________________________________________________________________________________________
| |Shear Steel|Shear Steel|Shear Steel| Stirrup | Stirrup Spacing | Warnings |
| | Grade | Required | Provided | Provided | Provided | Max. Allow| & Notes |
| x | fy | Av/s | Av/s | Av | s | s | |
| ft | ksi | in^2/ft | in^2/ft | in^2 | in | in | |
_________________________________________________________________________________________________
| 0.000| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| 4 |
| 0.653| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 1.387| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 2.203| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 3.019| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 3.754| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 3.998| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 4.325| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 4.570| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 5.141| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 5.957| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 6.691| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 7.507| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 8.160| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| 4 |
_________________________________________________________________________________________________
|Warnings & Notes |
|Note [4]|Design shear force at critical section near support used [ACI |
| | 318-14::7.4.3.2/9.4.3.2]. |
| Note |Shear steel requirements for pre-tension bursting have been included (calculation |
| | option S8). |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical |
| | methods (calculation option G3). |
| * |Portion of the total stirrup area required to resist torsional shear flow (one leg |
| | around periphery). |
| ** |Allowable reduction within flexural compression zone [ACI 318-14::9.5.4.5]. Limited to|
| | half the Total and Al minimum. |
|See the Shear Design Check Details text report for more details. |
_________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con 5 of 6 248
Page 139of Fri Mar 31 15:29:15 2023
Flexure Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

Flexure Check - Final Service


(ACI 318-14)
40.00

35.00

30.00

25.00
Moment - kip.ft

20.00

15.00

10.00

5.00

0.00

-5.00

-10.00

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Design Moment, Mu: +ve Bending
Min. Strength Required: +ve Bending
Design Strength, ØMn: +ve Bending

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con Page 140of 248 Fri Mar 31 15:29:26 2023
Shear Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

Shear Check - Final Service


(ACI 318-14)
35.00

28.00

21.00

14.00

7.00
Shear - kip

0.00

-7.00

-14.00

-21.00

-28.00

-35.00

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Design Shear, Vu
Total Strength Provided, ØVn
Concrete Strength Provided, ØVc
Critical Section for Shear Loading

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con Page 141of 248 Fri Mar 31 15:29:34 2023
Deflection - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

Deflection - Final Service


(ACI 318-14)
0.001

0.000

0.000

0.000
Deflection - in

-0.001

-0.002

-0.002

-0.003

-0.003

-0.004

-0.004

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Deflection @ Erection
Deflection On Completion
Final Service Sustained Deflection
Final Service Sust. + LL Deflection

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con Page 142of 248 Fri Mar 31 15:29:43 2023
Deflection Limits - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

Deflection Limits - Final Service


(ACI 318-14)
1.000

0.800

0.600

0.400
Deflection - in

0.200

0.000

-0.200

-0.400

-0.600

-0.800

-1.000

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Sustained Load Growth + Live Load
Sust.+LL Maximum Limit (L/240)
Sust.+LL Non-Structural Limit (L/480)
Live Load Only
LL Limit for Roofs (L/180)
LL Limit for Floors (L/360)

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con Page 143of 248 Fri Mar 31 15:29:50 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

Concrete Stress (beam) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con Page 144of 248 Fri Mar 31 15:30:00 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-04

Concrete Stress (Sust) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - LB-04 Lintel' Beam Design.con Page 145of 248 Fri Mar 31 15:30:07 2023
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST LINTEL BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Level-2 Precast Lintel beam Design: TYPE LB-05

Material property data:


Grade of concrete = 6000 Psi
Grade of steel = 60 Ksi
Density of concrete = 0.15 Kip/ft³

Beam Geometry data:


Length of beam = 8.16 ft
Width of beam = 0.33 ft (4" Interior Wythe is Considered as
Depth of beam = 1.64 ft Structural Wythe in Concise Software)
Thickness of screed = 0 ft
Beam support condtion = SSD

Beam Loading:
Self weight of beam = 0.33x1.64x0.150 = 0.081 Kip/ft

DESIGN LOADS:

Roof truss load on Beam:

P1: Load from Right side Roof:

Dead Load (Refer truss design) (U10 - Truss) = 0.73 Kip


(U11 - Truss) = 0.73 Kip
(U12 - Truss) = 0.73 Kip

Live Load (Refer truss design) (U10 - Truss) = 0.63 Kip


(U11 - Truss) = 0.63 Kip
(U12 - Truss) = 0.63 Kip

Total dead load on beam = 2.184 Kip


Total live load on beam = 1.902 Kip

Page 146of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST LINTEL BEAM DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Loading Diagram:

Reinforcement design :
Bottom Tension reinforcement at span
Required moment capacity,Mu (refer concise report) = 8 Kip-ft
Provided Moment capacity,Mn (refer concise report) = 21 Kip-ft

8 < 21 Hence safe

Shear reinforcementCalculation:
at Ends of Beam:
Required Shear capacity,Vs (refer concise report) = 4.00 Kip
Provided Shear capacity,Vn (refer concise report) = 15.00 Kip
Provided reinforcement As = #3 - 12 in = 0.11 in²/ft

4.00 < 15 Hence safe

At Interior of Beam:
Required Shear capacity,Vs (refer concise report) = 1.00 Kip
Provided Shear capacity,Vn (refer concise report) = 15.00 Kip
Provided reinforcement As = #3 - 12 in = 0.11 in²/ft

1 < 15 Hence safe

Provide #3 stirrups spacing @ 12" O.C for Full Length

Page 147of 248


BSL - LB-05 Lintel' Beam Design.con
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con Page 148of 248 Fri Mar 31 15:30:48 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

SUMMARY REPORT

Design Code Used: ACI 318-14

________________________________________________________________________________________________________________________

NON-DEFAULT OPTION SETTINGS

** ON ** P1: Vary user defined losses along beam


** ON ** F1: Check minimum strength at critical sections only
** OFF ** F7: Reduce φ in the development length of strands (CSA A23.3 only)
** OFF ** F8: Use a rectangular stress block at concrete ultimate strain
** ON ** F10: Use the cracking moment for minimum flexural strength (ACI and NZ codes for non-prestressed bea
** ON ** S1: Use the simplified shear method if applicable
** ON ** S2: Take the best of the detailed and simplified method
** ON ** S5: Use Zia/Hsu Method for torsion as per PCI Standard Practice guide (ACI Codes Only)
** ON ** S8: Calculate pre-tensioned bursting steel requirements
** ON ** S10: Use the ultimate section capacity for horizontal shear (moment region check)
** OFF ** D3: Have Concise Beam calculate long-term deflection multipliers for prestressed Beams

________________________________________________________________________________________________________________________

CONCRETE MATERIAL PROPERTIES

Precast Beam
Concrete Density, Wt 150 lb/ft^3
Compressive Strength, f'c 6000.0 psi
Flexural Modulus of Rupture, fr 581 psi
Modulus of Elasticity, Ec 4.696E+6 psi

PRECAST CONCRETE MIX, SCHEDULE, AND SERVICE ENVIRONMENT


(schedule from time of casting precast beam at 0 days)

Cement Content 691 lb/yd^3 Age at Stripping 2.00 days


Air Content 5.00 % Age at Erection 40 days
Slump 1.97 in Age at Cast-in-Place Pour 50 days
Aggregate Mix 0.40 fines/total Age Cast-in-Place is Composite 53 days
Aggregate Size 0.79 in Age Construction is Complete 143 days
Basic Shrinkage Strain 0.000780 in/in
Curing Method Moist Relative Humidity in Service 70 %
Concrete Hydration Rate Normal Ambient Temperature in Service 20 deg
Exposure in Service Inter

________________________________________________________________________________________________________________________

PRECAST BEAM LAYOUT


____________________________________________________________________________________________________________________
|Seg.| Segment Length | Section Identification | Offset |
| No.| From | To | Length | Folder | Section | Section | Z | Y |
| | ft | ft | ft | Name | Name | Type | in | in |
____________________________________________________________________________________________________________________
| 1| 0.000| 8.160| 8.160| B1 | LB-05- 1.64' | Solid Beam | 0.00| 0.00|
____________________________________________________________________________________________________________________

The cast-in-place pour, if defined, has been turned off (not included).

Span Length at Transfer = 8.160 ft, Centre of Supports, Left @ 0.000 ft, Right @ 8.160 ft
Span Length during Lift = 8.160 ft, Centre of Supports, Left @ 0.000 ft, Right @ 8.160 ft
Span Length in Service = 8.160 ft, Centre of Supports, Left @ 0.000 ft, Right @ 8.160 ft
Total Beam Length = 8.160 ft, Bearing Length, Left = 3.00 in, Right = 3.00 in

________________________________________________________________________________________________________________________

GROSS PRECAST SECTION PROPERTIES (NON-COMPOSITE)


(based on Ec of the precast beam - transformed area of rebar and strand NOT included)
____________________________________________________________________________________________________________
|Seg.| Section Properties | Section | Section | Shear | Volume /| Section Moduli |
| No.| A | I | yb | Height | Width | Width | Surface | Sb | St |
| | in^2 | in^4 | in | in | in | in | in | in^3 | in^3 |
____________________________________________________________________________________________________________
| 1| 78.7| 2541| 9.84| 19.68| 4.00| 4.00| 1.66| -258| 258|
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED SECTION PROPERTIES SUMMARY


____________________________________________________________________________________________________
| | Net Precast Section | Transformed Precast Section | Transformed Precast Section |
| | at Transfer (based on Eci) | at Transfer (based on Eci) | at 28 Days (based on Ec) |
| |(include rebar,deduct strand)| (include rebar and strand) | (include rebar and strand) |
| x | A | I | yb | A | I | yb | A | I | yb |
| ft | in^2 | in^4 | in | in^2 | in^4 | in | in^2 | in^4 | in |
____________________________________________________________________________________________________
| 0.000| 78.7| 2541| 9.84| 78.7| 2541| 9.84| 78.7| 2541| 9.84|
| 0.653| 81.1| 2654| 9.84| 81.1| 2654| 9.84| 80.4| 2623| 9.84|
| 1.469| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 2.203| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 3.019| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 3.835| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 4.080| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 4.325| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 4.570| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 5.141| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 5.957| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 6.773| 82.3| 2715| 9.84| 82.3| 2715| 9.84| 81.4| 2668| 9.84|
| 7.507| 81.1| 2654| 9.84| 81.1| 2654| 9.84| 80.4| 2623| 9.84|
| 8.160| 78.7| 2541| 9.84| 78.7| 2541| 9.84| 78.7| 2541| 9.84|
____________________________________________________________________________________________________
|These section properties can used to calculate uncracked concrete stresses using the following |
| guidelines. |
|- Net Precast Section at Transfer properties are used with the initial prestress after transfer |
| (after elastic shortening loss). |
|- Transformed Precast Section at Transfer properties are used with the precast beam self-weight. |
|- Transformed Precast Section at 28 Days properties are used with external loads applied to the |

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con 1 of 6 248
Page 149of Fri Mar 31 15:31:00 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

| non-composite precast beam. |


____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LONGITUDINAL REINFORCING STEEL


________________________________________________________________________________________________________________________
|ID| Qty | Steel | Bar | | Bar |End Location & Type| Bar | | Cross |Vertical| Offset ** |
| | | Grade | Size | | Area | From | | To | | Spacing| | Spacing| Offset | Reference |
| | | ksi |C=coated| | in^2 | ft | *| ft | *| in | | in | in | |
________________________________________________________________________________________________________________________
| 1| 1.000| 60.0| # 4 | | 0.200| 0.000|SE| 8.160|SE| 4.00| | - | 2.00| Bottom of Precast Beam |
| 2| 1.000| 60.0| # 4 | | 0.200| 0.000|SE| 8.160|SE| 4.00| | - | 2.00| Top of Precast Beam |
| 3| 1.000| 60.0| # 3 | | 0.110| 0.000|SE| 8.160|SE| 4.00| | - | 10.00| Bottom of Precast Beam |
________________________________________________________________________________________________________________________
|* Straight Embeddment (SE), Fully Developed (FD), Standard Hook (SH), Headed Bar (HB) |
|** Offsets are measured up from the bottom or down from the top |
|See the "Development Length" text report for details of the bar and wire development lengths |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR STIRRUPS
_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 8.160| 60.0| *| # 3 | 1| 0.11| 12.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

INTERFACE SHEAR TIES


_______________________________________________________________________________
| From | To | Grade | | Size | # of Legs|Total Area| Spacing |
| ft | ft | ksi | | | | in^2 | in |
_______________________________________________________________________________
| 0.000| 8.160| 60.0| *| # 3 | 1| 0.11| 12.00|
_______________________________________________________________________________
|* Useable steel strength limited by selected code. |
_______________________________________________________________________________

________________________________________________________________________________________________________________________

APPLIED LOADS
____________________________________________________________________________________________________________________________
| Load Group | Stages Applied | Load Details ** |
| & Type | & Distribution | (left to right) |
____________________________________________________________________________________________________________________________
|Beam Weight(1) |Erection to Final Service |Segment #0: [V] 0.082 kip/ft full length |
| D: DL, Factory Produced |No Load Distribution | |
| | | |
|DL From Right side Truss |Final Service stage only |Truss - U10: [V] 0.73 kip @ 1.5 ft |
| D: DL, General |No Load Distribution |Truss - U11: [V] 0.73 kip @ 4.16 ft |
| | |Truss - U12: [V] 0.73 kip @ 6.83 ft |
| | | |
|LL From Right side Truss |Final Service stage only |Truss - U10: [V] 0.63 kip @ 1.5 ft |
| D: DL, General |No Load Distribution |Truss - U11: [V] 0.63 kip @ 4.16 ft |
| | |Truss - U12: [V] 0.63 kip @ 6.83 ft |
| | | |
____________________________________________________________________________________________________________________________
|* indicates load groups generated automatically by Concise Beam. |
|** [V] Vertical Load, [M] Moment, [T] Torsion. |
____________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

LOAD COMBINATIONS

Serviceability (SLS) & Fatigue (FLS) Limit State Combinations (used individually)
SLS Stress : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S + 1.00Ws + 0.60Wu
SLS Deflect : 1.00P + 1.00D + 1.00F + 1.00T + 1.00L + 1.00L1 + 1.00Lr + 1.00R + 1.00S
FLS Fatigue : 1.00P + 1.00D + 1.00F + 1.00L + 1.00L1 + 1.00Lr

Ultimate (Strength) Limit State (ULS) Combinations (searched collectively to obtain envelope)
1: ULS Combo 1 : 1.40D + 1.40F
2: ULS Combo 2 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50Lr
3: ULS Combo 3 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50S
4: ULS Combo 4 : 1.20D + 1.20F + 1.20T + 1.60L + 1.60L1 + 0.50R
5: ULS Combo 5 : 1.20D + 0.50L + 1.00L1 + 1.60Lr
6: ULS Combo 6 : 1.20D + 0.50L + 1.00L1 + 1.60S
7: ULS Combo 7 : 1.20D + 0.50L + 1.00L1 + 1.60R
8: ULS Combo 8 : 1.20D + 1.60Lr + 0.80Ws + 0.50Wu
9: ULS Combo 9 : 1.20D + 1.60S + 0.80Ws + 0.50Wu
10: ULS Combo 10 : 1.20D + 1.60R + 0.80Ws + 0.50Wu
11: ULS Combo 11 : 1.20D + 0.50L + 1.00L1 + 0.50Lr + 1.60Ws + 1.00Wu
12: ULS Combo 12 : 1.20D + 0.50L + 1.00L1 + 0.50S + 1.60Ws + 1.00Wu
13: ULS Combo 13 : 1.20D + 0.50L + 1.00L1 + 0.50R + 1.60Ws + 1.00Wu
14: ULS Combo 14 : 1.20D + 0.50L + 1.00L1 + 0.20S + 1.40Es + 1.00Eu
15: ULS Combo 15 : 0.90D + 1.60L + 1.60L1 + 0.50Lr
16: ULS Combo 16 : 0.90D + 1.60Ws + 1.00Wu
17: ULS Combo 17 : 0.90D + 0.90F + 1.40Es + 1.00Eu

________________________________________________________________________________________________________________________

COMBINED ANALYSIS IN SERVICE - LOAD COMBINATION RESULTS


(external loads only)
______________________________________________________________________________________________________________
| Station| SLS (stress) Load Combination | ULS Load Envelopes |
| | Moment | Moment | Shear | Moment |
| x | Sustained | Total Load | Total Load |Govern.| Total Load |Govern.|
| ft | kip.ft | kip.ft | kip | Combo.| kip.ft | Combo.|
| | | min | max | min | max |min|max| min | max |min|max|
______________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con 2 of 6 248
Page 150of Fri Mar 31 15:31:00 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

| 0.000| 0.00 | 0.00 | 0.00 | 2.10 | 3.27 | 15| 1| 0.00 | 0.00 | 1| 1|


| 0.653| 1.51 | 1.51 | 1.51 | 2.05 | 3.19 | 15| 1| 1.35 | 2.11 | 15| 1|
| 1.469| 3.34 | 3.34 | 3.34 | 1.99 | 3.10 | 15| 1| 3.00 | 4.67 | 15| 1|
| 2.203| 3.98 | 3.98 | 3.98 | 0.71 | 1.11 | 15| 1| 3.59 | 5.58 | 15| 1|
| 3.019| 4.60 | 4.60 | 4.60 | 0.65 | 1.02 | 15| 1| 4.14 | 6.45 | 15| 1|
| 3.835| 5.17 | 5.17 | 5.17 | 0.59 | 0.92 | 15| 1| 4.65 | 7.24 | 15| 1|
| 4.080| 5.33 | 5.33 | 5.33 | 0.57 | 0.89 | 15| 1| 4.79 | 7.46 | 15| 1|
| 4.325| 5.26 | 5.26 | 5.26 | -1.04 | -0.67 | 1| 15| 4.73 | 7.36 | 15| 1|
| 4.570| 5.07 | 5.07 | 5.07 | -1.07 | -0.69 | 1| 15| 4.57 | 7.10 | 15| 1|
| 5.141| 4.62 | 4.62 | 4.62 | -1.13 | -0.73 | 1| 15| 4.16 | 6.47 | 15| 1|
| 5.957| 3.94 | 3.94 | 3.94 | -1.23 | -0.79 | 1| 15| 3.54 | 5.51 | 15| 1|
| 6.773| 3.20 | 3.20 | 3.20 | -1.32 | -0.85 | 1| 15| 2.88 | 4.47 | 15| 1|
| 7.507| 1.56 | 1.56 | 1.56 | -3.31 | -2.13 | 1| 15| 1.40 | 2.18 | 15| 1|
| 8.160| 0.00 | 0.00 | 0.00 | -3.38 | -2.17 | 1| 15| 0.00 | 0.00 | 1| 1|
______________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SUPPORT REACTIONS DURING HANDLING


(+ve = upwards, counter-clockwise)
______________________________________________________________________
| | Initial Lifting | Erection Lifting |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical | Vertical |
| | kip | kip | kip | kip |
______________________________________________________________________
| Unfactored Load Group Effects |
| | | | | |
| Load Envelope Effects |
|SLS Minimum | 0.00 | 0.00 | 0.00 | 0.00 |
|SLS Maximum | 0.00 | 0.00 | 0.00 | 0.00 |
______________________________________________________________________

REACTIONS ON FINAL SUPPORTS


(+ve = upwards, counter-clockwise)
________________________________________________________________________________________________
| | During CIP Pour | In Service |
| Load Group | Left | Right | Left | Right |
| or Envelope | Vertical | Vertical | Vertical[*]| Torsion[*] | Vertical[*]| Torsion[*] |
| | kip | kip | kip | kip.ft | kip | kip.ft |
________________________________________________________________________________________________
| Unfactored Load Group Effects |
|Beam Weight(1) | 0.33 | 0.33 | 0.33 | 0.00 | 0.33 | 0.00 |
|DL From Right si| | | 1.07 | 0.00 | 1.12 | 0.00 |
|LL From Right si| | | 0.93 | 0.00 | 0.96 | 0.00 |
| | | | | | | |
| Load Envelope Effects |
|SLS DL | | | 2.33 | 0.00 | 2.42 | 0.00 |
|SLS Sustain | | | 2.33 | 0.00 | 2.42 | 0.00 |
|SLS Minimum | 0.33 | 0.33 | 2.33 | 0.00 | 2.42 | 0.00 |
|SLS Maximum | 0.33 | 0.33 | 2.33 | 0.00 | 2.42 | 0.00 |
|ULS Minimum | | | 2.10 [15]| 0.00 [ 1]| 2.17 [15]| 0.00 [ 1]|
|ULS Maximum | | | 3.27 [ 1]| 0.00 [ 1]| 3.38 [ 1]| 0.00 [ 1]|
________________________________________________________________________________________________
|* Governing ULS Load Combination (below) |
________________________________________________________________________________________________

________________________________________________________________________________________________________________________

UNCRACKED CONCRETE STRESS RESULTS


(+ve = compression, -ve = tension)
____________________________________________________________________________________________________________
| | x | Stress | Limit * | |
| Location | ft | psi | psi | |
____________________________________________________________________________________________________________
|STRESSES DURING INITIAL LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 2100| |
| Bottom of Beam | 0.000| 0| 2100| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -444| |
| Bottom of Beam | 0.000| 0| -444| |
____________________________________________________________________________________________________________
|STRESSES DURING ERECTION LIFTING | |
|Critical Compression | |
| Top of Beam | 0.000| 0| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| |
| Bottom of Beam | 0.000| 0| -581| |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE | |
|Critical Compression | |
| Top of Beam | 4.160| 238| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
| | |
|Critical Tension | |
| Top of Beam | 0.000| 0| -581| Not cracked |
| Bottom of Beam | 4.160| -238| -581| Not cracked |
____________________________________________________________________________________________________________
|STRESSES IN SERVICE (SUSTAINED LOADS ONLY) | |
|Critical Compression | |
| Top of Beam | 4.160| 238| 3600| |
| Bottom of Beam | 0.000| 0| 3600| |
____________________________________________________________________________________________________________
|* Tensile stress limit shown for the precast beam is the flexural cracking strength for comparison only. |
| Crack control is required. |
|* Compression limit shown is 0.6 times the compressive strength for comparison only. |
|** See the detailed Uncracked Stress reports for full extent of tensile reinforcing required to control |
| cracking during transfer and handling. |
____________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con 3 of 6 248
Page 151of Fri Mar 31 15:31:00 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

CRACK CONTROL STEEL AND SPACING


(+ve = compression, -ve = tension)
___________________________________________________________________________________________________________________________
| | Bottom | Top of | |
| | of Beam | Beam | |
___________________________________________________________________________________________________________________________
| kb | 1.00| 0.00| | Adjustment coefficient for prestressing steel |
| cc | 1.75| 0.00|in | Clear concrete cover to steel closest to tension face |
| fs | -17.3| 0.0|ksi | Steel stress nearest to tension face after decompression |
| Max spacing | 27.74| 0.00|in | Maximum centre/centre spacing of steel closest to tension face |
___________________________________________________________________________________________________________________________

Beam not cracked, cracking controlled, or crack depth less than concrete cover.

________________________________________________________________________________________________________________________

DEFLECTION ESTIMATE AT ALL STAGES


_____________________________________________________________________________________________________________
| | Net Deflection | Change in Deflection| Span/Deflection Ratio |
|Location| Net @ | Net @ | Net Sust.| Net Total| Sustained| LL | Net Total| Sustained| LL |
| x | Erection |Completion| @ Final | @ Final | Growth+LL| alone |Deflection| Growth+LL| alone |
| ft | in | in | in | in | in | in | | | |
| Column | B | C | D | E | E - C | E - D | L/E * | L/(E-C) *| L/(E-D) |
_____________________________________________________________________________________________________________
| 0.000| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
| 0.653| 0.000 | 0.000 | -0.003 | -0.003 | -0.003 | 0.000 | 28569 | 31508 | 0 |
| 1.469| 0.000 | 0.000 | -0.007 | -0.007 | -0.007 | 0.000 | 13344 | 14718 | 0 |
| 2.203| 0.000 | 0.000 | -0.010 | -0.010 | -0.009 | 0.000 | 9618 | 10613 | 0 |
| 3.019| 0.000 | -0.001 | -0.012 | -0.012 | -0.011 | 0.000 | 7911 | 8731 | 0 |
| 3.835| 0.000 | -0.001 | -0.013 | -0.013 | -0.012 | 0.000 | 7301 | 8057 | 0 |
| 4.080| 0.000 | -0.001 | -0.013 | -0.013 | -0.012 | 0.000 | 7267 | 8019 | 0 |
| 4.325| 0.000 | -0.001 | -0.013 | -0.013 | -0.012 | 0.000 | 7299 | 8055 | 0 |
| 4.570| 0.000 | -0.001 | -0.013 | -0.013 | -0.012 | 0.000 | 7397 | 8163 | 0 |
| 5.141| 0.000 | -0.001 | -0.012 | -0.012 | -0.011 | 0.000 | 7910 | 8729 | 0 |
| 5.957| 0.000 | 0.000 | -0.010 | -0.010 | -0.009 | 0.000 | 9622 | 10618 | 0 |
| 6.773| 0.000 | 0.000 | -0.007 | -0.007 | -0.006 | 0.000 | 14030 | 15474 | 0 |
| 7.507| 0.000 | 0.000 | -0.003 | -0.003 | -0.003 | 0.000 | 28519 | 31447 | 0 |
| 8.160| 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0 | 0 | 0 |
_____________________________________________________________________________________________________________
| Col. B |Net deflection at erection includes all dead loads applied before the cast-in-place pour plus |
| | long-time deflection growth of the beam weight up to erection. |
| Col. C |Net deflection at completion of construction includes all dead loads plus long-time deflection |
| | growth of the dead load up to completion. |
| Col. D |Net sustained deflection at final includes all dead loads, and sustained live loads, plus |
| | long-time deflection growth. |
| Col. E |Net total deflection at final includes all dead loads, and all live loads, plus long-time |
| | deflection growth. |
| Note |Sustained deflection or growth includes dead loads and sustained live loads. |
| * |Span/deflection ratio is maximized with or without the inclusion of live load. |
_____________________________________________________________________________________________________________

Span/Deflection Limits: Sustained Load Growth + LL = L / 480 for non-structural attachments


Sustained Load Growth + LL = L / 240 otherwise
LL alone = L / 360 for floors *
LL alone = L / 180 for roofs *
* See the Vibration Check in Service report for more specific vibration guidelines

________________________________________________________________________________________________________________________

UNRESTRAINED SUPPORT ROTATIONS AT ALL STAGES


(+ve = clockwise rotation)
________________________________________________________________________________________
| | Net Rotation | Change in Rotation |
| Support| Net @ | Net @ | Net DL | Net Total | DL growth | LL |
|Location| Erection | Completion | @ Final | @ Final | + LL | alone |
| | degrees | degrees | degrees | degrees | degrees | degrees |
| Column | B | C | D | E | E - C | E - D |
________________________________________________________________________________________
| Left| 0.0012 | 0.0024 | 0.0254 | 0.0254 | 0.0230 | 0.0000 |
| Right| -0.0012 | -0.0024 | -0.0254 | -0.0254 | -0.0231 | 0.0000 |
________________________________________________________________________________________

UNRESTRAINED LONGITUDINAL CHANGE OF LENGTH DUE TO CREEP AND SHRINKAGE


(-ve = shortening, +ve = elongation)
__________________________________________________________________________________________________
| | Total Change of Length | Difference in Change |
| | Erection | Composite|Completion| Final | | to Compl.| to Final | to Final |
| | in | in | in | in | | in | in | in |
| | B | | C | D | | C - B | D - C | D - B |
__________________________________________________________________________________________________
| Creep| 0.0000| 0.0000| 0.0000| 0.0000| | 0.0000| 0.0000| 0.0000|
| Shrink.| -0.0278| -0.0314| -0.0415| -0.0534| | -0.0137| -0.0119| -0.0256|
| Total| -0.0278| -0.0314| -0.0415| -0.0534| | -0.0137| -0.0119| -0.0256|
__________________________________________________________________________________________________

Elastic Shortening = 0.0000 in

________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

FLEXURAL DESIGN CHECK IN FINAL SERVICE


________________________________________________________________________________________________________________________
| | Design | Cracking | Minimum * | Design | Depth in | Net Tensile| Flexural | Ø | Warnings |
| | Moment | Moment | Flexural | Strength | Compression| Strain |Classication| | & Notes |
| x | Mu | Mcr | Strength | ØMn | c | | | | |
| ft | kip.ft | kip.ft | kip.ft | kip.ft | in | | | | |
________________________________________________________________________________________________________________________
| 0.000| 0.00| 12.50| 0.00| 0.02| 3.22| 0.0000| Tension | 0.90| 3 |
| 0.653| 2.11| 12.91| 2.81| 10.92| 3.29| 0.0014| Tension | 0.90| 3 |
| 1.469| 4.67| 13.12| 6.23| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 2.203| 5.58| 13.12| 7.44| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 3.019| 6.45| 13.12| 8.59| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 3.835| 7.24| 13.12| 9.65| 20.39| 1.54| 0.0315| Tension | 0.90| |

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con 4 of 6 248
Page 152of Fri Mar 31 15:31:00 2023
Summary Report

Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.


Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

| 4.080| 7.46| 13.12| 9.94| 20.39| 1.54| 0.0315| Tension | 0.90| |


| 4.325| 7.36| 13.12| 9.81| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 4.570| 7.10| 13.12| 9.47| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 5.141| 6.47| 13.12| 8.63| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 5.957| 5.51| 13.12| 7.35| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 6.773| 4.47| 13.12| 5.96| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 7.507| 2.18| 12.91| 2.91| 10.92| 3.29| 0.0014| Tension | 0.90| 3 |
| 8.160| 0.00| 12.50| 0.00| 0.02| 3.22| 0.0000| Tension | 0.90| 3 |
| |
________________________________________________________________________________________________________________________
|Points of Maximum and Minimum Factored Moment |
| 4.160| 7.53| 13.12| 10.04| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 0.000| 0.00| 12.50| 0.00| -0.02| 3.23| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Factored Moment to Design Strength |
| 4.160| 7.53| 13.12| 10.04| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 0.000| 0.00| 12.50| 0.00| -0.02| 3.23| 0.0000| Tension | 0.90| 3 |
|Points of Maximum Ratio of Minimum Strength to Design Strength |
| 4.160| 7.53| 13.12| 10.04| 20.39| 1.54| 0.0315| Tension | 0.90| |
| 0.000| 0.00| 12.50| 0.00| -0.02| 3.23| 0.0000| Tension | 0.90| 3 |
________________________________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design strength is based on a reduced maximum concrete strain to avoid steel slippage or rupture. See |
| | Flexural Design Detail Report and Help file's Technical Background for more information. |
| * |Minimum Flexural Strength is 1.2 Mcr or 4/3 Mu [ACI 318-14::9.6/Option F10] |
|ØMn(As,min) is the factored flexural strength based on the minimum required area for tensile steel required by the |
| selected code. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods (Option G3). |
|See the Flexural Design Details text report for more details. |
________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR DESIGN CHECK IN FINAL SERVICE


_____________________________________________________________________________________________________
| | Design | Vertical | Concrete | Required | Strength Provided | Warnings |
| | Shear | Prestress| Strength | Stirrups | Stirrups | Total | & Notes |
| x | Vu | Vp | ØVc | ØVs | ØVs | ØVn | |
| ft | kip | kip | kip | kip | kip | kip | |
_____________________________________________________________________________________________________
| 0.000| 3.25| 0.00| 8.22| 0.00| 7.29| 15.51| 3 5 |
| 0.653| 3.19| 0.00| 8.22| 0.00| 7.29| 15.51| 5 |
| 1.469| 3.10| 0.00| 8.22| 0.00| 7.29| 15.51| 5 |
| 2.203| 1.11| 0.00| 8.22| 0.00| 7.29| 15.51| 5 |
| 3.019| 1.02| 0.00| 8.22| 0.00| 7.29| 15.51| 5 |
| 3.835| 0.92| 0.00| 8.22| 0.00| 7.29| 15.51| 5 |
| 4.080| 0.89| 0.00| 8.22| 0.00| 7.29| 15.51| 5 |
| 4.325| -1.04| 0.00| -8.22| 0.00| -7.29| -15.51| 5 |
| 4.570| -1.07| 0.00| -8.22| 0.00| -7.29| -15.51| 5 |
| 5.141| -1.13| 0.00| -8.22| 0.00| -7.29| -15.51| 5 |
| 5.957| -1.23| 0.00| -8.22| 0.00| -7.29| -15.51| 5 |
| 6.773| -1.32| 0.00| -8.22| 0.00| -7.29| -15.51| 5 |
| 7.507| -3.31| 0.00| -8.22| 0.00| -7.29| -15.51| 5 |
| 8.160| -3.37| 0.00| -8.22| 0.00| -7.29| -15.51| 3 5 |
_____________________________________________________________________________________________________
|Warnings & Notes |
|Note [3]|Design shear force at critical section near support used [ACI 318-14::7.4.3.2/9.4.3.2]. |
|Note [5]|Calculation of the shear strength of the concrete used the simplified method [ACI |
| | 318-14::22.5.5.1/22.5.8.2]. |
| Note |The PCI recommended Zia/Hsu method was used to calculate the above shear design check |
| | results [PCI Handbbok 8th ed. section 5.4.1]. |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical methods |
| | (Option G3). |
|See the Shear Design Check Details text report for more details. |
_____________________________________________________________________________________________________

________________________________________________________________________________________________________________________

SHEAR TRANSVERSE REINFORCING DESIGN CHECK IN FINAL SERVICE


_________________________________________________________________________________________________
| |Shear Steel|Shear Steel|Shear Steel| Stirrup | Stirrup Spacing | Warnings |
| | Grade | Required | Provided | Provided | Provided | Max. Allow| & Notes |
| x | fy | Av/s | Av/s | Av | s | s | |
| ft | ksi | in^2/ft | in^2/ft | in^2 | in | in | |
_________________________________________________________________________________________________
| 0.000| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| 4 |
| 0.653| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 1.469| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 2.203| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 3.019| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 3.835| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 4.080| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 4.325| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 4.570| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 5.141| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 5.957| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 6.773| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 7.507| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| |
| 8.160| 60.0| 0.000| 0.110| 0.110| 12.00| 0.00| 4 |
_________________________________________________________________________________________________
|Warnings & Notes |
|Note [4]|Design shear force at critical section near support used [ACI |
| | 318-14::7.4.3.2/9.4.3.2]. |
| Note |Shear steel requirements for pre-tension bursting have been included (calculation |
| | option S8). |
| Note |A 1% overstress is allowed without a warning to allow for accuracy of numerical |
| | methods (calculation option G3). |
| * |Portion of the total stirrup area required to resist torsional shear flow (one leg |
| | around periphery). |
| ** |Allowable reduction within flexural compression zone [ACI 318-14::9.5.4.5]. Limited to|
| | half the Total and Al minimum. |
|See the Shear Design Check Details text report for more details. |
_________________________________________________________________________________________________

________________________________________________________________________________________________________________________

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con 5 of 6 248
Page 153of Fri Mar 31 15:31:00 2023
Flexure Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

Flexure Check - Final Service


(ACI 318-14)
24.00

21.00

18.00

15.00
Moment - kip.ft

12.00

9.00

6.00

3.00

0.00

-3.00

-6.00

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Design Moment, Mu: +ve Bending
Min. Strength Required: +ve Bending
Design Strength, ØMn: +ve Bending

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con Page 154of 248 Fri Mar 31 15:31:08 2023
Shear Check - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

Shear Check - Final Service


(ACI 318-14)
20.00

16.00

12.00

8.00

4.00
Shear - kip

0.00

-4.00

-8.00

-12.00

-16.00

-20.00

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Design Shear, Vu
Total Strength Provided, ØVn
Concrete Strength Provided, ØVc
Critical Section for Shear Loading

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con Page 155of 248 Fri Mar 31 15:31:15 2023
Deflection - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

Deflection - Final Service


(ACI 318-14)
0.004

0.002

0.000

-0.002
Deflection - in

-0.004

-0.006

-0.008

-0.010

-0.012

-0.014

-0.016

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Deflection @ Erection
Deflection On Completion
Final Service Sustained Deflection
Final Service Sust. + LL Deflection

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con Page 156of 248 Fri Mar 31 15:31:43 2023
Deflection Limits - Final Service Graph
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

Deflection Limits - Final Service


(ACI 318-14)
1.000

0.800

0.600

0.400
Deflection - in

0.200

0.000

-0.200

-0.400

-0.600

-0.800

-1.000

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Sustained Load Growth + Live Load
Sust.+LL Maximum Limit (L/240)
Sust.+LL Non-Structural Limit (L/480)
Live Load Only
LL Limit for Roofs (L/180)
LL Limit for Floors (L/360)

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con Page 157of 248 Fri Mar 31 15:31:50 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

Concrete Stress (beam) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con Page 158of 248 Fri Mar 31 15:32:00 2023
Concrete Stress
Concise Beam 4.65b, Copyright 2002-2022 Black Mint Software, Inc.
Licensed to: DEFAULT - EVALUATION USE ONLY
Project: BURNT STORE LAKES
Problem: LB-05

Concrete Stress (Sust) - Final Service


(ACI 318-14)
4800

4200

3600
Stress (compression +ve) - psi

3000

2400

1800

1200

600

-600

-1200

0.000 0.816 1.632 2.448 3.264 4.080 4.896 5.712 6.528 7.344 8.160

Distance From Left End of Beam - ft


Maximum Stress at Top of Beam
Minimum Stress at Top of Beam
Maximum Stress at Bottom of Beam
Minimum Stress at Bottom of Beam
0.6f'c in Compression
Tensile Strength of Concrete

Engineer: NK Company: ONX


File: BSL - LB-05 Lintel' Beam Design.con Page 159of 248 Fri Mar 31 15:32:08 2023
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST WALL DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter H

Precast Wall design

Page 160of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : WALL DESIGN LAYOUT
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Precast Wall design Run layout

Note: - *Without highlighted beam is checked but not included in the package and it will available upon request

Page 161of 248


PLF STRUCTURAL ENGINEERS, INC.
CA #30758 PROJECT : BURNT STORE LAKES
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314.
TITLE : PRECAST WALL DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

DESIGN FOR 8" THICK VERTICAL PRECAST SANDWICH WALLPANEL DESIGN TYPE
A Run1
Design Notes:

* Wallpanel is located near grid "7" and b/w Grids "A & B" @ South Elevation.
* Critical Wallpanel is designed for Roof Truss load and C&C Wind Loads.
* Assume the Wall panel is pinned at Roof deck Level.
* Design will be valid for 8" Thick Sandwich WP.
* 29" Critical width of panel is considered as design section Conservatively.
* 4" Interior Wythe is designed as Load bearing for Vertical Load ( DL + Live) and Wind load on conservative side
Ignoring composite behaviour of the section (also a separate calculation is attached For composite action for
reference).
Design section is considered as 8" x 29"

DESIGN LOADS:

Roof truss load on Wallpanel:

P1: Load from Right side Roof: \

Dead Load (Refer Lintel beam design concise - B1) = 6 Kip

Live Load (Refer Lintel beam design concise - B1) = 3.24 Kip

Total dead load on Wall = 6.000 Kip


Total live load on Wall = 3.24 Kip

Wind Loads on Wallpanel: (Walls)

Wind acting on exposed width = 2.50 ft (at Level-2)

(P2) Components & Cladding Wind (Pressure) = 64.40 psf (Refer Wind Load Calculation Sheets)

(For an exposed area of 22.90 Sq. Ft) = 2.50' x 9.16' = 22.90 sq.ft
(Postive Zone 4 & 5)
Wind Pressure at the areas exposed in plf = 64.40 psf x 2.50' = 161.0 plf

(P3) Components & Cladding Wind (Suction) = 83.90 psf (Refer Wind Load Calculation Sheets)

(For an
(For
exposed
an exposed
area area
of 167.01
of 22.90
Sq. Sq.
Ft) Ft) = 2.50' x 9.16' = 22.90 sq.ft
(Negative Zone 5)
Wind Pressure at the areas exposed in plf = 83.90 psf x 2.50' = 209.8 plf

Page 162of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : PRECAST WALL DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Loading diagram

Load Units: kips & in-kips Wind Load Units: plf

P1 P2 Pressure 161.0 plf


WALLS
DL 6.0 P3 Suction 209.8 plf
Mx -
Mz -
LL 3.2
Mx -
Mz -
SL -
Mx -
Mz -
Vu 12.4
Vudl 7.2

Load Combinations:

According to ASCE 7-16 - Section 2.3.1

1) 1.4 DL
2) 1.2 DL + 1.6 LL GOVERNS
3) 1.2 DL + 1.0 WL(Pressure) + 1.0LL
4) 1.2 DL + 1.0 WL(Suction) + 1.0LL
5) 0.9 DL + 1.0 WL (Pressure)
6) 0.9 DL + 1.0 WL (Suction)

Page 163of 248


Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Project Information
Project: BURNT STORE LAKES Location: Project Location Date: 3/17/2023
Client: ONX Designer: Job No.:
Description: Design Type A-Run1 Spec: ACI 318-14
Material Properties
Concrete
Top Wythe
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0

In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight


Bottom Wythe
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0
In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight

Rebar Mesh Strand


fy (ksi) 60 - fpu (ksi) -
Es (ksi) 29000 - Ep (ksi) -
Exterior Soil Interior Soil
Design contains no exterior soil loads Design contains no interior soil loads
Load Combinations
Strength Combinations Service Combinations
# D L R W E T H Include # D L R W E T H Include
1 1.4 0 0 0 0 0 0 1 1 0 0 0 0 0 0
2 1.2 1.6 0 0 0 0 0 2 1 1 0 0 0 0 0
3 1.2 1 0 0 0 0 0 3 1 0 0 0 0 0 0
4 1.2 0 0 0.5 0 0 0 4 1 0.75 0 0 0 0 0
5 1.2 1 0 1 0 0 0 5 1 0 0 0.6 0 0 0
6 1.2 1 0 0 0 0 0 6 1 0 0 0 0 0 0
7 0.9 0 0 1 0 0 0 7 1 0.75 0 0.45 0 0 0
8 0.9 0 0 0 0 0 0 8 1 0.75 0 0 0 0 0
9 0.6 0 0 0.6 0 0 0
10 0.6 0 0 0 0 0 0
Settings
Deflection Limits Stress Options Resistance Factors
Add initial bow to reported deflections Failure if cracked Developed Transfering
Tension 0.9 0.75
Additional Bow: 0" Ignore Lateral Strand Eccentricity
Compression 0.65 -
Total Deflection Limit: L / 150
Use Principal Axis Shear 0.75 -
Elastic Analysis
2nd Order Effects: P-Delta
In Place Stress Limits Development Multipliers
Analysis βd : Non-Sway Modulus of Rupture (psi): 7.5 √fc Strand (Normal): 1

R-Value Calculation Compression: 0.6 fc Strand (Debonded): 2


Handling Stress Limits Strand (Cut): 1
Concrete Resistance (k): 13.33
Tension: 7.5 √fc
Insulation Resistance (k): 0.238 Mild: 1
Compression: 0.6 fc Shear Options
Interior Resistance (R): 0.68
Flexure Options Treat as column
Exterior Resistance (R): 0.17 Method: Whitney Stress Block
Cracking Check: None Axial Options
Bottom Length Ignored: 0"
Ignore tensile strength failures
Top Length Ignored: 0"
Ignore buckling failures

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 1


Page 164of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Concrete Extents
Panel Geometry
Top Elevation : 9'-2" Insulation Thickness : 2"
Bottom Elevation : 0" Top Wythe
Height : 9'-2" Width : 2'-5" Thickness : 4"
Bottom Wythe
Section Type : Sandwich Panel
Width : 2'-5" Thickness : 2"
Top in Form : Interior
Top End Block : 0"
Bottom End Block : 0"

Left Miter Right Miter


Left miter not included in design Top In Form
Width : 0" Height : 0"
Openings, Reveals, and Solid Zones
Wall design contains no openings, reveals, or solid zones.

8" 2'-5"

Area, in²: 174.00


Width, in: 29.00
Height, in: 8.00
Cx, in: 14.50
Cy, in: 4.33
9'-2"

9'-2"

Izz, in⁴: 1140.67


Iyy, in⁴: 12194.50
Izy, in⁴: 0.00
Sb, in³: 263.23
St, in³: 311.09

0.200L
1'-10"

Side Elevation Front Elevation Section Properties


2'-5"
4"

8"
2" 2"

Cross Section

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 2


Page 165of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Structural Model
Restraints Releases
Add foundation connection Restrain Moment:
Design contains no releases.

Add floor tie


ID Elevation Type Gravity Rest. Thermal Rest. Stiffness (k/in)
1 0" Restrained -
2 9'-2" Restrained -

9.17 ft

Concentrated Loads Load Options


Load Components (k / kip-ft) Pattern Live Loads for Flexure
ID Elevation Ecc Dead Live Roof Pres. Suct. Seis.
↓ 6 3.29 0 0 0 0
P1 9'-2.0" 0.0"
→ 0 0 0 0 0 0 Selfweight eccentricity: 0"
Eccentricity measured from: Panel CG
Wind Loads
Start End
ID Type Start Mag. End Mag.
from Bot from Top
W1 Pressure 161 plf 161 plf
0" 0"
W2 Suction 209.8 plf 209.8 plf

Seismic Loads
Zone Location(s): Full height
Apply multipliers to Deadload + Self weight
Start of Zone (x/L) End of Zone (x/L) Seismic Load (Cs, % of DL)
0.00 1.00 0.0

Temperature Loads Interior Soil Loads Exterior Soil Loads Additional Self Weight
Exterior Temperature (F°): 105 Elevation: 0" Elevation: 0" Start from Bottom: 0"
Interior Temperature (F°): 75 Surcharge (psf): 0 Surcharge (psf): 0 End from Top: 0"
Thermal Elasticity Multiplier: 1 Magnitude (plf): 0
Exterior

W1

P1

W2

Interior
Structural Sections
No structural sections defined, using entire cross section.

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 3


Page 166of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Reinforcement
Strands
Design contains no prestressing
Rebar
Depth to Loc. from Start from End from Start End
Size Area Diameter Quantity Spacing
CG Left Bottom Top Condition Condition
#3 0.11 0.375" 1 1'-10" 7" 1'-1.5" 1" 1" Straight Straight
#3 0.11 0.375" 1 1'-10" 7" 1'-4.5" 1" 1" Straight Straight
#4 0.2 0.5" 3 11" 2" 3.5" 1" 1" Straight Straight
Mesh
Design contains no mesh
Interrupts
Design contains no interrupts

2'-5"

2'-5"

2"

7"
6"

1"
1'-1½" 3" 1'-0½" (2) #3

3½" 11" 11" 3½" (3) #4

0.500L
9'-2"

4'-7"
Strand Mild
Aps, in²: 0.00 As, in²: 0.82
cgx, in: 0.00 cgx, in: 14.63
cgy, in: 0.00 cgy, in: 4.66
ex, in: 0.00
ey, in: 0.00

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 4


Page 167of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

PROJECT: LOCATION: JOB NO.:


BURNT STORE LAKES Project Location

CLIENT: ENGINEER: CHECKER: DATE:


ONX Checker 03/17/23

DESIGN THICKNESS 8"


DESIGN WIDTH 2'-5"
DESIGN HEIGHT 9'-2"

2'-5"
2"

7"

8"
6"

1"

1'-1½" 3" 1'-0½" (2) #3 x 9'-0"

3½" 11" 11" 3½" (3) #4 x 9'-0"

Section View (0.50L - 4'-7")

CONCRETE MIX: CONCRETE AT RELEASE (f'ci): CONCRETE AT 28 DAYS (f'c): CONCRETE DENSITY:
Standard Mix 3500 psi 6000 psi 150 pcf
PRIMARY TOP REINFORCEMENT: (3) #4 x 9'-0"

PRIMARY BOT REINFORCEMENT: (2) #3 x 9'-0"

1'-11" 5'-4" 1'-11"


6"

1'-11" 5'-4" 1'-11"


1'-5"
6"

STRIPPING & BLOCKING DETAIL


STRIP WITH: REVISION: DESIGN NUMBER:

Strip
ERECT WITH: 1
Erection

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 5


Page 168of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Loading Summary
Concentrated Load Summary
ID Type Dir Ecc, in Description
Dc Vert. -6.000 k at 9.17 ft 0.000
L Vert. -3.290 k at 9.17 ft 0.000

Distributed Load Summary


ID Type Dir Description
Wp Horz. -0.161 k / ft at 0.00 ft to -0.161 k / ft at 9.17 ft
Ws Horz. 0.210 k / ft at 0.00 ft to 0.210 k / ft at 9.17 ft
SW Vert. -0.181 k / ft at 0.00 ft to -0.181 k / ft at 9.17 ft Self Weight

Point Moment Summary


Design contains no point moments

Load Patterns Summary


ID Wind Soil Loads Seismic Loads Live Loads
All Left Right L-R R-L
Pressure Suction External Internal Positive Negative
Alternate Alternate
1 ✓ - - - - - ✓ - - - -
2 - ✓ - - - - ✓ - - - -

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 6


Page 169of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Project Information Panel Properties


Project: BURNT STORE LAKES Location: Project Location Date: 03/17/23 f'ci: 3.5 ksi f'c: 6.0 ksi Δlim: 0.73 in
Client: ONX Designer: Job #: Δ T: 30.0 F° Initial Bow: 0.0 in Δ Max: 0.06/-0.04 in
Description: Design Type A-Run1
Specification: ACI 318-14, PCI Design Handbook 8ᵗʰ Edition

Loading [ ID - Load Case - Direction - Magnitude (k / plf) ] Ultimate Reactions (Elevation, Magnitude (k), Direction)
Dy 6.0 Ly 3.29 W1 Wp 161.0 W2 Ws 209.8 0" 0.99 → 0" 14.46 ↓ 0" 0.76 ←
9'-2" 0.99 → 9'-2" 0.76 ←

Stripping Interaction Diagram (Controlling Section @ 0.50L / 55 in)


Face Inserts: Qty: 4 Shear: 0.3 k Tension: 0.6 k

700
Shear Utilization: 0.07 (0.7 k / 10.3 k) Max Comp.: 26 psi / 2100 psi
Flexure Utilization: 0.05 (0.4 k-ft / 9.7 k-ft) Max Tension: 24 psi / 444 psi

600
Transportation

200 300 400 500


Shear Utilization: 0.05 (0.7 k / 13.5 k) Max Comp.: 28 psi / 3600 psi
Flexure Utilization: 0.05 (0.5 k-ft / 10.1 k-ft) Max Tension: 26 psi / 581 psi

Axial Capacity (k)


Stage: Erection
Face Inserts: Qty: 4 Shear: 0.3 k Tension: 0.6 k
Edge Inserts: Qty: 2 Shear: 0.0 k Tension: 1163.0 k
Shear Utilization: 0.05 (0.7 k / 13.5 k) Max Comp.: 26 psi / 3600 psi
Flexure Utilization: 0.04 (0.4 k-ft / 10.1 k-ft) Max Tension: 24 psi / 581 psi
100

Stage: In-Place
0

Shear LC: LC 5 - 1.2D + 1.0L + 1.0W


Flexure LC: LC 7 - 0.9D + 1.0W
-100

Shear Utilization: 0.07 (-1.0 k / -13.5 k) Max Comp.: 269 psi / 3600 psi
Flexure Utilization: 0.38 (-2.3 k-ft / -6.0 k-ft) Max Tension: 173 psi / 581 psi -30 -20 -10 0 10 20 30
Axial Utilization: 0.05 (14.4 k/ 316.2 k) Moment Capacity (k-ft)

2'-5"
P1

9'-2"
W1

W2

0.4 0.2 0.0 300 150 0 200 100 0


Flexure Utilization Comp. Stress Tension Stress
Structural Model Front Elevation - Not to Scale (Mu/ϕMn) (psi) (psi)

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 7


Page 170of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

1 Design Parameters
1.1 Composite Section Properties
Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ
(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
0.92 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
1.83 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
2.75 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
3.67 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
4.58 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
5.50 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
6.42 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
7.33 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
8.25 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
9.17 29.00 8.00 174.00 14.50 3.67 1141 12195 13335 0.00 0.00
1.2 Non-composite Section Properties
Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ
(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
0.92 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
1.83 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
2.75 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
3.67 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
4.58 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
5.50 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
6.42 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
7.33 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
8.25 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00
9.17 29.00 4.00 116.00 14.50 2.00 155 8130 8284 0.00 0.00

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 8


Page 171of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Detailed Flexure Capacity


Load Combination : All Combinations

Location : 4.58' (0.500 L) - LC 7 - Controlling

0% Composite Capacity

Y
X

Cross Section
Capacity Parameters Flexure Parameters Concrete Properties
Utilization : 0.378 Pu : 6.148 k Section f'c Ec λ wc
ϕMnx : -5.959 k-ft Mx : -2.252 k-ft (psi) (ksi) (pcf)
ϕPn, Compression : 324.761 k INT 6000.0 4696.0 1.00 150.0
εcu : 0.003 in/in
EXT 6000.0 4696.0 1.00 150.0
ϕPn, Tension : -32.400 k c : 0.386 in
Rebar Properties
Pcrit : 207.351 k θ : -180.000 deg
ϕ : 0.900 Height : 8.000 in
fy : 60.0 ksi Es : 29000.0 ksi
ϕTension : 0.900 CGx : 14.500 in Mesh Properties
ϕCompression : 0.650 CGy : 3.667 in fy : ksi Es : ksi
Strand Properties
Section does not contain any strand.
Concrete Force
Method: Whitney Stress Block
β : 0.750
a : 0.290 in
Section Comp. Area Cx Cy Force
(in²) (in) (in) (k)
INT 8.398 14.500 0.145 -42.831
EXT 0.000 0.000
8.398 14.500 0.145 -42.831
Mild Tension Force

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 9


Page 172of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Area Stress
# X Y Base Developed Effective Strain Base Concrete Total Force Mxi Myi
(in) (in) (in²) (%) (in²) (10⁻³) (ksi) (ksi) (ksi) (k) (k-ft) (k-ft)
1 15.500 7.000 0.110 100.00 0.110 51.387 60.000 0.000 60.000 6.600 -1.833 0.550
2 12.500 7.000 0.110 100.00 0.110 51.387 60.000 0.000 60.000 6.600 -1.833 -1.100
3 25.500 2.000 0.200 100.00 0.200 12.539 60.000 0.000 60.000 12.000 1.667 11.000
4 14.500 2.000 0.200 100.00 0.200 12.539 60.000 0.000 60.000 12.000 1.667 0.000
5 3.500 2.000 0.200 100.00 0.200 12.539 60.000 0.000 60.000 12.000 1.667 -11.000
14.366 3.341 0.820 100.00 0.820 60.000 0.000 60.000 49.200 1.333 -0.550
Mild Compression Force
Sections contains no mild reinforcement in compression
Prestressed Reinforcement Force
Design contains to prestressed reinforcement
Resistance Factor Axial Capacity Convergence Check
εmax : 51.387 10⁻³ in/in ϕ : 0.900 Ag : 174.00 in² Pu /ϕ : -6.831 k

Flexure Capacity Astr : 0.820 in² Fconc : -42.831 k


Apt : 0.000 in² Fmild : 49.200 k
x Axis
fse : 0.00 ksi Fstrand : 0.000 k
Mconc : -12.570 k-ft ϕPn Comp : 324.761 k Total : 13.200 k
Mmild : 1.333 k-ft ϕPn Tens : 32.400 k
Mstrand : 0.000 k-ft
Plain Concrete Strength
Mnx : -11.237 k-ft ϕMnx : 1.647 k-ft

ϕMnx : -10.113 k-ft

ϕMn vs ϕPn
Mn vs Pn
700

Demand ⬤
600
500 400
Axial Capacity (k)
200 300
100
0
-100

-30 -20 -10 0 10 20 30


Moment Capacity (k-ft)
PM Diagram
(Loading angle fixed at 180.00 deg)

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 10


Page 173of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

2.1 In-Place Strength Summary


All Combinations
2.1.1 Reaction Forces
Out-of-plane
Location Towards Interior Towards Exterior
0" 0.99 k 0.76 k
9'-2" 0.99 k 0.76 k
2.1.2 Flexure
2.1.2.1 Summary Table
Loc. Util. Mu Φ ΦMn Mcr Pu ΦPn c θ As A's Aps Loss d
(ft) (k-ft) (k-ft) (k-ft) (k) (k) (in) (deg) (in²) (in²) (in²) (%) (in)
0.00 0.00 0.0 0.65 1.7 4.2 10.7 307.6 0.15 0.0 0.00 0.00 0.00 0.00 0.00
0.46 0.14 -0.4 0.90 -3.0 -1.3 6.8 316.2 0.19 180.0 0.31 0.00 0.00 0.00 3.34
0.92 0.15 -0.8 0.90 -5.3 -1.3 6.7 324.8 0.34 180.0 0.68 0.00 0.00 0.00 3.34
1.37 0.19 -1.1 0.90 -6.0 -1.3 6.7 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
1.83 0.24 -1.4 0.90 -6.0 -1.3 6.6 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
2.29 0.28 -1.7 0.90 -6.0 -1.3 6.5 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
2.75 0.32 -1.9 0.90 -6.0 -1.3 6.4 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
3.21 0.34 -2.0 0.90 -6.0 -1.3 6.4 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
3.67 0.36 -2.2 0.90 -6.0 -1.3 6.3 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
4.12 0.37 -2.2 0.90 -6.0 -1.3 6.2 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
4.58 0.38 -2.3 0.90 -6.0 -1.3 6.1 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
5.04 0.37 -2.2 0.90 -5.9 -1.3 6.1 324.8 0.39 180.0 0.82 0.00 0.00 0.00 3.34
5.50 0.36 -2.2 0.90 -5.9 -1.3 6.0 324.8 0.38 180.0 0.82 0.00 0.00 0.00 3.34
5.96 0.35 -2.0 0.90 -5.9 -1.3 5.9 324.8 0.38 180.0 0.82 0.00 0.00 0.00 3.34
6.42 0.32 -1.9 0.90 -5.9 -1.3 5.8 324.8 0.38 180.0 0.82 0.00 0.00 0.00 3.34
6.87 0.29 -1.7 0.90 -5.9 -1.3 5.8 324.8 0.38 180.0 0.82 0.00 0.00 0.00 3.34
7.33 0.24 -1.4 0.90 -5.9 -1.3 5.7 324.8 0.38 180.0 0.82 0.00 0.00 0.00 3.34
7.79 0.19 -1.1 0.90 -5.9 -1.3 5.6 324.8 0.38 180.0 0.82 0.00 0.00 0.00 3.34
8.25 0.16 -0.8 0.90 -5.1 -1.3 5.5 324.8 0.33 180.0 0.68 0.00 0.00 0.00 3.34
8.71 0.15 -0.4 0.90 -2.8 -1.3 5.5 316.2 0.18 180.0 0.31 0.00 0.00 0.00 3.34
9.17 0.00 0.0 0.65 1.4 4.2 8.4 307.6 0.12 0.0 0.00 0.00 0.00 0.00 0.00
2.1.3 Shear
2.1.3.1 Summary Table
Loc. Util Vu ϕVn Vc Vs Req b wd Av Min
(ft) (k) (k) (k) (k) (in²) (in²/ft)
0.00 0.07 -1.0 13.5 -18.0 0.0 0.0 0.253
0.46 0.07 -0.9 13.5 -18.0 0.0 96.9 0.253
0.92 0.06 -0.8 13.5 -18.0 0.0 96.9 0.253
1.37 0.05 -0.7 13.5 -18.0 0.0 96.9 0.253
1.83 0.04 -0.6 13.5 -18.0 0.0 96.9 0.253
2.29 0.04 -0.5 13.5 -18.0 0.0 96.9 0.253
2.75 0.03 -0.4 13.5 -18.0 0.0 96.9 0.253
3.21 0.02 -0.3 13.5 -18.0 0.0 96.9 0.253
3.67 0.01 -0.2 13.5 -18.0 0.0 96.9 0.253
4.12 0.01 -0.1 13.5 -18.0 0.0 96.9 0.253
4.58 0.00 0.0 13.5 18.0 0.0 96.9 0.253
5.04 0.01 0.1 13.5 18.0 0.0 96.9 0.253
5.50 0.02 0.2 13.5 18.0 0.0 96.9 0.253
5.96 0.02 0.3 13.5 18.0 0.0 96.9 0.253
6.42 0.03 0.4 13.5 18.0 0.0 96.9 0.253
6.87 0.04 0.5 13.5 18.0 0.0 96.9 0.253
7.33 0.04 0.6 13.5 18.0 0.0 96.9 0.253
7.79 0.05 0.7 13.5 18.0 0.0 96.9 0.253
8.25 0.06 0.8 13.5 18.0 0.0 96.9 0.253
8.71 0.07 0.9 13.5 18.0 0.0 96.9 0.253
9.17 0.07 1.0 13.5 18.0 0.0 0.0 0.253
2.1.4 Axial
2.1.4.1 Summary Table

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 12


Page 174of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

Loc. Util. Pu ΦPn (C) ΦPn (T) ΦPcrit As Aps Loss Ag


(ft) (k) (k) (k) (k) (in²) (in²) (%) (in²)
0.00 0.05 14.46 307.63 0.00 ∞ 0.00 0.00 0.00 116.00
0.46 0.05 14.36 316.20 12.15 262.76 0.82 0.00 0.00 116.00
0.92 0.05 14.26 324.76 27.00 262.76 0.82 0.00 0.00 116.00
1.37 0.05 14.16 324.76 32.40 262.76 0.82 0.00 0.00 116.00
1.83 0.05 14.06 324.76 32.40 262.76 0.82 0.00 0.00 116.00
2.29 0.05 13.96 324.76 32.40 262.76 0.82 0.00 0.00 116.00
2.75 0.05 13.86 324.76 32.40 262.76 0.82 0.00 0.00 116.00
3.21 0.05 13.76 324.76 32.40 262.76 0.82 0.00 0.00 116.00
3.67 0.05 13.66 324.76 32.40 262.76 0.82 0.00 0.00 116.00
4.12 0.05 13.56 324.76 32.40 262.76 0.82 0.00 0.00 116.00
4.58 0.05 13.46 324.76 32.40 262.76 0.82 0.00 0.00 116.00
5.04 0.05 13.36 324.76 32.40 262.76 0.82 0.00 0.00 116.00
5.50 0.05 13.26 324.76 32.40 262.76 0.82 0.00 0.00 116.00
5.96 0.05 13.16 324.76 32.40 262.76 0.82 0.00 0.00 116.00
6.42 0.05 13.06 324.76 32.40 262.76 0.82 0.00 0.00 116.00
6.87 0.05 12.96 324.76 32.40 262.76 0.82 0.00 0.00 116.00
7.33 0.05 12.86 324.76 32.40 262.76 0.82 0.00 0.00 116.00
7.79 0.05 12.76 324.76 32.40 262.76 0.82 0.00 0.00 116.00
8.25 0.05 12.66 324.76 27.00 262.76 0.82 0.00 0.00 116.00
8.71 0.05 12.56 316.20 12.15 262.76 0.82 0.00 0.00 116.00
9.17 0.04 12.46 307.63 0.00 ∞ 0.00 0.00 0.00 116.00

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 13


Page 175of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 4/24/2023 8:31 PM

2.1.1 In-Place Service Summary


All Combinations
2.1.1.1 Tension
2.1.1.1.1 Summary Table
Exterior Interior
Location Tension Cracking Tension Cracking M P
(ft) (psi) (psi) (psi) (psi) (k-ft) (k)
0.0 0.0 580.9 0.0 580.9 0.00 7.7
0.5 0.3 580.9 0.0 580.9 -0.25 4.5
0.9 36.1 580.9 0.0 580.9 -0.48 4.5
1.4 67.7 580.9 0.0 580.9 -0.68 4.4
1.8 95.2 580.9 0.0 580.9 -0.86 4.4
2.3 118.6 580.9 0.0 580.9 -1.01 4.3
2.7 137.8 580.9 0.0 580.9 -1.13 4.3
3.2 152.8 580.9 0.0 580.9 -1.22 4.2
3.7 163.6 580.9 0.0 580.9 -1.29 4.2
4.1 170.3 580.9 0.0 580.9 -1.33 4.1
4.6 172.8 580.9 0.0 580.9 -1.34 4.1
5.0 171.1 580.9 0.0 580.9 -1.33 4.0
5.5 165.3 580.9 0.0 580.9 -1.29 4.0
6.0 155.3 580.9 0.0 580.9 -1.22 3.9
6.4 141.1 580.9 0.0 580.9 -1.13 3.9
6.9 122.7 580.9 0.0 580.9 -1.00 3.8
7.3 100.2 580.9 0.0 580.9 -0.86 3.8
7.8 73.6 580.9 0.0 580.9 -0.68 3.7
8.2 42.8 580.9 0.0 580.9 -0.48 3.7
8.7 8.0 580.9 0.0 580.9 -0.25 3.6
9.2 0.0 580.9 0.0 580.9 0.00 6.0
2.1.1.2 Total Compression
2.1.1.2.1 Summary Table
Exterior Interior
Location Comp. Limit Comp. Limit M P
(ft) (psi) (psi) (psi) (psi) (k-ft) (k)
0.0 94.4 3600.0 94.4 3600.0 0.00 11.0
0.5 71.6 3600.0 116.6 3600.0 -0.19 10.0
0.9 57.5 3600.0 142.7 3600.0 -0.37 10.0
1.4 10.4 3600.0 171.0 3600.0 -0.69 7.4
1.8 0.0 3600.0 197.6 3600.0 -0.87 7.3
2.3 0.0 3600.0 220.0 3600.0 -1.02 7.2
2.7 0.0 3600.0 238.3 3600.0 -1.14 7.2
3.2 0.0 3600.0 252.3 3600.0 -1.23 7.1
3.7 0.0 3600.0 262.1 3600.0 -1.30 7.0
4.1 0.0 3600.0 267.7 3600.0 -1.34 6.9
4.6 0.0 3600.0 269.1 3600.0 -1.35 6.8
5.0 0.0 3600.0 266.2 3600.0 -1.34 6.7
5.5 0.0 3600.0 259.1 3600.0 -1.30 6.7
6.0 0.0 3600.0 247.8 3600.0 -1.23 6.6
6.4 0.0 3600.0 232.3 3600.0 -1.14 6.5
6.9 0.0 3600.0 212.6 3600.0 -1.01 6.4
7.3 0.0 3600.0 188.7 3600.0 -0.86 6.3
7.8 0.5 3600.0 160.7 3600.0 -0.69 6.2
8.2 46.1 3600.0 131.1 3600.0 -0.37 8.6
8.7 58.8 3600.0 103.6 3600.0 -0.19 8.6
9.2 80.1 3600.0 80.1 3600.0 0.00 9.3
2.1.1.3 Deflection
2.1.1.3.1 Summary Graph Legend
Deflection
0.50

Allowable
Deflection, in

Max Deflection: 0.056 in


0.00

Min Deflection: -0.043 in


-0.50

0 11 22 33 44 55 66 77 88 99 110
Location, in:

Type A-run -1.ewf Copyright © 2017-2021 Eriksson Software pg. 15


Page 176of 248
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : PRECAST WALL DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

DESIGN FOR 8" THICK VERTICAL PRECAST SANDWICH WALLPANEL DESIGN TYPE
C Run-3
Design Notes:

* Wallpanel is located near grid "A" and b/w Grids "1 & 2" @ East Elevation.
* Critical Wallpanel is designed for Roof Truss load and C&C Wind Loads.
* Assume the Wall panel is pinned at Roof deck Level.
* Design will be valid for 8" Thick Sandwich WP.
* 96" Critical width of panel is considered as design section Conservatively.
* 4" Interior Wythe is designed as Load bearing for Vertical Load ( DL + Live) and Wind load on conservative side
Ignoring composite behaviour of the section (also a separate calculation is attached For composite action for
reference).
Design section is considered as 8" x 96"

DESIGN LOADS:

Roof truss load on Wallpanel:

P1: Load from Right side Roof:

Dead Load (Refer truss design) (U11 - Truss) = 0.735 Kip


(U15 - Truss) = 0.87 Kip

Live Load (Refer truss design) (U11 - Truss) = 0.726 Kip


(U15 - Truss) = 0.812 Kip

Total dead load on Wall = 1.605 Kip


Total live load on Wall = 1.538 Kip

Wind Loads on Wallpanel: (Walls)

Wind acting on exposed width = 8.00 ft (at Level-2)

(P2) Components & Cladding Wind (Pressure) = 59.30 psf (Refer Wind Load Calculation Sheets)

(For an exposed area of 73.28 Sq. Ft) = 8.00' x 9.16' = 73.28 sq.ft
(Postive Zone 4 & 5)
Wind Pressure at the areas exposed in plf = 59.30 psf x 8.00' = 474.4 plf

(P3) Components & Cladding Wind (Suction) = 73.60 psf (Refer Wind Load Calculation Sheets)

(For an exposed area of 73.28 Sq. Ft) = 8.00' x 9.16' = 73.28 sq.ft
(Negative Zone 5)
Wind Pressure at the areas exposed in plf = 73.60 psf x 8.00' = 588.8 plf

Page 177of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : PRECAST WALL DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Loading diagram

Load Units: kips & in-kips Wind Load Units: plf

P1 P2 Pressure 474.4 plf


WALLS
DL 1.6 P3 Suction 588.8 plf
Mx -
Mz -
LL 1.5
Mx -
Mz -
SL -
Mx -
Mz -
Vu 4.4
Vudl 1.9

Load Combinations:

According to ASCE 7-16 - Section 2.3.1

1) 1.4 DL
2) 1.2 DL + 1.6 LL GOVERNS
3) 1.2 DL + 1.0 WL(Pressure) + 1.0LL
4) 1.2 DL + 1.0 WL(Suction) + 1.0LL
5) 0.9 DL + 1.0 WL (Pressure)
6) 0.9 DL + 1.0 WL (Suction)

Page 178of 248


Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Project Information
Project: BURNT STORE LAKES Location: Project Location Date: 3/17/2023
Client: ONX Designer: Job No.:
Description: Design Type C-Run3 Spec: ACI 318-14
Material Properties
Concrete
Top Wythe
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0

In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight


Bottom Wythe
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0
In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight

Rebar Mesh Strand


fy (ksi) 60 - fpu (ksi) -
Es (ksi) 29000 - Ep (ksi) -
Exterior Soil Interior Soil
Design contains no exterior soil loads Design contains no interior soil loads
Load Combinations
Strength Combinations Service Combinations
# D L R W E T H Include # D L R W E T H Include
1 1.4 0 0 0 0 0 0 1 1 0 0 0 0 0 0
2 1.2 1.6 0 0 0 0 0 2 1 1 0 0 0 0 0
3 1.2 1 0 0 0 0 0 3 1 0 0 0 0 0 0
4 1.2 0 0 0.5 0 0 0 4 1 0.75 0 0 0 0 0
5 1.2 1 0 1 0 0 0 5 1 0 0 0.6 0 0 0
6 1.2 1 0 0 0 0 0 6 1 0 0 0 0 0 0
7 0.9 0 0 1 0 0 0 7 1 0.75 0 0.45 0 0 0
8 0.9 0 0 0 0 0 0 8 1 0.75 0 0 0 0 0
9 0.6 0 0 0.6 0 0 0
10 0.6 0 0 0 0 0 0
Settings
Deflection Limits Stress Options Resistance Factors
Add initial bow to reported deflections Failure if cracked Developed Transfering
Tension 0.9 0.75
Additional Bow: 0" Ignore Lateral Strand Eccentricity
Compression 0.65 -
Total Deflection Limit: L / 150
Use Principal Axis Shear 0.75 -
Elastic Analysis
2nd Order Effects: P-Delta
In Place Stress Limits Development Multipliers
Analysis βd : Non-Sway Modulus of Rupture (psi): 7.5 √fc Strand (Normal): 1

R-Value Calculation Compression: 0.6 fc Strand (Debonded): 2


Handling Stress Limits Strand (Cut): 1
Concrete Resistance (k): 13.33
Tension: 7.5 √fc
Insulation Resistance (k): 0.238 Mild: 1
Compression: 0.6 fc Shear Options
Interior Resistance (R): 0.68
Flexure Options Treat as column
Exterior Resistance (R): 0.17 Method: Whitney Stress Block
Cracking Check: None Axial Options
Bottom Length Ignored: 0"
Ignore tensile strength failures
Top Length Ignored: 0"
Ignore buckling failures

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 1


Page 179of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Concrete Extents
Panel Geometry
Top Elevation : 9'-2" Insulation Thickness : 2"
Bottom Elevation : 0" Top Wythe
Height : 9'-2" Width : 8'-0" Thickness : 4"
Bottom Wythe
Section Type : Sandwich Panel
Width : 8'-0" Thickness : 2"
Top in Form : Interior
Top End Block : 0"
Bottom End Block : 0"

Left Miter Right Miter


Left miter not included in design Right miter not included in design
Openings, Reveals, and Solid Zones
Wall design contains no openings, reveals, or solid zones.

8" 8'-0"

Area, in²: 576.00


Width, in: 96.00
Height, in: 8.00
Cx, in: 48.00
Cy, in: 4.33
9'-2"

9'-2"
Izz, in⁴: 3776.00
Iyy, in⁴: 442368.00
Izy, in⁴: 0.00
Sb, in³: 871.38
St, in³: 1029.82

0.200L
1'-10"

Side Elevation Front Elevation Section Properties


8'-0"
2" 2" 4"

8"

Cross Section

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 2


Page 180of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Structural Model
Restraints Releases
Add foundation connection Restrain Moment:
Design contains no releases.

Add floor tie


ID Elevation Type Gravity Rest. Thermal Rest. Stiffness (k/in)
1 0" Restrained -
2 9'-2" Restrained -

9.17 ft

Concentrated Loads Load Options


Load Components (k / kip-ft) Pattern Live Loads for Flexure
ID Elevation Ecc Dead Live Roof Pres. Suct. Seis.
↓ 1.605 1.538 0 0 0 0
P1 12'-2.0" 0.0"
→ 0 0 0 0 0 0 Selfweight eccentricity: 0"
Eccentricity measured from: Panel CG
Wind Loads
Start End
ID Type Start Mag. End Mag.
from Bot from Top
W1 Pressure 474.4 plf 474.4 plf
0" 0"
W2 Suction 588.8 plf 588.8 plf

Seismic Loads
Zone Location(s): Full height
Apply multipliers to Deadload + Self weight
Start of Zone (x/L) End of Zone (x/L) Seismic Load (Cs, % of DL)
0.00 1.00 0.0

Temperature Loads Interior Soil Loads Exterior Soil Loads Additional Self Weight
Exterior Temperature (F°): 105 Elevation: 0" Elevation: 0" Start from Bottom: 0"
Interior Temperature (F°): 75 Surcharge (psf): 0 Surcharge (psf): 0 End from Top: 0"
Thermal Elasticity Multiplier: 1 Magnitude (plf): 0
Exterior

W1

W2

Interior
Structural Sections
No structural sections defined, using entire cross section.

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 3


Page 181of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Reinforcement
Strands
Design contains no prestressing
Rebar
Depth to Loc. from Start from End from Start End
Size Area Diameter Quantity Spacing
CG Left Bottom Top Condition Condition
#3 0.11 0.375" 3 3'-0" 7" 11" 1" 1" Straight Straight
#3 0.11 0.375" 3 3'-0" 7" 1'-2" 1" 1" Straight Straight
#3 0.11 0.375" 9 1'-0" 2" 2" 1" 1" Straight Straight
Mesh
Design contains no mesh
Interrupts
Design contains no interrupts

8'-0"

8'-0"

1" 5" 2"


2" 9" 3" 1'-0" 1'-0" 9" 3" 1'-0" 1'-0" 9" 3" 10" (14) #3

0.500L
9'-2"

4'-7"
Strand Mild
Aps, in²: 0.00 As, in²: 1.54
cgx, in: 0.00 cgx, in: 45.93
cgy, in: 0.00 cgy, in: 3.86
ex, in: 0.00
ey, in: 0.00

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 4


Page 182of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

PROJECT: LOCATION: JOB NO.:


BURNT STORE LAKES Project Location

CLIENT: ENGINEER: CHECKER: DATE:


ONX Checker 03/17/23

DESIGN THICKNESS 8"


DESIGN WIDTH 8'-0"
DESIGN HEIGHT 9'-2"

8'-0"
2"

8"
1" 5"

2" 9" 3" 1'-0" 1'-0" 9" 3" 1'-0" 1'-0" 9" 3" 10" (14) #3 x 9'-0"

Section View (0.50L - 4'-7")

CONCRETE MIX: CONCRETE AT RELEASE (f'ci): CONCRETE AT 28 DAYS (f'c): CONCRETE DENSITY:
Standard Mix 3500 psi 6000 psi 150 pcf
PRIMARY TOP REINFORCEMENT: (9) #3 x 9'-0"

PRIMARY BOT REINFORCEMENT: (6) #3 x 9'-0"

1'-11" 5'-4" 1'-11"


1'-7⅞"

1'-11" 5'-4" 1'-11"


4'-8¼"
1'-7⅞"

STRIPPING & BLOCKING DETAIL


STRIP WITH: REVISION: DESIGN NUMBER:

Strip
ERECT WITH: 1
Erection

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 5


Page 183of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Loading Summary
Concentrated Load Summary
Design contains no concentrated loads

Distributed Load Summary


ID Type Dir Description
Wp Horz. -0.474 k / ft at 0.00 ft to -0.474 k / ft at 9.17 ft
Ws Horz. 0.589 k / ft at 0.00 ft to 0.589 k / ft at 9.17 ft
SW Vert. -0.600 k / ft at 0.00 ft to -0.600 k / ft at 9.17 ft Self Weight

Point Moment Summary


Design contains no point moments

Load Patterns Summary


ID Wind Soil Loads Seismic Loads Live Loads
All Left Right L-R R-L
Pressure Suction External Internal Positive Negative
Alternate Alternate
1 ✓ - - - - - - - - - -
2 - ✓ - - - - - - - - -

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 6


Page 184of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Project Information Panel Properties


Project: BURNT STORE LAKES Location: Project Location Date: 03/17/23 f'ci: 3.5 ksi f'c: 6.0 ksi Δlim: 0.73 in
Client: ONX Designer: Job #: Δ T: 30.0 F° Initial Bow: 0.0 in Δ Max: 0.05/-0.04 in
Description: Design Type C-Run3
Specification: ACI 318-14, PCI Design Handbook 8ᵗʰ Edition

Loading [ ID - Load Case - Direction - Magnitude (k / plf) ] Ultimate Reactions (Elevation, Magnitude (k), Direction)
Dy 1.61 Ly 1.54 W1 Wp 474.4 W2 Ws 588.8 0" 2.71 → 0" 7.70 ↓ 0" 2.18 ←
9'-2" 2.70 → 9'-2" 2.18 ←

Stripping Interaction Diagram (Controlling Section @ 0.50L / 55 in)


Face Inserts: Qty: 4 Shear: 1.1 k Tension: 1.9 k

600 900 1200 1500 1800 2100


Shear Utilization: 0.07 (2.2 k / 34.1 k) Max Comp.: 26 psi / 2100 psi
Flexure Utilization: 0.07 (-1.5 k-ft / -21.7 k-ft) Max Tension: 24 psi / 444 psi

Transportation
Shear Utilization: 0.05 (2.4 k / 44.6 k) Max Comp.: 28 psi / 3600 psi
Flexure Utilization: 0.07 (-1.7 k-ft / -22.0 k-ft) Max Tension: 26 psi / 581 psi

Axial Capacity (k)


Stage: Erection
Face Inserts: Qty: 4 Shear: 1.1 k Tension: 1.9 k
Edge Inserts: Qty: 2 Shear: 0.0 k Tension: 3850.0 k
Shear Utilization: 0.05 (2.2 k / 44.6 k) Max Comp.: 26 psi / 3600 psi
Flexure Utilization: 0.07 (-1.5 k-ft / -22.0 k-ft) Max Tension: 24 psi / 581 psi
300

Stage: In-Place
0

Shear LC: LC 5 - 1.2D + 1.0L + 1.0W


P1

Flexure LC: LC 7 - 0.9D + 1.0W


-300

Shear Utilization: 0.06 (-2.7 k / -44.6 k) Max Comp.: 182 psi / 3600 psi
Flexure Utilization: 0.77 (-6.2 k-ft / -8.1 k-ft) Max Tension: 170 psi / 581 psi -90 -60 -30 0 30 60 90
Axial Utilization: 0.01 (7.3 k/ 1032.5 k) Moment Capacity (k-ft)

8'-0"
9'-2"
W1

W2

0.8 0.4 0.0 200 100 0 200 100 0


Flexure Utilization Comp. Stress Tension Stress
Structural Model Front Elevation - Not to Scale (Mu/ϕMn) (psi) (psi)

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 7


Page 185of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

1 Design Parameters
1.1 Composite Section Properties
Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ
(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
0.92 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
1.83 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
2.75 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
3.67 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
4.58 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
5.50 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
6.42 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
7.33 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
8.25 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
9.17 96.00 8.00 576.00 48.00 3.67 3776 442368 446144 0.00 0.00
1.2 Non-composite Section Properties
Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ
(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
0.92 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
1.83 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
2.75 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
3.67 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
4.58 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
5.50 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
6.42 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
7.33 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
8.25 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00
9.17 96.00 4.00 384.00 48.00 2.00 512 294912 295424 0.00 0.00

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 8


Page 186of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Detailed Flexure Capacity


Load Combination : All Combinations

Location : 4.58' (0.500 L) - LC 7 - Controlling

0% Composite Capacity

Y
X

Cross Section
Capacity Parameters Flexure Parameters Concrete Properties
Utilization : 0.766 Pu : 2.475 k Section f'c Ec λ wc
ϕMnx : -8.096 k-ft Mx : -6.201 k-ft (psi) (ksi) (pcf)
ϕPn, Compression : 1043.490 k INT 6000.0 4696.0 1.00 150.0
εcu : 0.003 in/in
EXT 6000.0 4696.0 1.00 150.0
ϕPn, Tension : -47.520 k c : 0.151 in
Rebar Properties
Pcrit : 686.402 k θ : -180.000 deg
ϕ : 0.900 Height : 8.000 in
fy : 60.0 ksi Es : 29000.0 ksi
ϕTension : 0.900 CGx : 48.000 in Mesh Properties
ϕCompression : 0.650 CGy : 3.667 in fy : ksi Es : ksi
Strand Properties
Section does not contain any strand.
Concrete Force
Method: Whitney Stress Block
β : 0.750
a : 0.113 in
Section Comp. Area Cx Cy Force
(in²) (in) (in) (k)
INT 10.892 48.000 0.057 -55.550
EXT 0.000 0.000
10.892 48.000 0.057 -55.550
Mild Tension Force

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 9


Page 187of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Area Stress
# X Y Base Developed Effective Strain Base Concrete Total Force Mxi Myi
(in) (in) (in²) (%) (in²) (10⁻³) (ksi) (ksi) (ksi) (k) (k-ft) (k-ft)
1 85.000 7.000 0.110 100.00 0.110 135.815 60.000 0.000 60.000 6.600 -1.833 20.350
2 49.000 7.000 0.110 100.00 0.110 135.815 60.000 0.000 60.000 6.600 -1.833 0.550
3 13.000 7.000 0.110 100.00 0.110 135.815 60.000 0.000 60.000 6.600 -1.833 -19.250
4 82.000 7.000 0.110 100.00 0.110 135.815 60.000 0.000 60.000 6.600 -1.833 18.700
5 46.000 7.000 0.110 100.00 0.110 135.815 60.000 0.000 60.000 6.600 -1.833 -1.100
6 10.000 7.000 0.110 100.00 0.110 135.815 60.000 0.000 60.000 6.600 -1.833 -20.900
7 94.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 25.300
8 82.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 18.700
9 70.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 12.100
10 58.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 5.500
11 46.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 -1.100
12 34.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 -7.700
13 22.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 -14.300
14 10.000 2.000 0.110 100.00 0.110 36.662 60.000 0.000 60.000 6.600 0.917 -20.900
50.071 4.143 1.540 100.00 1.540 60.000 0.000 60.000 92.400 -3.667 15.950
Mild Compression Force
Sections contains no mild reinforcement in compression
Prestressed Reinforcement Force
Design contains to prestressed reinforcement
Resistance Factor Axial Capacity Convergence Check
εmax : 135.815 10⁻³ in/in ϕ : 0.900 Ag : 576.00 in² Pu /ϕ : -2.750 k

Flexure Capacity Astr : 1.540 in² Fconc : -55.550 k


Apt : 0.000 in² Fmild : 92.400 k
x Axis
fse : 0.00 ksi Fstrand : 0.000 k
Mconc : -16.711 k-ft ϕPn Comp : 1043.490 k Total : 39.600 k
Mmild : -3.667 k-ft ϕPn Tens : 47.520 k
Mstrand : 0.000 k-ft
Plain Concrete Strength
Mnx : -20.378 k-ft ϕMnx : 4.857 k-ft

ϕMnx : -18.340 k-ft

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 10


Page 188of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

ϕMn vs ϕPn

2100
Mn vs Pn
Demand ⬤

1800
1500 1200
Axial Capacity (k)
600 900
300
0
-300

-90 -60 -30 0 30 60 90


Moment Capacity (k-ft)
PM Diagram
(Loading angle fixed at 180.00 deg)

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 11


Page 189of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

2.1 In-Place Strength Summary


All Combinations
2.1.1 Reaction Forces
Out-of-plane
Location Towards Interior Towards Exterior
0" 2.71 k 2.18 k
9'-2" 2.70 k 2.18 k
2.1.2 Flexure
2.1.2.1 Summary Table
Loc. Util. Mu Φ ΦMn Mcr Pu ΦPn c θ As A's Aps Loss d
(ft) (k-ft) (k-ft) (k-ft) (k) (k) (in) (deg) (in²) (in²) (in²) (%) (in)
0.00 0.00 0.0 0.65 1.3 12.2 7.7 1018.4 0.03 0.0 0.00 0.00 0.00 0.00 0.00
0.46 0.25 -1.2 0.90 -3.7 -4.0 4.7 1032.5 0.07 180.0 0.58 0.00 0.00 0.00 4.14
0.92 0.31 -2.2 0.90 -7.2 -4.0 4.5 1043.5 0.13 180.0 1.28 0.00 0.00 0.00 4.14
1.37 0.38 -3.2 0.90 -8.4 -4.0 4.2 1043.5 0.16 180.0 1.54 0.00 0.00 0.00 4.14
1.83 0.48 -4.0 0.90 -8.3 -4.0 4.0 1043.5 0.16 180.0 1.54 0.00 0.00 0.00 4.14
2.29 0.56 -4.7 0.90 -8.3 -4.0 3.7 1043.5 0.16 180.0 1.54 0.00 0.00 0.00 4.14
2.75 0.63 -5.2 0.90 -8.3 -4.1 3.5 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
3.21 0.69 -5.6 0.90 -8.2 -4.1 3.2 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
3.67 0.73 -6.0 0.90 -8.2 -4.1 3.0 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
4.12 0.75 -6.1 0.90 -8.1 -4.1 2.7 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
4.58 0.77 -6.2 0.90 -8.1 -4.1 2.5 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
5.04 0.76 -6.1 0.90 -8.1 -4.1 2.2 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
5.50 0.74 -6.0 0.90 -8.0 -4.1 2.0 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
5.96 0.71 -5.6 0.90 -8.0 -4.1 1.7 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
6.42 0.66 -5.2 0.90 -7.9 -4.1 1.5 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
6.87 0.59 -4.6 0.90 -7.9 -4.1 1.2 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
7.33 0.50 -4.0 0.90 -7.9 -4.1 1.0 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
7.79 0.40 -3.2 0.90 -7.8 -4.1 0.7 1043.5 0.15 180.0 1.54 0.00 0.00 0.00 4.14
8.25 0.34 -2.2 0.90 -6.5 -4.1 0.5 1043.5 0.12 180.0 1.28 0.00 0.00 0.00 4.14
8.71 0.24 -1.2 0.90 -3.0 -4.1 0.2 1032.5 0.05 180.0 0.58 0.00 0.00 0.00 4.14
9.17 0.00 0.0 0.00 0.0 12.4 0.0 1018.4 0.00 0.0 0.00 0.00 0.00 0.00 0.00
2.1.3 Shear
2.1.3.1 Summary Table
Loc. Util Vu ϕVn Vc Vs Req b wd Av Min
(ft) (k) (k) (k) (k) (in²) (in²/ft)
0.00 0.06 -2.7 44.6 -59.5 0.0 0.0 0.837
0.46 0.05 -2.4 44.9 -59.9 0.0 384.0 0.837
0.92 0.05 -2.2 44.9 -59.8 0.0 384.0 0.837
1.37 0.04 -1.9 44.9 -59.8 0.0 384.0 0.837
1.83 0.04 -1.6 44.8 -59.8 0.0 384.0 0.837
2.29 0.03 -1.4 44.8 -59.8 0.0 384.0 0.837
2.75 0.02 -1.1 44.8 -59.8 0.0 384.0 0.837
3.21 0.02 -0.8 44.8 -59.7 0.0 384.0 0.837
3.67 0.01 -0.5 44.8 -59.7 0.0 384.0 0.837
4.12 0.01 -0.3 44.8 -59.7 0.0 384.0 0.837
4.58 0.00 0.0 44.8 59.7 0.0 384.0 0.837
5.04 0.01 0.3 44.8 59.7 0.0 384.0 0.837
5.50 0.01 0.5 44.8 59.7 0.0 384.0 0.837
5.96 0.02 0.8 44.8 59.7 0.0 384.0 0.837
6.42 0.02 1.1 44.7 59.6 0.0 384.0 0.837
6.87 0.03 1.4 44.7 59.6 0.0 384.0 0.837
7.33 0.04 1.6 44.7 59.6 0.0 384.0 0.837
7.79 0.04 1.9 44.7 59.6 0.0 384.0 0.837
8.25 0.05 2.2 44.7 59.5 0.0 384.0 0.837
8.71 0.05 2.4 44.6 59.5 0.0 384.0 0.837
9.17 0.06 2.7 44.6 59.5 0.0 0.0 0.837
2.1.4 Axial
2.1.4.1 Summary Table

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 13


Page 190of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

Loc. Util. Pu ΦPn (C) ΦPn (T) ΦPcrit As Aps Loss Ag


(ft) (k) (k) (k) (k) (in²) (in²) (%) (in²)
0.00 0.01 7.70 1018.37 0.00 ∞ 0.00 0.00 0.00 384.00
0.46 0.01 7.32 1032.50 17.82 686.40 1.54 0.00 0.00 384.00
0.92 0.01 6.93 1043.49 39.60 686.40 1.54 0.00 0.00 384.00
1.37 0.01 6.55 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
1.83 0.01 6.16 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
2.29 0.01 5.78 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
2.75 0.01 5.39 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
3.21 0.01 5.01 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
3.67 0.01 4.62 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
4.12 0.01 4.24 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
4.58 0.01 3.85 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
5.04 0.01 3.47 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
5.50 0.00 3.08 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
5.96 0.00 2.70 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
6.42 0.00 2.31 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
6.87 0.00 1.93 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
7.33 0.00 1.54 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
7.79 0.00 1.16 1043.49 47.52 686.40 1.54 0.00 0.00 384.00
8.25 0.00 0.77 1043.49 39.60 686.40 1.54 0.00 0.00 384.00
8.71 0.00 0.39 1032.50 17.82 686.40 1.54 0.00 0.00 384.00
9.17 0.00 0.00 1018.37 0.00 ∞ 0.00 0.00 0.00 384.00

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 14


Page 191of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/17/2023 7:04 PM

2.1.1 In-Place Service Summary


All Combinations
2.1.1.1 Tension
2.1.1.1.1 Summary Table
Exterior Interior
Location Tension Cracking Tension Cracking M P
(ft) (psi) (psi) (psi) (psi) (k-ft) (k)
0.0 0.0 580.9 0.0 580.9 0.00 5.5
0.5 25.0 580.9 0.0 580.9 -0.71 3.1
0.9 55.0 580.9 0.0 580.9 -1.34 3.0
1.4 81.6 580.9 0.0 580.9 -1.90 2.8
1.8 104.7 580.9 0.0 580.9 -2.38 2.6
2.3 124.3 580.9 0.0 580.9 -2.79 2.5
2.7 140.4 580.9 0.0 580.9 -3.12 2.3
3.2 153.0 580.9 0.0 580.9 -3.38 2.1
3.7 162.2 580.9 0.0 580.9 -3.57 2.0
4.1 167.8 580.9 0.0 580.9 -3.68 1.8
4.6 170.0 580.9 0.0 580.9 -3.72 1.7
5.0 168.6 580.9 0.0 580.9 -3.68 1.5
5.5 163.8 580.9 0.0 580.9 -3.57 1.3
6.0 155.5 580.9 0.0 580.9 -3.38 1.2
6.4 143.7 580.9 0.0 580.9 -3.12 1.0
6.9 128.5 580.9 0.0 580.9 -2.79 0.8
7.3 109.7 580.9 0.0 580.9 -2.38 0.7
7.8 87.5 580.9 0.0 580.9 -1.89 0.5
8.2 61.8 580.9 0.0 580.9 -1.34 0.3
8.7 32.6 580.9 0.0 580.9 -0.71 0.2
9.2 0.0 580.9 0.0 580.9 0.00 0.0
2.1.1.2 Total Compression
2.1.1.2.1 Summary Table
Exterior Interior
Location Comp. Limit Comp. Limit M P
(ft) (psi) (psi) (psi) (psi) (k-ft) (k)
0.0 14.3 3600.0 14.3 3600.0 0.00 5.5
0.5 0.0 3600.0 46.8 3600.0 -0.71 5.2
0.9 0.0 3600.0 75.8 3600.0 -1.34 5.0
1.4 0.0 3600.0 101.2 3600.0 -1.90 4.7
1.8 0.0 3600.0 123.2 3600.0 -2.38 4.4
2.3 0.0 3600.0 141.7 3600.0 -2.79 4.1
2.7 0.0 3600.0 156.7 3600.0 -3.13 3.9
3.2 0.0 3600.0 168.2 3600.0 -3.39 3.6
3.7 0.0 3600.0 176.1 3600.0 -3.57 3.3
4.1 0.0 3600.0 180.6 3600.0 -3.69 3.0
4.6 0.0 3600.0 181.6 3600.0 -3.72 2.8
5.0 0.0 3600.0 179.1 3600.0 -3.68 2.5
5.5 0.0 3600.0 173.2 3600.0 -3.57 2.2
6.0 0.0 3600.0 163.7 3600.0 -3.38 1.9
6.4 0.0 3600.0 150.7 3600.0 -3.12 1.7
6.9 0.0 3600.0 134.3 3600.0 -2.79 1.4
7.3 0.0 3600.0 114.4 3600.0 -2.38 1.1
7.8 0.0 3600.0 91.0 3600.0 -1.90 0.8
8.2 0.0 3600.0 64.1 3600.0 -1.34 0.6
8.7 0.0 3600.0 33.8 3600.0 -0.71 0.3
9.2 0.0 3600.0 0.0 3600.0 0.00 0.0
2.1.1.3 Deflection
2.1.1.3.1 Summary Graph Legend
Deflection
0.50

Allowable
Deflection, in

Max Deflection: 0.047 in


0.00

Min Deflection: -0.038 in


-0.50

0 11 22 33 44 55 66 77 88 99 110
Location, in:

Type C-Run -3.ewf Copyright © 2017-2021 Eriksson Software pg. 16


Page 192of 248
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : PRECAST WALL DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

DESIGN FOR 8" THICK VERTICAL PRECAST SANDWICH WALLPANEL DESIGN TYPE
D Run4
Design Notes:

* Wallpanel is located near grid "3" and b/w Grids "E & F" @ North Elevation.
* Critical Wallpanel is designed for Roof Truss load and C&C Wind Loads.
* Assume the Wall panel is pinned at Roof deck Level.
* Design will be valid for 8" Thick Sandwich WP.
* 44" Critical width of panel is considered as design section Conservatively.
* 4" Interior Wythe is designed as Load bearing for Vertical Load ( DL + Live) and Wind load on conservative side
Ignoring composite behaviour of the section (also a separate calculation is attached For composite action for
reference).
Design section is considered as 8" x 21.75"

DESIGN LOADS:

Roof truss load on Wallpanel:

P1: Load from Right side Lintel Beam:

SDL (Refer Lintel beam design concise LB-05) = 2.33 Kip

Live Load (Refer Lintel beam design concise LB-05) = 0.93 Kip

Total dead load on beam = 2.330 Kip


Total live load on beam = 0.93 Kip

P2: Load from Right side Lintel Beam:

SDL (Refer Lintel beam design concise LB-05A) = 1.47 Kip

Total dead load on beam = 1.470 Kip

P3: Load from Right side Roof:

Dead Load (Refer truss design) (U9 - Truss) = 0.728 Kip

Live Load (Refer truss design) (U9 - Truss) = 0.634 Kip

Total dead load on Wall = 0.728 Kip


Total live load on Wall = 0.634 Kip

Page 193of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : PRECAST WALL DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Wind Loads on Wallpanel: (Walls)

Wind acting on exposed width = 1.81 ft (at Level-2)

(P4) Components & Cladding Wind (Pressure) = 64.00 psf (Refer Wind Load Calculation Sheets)

(For an exposed area of 24.60 Sq. Ft) = 1.81' x 11.50' = 20.82 sq.ft
(Postive Zone 4 & 5)
Wind Pressure at the areas exposed in plf = 64.00 psf x 1.81' = 115.8 plf

(P5) Components & Cladding Wind (Suction) = 84.00 psf (Refer Wind Load Calculation Sheets)

(For an
(For
exposed
an exposed
area area
of 24.60
of 24.60
Sq. Ft)
Sq. Ft) = 1.81' x 11.50' = 20.82 sq.ft
(Negative Zone 5)
Wind Pressure at the areas exposed in plf = 84.00 psf x 1.81' = 152.0 plf

Loading diagram

Page 194of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : PRECAST WALL DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Load Units: kips & in-kips Wind Load Units: plf

P1 P2 P2 P3 Pressure 115.8 plf


WALLS
DL 2.3 1.5 0.7 P4 Suction 152.0 plf
Mx - - -
Mz - - -
LL 0.9 0.6
Mx - - -
Mz - - -
SL - - -
Mx - - -
Mz - - -
Vu 4.3 1.8 1.9
Vudl 2.8 1.8 0.9

Load Combinations:

According to ASCE 7-16 - Section 2.3.1

1) 1.4 DL
2) 1.2 DL + 1.6 LL GOVERNS
3) 1.2 DL + 1.0 WL(Pressure) + 1.0LL
4) 1.2 DL + 1.0 WL(Suction) + 1.0LL
5) 0.9 DL + 1.0 WL (Pressure)
6) 0.9 DL + 1.0 WL (Suction)

Page 195of 248


Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Project Information
Project: BURNT STORE LAKES Location: Project Location Date: 3/17/2023
Client: ONX Designer: SJK Job No.: 2110
Description: Design Type D-Run4 Spec: ACI 318-14
Material Properties
Concrete
Top Wythe
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0

In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight


Bottom Wythe
Release fci (ksi): 3.5 Eci (ksi): 3587 Unit Weight (pcf): 150.0
In-Place fc (ksi): 6.0 Ec (ksi): 4696 Concrete Type: Normalweight

Rebar Mesh Strand


fy (ksi) 60 - fpu (ksi) -
Es (ksi) 29000 - Ep (ksi) -
Exterior Soil Interior Soil
Design contains no exterior soil loads Design contains no interior soil loads
Load Combinations
Strength Combinations Service Combinations
# D L R W E T H Include # D L R W E T H Include
1 1.4 0 0 0 0 0 0 1 1 0 0 0 0 0 0
2 1.2 1.6 0 0 0 0 0 2 1 1 0 0 0 0 0
3 1.2 1 0 0 0 0 0 3 1 0 0 0 0 0 0
4 1.2 0 0 0.5 0 0 0 4 1 0.75 0 0 0 0 0
5 1.2 1 0 1 0 0 0 5 1 0 0 0.6 0 0 0
6 1.2 1 0 0 0 0 0 6 1 0 0 0 0 0 0
7 0.9 0 0 1 0 0 0 7 1 0.75 0 0.45 0 0 0
8 0.9 0 0 0 0 0 0 8 1 0.75 0 0 0 0 0
9 0.6 0 0 0.6 0 0 0
10 0.6 0 0 0 0 0 0
Settings
Deflection Limits Stress Options Resistance Factors
Add initial bow to reported deflections Failure if cracked Developed Transfering
Tension 0.9 0.75
Additional Bow: 0" Ignore Lateral Strand Eccentricity
Compression 0.65 -
Total Deflection Limit: L / 150
Use Principal Axis Shear 0.75 -
Elastic Analysis
2nd Order Effects: P-Delta
In Place Stress Limits Development Multipliers
Analysis βd : Non-Sway Modulus of Rupture (psi): 7.5 √fc Strand (Normal): 1

R-Value Calculation Compression: 0.6 fc Strand (Debonded): 2


Handling Stress Limits Strand (Cut): 1
Concrete Resistance (k): 13.33
Tension: 7.5 √fc
Insulation Resistance (k): 0.238 Mild: 1
Compression: 0.6 fc Shear Options
Interior Resistance (R): 0.68
Flexure Options Treat as column
Exterior Resistance (R): 0.17 Method: Whitney Stress Block
Cracking Check: None Axial Options
Bottom Length Ignored: 0"
Ignore tensile strength failures
Top Length Ignored: 0"
Ignore buckling failures

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 1


Page 196of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Concrete Extents
Panel Geometry
Top Elevation : 11'-6" Insulation Thickness : 2"
Bottom Elevation : 0" Top Wythe
Height : 11'-6" Width : 1'-9.75" Thickness : 4"
Bottom Wythe
Section Type : Sandwich Panel
Width : 1'-9.75" Thickness : 2"
Top in Form : Interior
Top End Block : 0"
Bottom End Block : 0"

Left Miter Right Miter


Left miter not included in design Top In Form
Width : 0" Height : 0"
Openings, Reveals, and Solid Zones
Wall design contains no openings, reveals, or solid zones.

8" 1'-9¾"

Area, in²: 130.50


Width, in: 21.75
Height, in: 8.00
Cx, in: 10.88
11'-6"

11'-6"

Cy, in: 4.33


Izz, in⁴: 855.50
Iyy, in⁴: 5144.55
Izy, in⁴: 0.00
Sb, in³: 197.42
St, in³: 233.32

0.200L
2'-3⅝"

Side Elevation Front Elevation Section Properties


1'-9¾"
4"

8"
2" 2"

Cross Section

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 2


Page 197of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Structural Model
Restraints Releases
Add foundation connection Restrain Moment:
Design contains no releases.

Add floor tie


ID Elevation Type Gravity Rest. Thermal Rest. Stiffness (k/in)
1 0" Restrained -
2 11'-6" Restrained -

11.50 ft

Concentrated Loads Load Options


Load Components (k / kip-ft) Pattern Live Loads for Flexure
ID Elevation Ecc Dead Live Roof Pres. Suct. Seis.
↓ 2.33 0.93 0 0 0 0
P1 11'-6.0" 0.0"
→ 0 0 0 0 0 0 Selfweight eccentricity: 0"
↓ 1.47 0 0 0 0 0
P2 11'-6.0" 0.0" Eccentricity measured from: Panel CG
→ 0 0 0 0 0 0
↓ 0.728 0.634 0 0 0 0
P3 11'-6.0" 0.0"
→ 0 0 0 0 0 0

Wind Loads
Start End
ID Type Start Mag. End Mag.
from Bot from Top
W1 Pressure 115 plf 115 plf
0" 0"
W2 Suction 152 plf 152 plf

Seismic Loads
Zone Location(s): Full height
Apply multipliers to Deadload + Self weight
Start of Zone (x/L) End of Zone (x/L) Seismic Load (Cs, % of DL)
0.00 1.00 0.0

Temperature Loads Interior Soil Loads Exterior Soil Loads Additional Self Weight
Exterior Temperature (F°): 105 Elevation: 0" Elevation: 0" Start from Bottom: 0"
Interior Temperature (F°): 75 Surcharge (psf): 0 Surcharge (psf): 0 End from Top: 0"
Thermal Elasticity Multiplier: 1 Magnitude (plf): 0
Exterior

W1

P1,P2,P3

W2

Interior
Structural Sections
No structural sections defined, using entire cross section.

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 3


Page 198of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Reinforcement
Strands
Design contains no prestressing
Rebar
Depth to Loc. from Start from End from Start End
Size Area Diameter Quantity Spacing
CG Left Bottom Top Condition Condition
#3 0.11 0.375" 1 3'-0" 7" 9.5" 1" 1" Straight Straight
#3 0.11 0.375" 1 3'-0" 7" 1'-0.5" 1" 1" Straight Straight
#3 0.11 0.375" 3 9" 2" 2" 1" 1" Straight Straight
Mesh
Design contains no mesh
Interrupts
Design contains no interrupts

1'-9¾"

1'-9¾"

2"
5"
1" 2" 7½" 1½" 1½" 7½" 1¾" (5) #3
11'-6"

0.500L
5'-9"
Strand Mild
Aps, in²: 0.00 As, in²: 0.55
cgx, in: 0.00 cgx, in: 11.00
cgy, in: 0.00 cgy, in: 4.00
ex, in: 0.00
ey, in: 0.00

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 4


Page 199of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

PROJECT: LOCATION: JOB NO.:


BURNT STORE LAKES Project Location 2110

CLIENT: ENGINEER: CHECKER: DATE:


ONX SJK Checker 03/17/23

DESIGN THICKNESS 8"


DESIGN WIDTH 1'-9¾"
DESIGN HEIGHT 11'-6"

1'-9¾"
2"

8"
5"
1"

2" 7½" 1½" 1½" 7½" 1¾" (5) #3 x 11'-4"

Section View (0.50L - 5'-9")

CONCRETE MIX: CONCRETE AT RELEASE (f'ci): CONCRETE AT 28 DAYS (f'c): CONCRETE DENSITY:
Standard Mix 3500 psi 6000 psi 150 pcf
PRIMARY TOP REINFORCEMENT: (3) #3 x 11'-4"

PRIMARY BOT REINFORCEMENT: (2) #3 x 11'-4"

1'-5" 8'-8" 1'-5"


0" 4½" 1'-0¾" 4½"

1'-5" 8'-8" 1'-5"

STRIPPING & BLOCKING DETAIL


STRIP WITH: REVISION: DESIGN NUMBER:

Strip
ERECT WITH: 1
Erection

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 5


Page 200of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Loading Summary
Concentrated Load Summary
ID Type Dir Ecc, in Description
Dc Vert. -2.330 k at 11.50 ft 0.000
L Vert. -0.930 k at 11.50 ft 0.000
Dc Vert. -1.470 k at 11.50 ft 0.000
Dc Vert. -0.728 k at 11.50 ft 0.000
L Vert. -0.634 k at 11.50 ft 0.000

Distributed Load Summary


ID Type Dir Description
Wp Horz. -0.115 k / ft at 0.00 ft to -0.115 k / ft at 11.50 ft
Ws Horz. 0.152 k / ft at 0.00 ft to 0.152 k / ft at 11.50 ft
SW Vert. -0.136 k / ft at 0.00 ft to -0.136 k / ft at 11.50 ft Self Weight

Point Moment Summary


Design contains no point moments

Load Patterns Summary


ID Wind Soil Loads Seismic Loads Live Loads
All Left Right L-R R-L
Pressure Suction External Internal Positive Negative
Alternate Alternate
1 ✓ - - - - - ✓ - - - -
2 - ✓ - - - - ✓ - - - -

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 6


Page 201of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Project Information Panel Properties


Project: BURNT STORE LAKES Location: Project Location Date: 03/17/23 f'ci: 3.5 ksi f'c: 6.0 ksi Δlim: 0.92 in
Client: ONX Designer: SJK Job #: 2110 Δ T: 30.0 F° Initial Bow: 0.0 in Δ Max: 0.14/-0.10 in
Description: Design Type D-Run4
Specification: ACI 318-14, PCI Design Handbook 8ᵗʰ Edition

Loading [ ID - Load Case - Direction - Magnitude (k / plf) ] Ultimate Reactions (Elevation, Magnitude (k), Direction)
Dy 2.33 Ly 0.93 Dy 1.47 Dy 0.73 Ly 0.63 W1 Wp 115.0 0" 0.91 → 0" 9.81 ↓ 0" 0.69 ←
W2 Ws 152.0 11'-6" 0.91 → 11'-6" 0.69 ←

Stripping Interaction Diagram (Controlling Section @ 0.50L / 69 in)


Face Inserts: Qty: 4 Shear: 0.3 k Tension: 0.5 k

500
Shear Utilization: 0.11 (0.8 k / 7.7 k) Max Comp.: 101 psi / 2100 psi
Flexure Utilization: 0.21 (1.6 k-ft / 7.6 k-ft) Max Tension: 118 psi / 444 psi

400
Transportation
Shear Utilization: 0.09 (0.9 k / 10.1 k) Max Comp.: 108 psi / 3600 psi
Flexure Utilization: 0.22 (1.7 k-ft / 7.9 k-ft) Max Tension: 126 psi / 581 psi

300
Axial Capacity (k)
Stage: Erection

200
Face Inserts: Qty: 4 Shear: 0.3 k Tension: 0.5 k
Edge Inserts: Qty: 2 Shear: 0.0 k Tension: 1094.3 k 100
Shear Utilization: 0.08 (0.8 k / 10.1 k) Max Comp.: 101 psi / 3600 psi
Flexure Utilization: 0.20 (1.6 k-ft / 7.9 k-ft) Max Tension: 118 psi / 581 psi
0

Stage: In-Place
Shear LC: LC 5 - 1.2D + 1.0L + 1.0W
-100

Flexure LC: LC 7 - 0.9D + 1.0W


Shear Utilization: 0.09 (-0.9 k / -10.1 k) Max Comp.: 386 psi / 3600 psi
Flexure Utilization: 0.73 (-2.6 k-ft / -3.6 k-ft) Max Tension: 283 psi / 581 psi -20 -15 -10 -5 0 5 10 15 20
Axial Utilization: 0.09 (8.4 k/ 237.7 k) Moment Capacity (k-ft)

1'-9¾"
P1,P2,P3

11'-6"
W1

W2

0.8 0.4 0.0 400 200 0 300 150 0


Flexure Utilization Comp. Stress Tension Stress
Structural Model Front Elevation - Not to Scale (Mu/ϕMn) (psi) (psi)

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 7


Page 202of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

1 Design Parameters
1.1 Composite Section Properties
Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ
(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
1.15 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
2.30 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
3.45 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
4.60 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
5.75 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
6.90 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
8.05 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
9.20 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
10.35 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
11.50 21.75 8.00 130.50 10.88 3.67 856 5145 6000 0.00 0.00
1.2 Non-composite Section Properties
Loc. Width Thickness Area CGx CGy Izz Iyy J Izy θ
(ft) (in) (in) (in²) (in) (in) (in⁴) (in⁴) (in⁴) (in⁴) (deg)
0.00 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
1.15 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
2.30 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
3.45 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
4.60 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
5.75 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
6.90 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
8.05 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
9.20 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
10.35 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00
11.50 21.75 4.00 87.00 10.88 2.00 116 3430 3546 0.00 0.00

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 8


Page 203of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Detailed Flexure Capacity


Load Combination : All Combinations

Location : 5.75' (0.500 L) - LC 7 - Controlling

0% Composite Capacity

Y
X

Cross Section
Capacity Parameters Flexure Parameters Concrete Properties
Utilization : 0.733 Pu : 4.779 k Section f'c Ec λ wc
ϕMnx : -3.553 k-ft Mx : -2.604 k-ft (psi) (ksi) (pcf)
ϕPn, Compression : 240.145 k INT 6000.0 4696.0 1.00 150.0
εcu : 0.003 in/in
EXT 6000.0 4696.0 1.00 150.0
ϕPn, Tension : -17.820 k c : 0.302 in
Rebar Properties
Pcrit : 98.808 k θ : -180.000 deg
ϕ : 0.900 Height : 8.000 in
fy : 60.0 ksi Es : 29000.0 ksi
ϕTension : 0.900 CGx : 10.875 in Mesh Properties
ϕCompression : 0.650 CGy : 3.667 in fy : ksi Es : ksi
Strand Properties
Section does not contain any strand.
Concrete Force
Method: Whitney Stress Block
β : 0.750
a : 0.226 in
Section Comp. Area Cx Cy Force
(in²) (in) (in) (k)
INT 4.923 10.875 0.113 -25.110
EXT 0.000 0.000
4.923 10.875 0.113 -25.110
Mild Tension Force

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 9


Page 204of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Area Stress
# X Y Base Developed Effective Strain Base Concrete Total Force Mxi Myi
(in) (in) (in²) (%) (in²) (10⁻³) (ksi) (ksi) (ksi) (k) (k-ft) (k-ft)
1 12.250 7.000 0.110 100.00 0.110 66.578 60.000 0.000 60.000 6.600 -1.833 0.756
2 9.250 7.000 0.110 100.00 0.110 66.578 60.000 0.000 60.000 6.600 -1.833 -0.894
3 19.750 2.000 0.110 100.00 0.110 16.879 60.000 0.000 60.000 6.600 0.917 4.881
4 10.750 2.000 0.110 100.00 0.110 16.879 60.000 0.000 60.000 6.600 0.917 -0.069
5 1.750 2.000 0.110 100.00 0.110 16.879 60.000 0.000 60.000 6.600 0.917 -5.019
10.750 4.000 0.550 100.00 0.550 60.000 0.000 60.000 33.000 -0.917 -0.344
Mild Compression Force
Sections contains no mild reinforcement in compression
Prestressed Reinforcement Force
Design contains to prestressed reinforcement
Resistance Factor Axial Capacity Convergence Check
εmax : 66.578 10⁻³ in/in ϕ : 0.900 Ag : 130.50 in² Pu /ϕ : -5.310 k

Flexure Capacity Astr : 0.550 in² Fconc : -25.110 k


Apt : 0.000 in² Fmild : 33.000 k
x Axis
fse : 0.00 ksi Fstrand : 0.000 k
Mconc : -7.436 k-ft ϕPn Comp : 240.145 k Total : 13.200 k
Mmild : -0.917 k-ft ϕPn Tens : 17.820 k
Mstrand : 0.000 k-ft
Plain Concrete Strength
Mnx : -8.352 k-ft ϕMnx : 1.230 k-ft

ϕMnx : -7.517 k-ft

ϕMn vs ϕPn
Mn vs Pn
500

Demand ⬤
400 300
Axial Capacity (k)
200100
0
-100

-20 -15 -10 -5 0 5 10 15 20


Moment Capacity (k-ft)
PM Diagram
(Loading angle fixed at 180.00 deg)

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 10


Page 205of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

2.1 In-Place Strength Summary


All Combinations
2.1.1 Reaction Forces
Out-of-plane
Location Towards Interior Towards Exterior
0" 0.91 k 0.69 k
11'-6" 0.91 k 0.69 k
2.1.2 Flexure
2.1.2.1 Summary Table
Loc. Util. Mu Φ ΦMn Mcr Pu ΦPn c θ As A's Aps Loss d
(ft) (k-ft) (k-ft) (k-ft) (k) (k) (in) (deg) (in²) (in²) (in²) (%) (in)
0.00 0.00 0.0 0.65 1.4 3.1 8.5 230.7 0.16 0.0 0.00 0.00 0.00 0.00 0.00
0.57 0.22 -0.5 0.90 -2.3 -1.0 5.4 237.7 0.19 180.0 0.27 0.00 0.00 0.00 4.00
1.15 0.26 -0.9 0.90 -3.6 -1.0 5.3 240.1 0.31 180.0 0.55 0.00 0.00 0.00 4.00
1.72 0.37 -1.3 0.90 -3.6 -1.0 5.3 240.1 0.31 180.0 0.55 0.00 0.00 0.00 4.00
2.30 0.46 -1.7 0.90 -3.6 -1.0 5.2 240.1 0.31 180.0 0.55 0.00 0.00 0.00 4.00
2.87 0.54 -2.0 0.90 -3.6 -1.0 5.1 240.1 0.31 180.0 0.55 0.00 0.00 0.00 4.00
3.45 0.61 -2.2 0.90 -3.6 -1.0 5.1 240.1 0.31 180.0 0.55 0.00 0.00 0.00 4.00
4.02 0.66 -2.4 0.90 -3.6 -1.0 5.0 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
4.60 0.70 -2.5 0.90 -3.6 -1.0 4.9 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
5.17 0.72 -2.6 0.90 -3.6 -1.0 4.8 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
5.75 0.73 -2.6 0.90 -3.6 -1.0 4.8 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
6.32 0.73 -2.6 0.90 -3.5 -1.0 4.7 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
6.90 0.71 -2.5 0.90 -3.5 -1.0 4.6 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
7.47 0.67 -2.4 0.90 -3.5 -1.0 4.6 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
8.05 0.62 -2.2 0.90 -3.5 -1.0 4.5 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
8.62 0.56 -1.9 0.90 -3.5 -1.0 4.4 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
9.20 0.48 -1.7 0.90 -3.5 -1.0 4.4 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
9.77 0.38 -1.3 0.90 -3.5 -1.0 4.3 240.1 0.30 180.0 0.55 0.00 0.00 0.00 4.00
10.35 0.27 -0.9 0.90 -3.5 -1.0 4.2 240.1 0.29 180.0 0.55 0.00 0.00 0.00 4.00
10.92 0.24 -0.5 0.90 -2.1 -1.0 4.1 237.7 0.17 180.0 0.27 0.00 0.00 0.00 4.00
11.50 0.00 0.0 0.65 1.0 3.2 6.3 230.7 0.12 0.0 0.00 0.00 0.00 0.00 0.00
2.1.3 Shear
2.1.3.1 Summary Table
Loc. Util Vu ϕVn Vc Vs Req b wd Av Min
(ft) (k) (k) (k) (k) (in²) (in²/ft)
0.00 0.09 -0.9 10.1 -13.5 0.0 0.0 0.190
0.57 0.08 -0.8 10.4 -13.9 0.0 87.0 0.190
1.15 0.07 -0.7 10.4 -13.9 0.0 87.0 0.190
1.72 0.06 -0.6 10.4 -13.9 0.0 87.0 0.190
2.30 0.05 -0.5 10.4 -13.9 0.0 87.0 0.190
2.87 0.04 -0.5 10.4 -13.9 0.0 87.0 0.190
3.45 0.03 -0.4 10.4 -13.9 0.0 87.0 0.190
4.02 0.03 -0.3 10.4 -13.9 0.0 87.0 0.190
4.60 0.02 -0.2 10.4 -13.9 0.0 87.0 0.190
5.17 0.01 -0.1 10.4 -13.9 0.0 87.0 0.190
5.75 0.00 0.0 10.6 14.1 0.0 87.0 0.190
6.32 0.01 0.1 10.6 14.1 0.0 87.0 0.190
6.90 0.02 0.2 10.6 14.1 0.0 87.0 0.190
7.47 0.03 0.3 10.6 14.1 0.0 87.0 0.190
8.05 0.04 0.4 10.5 14.1 0.0 87.0 0.190
8.62 0.04 0.5 10.5 14.1 0.0 87.0 0.190
9.20 0.05 0.6 10.5 14.0 0.0 87.0 0.190
9.77 0.06 0.6 10.5 14.0 0.0 87.0 0.190
10.35 0.07 0.7 10.4 13.8 0.0 87.0 0.190
10.92 0.08 0.8 10.3 13.8 0.0 87.0 0.190
11.50 0.09 0.9 10.1 13.5 0.0 0.0 0.190
2.1.4 Axial
2.1.4.1 Summary Table

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 12


Page 206of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

Loc. Util. Pu ΦPn (C) ΦPn (T) ΦPcrit As Aps Loss Ag


(ft) (k) (k) (k) (k) (in²) (in²) (%) (in²)
0.00 0.04 9.81 230.72 0.00 ∞ 0.00 0.00 0.00 87.00
0.57 0.09 8.42 237.67 8.76 98.81 0.55 0.00 0.00 87.00
1.15 0.08 8.31 240.14 17.82 98.81 0.55 0.00 0.00 87.00
1.72 0.08 8.20 240.14 17.82 98.81 0.55 0.00 0.00 87.00
2.30 0.08 8.09 240.14 17.82 98.81 0.55 0.00 0.00 87.00
2.87 0.08 7.98 240.14 17.82 98.81 0.55 0.00 0.00 87.00
3.45 0.08 7.87 240.14 17.82 98.81 0.55 0.00 0.00 87.00
4.02 0.08 7.76 240.14 17.82 98.81 0.55 0.00 0.00 87.00
4.60 0.08 7.65 240.14 17.82 98.81 0.55 0.00 0.00 87.00
5.17 0.08 8.97 240.14 17.82 117.26 0.55 0.00 0.00 87.00
5.75 0.08 8.87 240.14 17.82 117.26 0.55 0.00 0.00 87.00
6.32 0.07 8.78 240.14 17.82 117.26 0.55 0.00 0.00 87.00
6.90 0.07 8.69 240.14 17.82 117.26 0.55 0.00 0.00 87.00
7.47 0.07 8.59 240.14 17.82 117.26 0.55 0.00 0.00 87.00
8.05 0.07 8.50 240.14 17.82 117.26 0.55 0.00 0.00 87.00
8.62 0.07 8.40 240.14 17.82 117.26 0.55 0.00 0.00 87.00
9.20 0.07 8.31 240.14 17.82 117.26 0.55 0.00 0.00 87.00
9.77 0.07 8.22 240.14 17.82 117.26 0.55 0.00 0.00 87.00
10.35 0.07 8.12 240.14 17.82 117.26 0.55 0.00 0.00 87.00
10.92 0.07 8.03 237.67 8.76 117.26 0.55 0.00 0.00 87.00
11.50 0.03 7.94 230.72 0.00 ∞ 0.00 0.00 0.00 87.00

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 13


Page 207of 248
Eriksson Wall v4.2.0 Licensee: ONX INC 3/31/2023 5:38 PM

2.1.1 In-Place Service Summary


All Combinations
2.1.1.1 Tension
2.1.1.1.1 Summary Table
Exterior Interior
Location Tension Cracking Tension Cracking M P
(ft) (psi) (psi) (psi) (psi) (k-ft) (k)
0.0 0.0 580.9 0.0 580.9 0.00 6.1
0.6 19.1 580.9 0.0 580.9 -0.29 3.6
1.1 73.9 580.9 0.0 580.9 -0.55 3.6
1.7 122.3 580.9 0.0 580.9 -0.79 3.5
2.3 164.5 580.9 0.0 580.9 -0.99 3.5
2.9 200.2 580.9 0.0 580.9 -1.16 3.4
3.4 229.5 580.9 0.0 580.9 -1.30 3.4
4.0 252.5 580.9 0.0 580.9 -1.41 3.3
4.6 269.0 580.9 0.0 580.9 -1.48 3.3
5.2 279.1 580.9 0.0 580.9 -1.53 3.2
5.7 282.8 580.9 0.0 580.9 -1.54 3.2
6.3 280.0 580.9 0.0 580.9 -1.53 3.1
6.9 270.9 580.9 0.0 580.9 -1.48 3.1
7.5 255.3 580.9 0.0 580.9 -1.40 3.0
8.0 233.4 580.9 0.0 580.9 -1.29 3.0
8.6 205.1 580.9 0.0 580.9 -1.16 3.0
9.2 170.4 580.9 0.0 580.9 -0.99 2.9
9.8 129.4 580.9 0.0 580.9 -0.78 2.9
10.3 82.2 580.9 0.0 580.9 -0.55 2.8
10.9 28.6 580.9 0.0 580.9 -0.29 2.8
11.5 0.0 580.9 0.0 580.9 0.00 4.5
2.1.1.2 Total Compression
2.1.1.2.1 Summary Table
Exterior Interior
Location Comp. Limit Comp. Limit M P
(ft) (psi) (psi) (psi) (psi) (k-ft) (k)
0.0 88.0 3600.0 88.0 3600.0 0.00 7.7
0.6 38.4 3600.0 130.6 3600.0 -0.30 6.0
1.1 9.9 3600.0 184.8 3600.0 -0.56 5.9
1.7 0.0 3600.0 232.6 3600.0 -0.80 5.9
2.3 0.0 3600.0 274.0 3600.0 -1.00 5.8
2.9 0.0 3600.0 308.9 3600.0 -1.18 5.7
3.4 0.0 3600.0 337.3 3600.0 -1.32 5.6
4.0 0.0 3600.0 359.2 3600.0 -1.43 5.5
4.6 0.0 3600.0 374.5 3600.0 -1.51 5.5
5.2 0.0 3600.0 383.3 3600.0 -1.55 5.4
5.7 0.0 3600.0 385.6 3600.0 -1.57 5.3
6.3 0.0 3600.0 381.3 3600.0 -1.55 5.2
6.9 0.0 3600.0 370.5 3600.0 -1.50 5.2
7.5 0.0 3600.0 353.2 3600.0 -1.42 5.1
8.0 0.0 3600.0 329.3 3600.0 -1.31 5.0
8.6 0.0 3600.0 299.1 3600.0 -1.17 4.9
9.2 0.0 3600.0 262.4 3600.0 -1.00 4.8
9.8 0.0 3600.0 219.3 3600.0 -0.80 4.8
10.3 0.0 3600.0 169.8 3600.0 -0.56 4.7
10.9 22.4 3600.0 114.1 3600.0 -0.30 4.6
11.5 70.0 3600.0 70.0 3600.0 0.00 6.1
2.1.1.3 Deflection
2.1.1.3.1 Summary Graph Legend
Deflection
0.50

Allowable
Deflection, in

Max Deflection: 0.137 in


0.00

Min Deflection: -0.104 in


-0.50

0 14 28 41 55 69 83 97 110 124 138


Location, in:

Type D-Run -4.ewf Copyright © 2017-2021 Eriksson Software pg. 15


Page 208of 248
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : LATTICE GIRDER DESIGN CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter H.1

LATTICE GIRDER DESIGN

Page 209of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : LATTICE GRIDER DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Lattice grider design Capcity check:


No contact with concrete to concrete, shear transferred by Lattice grider.

Material propeties
Grade of stainless steel, Fy = 60 Ksi
Density of concrete = 0.15 Kcf
Strength Reduction factor(flexure) ɸ = 0.9 (ACI318:19-T21.2.1)
Strength Reduction factor(shear) ɸ = 0.75 (ACI318:19-T21.2.1)

Geometry of panels
Maximum length of panel L = 22.5 ft (Critical panel size
Height of panel H = 11.42 ft considered)
Internal Thickness of panel Ti = 0.33 ft 4'' thick
External thickness of panel Te = 0.17 ft 2'' thick
insulation thickness = 0.17 ft 2'' thick

Loading detail
Weight of panel = 19.27 kips
Wind load on wall = 80 psf (Wall panel is checked for the Maximum wind
Area of wind load =L x H = 256.95 ft² 22.5*11.42 load of 80 psf conservatively)
Total wind load = 32.890 kips 80*256.95*1.6

Lattice grider detail Vu=


Spacing of lattice grider = 3 ft 19.3 kips
No of legs per lattice 8 in = 17 Nos
No of lattice per panel, n = 136 Nos 22.5/3*17
Dia of lattice grider, d = 0.2 in
Total factored shear, Vu =0.14*1.4 = 26.98 kips 19.27*1.4

Shear friction check for self weight of panel


Angle of lattice grider, α = 6.82
Area of lattice grider, Avf = 0.0314 in²
For normal weight concrete, λ = 1 (ACI318:19-T19.2.4)
Frictional factor, µ =1*0.7 = 0.7 (ACI318:19-T22.9.4.2)
µ sin α = 0.08
cos α = 0.99

shear capacity lattice, Vn = Avf x fy x (µ sin α + cos α ) (ACI318:19-Cl:22.9.4.3)


= 2.03 kip
ɸ Vn = 207.06 kip 2.03*0.75*136

fVn > Vu 207.06 kips > 26.98 kips SHEAR CHECK IS OK →




Tension capacity check for Wind load due to Suction →
80 psf

Tension capcity , ɸ Tn = Avf x fy x ɸ x n →


= 230.60 kip →

Wind load on wall due to suction, Tu = 32.89 kip →



fTn > Tu 230.6 kips > 32.89 kips TENSION CHECK IS OK →

Page 210of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : LATTICE GRIDER DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

CHECK FOR COMPOSITE ACTION USING LATTICE GIRDER:


(As per PCI Committe Report Design Example A4.Fully Composite Panel)

Tension Force Transfer (Tu):

Tu = n x Fy x As

As = Area of Steel used in Tension Face


n = Number Vertical bars used in Tension side of Panel

Tu = 23 x 0.11 in.sq x 60ksi


= 151.8 kip Governs

Compression Force (Cu) :

Cu = 0.85 x F'c x t x w

t = Thickness of Wythe in Compression Face


w = Width of Panel Considered

Cu = 0.85 x 6 ksi x 2" x 276"


= 2815.2 kip

** Provide Wythe Interconnectors to resist 151.8 KIP Ultimate in Each Height of Panel

Horizontal Interface Capcity required = 151.8 kip

Horizontal Interface Capcity Provided = 207.06 kip > 151.80 kip

Therefore 100% Composite action can be achieved by using Lattice Girder with Spacing 3'-0" o.c

Page 211of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : CONCRETE RUPTURE CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter H.2

CONCRETE RUPTURE CHECK

2" Exterior Wythe Rupture Check for wind Load with Lattice Girder
spacing upto 3 feet & 6000 psi Concrete strength

Page 212of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : CONCRETE RUPTURE CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

CONCRETE RUPTURE CHECK


2" Exterior Wythe Rupture Check for wind with Lattice Girder spacing upto 3 feet

design reference from PCI chapter-8.3(fig-8.3.1)

Material property data:


Grade of concrete at stripping,fc' = 6000 Psi
Density of concrete = 0.15 Kip/ft³

Slab Geometry data:


Span Length of wall, L = 120 in Maximum span b/w Lattice is considered 10.00ft
Tributary Width of wall, a = 12 in Critical Trib. Width for Wind is taken 1.00ft
Thickness of precast wall, t = 2 in 0.17ft
Selfweight of precast slab, w = 0.025 Kip/ft²
Equivalent load multiplier = 1 (T-8.3.1) (at Serviceability case)
Concrete strength factor,λ = 1

Loading detail
(Wall panel is checked for the Maximum wind load of
Wind load on wall = 80 psf 80psf conservatively)
Area of wind load =L x H = 10 ft² 1*10
Tributary Width of wall, a = 1 ft
Total wind load = 0.080 klf 80*1/1000

M
actualTensile stress fa,b =
S

Moment calculation
Critical Moment from Etabs = 0.82 Kip-in
Section modulus ,Sa = bt²/6 = 8 in³
Actual tensile stress , fa = 0.10 Ksi
Allowable tensile stress = 5λ√fc' = 0.39 Ksi

0.10 < 0.39 Hence no crack

Page 213of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : CONCRETE RUPTURE CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Lattice Spacing Analysis using etabs:

Note: Assumed 10 ft Length Wall with Lattice Spacing 3 ft o.c for Beam Analysis

Loading Diagram

Shear force and Bending moment Diagram

Page 214of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : PRECAST CONNECTION DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter J

Precast connecion design

J.1 - Foundation to Wall conection Design

J.2 - Beam to Wall connection design

Page 215of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : DIAPHRAGM CONNECTION
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter J.1

Foundation to Wall conection


Design

Page 216of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : OVERTURNING ANALYSIS
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

PIER ID : P7
Load case considered- Envelope - ULS
K.2 Overturning check is done for critical wall pier from Etabs result Case-1
1.0 MATERIAL PROPERTIES
Grade of concrete, F'c = 6 ksi
Grade of steel, fy = 60 ksi
Unitweight of concrete = 150 pci

2.0 WALL DATA


Length of wall pier from etabs, L = 26.1 ft
Thickness of wall, t = 6 in (0.50ft)

3.0 ETABS OUTPUT


Crtical load combination :
Shear force on wall, Vu = 6.37 kip
Refer below table
Axial force on wall, P = 71.0 kip
for Pier Forces
Moment on wall, Mu = 57.3 kip-ft

4.0 FORCES ON WALL


Area, A = L*t = 13.04 ft²
Section Modulus, Z = L²*t/6 = 56.7 ft³

Compressive stress, Ϭ1 = P/A + Mu/Z = 6.458 ksf

Tension stress, Ϭ2 = P/A - Mu/Z = 4.435 ksf

STRESS CURVE

L
Ϭ1
+

- Ϭ2

Page 217of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : OVERTURNING ANALYSIS
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Tension = Compression ( ie .) Ϭ1/(L-x) = Ϭ2/x

Neutral axis , x = Ϭ2*L / (Ϭ1+Ϭ2) = 57.2 ft


Max Tension, Nu = 0.5*x*Ϭ2*t = 0 kip No uplift

Note: Tension is negligable,minimum Tesion requirement shall be sufficed

5.0 MINIMUM TENSION CAPACITY CHECK

Required tension force from critical pier,Tu = 0 kip


Tension capacity required for one dowel, Tu = 10 kip (PCI-7th edtion-4.3.2)
Provided tension capacity,Tn = 10.8 kip
Refer Following connection Design
detail

Tu < ɸTn Hence ok maximum tension considered

Page 218of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : OVERTURNING ANALYSIS
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

PIER ID : P16
Load case considered- Envelope - ULS
K.2 Overturning check is done for critical wall pier from Etabs result Case-2
1.0 MATERIAL PROPERTIES
Grade of concrete, F'c = 6 ksi
Grade of steel, fy = 60 ksi
Unitweight of concrete = 150 pci

2.0 WALL DATA


Length of wall pier from etabs, L = 69.2 ft
Thickness of wall, t = 6 in (0.50ft)

3.0 ETABS OUTPUT


Crtical load combination :
Shear force on wall, Vu = 8.80 kip
Refer below table
Axial force on wall, P = 94.8 kip
for Pier Forces
Moment on wall, Mu = 512 kip-ft

4.0 FORCES ON WALL


Area, A = L*t = 34.575 ft²
Section Modulus, Z = L²*t/6 = 398.5 ft³

Compressive stress, Ϭ1 = P/A + Mu/Z = 4.026 ksf

Tension stress, Ϭ2 = P/A - Mu/Z = 1.456 ksf

STRESS CURVE

Ϭ1
+

L - Ϭ2

Page 219of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : OVERTURNING ANALYSIS
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Tension = Compression ( ie .) Ϭ1/(L-x) = Ϭ2/x

Neutral axis , x = Ϭ2*L / (Ϭ1+Ϭ2) = 39.2 ft


Max Tension, Nu = 0.5*x*Ϭ2*t = 0 kip No uplift

Note: Tension is negligable,minimum Tesion requirement shall be sufficed

5.0 MINIMUM TENSION CAPACITY CHECK

Required tension force from critical pier,Tu = 0 kip


Tension capacity required for one dowel, Tu = 10 kip (PCI-7th edtion-4.3.2)
Provided tension capacity,Tn = 10.8 kip
Refer Following connection Design
detail

Tu < ɸTn Hence ok maximum tension considered

Page 220of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : SHEAR FRICTION DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT -

In plane Shear friction capacity check


Concrete placed agianest hardened concrete,not intentionally roughened. Pier ID P7
In plane shear capacity have checked for critical wall pier from Etabs
Material propeties 6''
Grade of concrete , f'c = 6 Ksi
Pdl
Grade of stainless steel, Fy = 60 Ksi Vu
Density of concrete = 0.15 Kcf
Strength Reduction factor(flexure) ɸ = 0.9 (ACI318:19-T21.2.1)
ɸ =

Precast wall
Strength Reduction factor(shear) 0.75 (ACI318:19-T21.2.1)

Force calculation
Shear force from Etabs, Vu max = 6.37 kip
Pier length in etabs,V2 = 26.08 ft
Actual precast wall length,L = 26.08 ft
Dead load from Etabs on pier,P = 63.9 kip 0.9DL
Shear force on precast wall, Vu = 6.37 6.368/26.08*26.08 (actual precast wall forces)
Dead load on actual precast wall,Pdl = 63.9 63.9162/26.08*26.08

Shear friction check for Dead load (ACI318-14,22.9.4.5)


For normal weight concrete, λ = 1 (ACI318:19-T19.2.4)
Frictional factor, µ =1*0.6 = 0.6 (ACI318:19-T22.9.4.2)
Shear capacity from dead load, ɸVn = 28.76 kip 0.75*0.6*63.9162

Vu max = 6.4 kip < ɸVn = 28.8 kip Hence ok, Nominal connection to be provided

Shear capacity of concrete in the shear plane (ACI318-14,T-22.9.4.4)


Concrete placed agianest hardened concrete,not intentionally roughened.
Length of Shear plane section, L = 26.08 ft
Width of shear plane section, B = 0.5 ft
Height of shear section,H = 9.5 ft
Area of shear resisting section, Ac = 13.04 ft² 26.08*0.5

a) Vn max = 0.2 x f'c x Ac = 2253.31 Kip

b) Vn max = (480+0.08f'c)Ac = 1802.65 Kip

c) Vn max = 800Ac = 1502.21 Kip

Vu max = 6.4 kip < ɸVn = 1502.21 kip Hence ok, Nominal connection to be provided

Page 221of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : OUT OF PLANE SHEAR DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT-

Out of plane shear force calculation for external wall - PIER ID - P7


Out of plane shear force calculation (refer wind Load calculation sheet-Chapter C)

Length of Shear plane section, L = 26.1 ft


Total story Height of Wall, H = 12.5 ft
story Height of Each Wall, h1 = 12.5 ft
Expousre area of wind = LxH = 326 ft² 26.08*12.5

Wind pressure on wall = 53.30 psf (for exposre area of wind 326ft²)
Wind suction on wall = 61.00 psf (for exposre area of wind 326ft²)
Slab lvl-1
Vu2
H=Vu2 shear
Wind force on wall @ level-1 slab,
tributary
Pw =L x Max(Wp,Ws) = 1.59 Kip/ft MAX(53.3,61)*26.08 height

Precast wall
Wind force on foundation joint, Vu1 h1
Vu1 =pw*h1/2 = 9.94 Kip 1.59*12.5/2

Wind force on wall joint, Vu2 Foundation lvl


Vu1
Vu2 =pw*H/2 = 9.94 Kip 1.59*12.5/2

Page 222of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : FOUNDATION CONNECTION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

K.2: Precast wall to foundation Wall to foundation connection


Material propeties
Grade of Rebar, Fy = 60 Ksi (A706 rebar shall be used)
Grade of steel, Fs = 36 Ksi
Density of concrete = 0.15 Kcf
Connection design is applicable for PAP005B,
Strength Reduction factor(steel) ɸ = 0.9 (PCI-6.2.1.3)
PAG003C and PAG003E.
Strength Reduction factor(stud) ɸ = 0.65 (PCI-6.2.1.3)
Weld stress ,fex = 70 Ksi
Tensile strength of stud, fut = 65 Ksi
Negative Value Hence No shear requirement
Lateral force calculation Maximum shear force is
In plane Shear force =,Hu = -22.39 kip Refer shear friction design calc taken for connection design
out of Plane shear-Vu (Wind), = 9.94 kip Refer out of plane design calc Inplane/out of plane shear
force which is maximum
Span of the wall,L = 26.08 ft
No of connection at each panels, Nc = 2 Nos Minimum 2 connections

Steel plate Property-(PAG003A & PAP006C) Steel Square bar Property(weld plate)
Length of plate, Lp = 6 in Length of plate, Lp = 6 in
Width of plate, Bp = 4 in Width of plate, Bp = 1 in
Thickness of plate, tp = 0.25 in Thickness of plate, tp = 0.25 in
No of plate = 1 Nos No of plate = 1 Nos

Stud Property (PAP006C and PAG003A)

Dia of stud used, do = 1/2 in (PAG003C & PAP005B)


Area of stud, Ase = 0.2 in² (PCI-Table-6.5.2)
No of stud in Each connection = 2 Nos
Dia of rebar used, do = #4 (PAG003E)
Area of Rebar, As = 0.2 in²
No of rebar in Each connection = 4 Nos

Load checks

Tensile strength = 10 Kip Structural integrity requirement(ACI 318-19, 16.2.4.3)


required/connection,Tu ɸ = 0.75 (for tension)

out of Plane shear strength


required/conx,Hu = 1.42 kip
Maximum Connx. spacing Provided = 8 ft
No of connection Provded, Nc = 7 Nos (Refer Foundation Layout for number of connections)

Tension capacity checks

Area of rebar used , As = 0.2 in² (PAG003A)


Area of stud used , Ase = 0.2 in² (PAP006C)
tensile strength of Rebar provided/Connection,Tn = ɸ Fy x As x n = 21.6 (0.9*60*0.2*4)
tensile strength of stud provided/Connection,Tns = ɸ Fy x As x n = 19.5 (0.75*65*0.2*2)

Stud capacity fTns > Tu 19.5 kips > 10.3 kips TENSION CHECK IS OK
(Refer Stud Analysis for shear capacity of Studs)

Page 223of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : FOUNDATION CONNECTION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

Nominal spacing of diaphragm connections (ACI-318:19, 16.2.5.1)


S-allow S-pro
Allowable spacing each connections = 10 ft PROVIDED SPACING IS
10ft > 8ft
Spacing provided = 8 ft OK

Shear capacity checks

Embedded plate Shear capacity Check (PCI-Design Aid 6.6.2)

Direct Shear capacity fVn/Hn = f 0.6*Fs*n*Nc (Lp x tp) = (36*0.9*6*0.25*1*0.6) = 29.16 kips

fVn/Hn > Vu 29 kips > 1.4 kips SHEAR CHECK IS OK

In plane Plate Bending capacity (Phi Hn):

t x b
Size of Plate: 0.25 x 6

Area of Plate: = 1.5 in^2

eccentricity: = 1.5 in

Section modulus-Z: txbxb = 2.25 in^3


4

fHn x e = fVn x Fy x Z

fH n = f x Fy x Z = 48.6 kips
e
fVn > Vu 49 kips > 1.4 kips IN PLANE SHEAR CHECK IS OK

out of plane Plate Bending capacity (Phi Vn):

t x b
Size of Plate: 0.25 x 6

Area of Plate: = 1.5 in^2

eccentricity: = 1.5 in

Section modulus-Z: bxtxt = 0.094 in^3


4

fVn x e = fVn x Fy x Z

fVn = f x Fy x Z = 2.03 kips/Connection x 7 (Number of Connx.)


e
= 14.18 kips
fVn > Vu 14 kips > 1.4 kips OUT OF PLANE SHEAR CHECK IS OK

Weld design-E70 weld (PCI - Design Aid 6.15.2)


Weld at number of side = 1
Size of weld (Fillet Weld) = (thick x Length) x 1 3/16'' x 6'' x 1

Shear/Tension capacity of weld Tn/Vn = 6'' x 4.18 kip/in. x1 = 25 kips


Actual shear force Tu = 10.3 kips

fTn > Tu 25 kips > 10.3 kips WELD THICKNESS IS OK

Shear capacity of Square bar(weld plate) f = 0.75


Shear capacity fVn = f 0.6*Fy*As*n = (36*0.75*0.25*1*6*0.6) = 24.30 kips

Page 224of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : FOUNDATION CONNECTION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

fVn > Vu 24 kips > 1.4 kips SHEAR CHECK IS OK

Stud shear capacity check (PAG003E & PAG003C) (PCI-Design Aid 6.5.2)
Shear capacity fVs = f Fut (Ase)*n*Nc = (0.65*0.2*65*2) = 16.90 kips

fVs > Vu 17 kips > 1.4 kips SHEAR CHECK IS OK

Shear capacity of Embedded Rebar (PAP005B) f = 0.75


Shear capacity fVn = f 0.6*Fy*As*n = (60*0.75*0.2*4*0.6) = 21.60 kips

fVn > Vu 22 kips > 1.4 kips SHEAR CHECK IS OK

Capacity of Each connection:

out of Plane Shear, (Vu) = 1.4 kips


Shear capacity of connection, fVn = 14.2 kips MIN(16.9Kip,24.3Kip,14.175Kip)

fVn > Vu 14.2 kips > 1 kips SHEAR CHECK IS OK

In Plane Shear, (Hu) = 0.0 kips


Shear capacity of connection, fHn = 17 kips MIN(21.6Kip,16.9Kip,24.3Kip,48.6Kip)

fHn > Hu 16.9 kips > 0 kips SHEAR CHECK IS OK

Tension, (Tu) = 10.3 kips MAX(10.2857142857143,10)


Tension capacity of connection, fTn = 19.5 kips MIN(21.6Kip,19.5Kip,24.3Kip)

fVn > Vu 19.5 kips > 10 kips TENSION CHECK IS OK

Refer Following sheets for STUD analysis

at Exterior Face Wall Locations at Interior Face Wall Locations

Page 225of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
FL 33314. TITLE : FOUNDATION CONNECTION DESIGN
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com
STRUCTURAL CALCULATION REPORT

at Interior Wall Locations

Foundation to wall connection design

Page 226of 248


Onx Homes India Pvt Ltd BY: SHEET OF .
Foundation connection-J.1 (Tension) DATE: 03-17-2023

---------------------------------- DESIGN DATA


----------------------------------- Free Edges of the Concrete
Design : PCI Design Handbook, 8th Ed.
Criteria
H.A.S. : Type = Custom Direction of Load
Properties ds = 0.500 in dh = 1.000 in
le = 4.000 in As = 0.196 in2 de4
fy = 60.0 ksi fu = 80.0 ksi
Plate Thk = 0.250 in
No. of : X-cols = 1 Y-rows = 2 Y2
Studs Total = 2
Edge dist. : de1 = 4.000 in de3 = 10.000 in No. of Y1
Stud Spac'g Y1 = 3.000 in Y Rows. evx
de2 = 2.000 in de4 = 12.000 in
Fig. 6.5.2, PCI Hdbk (8th Ed) Case = 3 de3
Y-rows included in tension group = 2
Load enx = 0.00 in eny = 0.00 in
Eccentr'y evx = 0.00 in
Concrete Member Thickness = 6.00 in de1 X1 X2 de2
No. of X Cols
Material : f'c = 6.00 ksi  = 1.00
Properties Concrete = Normal Wt.
 factors : Tension: s = 0.75 c = 0.70
Shear : s = 0.65 c = 0.70
Pullout / Pryout : p = 0.70
Seismic application is not specified
Tension/Shear Modifiers : No Cracking at service load level (Fig 6.5.4)
NO Supplementary Reinf. for Tension or Shear Loads (§ 6.2.1.2)

Applied : Vu = 10.3 k Nu = 2.1 k


Loads tail = 0.90
------------------------------------ OUTPUT ------------------------------------
A) Tension capacity for group of 2 studs; s = 0.75; c = 0.70
Steel Stud Strength : Ns = 0.75 * 31.42 = 23.6 k (Eq 6-4)
Concrete Breakout Strength (1) : Ncbg = 0.70 * 9.34 = 6.5 k (Eq 6-6)
Concrete Pullout Strength (2) : Nph = 0.70 * 79.17 = 55.4 k (Eq 6-10*)
Concrete Side Face Blowout (3) : Nsb (Not Calculated) (Eq 6-11)

Group tensile strength based on:


(1) Projected Surface Area, AN = 92.25 in2 (Fig 6.5.1)
Modifiers : Cbs = 127.001 (Eq 6-7) Ccrb = 1.000 (§ 6.5.4.1)
edN = 0.797 (Eq 6-8) ecN = 1.000 (Eq 6-9)
(2) Single stud Nph = 39.58 k (Eq 6-10) Abrg = 0.59 in2 (§ 6.5.4.2)
Modifier : Ccrp = 1.000 (§ 6.5.4.2)
(*) No equation is given for pullout of a group. We report ng*Nph where ng is
the number of studs in the group. This is the maximum pullout. Actual
value will be lower if loading is uneven.
(3) All edge distances > 0.4 * hef (§ 6.5.4.3)

B) Shear capacity for group of 2 studs; s = 0.65; c = 0.70


Steel Stud Strength : Vs = 0.65 * 31.42 = 20.4 k (Eq 6-4)
Concrete Front Edge Breakout(1) : Vc3 (Not Calculated) (Eq 6-14)
Concrete Side Edge Breakout (2) : Vc1 = 0.70 * 14.65 = 10.3 k (Eq 6-25)
Concrete Pryout Strength (3) : Vcp (Not Calculated) (Eq 6-31)

Group shear strength based on:


(1) SED < 0.2 * BED (Eq. 6-20)
(2) One fastener in concrete Vco1 = 10.1 k
Modifiers : Cx1 = 1.000 (Eq 6-27) Cy1 = 1.454 (Eq 6-29)
Cev1 = 1.000 (Eq 6-30) Cvcr = 1.000 (Fig 6.5.4)
(3) hef > 4.5 * ds (§ 6.5.7)

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 1 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\1.Foundation PrecastEngineer.com
to wall connection\Foundation -Tension.std
Page 227of 248
Onx Homes India Pvt Ltd BY: SHEET OF .
Foundation connection-J.1 (Tension) DATE: 03-17-2023

C) Tension for plate


Stud Group Tensile Capacity e Vu
Nu = Nuh = 2.1 k
From (A), Nn = 6.5 k, group of 2
Nu/Nn = 0.32 < 1.0 O.K. Tu
D) Shear for plate
Tail bar requirements Nu
Based on user-entered load
Vu = 10.3 k, user entered
As required = Vu/(cos()*tail*fy) d j ud
Minimum As required = 0.19 in2

>>>WARNING: User-entered shear load is


greater than plate stud capacity.
Adequate tail bars must be present.
ao
The Area of steel required is based on the
assumption that the tail bars are
fully developed in compliance with § 12.2
or § 12.5 of ACI 318.

Tail bars must be welded to the plate in a manner adequate to develop


full tensile capacity of the bar prior to weld failure.

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 2 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\1.Foundation PrecastEngineer.com
to wall connection\Foundation -Tension.std
Page 228of 248
Onx Homes India Pvt Ltd BY: SHEET OF .
Foundation connection-J.1 (In plane Shear) DATE: 03-17-2023

---------------------------------- DESIGN DATA


----------------------------------- Free Edges of the Concrete
Design : PCI Design Handbook, 8th Ed.
Criteria
H.A.S. : Type = 1/2 X 4 Direction of Load
Properties ds = 0.500 in dh = 1.000 in
le = 3.688 in As = 0.196 in2 de4
fy = 51.0 ksi fu = 65.0 ksi
Plate Thk = 0.250 in
No. of : X-cols = 1 Y-rows = 2 Y2
Studs Total = 2
Edge dist. : de1 = 3.000 in de3 = 6.000 in No. of Y1
Stud Spac'g Y1 = 3.000 in Y Rows. evx
de2 = 3.000 in de4 = 12.000 in
Fig. 6.5.2, PCI Hdbk (8th Ed) Case = 3 de3
Y-rows included in tension group = 1
Load enx = 0.00 in eny = 0.00 in
Eccentr'y evx = 0.00 in
Concrete Member Thickness = 18.00 in de1 X1 X2 de2
No. of X Cols
Material : f'c = 6.00 ksi  = 1.00
Properties Concrete = Normal Wt.
 factors : Tension: s = 0.75 c = 0.70
Shear : s = 0.65 c = 0.70
Pullout / Pryout : p = 0.70
Seismic application is not specified
Tension/Shear Modifiers : No Cracking at service load level (Fig 6.5.4)
NO Supplementary Reinf. for Tension or Shear Loads (§ 6.2.1.2)

------------------------------------ OUTPUT ------------------------------------


A) Tension capacity for group of 1 studs; s = 0.75; c = 0.70
Steel Stud Strength : Ns = 0.75 * 12.76 = 9.6 k (Eq 6-4)
Concrete Breakout Strength (1) : Ncbg = 0.70 * 7.77 = 5.4 k (Eq 6-6)
Concrete Pullout Strength (2) : Nph = 0.70 * 39.58 = 27.7 k (Eq 6-10*)
Concrete Side Face Blowout (3) : Nsb (Not Calculated) (Eq 6-11)

Group tensile strength based on:


(1) Projected Surface Area, AN = 68.63 in2 (Fig 6.5.1)
Modifiers : Cbs = 132.095 (Eq 6-7) Ccrb = 1.000 (§ 6.5.4.1)
edN = 0.857 (Eq 6-8) ecN = 1.000 (Eq 6-9)
(2) Single stud Nph = 39.58 k (Eq 6-10) Abrg = 0.59 in2 (§ 6.5.4.2)
Modifier : Ccrp = 1.000 (§ 6.5.4.2)
(*) No equation is given for pullout of a group. We report ng*Nph where ng is
the number of studs in the group. This is the maximum pullout. Actual
value will be lower if loading is uneven.
(3) All edge distances > 0.4 * hef (§ 6.5.4.3)

B) Shear capacity for group of 2 studs; s = 0.65; c = 0.70


Steel Stud Strength : Vs = 0.65 * 25.53 = 16.6 k (Eq 6-4)
Concrete Corner Breakout (1) : Vc3 = 0.70 * 11.53 = 8.1 k (Eq 6-22)
Concrete Side Edge Breakout (2) : Vc1 (Not Calculated) (Eq 6-25)
Concrete Pryout Strength (3) : Vcp (Not Calculated) (Eq 6-31)

Group shear strength based on:


(1) One fastener in concrete Vco3 = 23.8 k (Eq 6-15)
Note: This is a Corner condition
Modifiers : Ch3 = 1.000 (Eq 6-18) Cvcr = 1.000 (Fig 6.5.4)
Cev3 = 1.000 (Eq 6-19) Cc3 = 0.485 (Eq 6-23)
(2) Both SED > 0.2 * BED (Eq 6-24)
(3) hef > 4.5 * ds (§ 6.5.7)

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 1 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\1.Foundation PrecastEngineer.com
to wall connection\Foundation -In plane Shear.std
Page 229of 248
Onx Homes India Pvt Ltd BY: SHEET OF .
Foundation connection-J.1 (In plane Shear) DATE: 03-17-2023

C) Tension and shear for stud groups


Tension : Nn = 5.4 k, group of 1
Shear : Vn = 8.1 k, group of 2

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 2 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\1.Foundation PrecastEngineer.com
to wall connection\Foundation -In plane Shear.std
Page 230of 248
Onx Homes India Pvt Ltd BY: SHEET OF .
Foundation connectionj.1 (out of plane Shear) DATE: 03-17-2023

---------------------------------- DESIGN DATA


----------------------------------- Free Edges of the Concrete
Design : PCI Design Handbook, 8th Ed.
Criteria
H.A.S. : Type = 1/2 X 4 Direction of Load
Properties ds = 0.500 in dh = 1.000 in
le = 3.688 in As = 0.196 in2 de4
fy = 51.0 ksi fu = 65.0 ksi
Plate Thk = 0.250 in
No. of : X-cols = 2 Y-rows = 1 Y2
Studs Total = 2
Edge dist. : de1 = 10.000 in de3 = 3.000 in No. of Y1
Stud Spac'g X1 = 3.000 in Y Rows.
evx
de2 = 12.000 in de4 = 3.000 in
Fig. 6.5.2, PCI Hdbk (8th Ed) Case = 3 de3
Y-rows included in tension group = 1
Load enx = 0.00 in eny = 0.00 in
Eccentr'y evx = 0.00 in
Concrete Member Thickness = 18.00 in de1 X1 X2 de2
No. of X Cols
Material : f'c = 6.00 ksi  = 1.00
Properties Concrete = Normal Wt.
 factors : Tension: s = 0.75 c = 0.70
Shear : s = 0.65 c = 0.70
Pullout / Pryout : p = 0.70
Seismic application is not specified
Tension/Shear Modifiers : No Cracking at service load level (Fig 6.5.4)
NO Supplementary Reinf. for Tension or Shear Loads (§ 6.2.1.2)

Applied : Vu = 1.4 k Nu = 0.0 k


Loads
------------------------------------ OUTPUT ------------------------------------
A) Tension capacity for group of 2 studs; s = 0.75; c = 0.70
Steel Stud Strength : Ns = 0.75 * 25.53 = 19.1 k (Eq 6-4)
Concrete Breakout Strength (1) : Ncbg = 0.70 * 9.81 = 6.9 k (Eq 6-6)
Concrete Pullout Strength (2) : Nph = 0.70 * 79.17 = 55.4 k (Eq 6-10*)
Concrete Side Face Blowout (3) : Nsb (Not Calculated) (Eq 6-11)

Group tensile strength based on:


(1) Projected Surface Area, AN = 86.63 in2 (Fig 6.5.1)
Modifiers : Cbs = 132.095 (Eq 6-7) Ccrb = 1.000 (§ 6.5.4.1)
edN = 0.857 (Eq 6-8) ecN = 1.000 (Eq 6-9)
(2) Single stud Nph = 39.58 k (Eq 6-10) Abrg = 0.59 in2 (§ 6.5.4.2)
Modifier : Ccrp = 1.000 (§ 6.5.4.2)
(*) No equation is given for pullout of a group. We report ng*Nph where ng is
the number of studs in the group. This is the maximum pullout. Actual
value will be lower if loading is uneven.
(3) All edge distances > 0.4 * hef (§ 6.5.4.3)

B) Shear capacity for group of 2 studs; s = 0.65; c = 0.70


Steel Stud Strength : Vs = 0.65 * 25.53 = 16.6 k (Eq 6-4)
Concrete Front Edge Breakout(1) : Vc3 = 0.70 * 6.52 = 4.6 k (Eq 6-14)
Concrete Side Edge Breakout (2) : Vc1 (Not Calculated) (Eq 6-25)
Concrete Pryout Strength (3) : Vcp (Not Calculated) (Eq 6-31)

Group shear strength based on:


(1) One fastener in concrete Vco3 = 5.5 k (Eq 6-15)
Note: This is a Front Edge condition
Modifiers : Ch3 = 1.000 (Eq 6-18) Cvcr = 1.000 (Fig 6.5.4)
Cev3 = 1.000 (Eq 6-19) Cx3 = 1.183 (Eq 6-17)
(2) Both SED > 0.2 * BED (Eq 6-24)
(3) hef > 4.5 * ds (§ 6.5.7)

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 1 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\1.Foundation PrecastEngineer.com
to wall connection\Foundation -out of plane Shear.std
Page 231of 248
Onx Homes India Pvt Ltd BY: SHEET OF .
Foundation connectionj.1 (out of plane Shear) DATE: 03-17-2023

C) Tension and shear for stud groups


Tension : Nn = 6.9 k, group of 2 e Vu
Shear : Vn = 4.6 k, group of 2
Tu
Vu
Nu

d j ud Nu

ao

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 2 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\1.Foundation PrecastEngineer.com
to wall connection\Foundation -out of plane Shear.std
Page 232of 248
TABLE: Pier Forces
Story Pier Output Case Step Type Location P V2 M3
kip kip kip-ft
Story1 P7 ULS Min Bottom 112.428 6.368 57.3363
Story1 P13 ULS Min Bottom 26.608 0.846 37.966
Story1 P7 ULS Max Bottom 63.281 10.858 21.2284
Story1 P13 ULS Max Bottom 14.976 3.737 16.7222
Story1 P1 ULS Min Bottom 5.097 10.513 16.1467
Story1 P2 ULS Max Bottom 4.019 7.224 12.6834
Story1 P10 ULS Min Bottom 38.431 6.604 9.834
Story1 P1 ULS Max Bottom 2.335 5.393 8.0606
Story1 P6 ULS Min Bottom 20.096 4.59 7.4397
Story1 P14 ULS Min Bottom 11.185 3.056 6.6483
Story1 P2 ULS Min Bottom 6.906 3.462 6.4005
Story1 P5 ULS Max Bottom 8.638 2.94 6.3863
Story1 P6 ULS Max Bottom 11.138 0.885 5.9688
Story1 P15 ULS Max Bottom 6.973 2.346 5.8037
Story1 P5 ULS Min Bottom 14.689 1.536 4.8637
Story1 P36 ULS Max Bottom 4.546 0.434 4.0838
Story1 P12 ULS Max Bottom 11.082 2.26 3.4543
Story1 P36 ULS Min Bottom 7.366 0.262 2.5919
Story1 P11 ULS Max Bottom 26.943 0.567 2.4138
Story1 P11 ULS Min Bottom 50.258 0.464 2.3036
Story1 P15 ULS Min Bottom 12.341 0.079 1.9422
Story1 P10 ULS Max Bottom 20.012 2.116 1.4747
Story1 P14 ULS Max Bottom 6.275 0.337 1.2853
Story1 P4 ULS Max Bottom 0.318 0.432 0.6516
Story1 P12 ULS Min Bottom 21.668 0.612 0.5343
Story1 P8 ULS Max Bottom 2.198 0.405 0.4691
Story1 P35 ULS Max Bottom 0.658 0.284 0.2983
Story1 P4 ULS Min Bottom 1.221 0.187 0.2773
Story1 P8 ULS Min Bottom 5.152 0.171 0.1958
Story1 P9 ULS Min Bottom 2.124 0.168 0.1907
Story1 P35 ULS Min Bottom 1.166 0.175 0.1889
Story1 P3 ULS Min Bottom 2.125 0.374 0.1002
Story1 P3 ULS Max Bottom 0.746 0.195 0.0634
Story1 P9 ULS Max Bottom 0.97 0.03 0.0227

Page 233of 248


TABLE: Pier Forces
Story Pier Output Case Step Type Location P V2 M3
kip kip kip-ft
Story1 P1 SDL+DL Bottom 3.092 6.239 9.5912
Story1 P2 SDL+DL Bottom 4.933 4.051 7.5556
Story1 P3 SDL+DL Bottom 1.037 0.267 0.0407
Story1 P4 SDL+DL Bottom 0.697 0.295 0.4409
Story1 P5 SDL+DL Bottom 10.492 0.641 0.6409
Story1 P6 SDL+DL Bottom 13.222 1.719 0.7004
Story1 P7 SDL+DL Bottom 71.018 2.095 14.5083
Story1 P8 SDL+DL Bottom 3.235 0.075 0.1047
Story1 P9 SDL+DL Bottom 1.414 0.043 0.0577
Story1 P10 SDL+DL Bottom 22.958 3.589 3.7498
Story1 P11 SDL+DL Bottom 30.031 0.049 0.0563
Story1 P12 SDL+DL Bottom 12.955 1.121 1.6517
Story1 P13 SDL+DL Bottom 17.478 1.288 22.1569
Story1 P14 SDL+DL Bottom 7.706 1.577 2.4692
Story1 P15 SDL+DL Bottom 8.384 1.074 1.7883
Story1 P35 SDL+DL Bottom 0.833 0.203 0.2131
Story1 P36 SDL+DL Bottom 5.262 0.31 2.917

Page 234of 248


TABLE: Pier Forces
Story Pier Output Case Step Type Location P V2 M3
kip kip kip-ft
Story1 P16 ULS Min Bottom 143.441 8.797 512.083
Story1 P16 ULS Max Bottom 77.062 4.88 250.8875
Story1 P18 ULS Min Bottom 58.383 1.34 86.3136
Story1 P25 ULS Max Bottom 59.471 9.115 61.6751
Story1 P17 ULS Min Bottom 80.31 2.371 58.017
Story1 P21 ULS Max Bottom 22.647 0.395 43.1514
Story1 P20 ULS Max Bottom 25.113 0.35 41.7235
Story1 P22 ULS Max Bottom 37.017 1.016 41.3492
Story1 P18 ULS Max Bottom 32.581 7.131 27.8551
Story1 P25 ULS Min Bottom 107.306 3.257 17.52
Story1 P21 ULS Min Bottom 39.088 4.089 13.5439
Story1 P19 ULS Min Bottom 25.696 3.69 13.4574
Story1 P20 ULS Min Bottom 40.657 5.222 9.4362
Story1 P19 ULS Max Bottom 14.714 2.285 8.0028
Story1 P17 ULS Max Bottom 48.679 3.912 7.585
Story1 P22 ULS Min Bottom 62.63 3.489 6.3898
Story1 P23 ULS Min Bottom 24.543 1.42 4.5282
Story1 P24 ULS Max Bottom 0.692 2.476 3.5488
Story1 P23 ULS Max Bottom 12.327 0.696 2.0314
Story1 P24 ULS Min Bottom 3.379 1.287 1.9451
Story1 P57 ULS Min Bottom 29.01 1.921 1.6298
Story1 P57 ULS Max Bottom 15.915 0.476 1.1046
Story1 P55 ULS Min Bottom 0.832 0.023 0.8074
Story1 P54 ULS Min Bottom 10.493 0.358 0.4395
Story1 P54 ULS Max Bottom 5.55 1.205 0.3235
Story1 P55 ULS Max Bottom 0.494 0.205 0.2253

Page 235of 248


TABLE: Pier Forces
Story Pier Output Case Step Type Location P V2 M3
kip kip kip-ft
Story1 P16 SDL+DL Bottom 94.773 1.65 316.3101
Story1 P17 SDL+DL Bottom 54.518 0.734 28.4476
Story1 P18 SDL+DL Bottom 37.123 3.657 44.6858
Story1 P19 SDL+DL Bottom 16.632 2.636 9.1563
Story1 P20 SDL+DL Bottom 28.691 2.103 20.1473
Story1 P21 SDL+DL Bottom 26.275 1.586 23.1761
Story1 P22 SDL+DL Bottom 41.897 1.05 19.9492
Story1 P23 SDL+DL Bottom 14.52 0.875 2.6844
Story1 P24 SDL+DL Bottom 1.848 1.541 2.2588
Story1 P25 SDL+DL Bottom 71.241 2.784 36.7642
Story1 P54 SDL+DL Bottom 6.636 0.639 0.0604
Story1 P55 SDL+DL Bottom 0.594 0.109 0.4811
Story1 P57 SDL+DL Bottom 19.195 1.302 0.2307

Page 236of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : Foundation to Wall conection Design
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter J.2

Beam to Wall connection design

Page 237of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : BEAM TO WALL CONNECTION DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT -

J.2: Precast Beam to Precast Wall Connections.

Material propeties
Grade of Rebar, Fy (A706 rebar) = 60 Ksi
Grade of steel, Fs = 36 Ksi
Weld, Fexx = 70 Ksi
Connection design is applicable for PAG003A &
Density of concrete = 0.15 Kcf
PAP005A.
Strength Reduction factor(steel) ɸ = 0.9 (PCI-6.2.1.3)
Strength Reduction factor(stud) ɸ = 0.65 (PCI-6.2.1.3) (for shear)
Strength Reduction factor(stud) ɸ = 0.75 (PCI-6.2.1.3) (for Tension)
Tensile strength of stud, fut = 65 Ksi
Geometry of Wall
Length of beam = 16.5 ft
Depth of beam = 0.67 ft
Width of beam = 3.33 ft

Loading detail
Dead load reaction from beam = 10.956 kips (refer Beam-004 (Gravity Load case Concise report
No of Connections on each end = 1 Nos Reaction detail)

Torsion force from beam, Tu 12.12 kips Due to wind suction Force
Shear force from beam, Vu 2.74 kips 25% of dead weight

Steel plate Property(PAP005A & PAG003A)


Length of plate, Lp = 6 in
Width of plate, Bp = 6 in
Thickness of plate, tp = 0.25 in

Stud PropertyPAP005A & PAG003A)


Dia of stud used, do = 1/2 in
Area of stud, Ase = 0.2 in² (PCI-Table-6.5.2)
No of studs = 2 Nos (conservatively consider only vertical studs for shear)

Plate Shear capacity Check (PCI-Design Aid 6.6.2)


Shear capacity fVn = f 0.6*Fs (Lp x tp) = (36*0.9*6*0.25*0.6) = 29.16 kips
Actual shear force Vu = 2.7 kips

fVn > Vu 29 kips > 2.7 kips SHEAR CHECK IS OK

Plate Tension capacity Check (PCI-Design Aid 6.6.2)


Tension capacity fTn = f *Fs (Lp x tp) = (36*0.9*6*0.25) = 48.60 kips
Actual Tension force Tu = 12.1 kips

fVn > Vu 49 kips > 12.1 kips TENSION CHECK IS OK


Weld design-E70 weld (PCI - Design Aid 6.15.2)
Weld at number of side = 1
Size of weld (Fillet Weld) = (thick x Length) x 1 3/16'' x 6'' x 1

Shear/Tension capacity of weld Tn/Vn = 6'' x 4.18 kip/in. x1 = 25.1 kips


Actual shear force Vu = 12.1 kips

fVn > Vu 25 kips > 12.1 kips WELD THICKNESS IS OK

Page 238of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : BEAM TO WALL CONNECTION DESIGN
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT -

Stud Tension capacity check (PCI-Design Aid 6.5.2)


Tension capacity fVs = f Fut (Ase)*n = (0.75*0.2*65*2) = 19.5 kips
Actual Tension force Vu = 12.1 kips
fVs > Vu 19.5 kips > 12.1 kips TENSION CHECK IS OK

Stud Shear capacity check (PCI-Design Aid 6.5.2)


Tension capacity fVs = f Fut (Ase)*n = (2*65*0.65*0.2) = 16.9 kips
Actual Tension force Vu = 2.7 kips
fVs > Vu 16.9 kips > 6.0 kips SHEAR CHECK IS OK

Total shear capacity of connection


Inplane Shear, (Vu) = 2.74 kips
Shear capacity of connection, fVn = 16.9 kips MIN(29.16Kip,25.1Kip,16.9Kip)

fVn < Vu 16.9 kips > 2.7 kips SHEAR CHECK IS OK

Total Tension capacity of connection


Tension force, (Tu) = 12.1 kips
Shear capacity of connection, fVn = 19.5 kips MIN(48.6Kip,25.1Kip,19.5Kip)

fTn > Tu 19.5 kips > 12.1 kips TENSION CHECK IS OK

Refer Following sheets for STUD Analysis report


Tension Cpacity, (Tu) = 12.2 kips
Shear capacity of connection, fVn = 6.9 kips

Typical Precast beam to Precast wall connection.

Page 239of 248


Onx Homes India Pvt Ltd BY: SHEET OF .
CONNECTION J.2 (Tension) DATE: 03-17-2023

---------------------------------- DESIGN DATA


----------------------------------- Free Edges of the Concrete
Design : PCI Design Handbook, 8th Ed.
Criteria
H.A.S. : Type = 1/2 X 4 Direction of Load
Properties ds = 0.500 in dh = 1.000 in
le = 3.688 in As = 0.196 in2 de4
fy = 51.0 ksi fu = 65.0 ksi
Plate Thk = 0.250 in
No. of : X-cols = 1 Y-rows = 2 Y2
Studs Total = 2
Edge dist. : de1 = 12.000 in de3 = 4.000 in No. of Y1
Stud Spac'g Y1 = 3.000 in Y Rows. evx
de2 = 12.000 in de4 = 10.000 in
Fig. 6.5.2, PCI Hdbk (8th Ed) Case = 2 de3
Y-rows included in tension group = 2
Load enx = 0.00 in eny = 0.00 in
Eccentr'y evx = 0.00 in
Concrete Member Thickness = 6.00 in de1 X1 X2 de2
No. of X Cols
Material : f'c = 6.00 ksi  = 1.00
Properties Concrete = Normal Wt.
 factors : Tension: s = 0.75 c = 0.70
Shear : s = 0.65 c = 0.70
Pullout / Pryout : p = 0.70
Seismic application is not specified
Tension/Shear Modifiers : No Cracking at service load level (Fig 6.5.4)
NO Supplementary Reinf. for Tension or Shear Loads (§ 6.2.1.2)

Applied : Vu = 12.1 k Nu = 0.0 k


Loads
------------------------------------ OUTPUT ------------------------------------
A) Tension capacity for group of 2 studs; s = 0.75; c = 0.70
Steel Stud Strength : Ns = 0.75 * 25.53 = 19.1 k (Eq 6-4)
Concrete Breakout Strength (1) : Ncbg = 0.70 * 17.49 = 12.2 k (Eq 6-6)
Concrete Pullout Strength (2) : Nph = 0.70 * 79.17 = 55.4 k (Eq 6-10*)
Concrete Side Face Blowout (3) : Nsb (Not Calculated) (Eq 6-11)

Group tensile strength based on:


(1) Projected Surface Area, AN = 145.50 in2 (Fig 6.5.1)
Modifiers : Cbs = 132.095 (Eq 6-7) Ccrb = 1.000 (§ 6.5.4.1)
edN = 0.910 (Eq 6-8) ecN = 1.000 (Eq 6-9)
(2) Single stud Nph = 39.58 k (Eq 6-10) Abrg = 0.59 in2 (§ 6.5.4.2)
Modifier : Ccrp = 1.000 (§ 6.5.4.2)
(*) No equation is given for pullout of a group. We report ng*Nph where ng is
the number of studs in the group. This is the maximum pullout. Actual
value will be lower if loading is uneven.
(3) All edge distances > 0.4 * hef (§ 6.5.4.3)

B) Shear capacity for group of 2 studs; s = 0.65; c = 0.70


Steel Stud Strength : Vs = 0.65 * 25.53 = 16.6 k (Eq 6-4)
Concrete Corner Breakout (1) : Vc3 = 0.70 * 9.89 = 6.9 k (Eq 6-22)
Concrete Side Edge Breakout (2) : Vc1 (Not Calculated) (Eq 6-25)
Concrete Pryout Strength (3) : Vcp (Not Calculated) (Eq 6-31)

Group shear strength based on:


(1) One fastener in concrete Vco3 = 17.0 k (Eq 6-15)
Note: This is a Corner condition
Modifiers : Ch3 = 0.694 (Eq 6-18) Cvcr = 1.000 (Fig 6.5.4)
Cev3 = 1.000 (Eq 6-19) Cc3 = 0.838 (Eq 6-23)
(2) Both SED > 0.2 * BED (Eq 6-24)
(3) hef > 4.5 * ds (§ 6.5.7)

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 1 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\2-beam to wall PrecastEngineer.com
connection\STUD Tension analysis - J.2.std
Page 240of 248
Onx Homes India Pvt Ltd BY: SHEET OF .
CONNECTION J.2 (Tension) DATE: 03-17-2023

C) Tension and shear for stud groups


Tension : Nn = 12.2 k, group of 2 e Vu
Shear : Vn = 6.9 k, group of 2
Tu
Vu
Nu

d j ud Nu

ao

C:\Users\Shanmukha.J\OneDrive - ONX Technologies\ Page 2 Studs V4.4.0


Desktop\C Drive Back up\ONX Projects\BURNT STORE LAKES\ ©2019 Salmons Technologies, Inc.
ETAB MODEL LOAD EXCEL\Connection Design\2-beam to wall PrecastEngineer.com
connection\STUD Tension analysis - J.2.std
Page 241of 248
PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : CONCRETE BEARING CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter K

Concrete Plain bearing check

Page 242of 248


PLF STRUCTURAL ENGINNERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE 401 DAVIE,
TITLE : CONCRETE BEARING CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengieers.com STRUCTURAL CALCULATION REPORT

1
Plain concrete bearing check : (PCI 8th Edition, Clause 5.5.1) Beam type PB-004

Material data
Grade of concrete, f'c = 6000 psi
Grade of steel, fy = 60000 psi
Density of concrete = 0.15 Kip/ft³
Strength reduction factor, ɸ = 0.65 (ACI-318-19:Table-21.2.1)
Cr = 1.0 Reinforcement is provided in direction of Nu
Concrete Density Factor, λ = 1.0 Normal Weight Concrete

3.5''
3.0'' Vu
Precast spandral beam
8.0''

A2 Nu
6.0''

A1
A1-bearing area

Precast
A2-dispersion area
Bearing area,A1 = 3in x 6in = 18.0 in² wall/column
Dispersion area,A2 = 3.5in x 8in = 28.0 in²

Shear force from beam


Total factored shear, Vu = 12.8 kip
Total dead load shear, Vudl = 11.0 kip
Total horizontal shear, Nu = 2.2 kip

Plain concrete bearing check


Shear capacity, ɸVn = ɸ Cr (0.85 f'c x A1) √(A2/A1) ≤ 1.1f'c A1 (Eq. 5-54)
ɸVn = 74.42 ≤ 118.8 kip Ok.

ɸVn > Vu = 74.42 > 12.8 kip Concrete strength is sufficient for bearing.

Page 243of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : BURNT STORE LAKES
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE, TITLE : LIFTING/HANDLING CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Chapter L

Lifting / Handling check

Page 244of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : GRANDVILL- (G+1)/SOLID WALL
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : LIFTING & HANDLING CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

5. Check for handling and stripping of 6" precast wall upto 10 feet

Stripping design reference from PCI chapter-8.3(fig-8.3.1)

Material property data:


Grade of concrete at stripping,fc' = 3500 Psi
Grade of steel,fy = 60 Ksi Longer span lifting points(b)
Grade strands,fpu = 270 Ksi
Density of concrete = 0.15 Kip/ft³ 24.84in 70.32in 24.84in

Slab Geometry data:


Span Length of wall, b = 120 in Maximum span can be used 10.00ft
Width of wall, a = 112 in
Thickness of precast wall, t = 6 in
Selfweight of precast slab, w = 0.075 Kip/ft²
Equivalent load multiplier = 1.2 (T-8.3.1)
Concrete strength factor,λ = 1

M P
Tensile stress fa,b = -
S A
strands Force calculation:
Area of prestressing strands,Ap = 0 in²
Force from strands,P = Apxfpu = 0 kip

Page 245of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : GRANDVILL- (G+1)/SOLID WALL
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : LIFTING & HANDLING CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Moment calculation
Moment at shorter direction, Mx = (w x a² /8) x 1.2 = 11.8 Kip-in
Section modulus at shorter direction,Sa = bt²/6 = 672 in³
Actual tensile stress , fa = 0.02 Ksi
Allowable tensile stress = 5λ√fc' = 0.30 Ksi

0.02 < 0.30 Hence no crack

Moment at Longer direction, My = 0.0107x w x a x b² x 1.2 = 64.7 Kip-in


Section modulus at Longer direction,Sa = at²/6 = 336 in³
Actual tensile stress,fb = 0.19 Ksi
Allowable tensile stress = 5λ√fc' = 0.30 Ksi

0.19 < 0.30 Hence no crack

Page 246of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : GRANDVILL- (G+1)/SOLID WALL
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : LIFTING & HANDLING CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

4. Check for handling and stripping of 6" precast wall above 12 feet

Stripping design reference from PCI chapter-8.3(fig-8.3.1)

Material property data:


Grade of concrete at stripping,fc' = 3500 Psi
Grade of steel,fy = 60 Ksi
Grade strands,fpu = 270 Ksi
Density of concrete = 0.15 Kip/ft³

Slab Geometry data:


Span Length of wall, b = 255 in Maximum span can be used 21.25ft
Width of wall, a = 109.2 in
Thickness of precast wall, t = 6 in
Selfweight of precast slab, w = 0.075 Kip/ft²
Equivalent load multiplier = 1.2 (T-8.3.1)
Concrete strength factor,λ = 1

M P
Tensile stress fa,b = -
S A
strands Force calculation:
Area of prestressing strands,Ap = 0 in²
Force from strands,P = Apxfpu = 0 kip

Page 247of 248


PLF STRUCTURAL ENGINEERS, INC. PROJECT : GRANDVILL- (G+1)/SOLID WALL
CA #30758
4960 SW 52ND STREET, SUITE #401 DAVIE,
TITLE : LIFTING & HANDLING CHECK
FL 33314.
O: (954)533-3237 Fax: (954) 533-2117
Email:pfiallo@plfengineers.com STRUCTURAL CALCULATION REPORT

Moment calculation
Moment at shorter direction, Mx = (w x a² /8) x 1.2 = 11.2 Kip-in
Section modulus at shorter direction,Sa = bt²/6 = 655 in³
Actual tensile stress , fa = 0.02 Ksi 0.12 N/mm2
Allowable tensile stress = 5λ√fc' = 0.30 Ksi 2.04 N/mm2

0.02 < 0.30 Hence no crack

Moment at Longer direction, My = 0.0027 x w x a x b² x 1.2 = 1.19 Kip-in


Section modulus at Longer direction,Sa = at²/6 = 228 in³
Actual tensile stress,fb = 0.005 Ksi 0.04 N/mm2
Allowable tensile stress = 5λ√fc' = 0.30 Ksi 2.04 N/mm2

0.01 < 0.30 Hence no crack

Longer span lifting points(b)

26.52in 74.46in 53.04in 74.46in 26.52in

Page 248of 248