This document is a checklist for structural and masonry works on the NARA Residences Phase 1 project in Bacolod City, Philippines. It lists key performance indicators and acceptance criteria for elements like site clearing, formworks, honeycombing, cracks, levelness, squareness, alignment, thickness, grooves, and edges. The contractor and coordinators must sign off to approve that all criteria are met before work is deemed complete.
Original Description:
Original Title
Copy of ARCHITECTURAL PUNCHLIST - STRUCTURAL AND MASONRY WORKS
This document is a checklist for structural and masonry works on the NARA Residences Phase 1 project in Bacolod City, Philippines. It lists key performance indicators and acceptance criteria for elements like site clearing, formworks, honeycombing, cracks, levelness, squareness, alignment, thickness, grooves, and edges. The contractor and coordinators must sign off to approve that all criteria are met before work is deemed complete.
This document is a checklist for structural and masonry works on the NARA Residences Phase 1 project in Bacolod City, Philippines. It lists key performance indicators and acceptance criteria for elements like site clearing, formworks, honeycombing, cracks, levelness, squareness, alignment, thickness, grooves, and edges. The contractor and coordinators must sign off to approve that all criteria are met before work is deemed complete.
PROJECT: NARA RESIDENCES BY ROCKWELL PHASE 1 DATE PREPARED : WP NO. & SCOPE: PERMIT NO.:
LOCATION: GM Cordova Ave., Buri Road, Bacolod City
PREPARED BY: BUILDING GRIDLINE/AXES: STRUCTURE : DATE OF POURING : AREA/LEVEL: (ENCLOSE KEY PLAN)
(Contractor) (Name/Designation) (Signature)
ARCHITECTURAL INTEGRITY INDICATOR COMPONENTS KPI (Key Performance Indicator) STRUCTURAL MEMBERS REMARKS Site Clearing Acceptability as per coordinator FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS No unstripped formworks allowed Acceptability as per coordinator FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS No liatances allowed Acceptability as per coordinator FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS No honeycomb Maximum diameter of 5 mm FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS All structures must be plumbed maximum deviation of 1 cm per height FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS No cracks on all structures maximum of 2 mm width of hairline cracks FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS No Hollow sound allowed No hollow sound allowed FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Wall levelness of surface All surface must have maximum deviation of 3 mm per 2 m level bar FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Wall squareness Passing 1' x 1' L square for non cabinet areas and 3' x 3' for cabinet areas FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Wall Alignment No misalignment allowed FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Wall thickness on door opening thickness should not exceed door thickness FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Wall groove must be 25 mm max of 3 mm deviation FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Structural and architectural grooves Groove strightness must have max deviation of 3 mm per 1 m FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Groove depth must be consistent. Maximum deviation of 3 mm per 1m FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS All structural and masonry edges must plumbed Maximum 3 mm per height FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS Structural form joints must be smooth All surface must have maximum deviation of 3 mm per 2 m level bar FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS RECOMMENDING APPROVAL: APPROVED BY: NOTED BY