Professional Documents
Culture Documents
Hilti Design Calculations
Hilti Design Calculations
86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 1
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
Specifier's comments:
1 Anchor Design
1.1 Input data
Anchor type and diameter: Threaded rod with nut and washer 5.8 M12
Effective embedment depth: hef = 120.0 mm
Material: 5.8
Evaluation Service Report: -
Issued I Valid: -|-
Proof: Design Method EN 1992-4, CastInPlace
Stand-off installation: eb = 0.0 mm (no stand-off); t = 10.0 mm
Anchor plate
CBFEM
: lx x ly x t = 200.0 mm x 200.0 mm x 10.0 mm;
CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 2
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
3 4
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.002 0.023 0.007 0.021 Tension
2 0.000 0.025 0.008 0.024 x
3 0.013 0.022 0.004 0.022
4 0.000 0.027 0.005 0.027 Compression
Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 3
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s
N
NEd £ NRd,p = Rk,p EN 1992-4, Table7.1
gM,p
NRk,p = k2 · Ah · fck EN 1992-4, Eq. (7.11)
2 2
k2 Ah [mm ] fck [N/mm ]
7.500 141 30.00
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 4
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
124,000 129,600 180.0 360.0 30.00
Group anchor ID
1, 3
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 5
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)
0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
21.918 1.000 21.918 1.250 17.534 0.027
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 6
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · NRk,c EN 1992-4, Eq. (7.39a)
0 A
NRk,c = NRk,c · c,N
0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
'
hef = max ( cmax smax
,
ccr,N scr,N )·h ef EN 1992-4, Eq. (7.9)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
160,000 67,600 180.0 360.0 2.000 30.00
' ' '
hef [mm] ccr,N [mm] scr,N [mm]
86.7 130.0 260.0
Group anchor ID
1-4
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 7
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2
= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 8
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
1.5 Combined tension and shear loads (EN 1992-4, Section 7.2.3)
Steel failure
a a
bN + bV £ 1.0
Concrete failure
a a
bN + bV £ 1.0
1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The designed fasteners should respect the product design conditions and recommendations by the manufacturer and in EN 1992-4, section
F.3, such as welding procedures, installation, max. size of fixing, etc.
• Please ensure that the fastening system is statically indetermined
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 9
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
Hilti Threaded rod with nut and washer threaded rod with nut with 120 mm embedment, M12, Steel galvanized, installation per -
y
100.0 100.0
30.0
3 4
100.0
140.0
x
100.0
1 2
30.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 10
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 11
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
2.3 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.
● Calculation with profiles thinner than 4.0 mm might be outside of EN19931-1 and EN1993-1-8.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 12
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
3 Summary of results
Load combination Max. utilization Status
Anchors Combination 1 1% OK
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
Hilti PROFIS Engineering 3.0.86
www.hilti.bh
Company: Biabani Glass Solutions WLL Page: 13
Address: 24, 1584 Specifier: Mohammad Mazhar Uddin
Phone I Fax: 35959727 | E-Mail: engineer@biabaniglass.com
Design: CIPRIANI- Socialitica- baseplate design calculations Date: 1/7/2023
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
13