Professional Documents
Culture Documents
BHARAT ALUMINIUM
COMAPNY LIMITED
IMS MANAGEMENT SYSTEM AUXILIARY HEADER ISOLATION AND
CHARGING
STANDARD OPERATING
PROCEDURE
STANDARDS ISO : 9001 ISO : 14001 OHSAS : 18001 ISO : 50001
CONTROL OF
OPERATIONAL
Element Name: PRODUCTION & SERVICE OPERATIONAL CONTROL OPERATIONAL CONTROL
CONTROL
PROVISION
Element Number: 7.5.1 4.4.6 4.4.6 4.5.5
MR OFFICE USE ONLY
FORMAT NO. – IMS 10 FORMAT REVISION NO.: 00 FORMAT VERSION NO.: 00 FORMAT REVISION DATE : 12.06.15
Rev. No. 00 Version No. 00 Date of Preparation: 23/03/2016 Pages: 1 of 8
SOP No: BALCO/POWER/CPP2/OPN/MP/IMS/DOC/010-AUXHDR
HEALTH,SAFETY,
STEP ENVIRONMENT
ACTIONS/OUTCOMES AND QUALITY
MESSAGES
Usage
√ √ √ √ √ √ √ X
TECHNICAL SPECIFICATIONS
SAFETY:
Designed Pr. 10 Kg/cm 2
There should be
Design Temp 400 oC no steam
Steam Pressure 6Kg/cm2 leakage
Stream Temperature 250-275 oC
1. PRE-CHECKS
BEFORE ISOLATION
HEALTH:
1. Ensure that turbine gland steam of all units is charged from Main steam of respective units. (DE) (EnMS) Ensure proper
2. HFO Atomizing steam is charged from CRH in any one unit from U#1 and U#2 and any one unit from U#3 lighting
and U#4. (FE) arrangement
3. All units mill inerting steam line is in isolated condition. (FE)
4. Ensure that in U#1 ejector is not in service and is in isolated condition. (FE)
5. Ensure that all units SCAPH is in isolated condition.(FE)
6. Ensure that pegging steam line is in isolated condition in all units. (FE)
7. Ensure that auxiliary to 3rd extraction line is in isolated condition.(FE)
2. Isolation
procedure
1. Monitoring the gland steam pressure close the auxiliary steam to gland steam isolation valve (turbine 9m) in
all units. (DE)
2. Monitoring the HFO atomising steam temperature and pressure isolate the Auxiliary steam to FOPH line
isolation valve in U#1 D/A floor. (FE) (EnMS)
3. Open drain line after I/V and drain in U#1 boiler 0m atomising line.(FE)
4. Isolate auxiliary steam header to gland steam header isolation valve in U#1 D/A floor and open drains.(FE)
5. Crack open auxiliary steam header drains in between U# 2 and 3 and 3 and 4. (FE)
6. Crack open auxiliary header drain in U#1 near FOPH line.(FE)
7. Close the 3rd extraction to auxiliary line I/V in all units and open the drain after isolation V/V.(FE)
8. During isolation if hammering is observed increase the opening of drains. (FE)
9. Open the drains fully and monitor the auxiliary header temperature.(FE)
10. After the header temperature comes down to room temperature issue PTW for maintenance activity.(FE)
SAFETY:
1. There should
be no steam
leakage
HEALTH:
Ensure proper
lighting
3rd extraction to auxiliary Drain to condenser Drain to arrangement
header atmosphere
3.Normalisation
Procedure
ABNORMALITY TREATMENT
ABNORMALITIES REASON CORRECTIVE ACTION
Leakage from Auxiliary header Condensate deposition Drain Auxiliary header line properly
while charging
4. Cross Glands and gaskets of isolation Inform boiler MMD to resolve the
Reference valves are damaged problem
Line hammering Condensate deposition Drain the line before charging the
steam
Low auxiliary header temperature Auxiliary steam temperature is low Open the auxiliary header drains
5. OH&S, EMS, after charging near U#1 in D/A floor
SAFETY, ENMS &
PRECAUTIONS
Close SCAPH drain isolation valve once required APH outlet temp reaches.
5.5 PRECAUTIONS :
Ensure FD fan is running Before charging steam, to avoid over heating of SCAPH
REVISION PAGE
CHANGE EFFECTED DATE OF CHANGE
NUMBER NUMBERS
00 All pages Revision as per process requirement 23.03.2016