You are on page 1of 5

Electronic Devices and Circuits

(EL-1004)
LABORATORY MANUAL
FALL 2023

(LAB # 01)
Familiarization to Proteus and Lab Equipment

Engr. Kashif Ullah Khattak

Student Name: _M.Ishtiaq Azfar


__________________________

Roll No:22i-2194 _____________ Section: ____A_______

Date performed: __________________________

Manual Submission Date: __________________


______________________________________________________________________________________________________________________________________________________

NATIONAL UNIVERSITY OF COMPUTER AND EMERGING SCIENCES, ISLAMABAD

Prepared by: Engr. Naveed Iqbal Version: 2.14


Last Edited by: Engr. Maria Nasir Updated: Fall 2023
Verified by: Dr. Rashad Ramzan
Electronic Devices National University Roll No: __________ L
& Circuits
(EL-1004)
of Computer and Emerging Sciences
Islamabad
a
b
#
01
_________________________________________________________________________________

_______________________________
LAB ENGINEER SIGNATURE & DATE

MARKS AWARDED: /10


LAB: 01 Familiarization to Proteus and Lab Equpiment

TASK NO 1:

Procedure:

EDC LAB NUCES, ISLAMABAD Page 2 of 5


Electronic Devices National University Roll No: __________ L
& Circuits
(EL-1004)
of Computer and Emerging Sciences
Islamabad
a
b
#
01
_________________________________________________________________________________

1. First, I made the simulation of the circuit .


2. In this circuit , I have used four diodes , AC voltage source and an oscilloscope for the
observation of waveforms.
3. After completion of circuit , I changed the amplitude of ac source to 12v and frequency to
50Hz.
4. By this arrangement , I got this kind of waveform .

TASK NO 2:

Procedure:
1. In this circuit, the main motive was to calculate the voltage and current.
2. First , I made the simulation of circuit.
3. In this circuit a dc voltage source , a diode ,dc voltmeter , dc ammeter , 1k-ohm resistor
has been used.
4. The voltmeter is connected in parallel because the voltage is same in parallel circuit and
ammeter is connected in series because the current is same in series circuit.

Vin Simulated Results


(V)
Vd (V) Id (mA) Slope (Id/Vd)

EDC LAB NUCES, ISLAMABAD Page 3 of 5


Electronic Devices National University Roll No: __________ L
& Circuits
(EL-1004)
of Computer and Emerging Sciences
Islamabad
a
b
#
01
_________________________________________________________________________________

0.0 0 0 0
0.2 0.2 0 0
0.4 0.4 0 0
0.6 0.57 0.03 0.052
0.8 0.611 0.19 0.31
1.0 0.63 0.37 0.587
1.2 0.64 0.56 0.875
1.4 0.65 0.75 1.15
1.6 0.63 0.95 1.50
1.8 0.66 1.14 1.72
2.0 0.66 1.34 2.03
3.0 0.68 2.32 3.41
4.0 0.69 3.31 4.79
5.0 0.69 4.31 6.24
6.0 0.70 5.30 7.5
7.0 0.70 6.30 9
8.0 0.71 7.29 10.26
9.0 0.71 8.29 11.6
10.0 0.72 9 12.5

EDC LAB NUCES, ISLAMABAD Page 4 of 5


Electronic Devices National University Roll No: __________ L
& Circuits
(EL-1004)
of Computer and Emerging Sciences
Islamabad
a
b
#
01
_________________________________________________________________________________

EDC LAB NUCES, ISLAMABAD Page 5 of 5