Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.3

* Calculation of T & L Section Inertia

Project :

1200 mm
250 mm

700 mm

250 mm

I R-sec = 7.15E+09 mm4


yc.g = 220 mm from flange edge
I T-sec = 1.35E+10 mm4 = 1.9 I R-sec

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.3

* Calculation of T & L Section Inertia

Project :

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Design of Slab sections

Project :

Concrete fc` = 32 MPa


Steel fy = 420 MPa

Ult. Moment Breadth Depth Thick. a (b1.c) Ascalc Asmin Used Required
Sec. Notes
Mu (kN.m) b (mm) d (mm) h (mm) (mm) (mm )
2
(mm )
2
As RFT.
1 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
2 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
3 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
4 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
5 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
6 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
7 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
8 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
9 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
10 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
11 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
12 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
13 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
14 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
15 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
16 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
17 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
18 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
19 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
20 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
21 20 1000 120 150 7.0 454 270 454 T 10 @172 safe
22 20 1000 120 150 7.0 454 270 454 T 10 @172 safe

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Design of Slab sections

Project :

Concrete fc` = 32 MPa


Steel fy = 420 MPa

Ult. Moment Breadth Depth Thick. a (b1.c) Ascalc Asmin Used Required
Sec. Notes
Mu (kN.m) b (mm) d (mm) h (mm) (mm) (mm )
2
(mm )
2
As RFT.
23 20 1000 120 150 7.0 454 270 454 T 10 @172 safe

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.4

* Design of Beams

Project :

Concrete fc` = 32 MPa


Steel fy = 420 MPa

None
Comp.
Ult. Moment Breadth Flange Flange Depth a (b1.c) Ascalc Asmin Used Required
Sec. Notes
Mu (kN.m) b (mm) B (mm) side d (mm) (mm) (mm2) (mm2) As RFT.
1 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
2 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
3 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
4 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
5 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
6 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
7 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
8 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
9 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
10 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
11 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
12 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
13 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
14 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
15 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
16 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
17 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
18 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
19 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
20 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
21 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
22 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.4

* Design of Beams

Project :

Concrete fc` = 32 MPa


Steel fy = 420 MPa

None
Comp.
Ult. Moment Breadth Flange Flange Depth a (b1.c) Ascalc Asmin Used Required
Sec. Notes
Mu (kN.m) b (mm) B (mm) side d (mm) (mm) (mm2) (mm2) As RFT.
23 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe
24 200 250 1200 Comp. 650 10.6 821 547 821 5 T 16 safe

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.5

* Design for Shear

Project :

Concrete fc` = 32 MPa


Stirrups fy = 420 MPa Eq. 22.5.5.1 (a)
use Eq. 22.5.5.1 (a) to get Vc Eq. 22.5.5.1 (b)

Ult. Shear Normal Breadth Depth Thick. no. of Long. RFT. fVc Vs As Vu max
Sec. Stirrups Notes
Vu (kN) Nu (kN) bw (mm) d (mm) h (mm) bran. (mm )
2
(kN) (kN) S (kN)
1 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
2 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
3 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
4 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
5 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
6 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
7 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
8 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
9 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
10 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
11 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
12 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
13 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
14 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
15 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
16 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
17 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe
@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.5

* Design for Shear

Project :

Concrete fc` = 32 MPa


Stirrups fy = 420 MPa Eq. 22.5.5.1 (a)
use Eq. 22.5.5.1 (a) to get Vc Eq. 22.5.5.1 (b)

Ult. Shear Normal Breadth Depth Thick. no. of Long. RFT. fVc Vs As Vu max
Sec. Stirrups Notes
Vu (kN) Nu (kN) bw (mm) d (mm) h (mm) bran. (mm )
2
(kN) (kN) S (kN)
18 250 100 250 550 700 2 1200 109.0 188.0 0.407 T 10 @192 659 safe

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.1

* Design of Shear-friction

Project :

Concrete fc` = 32 MPa


Stirrups fy = 420 MPa

###

###
###
###
Ult. Shear Breadth Thick Coff. of friction Angle fVn (max) Avf fVn
Sec. Used RFT Notes
Vu (kN) b (mm) h (mm) (m) (a) (kN) (mm ) 2
(kN)
1 150 250 700 1 90 1,026 476 178 5 T 12 safe
2 150 250 700 1 90 1,026 476 178 5 T 12 safe
3 150 250 700 1 90 1,026 476 178 5 T 12 safe
4 150 250 700 1 90 1,026 476 178 5 T 12 safe
5 150 250 700 1 90 1,026 476 178 5 T 12 safe
6 150 250 700 1 90 1,026 476 178 5 T 12 safe
7 150 250 700 1 90 1,026 476 178 5 T 12 safe
8 150 250 700 1 90 1,026 476 178 5 T 12 safe
9 150 250 700 1 90 1,026 476 178 5 T 12 safe
10 150 250 700 1 90 1,026 476 178 5 T 12 safe
11 150 250 700 1 90 1,026 476 178 5 T 12 safe
12 150 250 700 1 90 1,026 476 178 5 T 12 safe
13 150 250 700 1 90 1,026 476 178 5 T 12 safe
14 150 250 700 1 90 1,026 476 178 5 T 12 safe
15 150 250 700 1 90 1,026 476 178 5 T 12 safe
16 150 250 700 1 90 1,026 476 178 5 T 12 safe
17 150 250 700 1 90 1,026 476 178 5 T 12 safe
18 150 250 700 1 90 1,026 476 178 5 T 12 safe
19 150 250 700 1 90 1,026 476 178 5 T 12 safe
20 150 250 700 1 90 1,026 476 178 5 T 12 safe
21 150 250 700 1 90 1,026 476 178 5 T 12 safe
22 150 250 700 1 90 1,026 476 178 5 T 12 safe
23 150 250 700 1 90 1,026 476 178 5 T 12 safe
24 150 250 700 1 90 1,026 476 178 5 T 12 safe
25 150 250 700 1 90 1,026 476 178 5 T 12 safe

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.4

* Design for Torsion

Project :

Concrete fc` = 32 MPa


Stirrups fy = 420 MPa
Steel fy = 420 MPa

Ult. torsional moment Sec. dim. (mm) Ult. shear force


Sec. Mtu (kN.m) bw h Vu (kN)
1 25 250 700 170

Threshold torsion Tth = 7.6 kN.m Torsion should be calculated

Checking the dimensions:

1.81 < 3.52 Safe

Torsion: Shear:
Required At/S = 0.359 mm Vc = 156.3 kN
Minimum At/S = 0.104 mm Vs = 70.4 kN
Required: Av/S = 0.258 mm
Used Stirrups
T 10 @219 outer T 8 @390 inner
or Total stirrups: T 10 @161 outer

Required Al = 611 mm2


Minimum Al = 379 mm2
Used Horizontal RFT. : 6 T12

T 10 @219
700mm

700mm

T 10 @161

T 8 @390

@seismicisolation
@seismicisolation
250mm OR 250mm

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.0

* Check of Punching without Shear Rft.

Project :

Concrete fc` = 32 MPa

Internal rectangular columns: unbalanced moment


Mft

unbalanced moment
b Mfb
d/2
critical perimeter (bo) t

Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
650 300 600 250 30 Auto 2680 30 40 1.00
t+d b+d d CABt CABb Jct Jcb vug vu,AB f vc Utiliz.
1 g qt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
820 520 220 410 260 6.01E+10 3.05E+10 0.456 0.347 1.10 1.31 1.40 0.94 Safe
Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
650 300 600 250 30 Auto 2680 30 40 1.00
t+d b+d d CABt CABb Jct Jcb vug vu,AB fvc Utiliz.
2 gqt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
820 520 220 410 260 6.01E+10 3.05E+10 0.456 0.347 1.10 1.31 1.40 0.94 Safe

@seismicisolation
@seismicisolation Page 15 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.0

* Check of Punching without Shear Rft.

Internal circular columns:


unbalanced moment
Mfy

d/2 D unbalanced moment


Mfx

critical perimeter (bo)

Ult. Load Col. Dims. Slab Cover Critical bo Mfx Mfy Size factor
Col.
Vu (kN) D (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
420 400 250 30 Auto 1948 30 30 1.00
Deq+d d CABx CABy Jcx Jcy vug vu,AB fvc Utiliz.
1 gqx gqy Notes
Output: (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
574.491 220 287.25 287.25 2.01E+10 2.01E+10 0.400 0.400 0.98 1.32 1.40 0.95 Safe
Ult. Load Col. Dims. Slab Cover Critical bo Mfx Mfy Size factor
Col.
Vu (kN) D (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
420 400 250 30 Auto 1948 30 30 1.00
Deq+d d CABx CABy Jcx Jcy vug vu,AB fvc Utiliz.
2 gqx gqy Notes
Output: (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
574.491 220 287.25 287.25 2.01E+10 2.01E+10 0.400 0.400 0.98 1.32 1.40 0.95 Safe

@seismicisolation
@seismicisolation Page 16 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.0

* Check of Punching without Shear Rft.

unbalanced moment
Mft
Edge columns:

unbalanced moment
b Mfb

d/2

critical perimeter (bo) t

Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
300 300 600 250 30 Auto 1640 30 70 1.00
t+d b+d/2 d CABt CABb Jct Jcb vug vu,AB fvc Utiliz.
1 gqt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm2) ratio
820 410 220 410 102.5 4.12E+10 7.05E+09 0.485 0.320 0.83 1.30 1.40 0.93 Safe
Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
300 300 600 250 30 Auto 1640 30 70 1.00
t+d b+d/2 d CABt CABb Jct Jcb vug vu,AB fvc Utiliz.
2 gqt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
820 410 220 410 102.5 4.12E+10 7.05E+09 0.485 0.320 0.83 1.30 1.40 0.93 Safe
Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
300 300 600 250 30 Auto 1640 30 70 1.00

3
@seismicisolation
@seismicisolation Page 17 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.0

* Check of Punching without Shear Rft.


t+d b+d/2 d CABt CABb Jct Jcb vug vu,AB fvc Utiliz.
3 gqt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
820 410 220 410 102.5 4.12E+10 7.05E+09 0.485 0.320 0.83 1.30 1.40 0.93 Safe

unbalanced moment
Corner columns: Mft

b unbalanced moment
Mfb
critical perimeter (bo)

Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
150 300 600 250 30 Auto 1120 50 50 1.00
t+d/2 b+d/2 d CABt CABb Jct Jcb vug vu,AB fvc Utiliz.
1 gqt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
710 410 220 225.04 75.04 1.44E+10 4.03E+09 0.467 0.336 0.61 1.29 1.40 0.92 Safe
Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls
150 300 600 250 30 Auto 1120 50 50 1.00
t+d/2 b+d/2 d CABt CABb Jct Jcb vug vu,AB fvc Utiliz.
2 gqt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm ) 4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm ) 2
ratio
710 410 220 225.04 75.04 1.44E+10 4.03E+09 0.467 0.336 0.61 1.29 1.40 0.92 Safe
Ult. Load Col. Dims. Slab Cover Critical bo Mft Mfb Size factor
Col.
Vu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) kN.m kN.m ls

@seismicisolation
@seismicisolation Page 18 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.0

* Check of Punching without Shear Rft.


150 300 600 250 30 Auto 1120 50 50 1.00
t+d/2 b+d/2 d CABt CABb Jct Jcb vug vu,AB fvc Utiliz.
3 gqt gqb Notes
Output: (mm) (mm) (mm) (mm) (mm) (mm )
4
(mm ) 4
(N/mm ) (N/mm )
2 2
(N/mm2) ratio
710 410 220 225.04 75.04 1.44E+10 4.03E+09 0.467 0.336 0.61 1.29 1.40 0.92 Safe

@seismicisolation
@seismicisolation Page 19 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.1

* Check of Punching with Shear Rft.

Project :

Concrete fc` = 32 MPa


Conc. vu max = 2.12 MPa
Steel fy = 420 MPa

Internal columns:

Ult. Load Magnif. Col. Dims. Thick Cover Shear no. of RFT no. of RFT Dist. bet. legs Dist. bet. legs X S no. of RFT Stirrups Shear
Col.
Vu (kN) factor b (mm) t (mm) h (mm) (mm) RFT f legs on (b) legs on (t) on "b" l1 (mm) on "t" l2 (mm) (mm) (mm) lines (n) (D/C) stress (D/C)t3
1 680 1.21 300 700 250 30 10 2 4 200 250 110 110 5 0.78 0.91 ###
2 680 1.21 300 700 250 30 10 2 4 200 250 110 110 5 0.78 0.91 ###
3 680 1.21 300 700 250 30 10 2 4 200 250 110 110 5 0.78 0.91 ###
4 680 1.21 300 700 250 30 10 2 4 200 250 110 110 5 0.78 0.91 ###
5 680 1.21 300 700 250 30 10 2 4 200 250 110 110 5 0.78 0.91 ###

Ult. Load Magnif. Col. Dims. Thick Cover Shear no. of RFT Dist. bet. X S no. of RFT lines Shear
Col. Stirrups (D/C)
Vu (kN) factor D (mm) h (mm) (mm) RFT f legs Legs l (mm) (mm) (mm) (n) stress (D/C)
1 650 1.2 500 250 30 10 4 200 110 110 5 0.68 0.84 ###
2 650 1.2 500 250 30 10 4 200 110 110 5 0.68 0.84 ###
3 650 1.2 500 250 30 10 4 200 110 110 5 0.68 0.84 ###
4 650 1.2 500 250 30 10 4 200 110 110 5 0.68 0.84 ###

@seismicisolation
@seismicisolation
Page 20 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.1

* Check of Punching with Shear Rft.

Edge columns:

Ult. Load Magnif. Col. Dims. Thick Cover Shear no. of RFT no. of RFT Dist. bet. legs Dist. bet. legs X S no. of RFT Stirrups Shear
Col.
Vu (kN) factor b (mm) t (mm) h (mm) (mm) RFT f legs on (b) legs on (t) on "b" l1 (mm) on "t" l2 (mm) (mm) (mm) lines (n) (D/C) stress (D/C)t3
1 250 1.51 300 700 250 30 10 2 3 200 250 110 110 4 0.61 0.89 ###
2 250 1.51 300 700 250 30 10 2 3 200 250 110 110 4 0.61 0.89 ###
3 250 1.51 300 700 250 30 10 2 3 200 250 110 110 4 0.61 0.89 ###
4 250 1.51 300 700 250 30 10 2 3 200 250 110 110 4 0.61 0.89 ###
5 250 1.51 300 700 250 30 10 2 3 200 250 110 110 4 0.61 0.89 ###

Corner columns:

Ult. Load Magnif. Col. Dims. Thick Cover Shear no. of RFT no. of RFT Dist. bet. legs Dist. bet. legs X S no. of RFT Stirrups Shear
Col.
Vu (kN) factor b (mm) t (mm) h (mm) (mm) RFT f legs on (b) legs on (t) on "b" l1 (mm) on "t" l2 (mm) (mm) (mm) lines (n) (D/C) stress (D/C)t3
1 130 2.11 300 700 250 30 10 2 4 200 250 110 110 5 0.56 0.91 ###
2 130 2.11 300 700 250 30 10 2 4 200 250 110 110 5 0.56 0.91 ###
3 130 2.11 300 700 250 30 10 2 4 200 250 110 110 5 0.56 0.91 ###
4 130 2.11 300 700 250 30 10 2 4 200 250 110 110 5 0.56 0.91 ###

@seismicisolation
@seismicisolation
Page 21 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.7

* Deflection of Simple R-beams or Slabs

Project :

Concrete fc` = 35 MPa

PDL+ PLL
WDL+ WLL

Span/2 Span/2

Breadth Depth Thickness Span


Sec. Properties of sec: b (mm) d (mm) t (mm) L (m)
1 300 750 800 8

Top Rft.: no. f area


4 16 804 mm2

Bottom Rft.: no. f area


6 22 2281 mm2

Working loads: PDL (kN) WDL (kN/m) PLL (kN) WLL (kN/m)
self weight 40 20 50 20
finish+walls 25 10 sustained LL = 25%

Ec = 27806 MPa
n= 7.19
Z= 226.7 mm
Ig = 1.28E+10 mm4
Icr = 5.81E+09 mm4
Ieff = 5.86E+09 mm4

Immediate deflection = 23.9 mm


Creep factor lD = 1.71 for 60 months
Total deflection = 40.6 mm Unsafe, camber may be used

Allowable value = 33.3 mm Non-structural elements not likely to be damaged

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Deflection of Simple T-beams

Project :
B

Concrete fc` = 35 MPa C As top ts

PDL+ PLL
WDL+ WLL
b
h

Span/2 Span/2

C As bottom

Breadth Depth Thickness Span


Sec. Properties of sec: B (mm) b (mm) ts (mm) h (mm) t (mm) L (m)
1 1500 300 140 760 900 10

Top Rft.: C (mm) no. f area


40 6 18 1502 mm2

Bottom Rft.: C (mm) no. f area


60 12 22 4505 mm2

Working loads: PDL (kN) WDL (kN/m) PLL (kN) WLL (kN/m)
self weight 40 20 30 8
finish+walls 50 10 sustained LL = 25%

Ec = 27,806 MPa
n= 7.19
Z= 167.6 mm
Ig = 3.35E+10 mm4
Icr = 1.71E+10 mm4
Ieff = 1.74E+10 mm4

Immediate deflection = 15.4 mm


Creep factor lD = 1.56 for 60 months
Total deflection = 27.5 mm Safe

Allowable value = 41.7 mm Non-structural elements not likely to be damaged

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.7

* Deflection of Cantilever Beams or Slabs

Project :

Concrete fc` = 35 MPa

PDL+ PLL
WDL+ WLL

Span

Breadth Depth Thickness Span


Sec. Properties of sec: b (mm) d (mm) t (mm) L (m)
1 1000 220 250 2.5

Top Rft.: no. f area


5 20 1571 mm2

Bottom Rft.: no. f area


5 16 1005 mm2

Working loads: PDL (kN) WDL (kN/m) PLL (kN) WLL (kN/m)
self weight 2.50 6.25 0 3.00
finish+walls 0.00 3.50 sustained LL = 25%

Ec = 27806 MPa
n= 7.19
Z= 57.7 mm
Ig = 1.30E+09 mm4
Icr = 3.66E+08 mm4
Ieff = 4.69E+08 mm4

Immediate deflection = 5.8 mm


Creep factor lD = 1.67 for 60 months
Total deflection = 10.4 mm Safe

Allowable value = 10.4 mm Non-structural elements not likely to be damaged

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.2

* Design of Isolated Footings

Project :

Concrete f c` = 30 MPa
Steel fy = 420 MPa
Bearing capacity qall = 150 kN/m2

Column working load Column dim. Extension


foot Nw (kN) b (mm) t (mm) of P.C (mm)
F1 1500 300 600 100

Dims. of P.C : B (mm) L (mm) t (mm)


3,300 3,600 100

Dims. of R.C : B (mm) L (mm) t (mm) c (mm)


3,100 3,400 800 75

Actual soil stress (kN/m2) D/C Stress above P.C (kN/m2)


148 0.99 162

Shear stress (N/mm2) vc (N/mm2) D/C


0.33 < 0.75 * 0.44 0.99

Punching force (kN) Vc (kN) D/C


1791 < 0.75 * 6159 0.39

Calculation of Rft. : Asmin


1440 mm2

Long Direction : Mu /m As /m T total no.


223 1440 16 @139 23

Short Direction : Mu /m As /m T total no.


223 1440 16 @139 25
16 @133 for 3.10m
and 16 @266 for rest

Crack width check:


Maximum moment = 159 kN.m/m in the Long direction
Used RFT.: T 16 @139 to satisfy crack width
@seismicisolation
@seismicisolation
Neutral Axis depth (Z) = 117 mm
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 2.2

* Design of Isolated Footings


Tens. Steel stress (fs) = 159 MPa < 250 MPa Acceptable
Crack width (w) = 0.22 mm < 0.3 mm Acceptable

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.7

* Design of Combined Footing

Project :

Concrete Cyl. strength fc` = 30 MPa


Steel Yield stress fy = 420 MPa
Soil Bearing Capacity qall = 150 kN/m2

F1
Column working load Column dim. Extension
Nw (kN) Trans. Long. of P.C (mm)
Smaller 1000 250 500 100
Larger 1500 250 800 100

Distance from c.g to c.g: 2.5 m

Resultant of 2 loads is at: 1.50 m from smaller column

Dimensions B (mm) L (mm) t (mm) c (mm) Stress below (kN/m2)


P.C 3,200 6,000 100 137.2 Safe
R.C 3,000 5,800 900 75 166.2

Max. Shear stress (N/mm2) vc (N/mm2) D/C


0.30 < 0.75 * 0.44 0.92

Max. Punching stress (N/mm2) vc (N/mm2) D/C


0.35 < 0.75 * 1.81 0.26 for smaller column
0.47 < 0.75 * 1.50 0.42 for larger column

Calculation of Rft. : Asmin


1620 mm2

Longitudinal Direction : Mu /m As /m T total no.


Top 0 1620 16 @124 25
Bottom 420 1620 16 @124 25 ###

Transverse Direction : Mu /m As /m T total no.


Top 12 @200 29 ###
Bottom 270 1620 16 @124 47 ###

Crack width check:


Maximum moment = 300 kN.m/m in the Longitudinal Direction

@seismicisolation
@seismicisolation
Page 27 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.7

* Design of Combined Footing


Used RFT.: T 16 @124 to satisfy crack width
Neutral Axis depth (Z) = 133 mm
Tens. Steel stress (fs) = 235 MPa < 250 MPa Acceptable
Crack width (w) = 0.30 mm > 0.3 mm Not acceptable

5.80 m

T16 @124

900
3.00 m

3.20 m
T12 @200

T16 @124
+

1.50 m

T16 @124

6.00 m

@seismicisolation
@seismicisolation
Page 28 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Design of Pile Cap

Project :

Concrete Cyl. strength f c` = 30 MPa


Steel Yield stress fy = 420 MPa

Pile Diameter = 500 mm

Pile Comp. Load Capacity = 600 kN

###
Column working load Nw Column dim. Extension ###
cap (kN) b (mm) t (mm) of P.C (mm) ###
PC1 2500 400 800 100 ###
###
Estimated no. of piles = 5 piles ###
###
Pile spacing is taken from 1250 to 3000 mm = 1.50 m in long direction
###
###
Pile spacing is taken from 1250 to 3000 mm = 1.50 m in short direction
###
###
Short dir. Long dir. ###
Choosen arrangement of piles = 2 x 3 Piles used = 6 ###
###
Dims. of P.C cap: B (mm) L (mm) t (mm) ###
3200 4700 100 ###
###
Dims. of R.C cap: B (mm) L (mm) t (mm) c (mm) ###
3000 4500 1100 75 ###
###
Actual pile load (kN) D/C ###
484 0.81 ###
###
Shear stress (N/mm2) vc (N/mm2) D/C l
0.32 < 0.75 * 0.44 0.99 in Long direction ###
in short direction 100% of first pile row is subtracted Short
in long direction 31% of first pile row is subtracted

Punching stress (N/mm2) vc (N/mm2) D/C Vc


0.56 < 0.75 * 1.81 0.42 ###
a

@seismicisolation
@seismicisolation
Page 29 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Design of Pile Cap


Calculation of Rft. : Asmin ###
1980 mm 2
###

Long Direction : Mu /m As /m T total no.


497 1980 20 @159 19 ###
###
Short Direction : Mu /m As /m T total no.
248 1980 20 @159 29 ###
OR 20 @132 for 3.00 m ###
and 20 @264 for rest ###

Crack width check: a


Maximum moment = 355 kN.m/m in the Long Direction b
Used RFT.: T 20 @159 to satisfy crack width c
Neutral Axis depth (Z) = 163 mm z
Tens. Steel stress (fs) = 184 MPa < 250 MPa Acceptable I
Crack width (w) = 0.25 mm < 0.3 mm Acceptable

4500

1100
T 20 @159
3000

3200

T 20 @159

@seismicisolation
@seismicisolation
Page 30 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Design of Pile Cap

4700

@seismicisolation
@seismicisolation
Page 31 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Design of Pile Cap under Moment

Project :

Concrete Cyl. strength f c` = 30 MPa


Steel Yield stress fy = 420 MPa

Pile Diameter = 500 mm

Pile Comp. Load Capacity = 600 kN

Column working load Nw Column dim. Working moment Extension


cap (kN) b (mm) t (mm) Mw (kN.m) of P.C (mm)
PC1 2040 800 800 1000 100

Spacing of piles in direction of moment = 1.50 m no. of Piles 4

Spacing of piles in transverse direction = 1.50 m no. of Piles 3


Total no. of piles = 12 ###
###
Dims. of P.C cap: B (mm) L (mm) t (mm) ###
4700 6200 100 ###
###
Dims. of R.C cap: B (mm) L (mm) t (mm) c (mm) W
4500 6000 1200 75 ###
###
Max. Load (kN) Min. Load (kN) ###
1st piles row to center, y1 0.75 m 287 198 ###
2nd piles row to center, y2 2.25 m 376 110 ###
3rd piles row to center, y3 0.00 m 242.8 242.8 ###
4th piles row to center, y4 0.00 m 242.8 242.8 ###
All Safe ###
###
Shear stress (N/mm2) vc (N/mm2) D/C l
0.31 < 0.75 * 0.44 0.95 in Long direction ###
100% of first pile row is subtracted
ro
Punching stress (N/mm ) 2 vc (N/mm ) 2
D/C Vc
0.33 < 0.75 * 1.81 0.24 ###
a
Calculation of Rft. : Asmin ###
2160 mm2 ###

Long Direction : Mu /m As /m T total no.


743 2160 20 @145 31 ###
###
@seismicisolation
@seismicisolation

Page 32 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.6

* Design of Pile Cap under Moment


Short Rft. : Mu /m As /m T total no.
419 2160 20 @145 42 ###
OR 20 @127 for 4.50 m ###
and 20 @254 for rest ###

Crack width check: a


Maximum moment = 531 kN.m/m in the Long Direction b
Used RFT.: T 20 @145 to satisfy crack width c
Neutral Axis depth (Z) = 179 mm z
Tens. Steel stress (fs) = 230 MPa < 250 MPa Acceptable I
Crack width (w) = 0.31 mm > 0.3 mm Not acceptable

6000

1200
T 20 @145
4500

4700

T 20 @145

6200

@seismicisolation
@seismicisolation

Page 33 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.1

* Design of Cantilever Retaining Wall

Project :

Concrete fc` = 30 MPa

Steel Yield stress fy = 420 MPa 0.25 2.0 kN/m`


Bearing capacity qall = 150 kPa

Retained Soil

Soil above footing: Taken g = 18.0 kN/m3

3.00

2.80
ko = 0.50 C = 0.0 N/mm2

Soil perssure on toe side: f = 30 o


0.50 1.750 0.000
at rest case (conservative) ka = 0.33

0.50 R.C
0.00 P.C
0.00 2.00 0.00

2.00
Foundation soil C= 0.0 N/mm2 f = 30 o

Coefficient of friction (m) = 0.38


Sliding check:
Stabilizing force from: kN Horizontal force from: kN
Weight of wall 18.75 Active earth pressure on wall 23.52
Weight of footing (RC+PC) 25.00 Active earth pressure on footing 9.15
Weight of soil on active side 0.00 Active surcharge pressure 2.20
Weight of soil on passive side 15.75 Passive earth pressure on wall -1.13
Surcharge 0.00 Passive side pressure on footing -3.38
Total weights: S= 59.50 Driving force: S = 30.37

Factor of safety against sliding = 0.75 < 1.5 Not satisfactory

Over-turning check:
Stabilizing moment from: kN.m Over-turning moment from: kN.m
Weight of concrete 60.16 Active earth pressure 35.94
Weight and pressure of soil 15.28 Active surcharge pressure 3.63
S= 75.44 S = 39.57
@seismicisolation
@seismicisolation
Page 34 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.1

* Design of Cantilever Retaining Wall

Factor of safety for overturning = 1.91 > 1.5 Satisfactory

Bearing capacity check:


Moment on footing center = 23.63 kN.m
Total weight on footing = 59.50 kN Eccentricity = 0.40 m
Max. stress on soil = 65.2 kPa Safe stress
Min. stress on soil = -5.7 kPa Tension on soil
Max. stress on soil = 65.2 kPa Safe stress
After Redistribution
Min. stress on soil = 0.0 kPa

Calculation of Rft. :
Mu (kN.m) c (mm) d (mm) As (mm2) As min
For Wall 40.1 50 200 542 450 5 f 12 /m
For Base 51.9 75 425 325 900 8 f 12 /m

Shear on base: Vu = 37.2 kN < Vc = 153 kN Safe

@seismicisolation
@seismicisolation
Page 35 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.1

* Design of Deep Beam

Project :

Concrete Cyl. strength f c` = 32 MPa


Steel Yield stress fy = 420 MPa

Width (b) = 0.30 m


Span (L) = 4.00 m
Height (H) = 3.50 m
L/H = 1.14 Deep Beam

Wu = 120.0 kN/m
Mu = 240.0 kN.m
Vu = 240.0 kN.m
Safe dimensions
Web RFT = T 10 @ 209 2 Legs , Vertical
T 10 @ 209 2 Legs , Horizontal

As calc = 230.8 mm2


As min = 300.0 mm2
As used = 300.0 mm2
2 T 16

T 10 @209
3.50

T 10 @209

2 T 16

@seismicisolation
4.00
@seismicisolation
@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 224R-01 By: Dr. Mahmoud El-Kateb
Version 1.4

* Calculation of Crack Width

Project :

Concrete Cyl. strength fc` = 31 MPa


Steel Yield stress fy = 420 MPa

Comp. side
Thickness

Z
N.A

Tens. side
Breadth

INPUT DATA:
Breadth (B) = 1000 mm
Thickness (t) = 300 mm
Tension RFT. = 10 T 18 = 2545 mm2 Acceptable
Tension RFT. Cover = 40 mm
RFT in perpendiculatr dir. = 6 T 14 (Two way slabs
Short / Long span = 1 Span: Simple only)

Compression RFT. = 10 T 14 = 1539 mm2


Compression RFT. Cover = 40 mm

Mservice = 53 kN.m
Nservice = 100 kN Tension
Exposure condition: Water-retaining structures
Reasonable crack width = 0.10 mm One way member
Exposure: Severe enviroment, exposure to liquid with pH < 5 ACI 350M-06
Structural system: One way member Clause 10.6.4

OUTPUT DATA:
Modular ratio (n) = 7.6
Neutral Axis depth (Z) = 64 mm
Tens. Steel stress (fs) = 112 MPa Acceptable

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 224R-01 By: Dr. Mahmoud El-Kateb
Version 1.4

* Calculation of Crack Width


b= 1.20

Crack width (w) = 0.10 mm Not Acceptable


Max. bar spacing = 300 mm ACI 318M-14, clause 24.3.2
Allowed Tens. Steel stress = 244 MPa ACI 350M-06, clause 10.6.4

@seismicisolation
@seismicisolation
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.1

* Development & Splice of Reinforcement

Project :

Concrete Cyl. strength f c` = 32 MPa


Steel Yield stress fy = 420 MPa

Development of Straight bars in tension:


Bar surface condition:
Uncoated or galvanized ye = 1
Casting position:
More than 300 mm of concrete placed below yt = 1.3
Reinforcement grade:
Grade 280 or Grade 420 yg = 1
Spacing and cover:
Clear spacing not less than db, clear cover at least db and stirrups throughout ld not less than Code minimum
Development Length, Ld = 46 db for db 16 = 736 mm

Lap splice in tension:


As,provided / As,required = <2
Percent of spliced bars = Max. 50% Splice type:
Splice Length, Lst = 60 db for db 16 = 960 mm

Development of Straight bars in compression:


Confinement condition:
Other cases
T yr = 1
Development Length, Ldc = 19 db for db 16 = 304 mm

Lap splice in compression:


Splice Length, Lsc = 30 db for db 16 = 480 mm

@seismicisolation
@seismicisolation
Page 40 of 43
Reinforced Concrete design according to ACI 318-19 By: Dr. Mahmoud El-Kateb
Version 1.1

* Development & Splice of Reinforcement

Standard hooks in tension:


Bar surface condition:
Uncoated or galvanized ye = 1
Location:
Hooked bars terminating inside column core with side cover ≥ 65 mm yo = 1
Confinement reinforcement:
Other conditions yr = 1.6
Concrete strength:
For fc′ < 42 MPa yc = 0.905
Ldh = 8 db for db 16 = 150 mm
Lext = 12 db for db 16 = 192 mm

@seismicisolation
@seismicisolation
Page 41 of 43
By: Dr. Mahmoud El-Kateb

ess than Code minimum


Clause 25.4.2.1

Class B
Clause 25.5.2.1

Clause 25.4.9.1

Clause 25.5.5.1

@seismicisolation
@seismicisolation
Page 42 of 43
By: Dr. Mahmoud El-Kateb

Clause 25.4.3.1
90-degree hooks

@seismicisolation
@seismicisolation
Page 43 of 43