You are on page 1of 1

ARCHITECTURAL PUNCHLIST

CHECKLIST TO STRUCTURAL AND MASONRY WORKS


PROJECT: NARA RESIDENCES BY ROCKWELL PHASE 1 DATE PREPARED : WP NO. & SCOPE: PERMIT NO.:

LOCATION: GM Cordova Ave., Buri Road, Bacolod City


PREPARED BY: BUILDING GRIDLINE/AXES: STRUCTURE : DATE OF POURING :
AREA/LEVEL:
(ENCLOSE KEY PLAN)

(Contractor) (Name/Designation) (Signature)


ARCHITECTURAL INTEGRITY INDICATOR
COMPONENTS KPI (Key Performance Indicator) STRUCTURAL MEMBERS REMARKS
Site Clearing Acceptability as per coordinator FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
No unstripped formworks allowed Acceptability as per coordinator FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
No liatances allowed Acceptability as per coordinator FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
No honeycomb Maximum diameter of 5 mm FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
All structures must be plumbed maximum deviation of 1 cm per height FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
No cracks on all structures maximum of 2 mm width of hairline cracks FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
No Hollow sound allowed No hollow sound allowed FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Wall levelness of surface All surface must have maximum deviation of 3 mm per 2 m level bar FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Wall squareness Passing 1' x 1' L square for non cabinet areas and 3' x 3' for cabinet areas FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Wall Alignment No misalignment allowed FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Wall thickness on door opening thickness should not exceed door thickness FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Wall groove must be 25 mm max of 3 mm deviation FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Structural and architectural grooves Groove strightness must have max deviation of 3 mm per 1 m FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Groove depth must be consistent. Maximum deviation of 3 mm per 1m FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
All structural and masonry edges must plumbed Maximum 3 mm per height FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
Structural form joints must be smooth All surface must have maximum deviation of 3 mm per 2 m level bar FLOOR COLUMNS SHEARWALLS SLABS SOFFIT STAIRS BEAMS
RECOMMENDING APPROVAL: APPROVED BY: NOTED BY

__________________________________ _______________________________________ _________________________________ _________________________________


STRUCTURAL COORDINATOR ARCHITECTURAL COORDINATOR CONSTRUCTION MANAGER PROJECT MANAGER
Form 91-S-011 (Jan 2020)