You are on page 1of 32

FOOTING DESIGN CALCULATIONS

Project : 1001
Name
Client : ERIK_HERNANDEZ
Name
Engineer : MRHII
Name
Design : C:\Users\Eagle_roger\OneDrive\Desktop\3_Storey_cantilever\BASEMENT_SUB_STRUCTURE_footing_-
File Footing-1.rcdx
Analysis : C:\Users\Eagle_roger\OneDrive\Desktop\3_Storey_cantilever\BASEMENT_SUB_STRUCTURE_footing_.STD
File
Analysis : 07/03/2024 6:04:43 am
Last
Modified

Definitions:
1. A = Plan area of footing base in 'sqmm'
2. Ast (min) = Area of longitudinal reinforcement as per code in 'sqmm'
3. Ast Prv = Area of tensile reinforcement provided in 'sqmm'
4. Ast Rqd = Area of longitudinal reinforcement from bearing moment and
minimum % steel provided by user and as per code in 'sqmm'
5. Av = Area of shear reinforcement required in 'sqmm/m'
6. AvPrv = Area of shear reinforcement provided in 'sqmm/m'
7. A1 = Bearing area of footing at slope of 1:2 in 'sqmm'
8. A2 = C/s Area of column in 'sqmm'
9. B = Width of footing base in 'mm'
10. Beff = Effective width of footing in 'mm'
11. Boff = Footing offset along B in 'mm'
12. BoffB = Footing offset along B above column in plan in 'mm'
13. BoffT = Footing offset along B below column in planin 'mm'
14. B1 = Width of sloped footing at top in 'mm'
15. ColOff = Column offset in sloped footing in 'mm'
16. Cx = Width of column in 'mm'
17. Cy = Length of Column in 'mm'
18. D = Depth of footing in 'mm'
19. d = Effective Depth of footing in 'mm'
20. Dfd = Depth of founding layer in 'm'
21. Dw = Ground water level in 'm'
22. Ec = Modulus of elasticity of concrete in 'N/sqmm'
23. Es = Modulus of elasticity of steel in 'N/sqmm'
24. Foss = Safety factor against sliding
25. Fosu = Safety factor against uplift
26. Fst = Stress in steel in 'N/sqmm'
27. F'c = Characteristic strength of concrete in 'N/sqmm'
28. Icr = Moment of Inertia of concrete crack section in 'mm4'
29. L = Length of footing base in 'mm'
30. Leff = Effective length of footing in 'mm'
31. Loff = Footing offset along L in 'mm'

07/03/2024 13:14:22 pm 1/32


32. LoffL = Footing offset along L on left side of column in 'mm'
33. LoffR = Footing offset along L on right side of column in 'mm'
34. L1 = Length of sloped footing at top in 'mm'
35. Mcr = Cracking Moment
36. Mx = Bending Moment along column D in 'kNm'
37. Mex = Eccentricity moment along column D
38. Mxx = Total Bending Moment along column D (Mx + Mex)
39. My = Bending Moment along column B in 'kNm'
40. Mey = Eccentricity moment along column B
41. Myy = Total Bending Moment along column B (My + Mey)
42. Muy = Factored moment along column B in 'kNm'
43. Mux = Factored moment along column D in 'kNm'
44. Netdown = Net downward load in 'kN'
45. OB = Maximum permissible offset On bottom side Of column
46. OL = Maximum permissible offset On left side Of column
47. Or = Maximum permissible offset On right side Of column
48. OT = Maximum permissible offset On top side Of column
49. P = Axial load For footing sizing In 'kN'
50. Pcr(axial) = Design pressure at the critical section in 'kN/sqm'
51. P1 = Soil pressure at corner 1 In 'kN/sqm'
52. P2 = Soil pressure at corner 2 'kN/sqm'
53. P3 = Soil pressure at corner 3 'kN/sqm'
54. P4 = Soil pressure at corner 4 'kN/sqm'
55. q = Surcharge Load In 'kN/sqm'
56. sp = Spacing Between bars at outer most layer In 'mm'
57. SPu = Upward Soil Pressure In 'kN/sqm'
58. SPuL = Upward Soil Pressure from left
59. SPuR = Upward Soil Pressure from right
60. SPuB = Upward Soil Pressure from bottom
61. SPuT = Upward Soil Pressure from top
62. Temp1 = Peak Hydration temperature In Degree
63. Temp2 = Seasonal Temperature Variations In Degree
64. Vs Capacity = Shear strength capacity Of provided shear reinforcement 'kN'
65. Vs = Nominal shear strength provided by shear reinforcement, in
'kN'
66. Vc = Nominal shear strength provided by concrete in 'kN'
67. Vu = Design shear force in 'kN'
68. Vus = Strength of shear reinforcement in 'kN'
69. Vx = Shear along major axis in 'kN'
70. Vy = Shear along minor axis in 'kN'
71. Waterpr = Upward water pressure in 'kN/sqm'
72. Waterup = Upward force due to water in 'kN/sqm'
73. WFoot = Add. Wt. due to difference in concrete and soil density in 'kN'
74. WFootc = Weight of footing and column with concrete density in 'kN'
75. WSoil = Weight of soil covering footing area in 'kN'
76. y = Neutral axis depth.
77. Zx = Section modulus of footing base along L in 'mm4'

07/03/2024 13:14:22 pm 2/32


78. Zy = Section modulus of footing base along B in 'mm4'
79. Φ = Strength reduction factor in shear
80. Φ1 = Strength reduction factor in concrete bearing
81. Φ1Pnb = Bearing strength of column in 'kN'

Code References:
NSCP C101 - 2015
Sr.No. Item Clause / Table
1. Ptmax : 407.3.3.1, 408.3.3.1, 409.3.3.1
2. Ptmin : 407.6.1.1 & 408.6.1.1/407.7.2.3
3. Vc : 422.6.5
4. Av : 422.5.10.5 & 422.6.7
5. Max Stirrup Spacing : 409.7.6.2 & 410.7.6.5
6. Vs : 422.5.1.2
7. fs,perm : 424.3.2.1
8. fc,perm : 422.2.2.4.1
9. Wcr : Eq 1-2 ( ACI 224R-01)

Design Code : NSCP C101 - 2015


Footing No : FC6
Column No : C6 ( 5500mm X 300mm)
MESHED
Analysis No :
SURFACE 3-2

Concrete Grade : C28


Steel Grade : Fy414
Clear Cover : 75 mm
Dfd : 4m
Dw : 5.3 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 30 %
Permissible SBC Increase for Wind = 30 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure
Surcharge Load = 2.19 kN/sqm

Footing Type : Pad


Footing Size (L x B x D) : 11350mm X 6150mm X 3825mm
Surcharge Load = 152.87 kN

07/03/2024 13:14:22 pm 3/32


Without considering Effect of Water Table
Footing Self Wt., F1 = 6674.86 kN
Soil Weight, S1 = 214.68 kN
Total Weight, W1 = F1 + S1 + Surcharge Load
= 7042.41 kN
Offset Along L (Loff) = 2925 mm
Offset Along B (Boff) = 2925 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 115
Critical Load Combination = [15] : 0.9 (LOAD 9: DL) +(LOAD 4: EQ-X-E)
Pcomb = 3000.71 kN
P = Pcomb + W1 x 0.9
P = 9338.88 kN
Mx = -1724.19 kNm
My = 105.1 kNm
P/A = 133.79 kN/sqm
Mx/Zx = -13.06 kN/sqm
My/Zy = 1.47 kN/sqm
Maximum Soil Pressure = 148.32 kN/sqm
Allowable Soil Pressure = 1.3x200 kN/sqm
= 260 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 222
Critical Load Combination = [41] : 0.42 (LOAD 9: DL) +
(LOAD 1: EQ+X+E)
Pcomb = -922.38 kN
P = Pcomb + W1 x 0.42
P = 2035.44 kN
Mx = -889.75 kNm
My = -58.81 kNm
P/A = 29.16 kN/sqm
Mx/Zx = -6.74 kN/sqm
My/Zy = -0.82 kN/sqm
Minimum Soil Pressure = 21.6 kN/sqm
> 0
Check For Sliding:
Critical Analysis Load Combination = 223
Critical Load Combination = [42] : 0.42 (LOAD 9: DL) +(LOAD 2: EQ+X-E)
Pcomb = -755.25 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 26.01 kN
shear Vy = 711.07 kN
Resultant sliding force = 711.54 kN
Downward force = Pcomb + (F1 + S1) x 0.42

07/03/2024 13:14:22 pm 4/32


= 2138.36 kN
Upward water pressure = 0 kN
Net downward force = 2138.36 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 855.34 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.2
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 228
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 7: EQ-Z+E)
Factor of safety = 1.50
Pcomb = 434.74 kN
Moment Mx = 2983.77 kNm
P = Pcomb + (F1 + S1) x 0.42
= 3328.35 kN
Stabilizing Moment for P = 18888.4 kNm
DeStabilizing Moment = 2983.77 kNm
Overturning Factor of safety = 6.33
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 222
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 1: EQ+X+E)
Factor of safety = 1.50
Pcomb = -922.38 kN
Moment My = 58.81 kNm
P = Pcomb + (F1 + S1) x 0.42
= 1971.23 kN
Stabilizing Moment for P = 6061.54 kNm
DeStabilizing Moment = 58.81 kNm
Overturning Factor of safety = 103.07
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 209
Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 4232.78 kN
Mux = -3284.26 kNm
Muy = 132.13 kNm
P/A = 60.64 kN/sqm
Mx/Zx = -24.87 kN/sqm

07/03/2024 13:14:22 pm 5/32


My/Zy = 1.85 kN/sqm

Deff = 3742 mm
Beff = 6150 mm
SPu = 85.51 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 2249.7 kNm
Ast Rqd = 47047.5 sqmm
Ast (min) = 47047.5 sqmm
Ast Prv (Distributed Across Total Width) = 60 - #32 @ 105
= 48255 sqmm

Top Steel Along L:


Deff = 3742 mm
Beff = 6150 mm
S/W + Soil + Surcharge Load = 100.96 kN/sqm
Mu = 3187.49 kNm
Pt = 0.2 %
Maximum of following
Ast Rqd (BM) = 47047.5 sqmm
Ast = Min Pt for Top Reinforcement X D X B
= 0.13% X 3825 X 6150
= 30580.88 sqmm
Max Ast = 47047.5 sqmm
Ast Prv (Distributed Across Total Width) = 60 - #32 @ 105 c/c
= 48255 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 209
Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 4232.78 kN
Mux = -3284.26 kNm
Muy = 132.13 kNm
P/A = 60.64 kN/sqm
Mx/Zx = -24.87 kN/sqm
My/Zy = 1.85 kN/sqm

Deff = 3726 mm
Leff = 11350 mm
SPu = 62.49 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 3033.9 kNm
Ast Rqd = 86827.5 sqmm
Ast (min) = 86827.5 sqmm
Ast Prv (Distributed Across Total Length) = 110 - #32 @ 105
= 88467.5 sqmm

07/03/2024 13:14:22 pm 6/32


Top Steel Along B:
Deff = 3726 mm
Beff = 11350 mm
S/W + Soil + Surcharge Load = 100.96 kN/sqm
Mu = 5882.61 kNm
Pt = 0.21 %
Maximum of following
Ast Rqd (BM) = 86827.5 sqmm
Ast = Min Pt for Top Reinforcement X D X L
= 0.13% X 3825 X 11350
= 56437.88 sqmm
Max Ast = 86828 sqmm
Ast Prv (Distributed Across Total Length) = 110 - #32 @ 105 c/c
= 88467.5 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 3742 mm
All Load Combination having Axial Tension Force.
Thus, One way Shear is not applicable for Compressive Force.
One Way Shear Along L (Tension Case):
At face of column
Soil + Surcharge Load,q = 100.96 kN/sqm
Deff = 3742 mm
Beff = 6150 mm
Vu = q x Loff X B X 1.2
= 2179.48 kN
φVc = 15102.84 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 3726 mm
All Load Combination having Axial Tension Force.
Thus, One way Shear is not applicable for Compressive Force.

One Way Shear Along B (Tension Case):


At face of Column
Soil + Surcharge Load,q = 100.96 kN/sqm
Deff = 3726 mm
Leff = 11350 mm
Vu = q x Boff X L X 1.2
= 4022.29 kN
φVc = 27758.27 kN
Vu < φVc

07/03/2024 13:14:22 pm 7/32


Design For Punching Shear:
Critical Section @ d/2 from Column Face
= 1867 mm

Critical Analysis Load Combination = 209


Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 4232.78 kN
Mux = -3284.26 kNm
Muy = 132.13 kNm
P/A = 60.64 kN/sqm
Mx/Zx = -24.87 kN/sqm
My/Zy = 1.85 kN/sqm

Deff = 3734 mm
Leff = 9234 mm
Beff = 4034 mm
Punching Perimeter = 26536 mm
Punching Area = 99085424 sqmm
SPu = Average Pressure
= 60.64 kN/sqm
Vu = { SPu [ (L x B)- (Leff x Beff)]}
= 1973.97 kN
φVn = 195136.35 kN
φVc = 73584.14 kN
No Shear
Vu < φVc Reinforcement
Required

Design For Punching Shear (Tension Case):


At face of column
Pu = -161.12 kN
Deff = 3734 mm
Leff = 5500 mm
Beff = 300 mm
Punching Perimeter = 11600 mm
Punching Area = 43314400 sqmm
Vu = 161.12 kN
φVc = 85302.29 kN
Vu < φVc
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 3825 X 500
= 956.25 sqmm

Asfr Prv = 13-#10


= 1021.02 sqmm

07/03/2024 13:14:22 pm 8/32


Load Transfer Check For Load Transfer From Column To Footing
Critical Analysis Load Combination = 209
Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5
(LOAD 10: LL) +(LOAD 4:
EQ-X-E)
Pu = 4232.78 kN
A2 = 1.65 sqm
A1 = 324.48 sqm
Base Area = 69.8 sqm
A1 > Base Area
Thus, A1 = 69.8
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 6.5041
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column
Area
= 50285.24 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC7
Column No : C7 ( 5500mm X 300mm)
MESHED
Analysis No :
SURFACE 5-2

Concrete Grade : C28


Steel Grade : Fy414
Clear Cover : 75 mm
Dfd : 4m
Dw : 5.3 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 30 %
Permissible SBC Increase for Wind = 30 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure
Surcharge Load = 2.19 kN/sqm

Footing Type : Pad

07/03/2024 13:14:22 pm 9/32


Footing Size (L x B x D) : 12950mm X 7750mm X 3800mm
Surcharge Load = 219.79 kN
Without considering Effect of Water Table
Footing Self Wt., F1 = 9534.44 kN
Soil Weight, S1 = 355.36 kN
Total Weight, W1 = F1 + S1 + Surcharge Load
= 10109.6 kN
Offset Along L (Loff) = 3725 mm
Offset Along B (Boff) = 3725 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 112
Critical Load Combination = [12] : 0.9 (LOAD 9: DL) +(LOAD 1: EQ+X+E)
Pcomb = 1669.8 kN
P = Pcomb + W1 x 0.9
P = 10768.44 kN
Mx = -1834.29 kNm
My = -44.3 kNm
P/A = 107.3 kN/sqm
Mx/Zx = -8.47 kN/sqm
My/Zy = -0.34 kN/sqm
Maximum Soil Pressure = 116.11 kN/sqm
Allowable Soil Pressure = 1.3x200 kN/sqm
= 260 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 225
Critical Load Combination = [44] : 0.42 (LOAD 9: DL) +
(LOAD 4: EQ-X-E)
Pcomb = -1418.27 kN
P = Pcomb + W1 x 0.42
P = 2827.77 kN
Mx = -633.7 kNm
My = 87.84 kNm
P/A = 28.18 kN/sqm
Mx/Zx = -2.93 kN/sqm
My/Zy = 0.68 kN/sqm
Minimum Soil Pressure = 24.57 kN/sqm
> 0
Check For Sliding:
Critical Analysis Load Combination = 228
Critical Load Combination = [47] : 0.42 (LOAD 9: DL) +(LOAD 7: EQ-Z+E)
Pcomb = 283.45 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 2.04 kN
shear Vy = 1477.79 kN

07/03/2024 13:14:22 pm 10/32


Resultant sliding force = 1477.79 kN
Downward force = Pcomb + (F1 + S1) x 0.42
= 4437.16 kN
Upward water pressure = 0 kN
Net downward force = 4437.16 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 1774.87 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.2
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 229
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 8: EQ-Z-E)
Factor of safety = 1.50
Pcomb = 159.23 kN
Moment Mx = 2933.63 kNm
P = Pcomb + (F1 + S1) x 0.42
= 4312.95 kN
Stabilizing Moment for P = 27926.35 kNm
DeStabilizing Moment = 2933.63 kNm
Overturning Factor of safety = 9.52
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 225
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 4: EQ-X-E)
Factor of safety = 1.50
Pcomb = -1418.27 kN
Moment My = 87.84 kNm
P = Pcomb + (F1 + S1) x 0.42
= 2735.45 kN
Stabilizing Moment for P = 10599.88 kNm
DeStabilizing Moment = 87.84 kNm
Overturning Factor of safety = 120.68
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 206
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 1: EQ+X+E)
Pu = 1850.49 kN
Mux = -3306.64 kNm
Muy = -18.94 kNm

07/03/2024 13:14:22 pm 11/32


P/A = 18.44 kN/sqm
Mx/Zx = -15.26 kN/sqm
My/Zy = -0.15 kN/sqm

Deff = 3717 mm
Beff = 7750 mm
SPu = 33.7 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1812.15 kNm
Ast Rqd = 58900 sqmm
Ast (min) = 58900 sqmm
Ast Prv (Distributed Across Total Width) = 75 - #32 @ 105
= 60318.75 sqmm

Top Steel Along L:


Deff = 3717 mm
Beff = 7750 mm
S/W + Soil + Surcharge Load = 100.79 kN/sqm
Mu = 6503.14 kNm
Pt = 0.2 %
Maximum of following
Ast Rqd (BM) = 58900 sqmm
Ast = Min Pt for Top Reinforcement X D X B
= 0.13% X 3800 X 7750
= 38285 sqmm
Max Ast = 58900 sqmm
Ast Prv (Distributed Across Total Width) = 75 - #32 @ 105 c/c
= 60318.75 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 206
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 1: EQ+X+E)
Pu = 1850.49 kN
Mux = -3306.64 kNm
Muy = -18.94 kNm
P/A = 18.44 kN/sqm
Mx/Zx = -15.26 kN/sqm
My/Zy = -0.15 kN/sqm

Deff = 3701 mm
Leff = 12950 mm
SPu = 18.58 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 1669.69 kNm
Ast Rqd = 98420 sqmm
Ast (min) = 98420 sqmm

07/03/2024 13:14:22 pm 12/32


Ast Prv (Distributed Across Total Length) = 125 - #32 @ 105
= 100531.25 sqmm

Top Steel Along B:


Deff = 3701 mm
Beff = 12950 mm
S/W + Soil + Surcharge Load = 100.79 kN/sqm
Mu = 10866.53 kNm
Pt = 0.21 %
Maximum of following
Ast Rqd (BM) = 98420 sqmm
Ast = Min Pt for Top Reinforcement X D X L
= 0.13% X 3800 X 12950
= 63973 sqmm
Max Ast = 98420 sqmm
Ast Prv (Distributed Across Total Length) = 125 - #32 @ 105 c/c
= 100531.25 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 3717 mm
Critical Analysis Load Combination = 206
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 1: EQ+X+E)
Pu = 1850.49 kN
Mux = -3306.64 kNm
Muy = -18.94 kNm
P/A = 18.44 kN/sqm
Mx/Zx = -15.26 kN/sqm
My/Zy = -0.15 kN/sqm

Deff = 3717 mm
Beff = 7750 mm
SPu = 33.7 kN/sqm
Vu = SPu X (Loff - d) X B
= 2.09 kN
One Way Shear Along L (Tension Case):
At face of column
Soil + Surcharge Load,q = 100.79 kN/sqm
Deff = 3717 mm
Beff = 7750 mm
Vu = q x Loff X B X 1.2
= 3491.62 kN
φVc = 32904.15 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

07/03/2024 13:14:22 pm 13/32


= 3701 mm
Critical Analysis Load Combination = 206
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5
(LOAD 10: LL) +(LOAD 1:
EQ+X+E)
Pu = 1850.49 kN
Mux = -3306.64 kNm
Muy = -18.94 kNm
P/A = 18.44 kN/sqm
Mx/Zx = -15.26 kN/sqm
My/Zy = -0.15 kN/sqm

Deff = 3701 mm
Leff = 12950 mm
SPu = 18.58 kN/sqm
Vu = SPu X (Boff - d) X L
= 5.78 kN

One Way Shear Along B (Tension Case):


At face of Column
Soil + Surcharge Load,q = 100.79 kN/sqm
Deff = 3701 mm
Leff = 12950 mm
Vu = q x Boff X L X 1.2
= 5834.38 kN
φVc = 54745.1 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 1854 mm

Critical Analysis Load Combination = 206


Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 1: EQ+X+E)
Pu = 1850.49 kN
Mux = -3306.64 kNm
Muy = -18.94 kNm
P/A = 18.44 kN/sqm
Mx/Zx = -15.26 kN/sqm
My/Zy = -0.15 kN/sqm

Deff = 3709 mm
Leff = 9209 mm
Beff = 4009 mm
Punching Perimeter = 26436 mm
Punching Area = 98051124 sqmm

07/03/2024 13:14:22 pm 14/32


SPu = Average Pressure
= 18.44 kN/sqm
Vu = { SPu [ (L x B)- (Leff x Beff)]}
= 1169.78 kN
φVn = 193099.42 kN
φVc = 72816.04 kN
No Shear
Vu < φVc Reinforcement
Required

Design For Punching Shear (Tension Case):


At face of column
Pu = -1321.29 kN
Deff = 3709 mm
Leff = 5500 mm
Beff = 300 mm
Punching Perimeter = 11600 mm
Punching Area = 43024400 sqmm
Vu = 1321.29 kN
φVc = 84731.17 kN
Vu < φVc
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 3800 X 500
= 950 sqmm

Asfr Prv = 13-#10


= 1021.02 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 206
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5
(LOAD 10: LL) +(LOAD 1:
EQ+X+E)
Pu = 1850.49 kN
A2 = 1.65 sqm
A1 = 320.85 sqm
Base Area = 100.36 sqm
A1 > Base Area
Thus, A1 = 100.36
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 7.799
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column
Area
= 50285.24 kN

07/03/2024 13:14:22 pm 15/32


Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC8
Column No : C8 ( 2000mm X 300mm)
MESHED
Analysis No :
SURFACE 4-2

Concrete Grade : C28


Steel Grade : Fy414
Clear Cover : 75 mm
Dfd : 4m
Dw : 5.3 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 30 %
Permissible SBC Increase for Wind = 30 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure
Surcharge Load = 2.19 kN/sqm

Footing Type : Pad


Footing Size (L x B x D) : 6550mm X 4850mm X 3825mm
Surcharge Load = 69.57 kN
Without considering Effect of Water Table
Footing Self Wt., F1 = 3037.77 kN
Soil Weight, S1 = 98.18 kN
Total Weight, W1 = F1 + S1 + Surcharge Load
= 3205.52 kN
Offset Along L (Loff) = 2275 mm
Offset Along B (Boff) = 2275 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 117
Critical Load Combination = [17] : 0.9 (LOAD 9: DL) +(LOAD 6: EQ+Z-E)
Pcomb = 295.68 kN
P = Pcomb + W1 x 0.9
P = 3180.65 kN
Mx = -363.01 kNm
My = 7.38 kNm
P/A = 100.12 kN/sqm

07/03/2024 13:14:22 pm 16/32


Mx/Zx = -10.47 kN/sqm
My/Zy = 0.29 kN/sqm
Maximum Soil Pressure = 110.88 kN/sqm
Allowable Soil Pressure = 1.3x200 kN/sqm
= 260 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 228
Critical Load Combination = [47] : 0.42 (LOAD 9: DL) +
(LOAD 7: EQ-Z+E)
Pcomb = -635.29 kN
P = Pcomb + W1 x 0.42
P = 711.02 kN
Mx = 287.99 kNm
My = -18.4 kNm
P/A = 22.38 kN/sqm
Mx/Zx = 8.3 kN/sqm
My/Zy = -0.72 kN/sqm
Minimum Soil Pressure = 13.36 kN/sqm
> 0
Check For Sliding:
Critical Analysis Load Combination = 228
Critical Load Combination = [47] : 0.42 (LOAD 9: DL) +(LOAD 7: EQ-Z+E)
Pcomb = -635.29 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 14.14 kN
shear Vy = 226.44 kN
Resultant sliding force = 226.88 kN
Downward force = Pcomb + (F1 + S1) x 0.42
= 681.8 kN
Upward water pressure = 0 kN
Net downward force = 681.8 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 272.72 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.2
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 228
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 7: EQ-Z+E)
Factor of safety = 1.50
Pcomb = -635.29 kN
Moment Mx = 287.99 kNm

07/03/2024 13:14:22 pm 17/32


P = Pcomb + (F1 + S1) x 0.42
= 681.8 kN
Stabilizing Moment for P = 2232.91 kNm
DeStabilizing Moment = 287.99 kNm
Overturning Factor of safety = 7.75
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 229
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 8: EQ-Z-E)
Factor of safety = 1.50
Pcomb = -648.51 kN
Moment My = 18.81 kNm
P = Pcomb + (F1 + S1) x 0.42
= 668.58 kN
Stabilizing Moment for P = 1621.31 kNm
DeStabilizing Moment = 18.81 kNm
Overturning Factor of safety = 86.2
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 108
Critical Load Combination = [56] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 6: EQ+Z-E)
Pu = 218.01 kN
Mux = -374.84 kNm
Muy = 4.81 kNm
P/A = 6.86 kN/sqm
Mx/Zx = -10.81 kN/sqm
My/Zy = 0.19 kN/sqm

Deff = 3742 mm
Beff = 4850 mm
SPu = 17.67 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 221.79 kNm
Ast Rqd = 37102.5 sqmm
Ast (min) = 37102.5 sqmm
Ast Prv (Distributed Across Total Width) = 48 - #32 @ 105
= 38604 sqmm

Top Steel Along L:


Deff = 3742 mm
Beff = 4850 mm
S/W + Soil + Surcharge Load = 100.96 kN/sqm
Mu = 1520.64 kNm
Pt = 0.2 %

07/03/2024 13:14:22 pm 18/32


Maximum of following
Ast Rqd (BM) = 37102.5 sqmm
Ast = Min Pt for Top Reinforcement X D X B
= 0.13% X 3825 X 4850
= 24116.62 sqmm
Max Ast = 37102.5 sqmm
Ast Prv (Distributed Across Total Width) = 48 - #32 @ 105 c/c
= 38604 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 116
Critical Load Combination = [64] : 0.9 (LOAD 9: DL) +(LOAD 5: EQ+Z+E)
Pu = 308.91 kN
Mux = -185.7 kNm
Muy = 7.79 kNm
P/A = 9.72 kN/sqm
Mx/Zx = -5.35 kN/sqm
My/Zy = 0.3 kN/sqm

Deff = 3726 mm
Leff = 6550 mm
SPu = 10.03 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 169.96 kNm
Ast Rqd = 50107.5 sqmm
Ast (min) = 50107.5 sqmm
Ast Prv (Distributed Across Total Length) = 64 - #32 @ 105
= 51472 sqmm

Top Steel Along B:


Deff = 3726 mm
Beff = 6550 mm
S/W + Soil + Surcharge Load = 100.96 kN/sqm
Mu = 2053.65 kNm
Pt = 0.21 %
Maximum of following
Ast Rqd (BM) = 50107.5 sqmm
Ast = Min Pt for Top Reinforcement X D X L
= 0.13% X 3825 X 6550
= 32569.88 sqmm
Max Ast = 50108 sqmm
Ast Prv (Distributed Across Total Length) = 64 - #32 @ 105 c/c
= 51472 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 3742 mm

07/03/2024 13:14:22 pm 19/32


All Load Combination having Axial Tension Force.
Thus, One way Shear is not applicable for Compressive Force.
One Way Shear Along L (Tension Case):
At face of column
Soil + Surcharge Load,q = 100.96 kN/sqm
Deff = 3742 mm
Beff = 4850 mm
Vu = q x Loff X B X 1.2
= 1336.83 kN
φVc = 11910.37 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 3726 mm
All Load Combination having Axial Tension Force.
Thus, One way Shear is not applicable for Compressive Force.

One Way Shear Along B (Tension Case):


At face of Column
Soil + Surcharge Load,q = 100.96 kN/sqm
Deff = 3726 mm
Leff = 6550 mm
Vu = q x Boff X L X 1.2
= 1805.41 kN
φVc = 16019.09 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 1867 mm

Critical Analysis Load Combination = 116


Critical Load Combination = [64] : 0.9 (LOAD 9: DL) +(LOAD 5: EQ+Z+E)
Pu = 308.91 kN
Mux = -185.7 kNm
Muy = 7.79 kNm
P/A = 9.72 kN/sqm
Mx/Zx = -5.35 kN/sqm
My/Zy = 0.3 kN/sqm

Deff = 3734 mm
Leff = 5734 mm
Beff = 4034 mm
Punching Perimeter = 19536 mm
Punching Area = 72947424 sqmm

07/03/2024 13:14:22 pm 20/32


SPu = Average Pressure
= 9.72 kN/sqm
Vu = { SPu [ (L x B)- (Leff x Beff)]}
= 83.98 kN
φVn = 143660.83 kN
φVc = 63498.09 kN
No Shear
Vu < φVc Reinforcement
Required

Design For Punching Shear (Tension Case):


At face of column
Pu = -973.18 kN
Deff = 3734 mm
Leff = 2000 mm
Beff = 300 mm
Punching Perimeter = 4600 mm
Punching Area = 17176400 sqmm
Vu = 973.18 kN
φVc = 33826.77 kN
Vu < φVc
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 3825 X 500
= 956.25 sqmm

Asfr Prv = 13-#10


= 1021.02 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 116
Critical Load Combination = [64] : 0.9 (LOAD 9: DL) +
(LOAD 5: EQ+Z+E)
Pu = 308.91 kN
A2 = 0.6 sqm
A1 = 269.88 sqm
Base Area = 31.77 sqm
A1 > Base Area
Thus, A1 = 31.77
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 7.2767
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column
Area
= 18285.54 kN
Φ1Pnb > Pu, Hence Safe.

07/03/2024 13:14:22 pm 21/32


Design Code : NSCP C101 - 2015
Footing No : FC9
Column No : C9 ( 2000mm X 300mm)
MESHED
Analysis No :
SURFACE 6-2

Concrete Grade : C28


Steel Grade : Fy414
Clear Cover : 75 mm
Dfd : 4m
Dw : 5.3 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 30 %
Permissible SBC Increase for Wind = 30 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure
Surcharge Load = 2.19 kN/sqm

Footing Type : Pad


Footing Size (L x B x D) : 7950mm X 6250mm X 3875mm
Surcharge Load = 108.82 kN
Without considering Effect of Water Table
Footing Self Wt., F1 = 4813.48 kN
Soil Weight, S1 = 110.45 kN
Total Weight, W1 = F1 + S1 + Surcharge Load
= 5032.74 kN
Offset Along L (Loff) = 2975 mm
Offset Along B (Boff) = 2975 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 114
Critical Load Combination = [14] : 0.9 (LOAD 9: DL) +(LOAD 3: EQ-X+E)
Pcomb = 931.46 kN
P = Pcomb + W1 x 0.9
P = 5460.92 kN
Mx = -1908.5 kNm
My = 4.25 kNm
P/A = 109.91 kN/sqm
Mx/Zx = -28.99 kN/sqm

07/03/2024 13:14:22 pm 22/32


My/Zy = 0.08 kN/sqm
Maximum Soil Pressure = 138.98 kN/sqm
Allowable Soil Pressure = 1.3x200 kN/sqm
= 260 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load Combination = 224
Critical Load Combination = [43] : 0.42 (LOAD 9: DL) +
(LOAD 3: EQ-X+E)
Pcomb = 481.39 kN
P = Pcomb + W1 x 0.42
P = 2595.14 kN
Mx = -1537.93 kNm
My = 1.56 kNm
P/A = 52.23 kN/sqm
Mx/Zx = -23.36 kN/sqm
My/Zy = 0.03 kN/sqm
Minimum Soil Pressure = 28.84 kN/sqm
> 0
Check For Sliding:
Critical Analysis Load Combination = 224
Critical Load Combination = [43] : 0.42 (LOAD 9: DL) +(LOAD 3: EQ-X+E)
Pcomb = 481.39 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 0.52 kN
shear Vy = 848.88 kN
Resultant sliding force = 848.88 kN
Downward force = Pcomb + (F1 + S1) x 0.42
= 2549.44 kN
Upward water pressure = 0 kN
Net downward force = 2549.44 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 1019.78 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 1.2
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 224
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 3: EQ-X+E)
Factor of safety = 1.50
Pcomb = 481.39 kN
Moment Mx = 1537.93 kNm
P = Pcomb + (F1 + S1) x 0.42

07/03/2024 13:14:22 pm 23/32


= 2549.44 kN
Stabilizing Moment for P = 10134.02 kNm
DeStabilizing Moment = 1537.93 kNm
Overturning Factor of safety = 6.59
Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 229
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 8: EQ-Z-E)
Factor of safety = 1.50
Pcomb = 412.98 kN
Moment My = 11.24 kNm
P = Pcomb + (F1 + S1) x 0.42
= 2481.03 kN
Stabilizing Moment for P = 7753.21 kNm
DeStabilizing Moment = 11.24 kNm
Overturning Factor of safety = 690
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 208
Critical Load Combination = [75] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 3: EQ-X+E)
Pu = 1697.09 kN
Mux = -2501.56 kNm
Muy = 8.64 kNm
P/A = 34.16 kN/sqm
Mx/Zx = -38 kN/sqm
My/Zy = 0.17 kN/sqm

Deff = 3792 mm
Beff = 6250 mm
SPu = 72.15 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1995.6 kNm
Ast Rqd = 48437.5 sqmm
Ast (min) = 48437.5 sqmm
Ast Prv (Distributed Across Total Width) = 61 - #32 @ 105
= 49059.25 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 41 - #32 @ 160 c/c
= 32974.25 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 208
Critical Load Combination = [75] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +

07/03/2024 13:14:22 pm 24/32


(LOAD 3: EQ-X+E)
Pu = 1697.09 kN
Mux = -2501.56 kNm
Muy = 8.64 kNm
P/A = 34.16 kN/sqm
Mx/Zx = -38 kN/sqm
My/Zy = 0.17 kN/sqm

Deff = 3776 mm
Leff = 7950 mm
SPu = 34.32 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 1207.5 kNm
Ast Rqd = 61612.5 sqmm
Ast (min) = 61612.5 sqmm
Ast Prv (Distributed Across Total Length) = 77 - #32 @ 105
= 61927.25 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total Length) = 50 - #32 @ 165 c/c
= 40212.5 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 3792 mm
All Load Combination having Axial Tension Force.
Thus, One way Shear is not applicable for Compressive Force.

One Way Shear Along B:


Critical Section @ d from Column Face

= 3776 mm
All Load Combination having Axial Tension Force.
Thus, One way Shear is not applicable for Compressive Force.

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 1892 mm

Critical Analysis Load Combination = 208


Critical Load Combination = [75] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 3: EQ-X+E)
Pu = 1697.09 kN
Mux = -2501.56 kNm
Muy = 8.64 kNm
P/A = 34.16 kN/sqm
Mx/Zx = -38 kN/sqm
My/Zy = 0.17 kN/sqm

07/03/2024 13:14:22 pm 25/32


Deff = 3784 mm
Leff = 5784 mm
Beff = 4084 mm
Punching Perimeter = 19736 mm
Punching Area = 74681024 sqmm
SPu = Average Pressure
= 34.16 kN/sqm
Vu = { SPu [ (L x B)- (Leff x Beff)]}
= 890.28 kN
φVn = 147074.93 kN
φVc = 65007.12 kN
No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 3875 X 500
= 968.75 sqmm

Asfr Prv = 13-#10


= 1021.02 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 208
Critical Load Combination = [75] : 1.68 (LOAD 9: DL) +0.5
(LOAD 10: LL) +(LOAD 3:
EQ-X+E)
Pu = 1697.09 kN
A2 = 0.6 sqm
A1 = 276.5 sqm
Base Area = 49.69 sqm
A1 > Base Area
Thus, A1 = 49.69
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 9.1004
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column
Area
= 18285.54 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC10
Column No : C10 ( 850mm X 850mm)

07/03/2024 13:14:22 pm 26/32


Analysis No : 27

Concrete Grade : C28


Steel Grade : Fy414
Clear Cover : 75 mm
Dfd : 4m
Dw : 5.3 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 30 %
Permissible SBC Increase for Wind = 30 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure
Surcharge Load = 2.19 kN/sqm

Footing Type : Pad


Footing Size (L x B x D) : 3500mm X 3500mm X 500mm
Surcharge Load = 26.83 kN
Without considering Effect of Water Table
Footing Self Wt., F1 = 153.12 kN
Soil Weight, S1 = 726.23 kN
Total Weight, W1 = F1 + S1 + Surcharge Load
= 906.18 kN
Offset Along L (Loff) = 1325 mm
Offset Along B (Boff) = 1325 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 114
Critical Load Combination = [14] : 0.9 (LOAD 9: DL) +(LOAD 3: EQ-X+E)
Pcomb = 1663.96 kN
P = Pcomb + W1 x 0.9
P = 2479.52 kN
Mx = 330.86 kNm
My = 19.5 kNm
P/A = 202.41 kN/sqm
Mx/Zx = 46.3 kN/sqm
My/Zy = 2.73 kN/sqm
Maximum Soil Pressure = 251.44 kN/sqm
Allowable Soil Pressure = 1.3x200 kN/sqm
= 260 kN/sqm

Check For Minimum Soil Pressure:

07/03/2024 13:14:22 pm 27/32


Critical Analysis Load Combination = 223
Critical Load Combination = [42] : 0.42 (LOAD 9: DL) +
(LOAD 2: EQ+X-E)
Pcomb = 279.6 kN
P = Pcomb + W1 x 0.42
P = 660.2 kN
Mx = -100.25 kNm
My = -35.38 kNm
P/A = 53.89 kN/sqm
Mx/Zx = -14.03 kN/sqm
My/Zy = -4.95 kN/sqm
Minimum Soil Pressure = 34.91 kN/sqm
> 0
Check For Sliding:
Critical Analysis Load Combination = 224
Critical Load Combination = [43] : 0.42 (LOAD 9: DL) +(LOAD 3: EQ-X+E)
Pcomb = 957.21 kN
Coefficient Of Friction = 0.4
Factor of safety = 1.2
Shear Vx = 6.86 kN
shear Vy = 49.66 kN
Resultant sliding force = 50.13 kN
Downward force = Pcomb + (F1 + S1) x 0.42
= 1326.54 kN
Upward water pressure = 0 kN
Net downward force = 1326.54 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 530.62 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 10.58
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 224
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 3: EQ-X+E)
Factor of safety = 1.50
Pcomb = 957.21 kN
Moment Mx = 247 kNm
P = Pcomb + (F1 + S1) x 0.42
= 1326.54 kN
Stabilizing Moment for P = 2321.44 kNm
DeStabilizing Moment = 247 kNm
Overturning Factor of safety = 9.4
Safe in Overturning > 1.50

07/03/2024 13:14:22 pm 28/32


Along Length:
Critical Analysis Load Combination = 226
Critical Load Combination = 0.42 (LOAD 9: DL) +(LOAD 5: EQ+Z+E)
Factor of safety = 1.50
Pcomb = 360.57 kN
Moment My = 55.49 kNm
P = Pcomb + (F1 + S1) x 0.42
= 729.9 kN
Stabilizing Moment for P = 1277.32 kNm
DeStabilizing Moment = 55.49 kNm
Overturning Factor of safety = 23.02
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 209
Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 2830.49 kN
Mux = 465.18 kNm
Muy = -0.58 kNm
P/A = 231.06 kN/sqm
Mx/Zx = 65.1 kN/sqm
My/Zy = -0.08 kN/sqm

Deff = 417 mm
Beff = 3500 mm
SPu = 296.16 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 909.9 kNm
Ast Rqd = 6079.82 sqmm
Ast (min) = 3500 sqmm
Ast Prv (Distributed Across Total Width) = 31 - #16 @ 120
= 6232.86 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 29 - #10 @ 125 c/c
= 2277.66 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 213
Critical Load Combination = [80] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 8: EQ-Z-E)
Pu = 2733.2 kN
Mux = 306.75 kNm
Muy = -79.56 kNm
P/A = 223.12 kN/sqm
Mx/Zx = 42.93 kN/sqm

07/03/2024 13:14:22 pm 29/32


My/Zy = -11.13 kN/sqm

Deff = 401 mm
Leff = 3500 mm
SPu = 234.25 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 719.7 kNm
Ast Rqd = 4972.43 sqmm
Ast (min) = 3500 sqmm
Ast Prv (Distributed Across Total Length) = 25 - #16 @ 150
= 5026.5 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total Length) = 29 - #10 @ 125 c/c
= 2277.66 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 417 mm
Critical Analysis Load Combination = 209
Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 2830.49 kN
Mux = 465.18 kNm
Muy = -0.58 kNm
P/A = 231.06 kN/sqm
Mx/Zx = 65.1 kN/sqm
My/Zy = -0.08 kN/sqm

Deff = 417 mm
Beff = 3500 mm
SPu = 296.16 kN/sqm
Vu = SPu X (Loff - d) X B
= 941.19 kN

One Way Shear Along B:


Critical Section @ d from Column Face

= 401 mm
Critical Analysis Load Combination = 213
Critical Load Combination = [80] : 1.68 (LOAD 9: DL) +0.5
(LOAD 10: LL) +(LOAD 8:
EQ-Z-E)
Pu = 2733.2 kN
Mux = 306.75 kNm
Muy = -79.56 kNm
P/A = 223.12 kN/sqm
Mx/Zx = 42.93 kN/sqm

07/03/2024 13:14:22 pm 30/32


My/Zy = -11.13 kN/sqm

Deff = 401 mm
Leff = 3500 mm
SPu = 234.25 kN/sqm
Vu = SPu X (Boff - d) X L
= 757.57 kN

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 204 mm

Critical Analysis Load Combination = 209


Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 2830.49 kN
Mux = 465.18 kNm
Muy = -0.58 kNm
P/A = 231.06 kN/sqm
Mx/Zx = 65.1 kN/sqm
My/Zy = -0.08 kN/sqm

Deff = 409 mm
Leff = 1259 mm
Beff = 1259 mm
Punching Perimeter = 5036 mm
Punching Area = 2059724 sqmm
SPu = Average Pressure
= 231.06 kN/sqm
Vu = { SPu [ (L x B)- (Leff x Beff)]}
= 2464.24 kN
φVn = 4056.37 kN
φVc = 2677.2 kN
No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 500 X 500
= 125 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 209
Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5
(LOAD 10: LL) +(LOAD 4:

07/03/2024 13:14:22 pm 31/32


EQ-X-E)
Pu = 2830.49 kN
A2 = 0.72 sqm
A1 = 8.12 sqm
Base Area = 12.25 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 3.3582
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column
Area
= 22018.84 kN
Φ1Pnb > Pu, Hence Safe.

07/03/2024 13:14:22 pm 32/32