You are on page 1of 1

Mill Status.

xlsx

सोमवार, फ़रवर 12, 2024 09:10:40 Last Stopped Date


Unit#1 Dept. Remarks Stop Date
MILL#1A Mill input shaft oil leakage in stopped condition. BMD Available
Rat Hole suspected in bunker BMD
MILL#1B Bowl Dp value bad (54404) C&I I/S
Reject bypass line damaged BMD
HAD passing 46TPH.(47118). BMD
Pyrite hopper mesh is uneven. BMD
MILL#1C Feeder frequently switching to volumetric mode. C&I/ BMD I/S
Poking hole near bunker O/L bolt missing. BMD
O/S valve inoperative C&I
Coal pipe-1 choking frequently.
BMD
Mill having inpt shaft oil lkg in stopped condition.
MILL#1D BMD u/ptw 05.02.2024
Bypass line height at discharge point (ground clearance) is 300 mm while in other mills ground
BMD
clearance 1m , re-erection required.oversize & bypass v/v not working
MILL#1E Mill reject Bypass pipe damage. BMD I/S
MILL#1F Normal I/S
MILL#1G Mix air duct insulation damaged. BMD I/S
MILL#1H Oversize V/v Inoperative. C&I I/S
Mill-1J having input shaft lkg. BMD 52493. BMD
MILL#1J PF Leakage from Pipe#4 near 1st bend. BMD Available 8.02.2024
oversize v/v inoperative. C&I
Unit#2 Stop Date
MILL#2A Labrynth seal lkg, high fine reject BMD I/S
Feeder#B Main motor GB oil seepage from flange 52168.
MILL#2B Hole in Bypass line BMD I/S
Feeder O/L gate open feedback not available.
Bypass
Labrynthline mouth
seal lkg damage
MILL#2C PF lkg after MDV Pipe-3 near first bend BMD I/S
PF leakage from roller assembly
Labrynth seal lkg, high reject
MILL#2D BMD I/S
Feeder COC not visible through view glass
Inert steam drain valve (before manual valve) gland leakage
BMD
Mill-E coal pipe-1 PF leakage b/w corner-2 & 3
MILL#2E BMD I/S
Hole in Bypass line
C&I
Bypass valve inoperative. Cylinder NA
Mill-2F input shaft oil lkg observed in stop condition.BMD-48024.
Mill-2F pf lkg from MDV-2. BMD
MILL#2F U/ptw 11/02/2024
Labyrinth seal leakage C&I
MIV inoperative
Mill-2G shaft oil leakage in stop condition .BMD-50404. BMD
MILL#2G PF leakage from pipe-3 @ 21 mtr BMD I/S
Hole in Bypass line, MIV not operative C&I
high reject BMD
MILL#2H Mix PA insulation damage BMD u/ptw 01/02/2024
Mill current hunting on load below 30 TPH. C&I
Labrynth seal lkg
BMD
oversize valve inoperative
BMD
Input shaft bearing temperature high.(81 degree @ 40 TPH) ;
BMD
Thrust bearing temp high 51843
MILL#2J BMD I/S
Oil leakage from input shaft in mill stop condition(41371-BMD),
BMD
Feeder I/L and Bunker outlet gate wheel missing.
BMD
Abnormal sound from HAG- seal damage suspected.
BMD
CAG close feedback NA

You might also like