You are on page 1of 1

Find reinforcement for resisted horizontal shear in composite slab, ACI318‐14 Project FIT 2.

5
slab name plinth of ' CE‐20D'

Vu = The maximum vertical shear force at new & existing surface = 4,608 kg.

Vn = The nominal horizontal shear strength.

bv = the width of cross section at contact surface being = 1 m.


investigated for horizontal shear

 = strength reduction factor = 0.75

h = The totally depth of composite section = 30 cm +50 cm = 80 cm.

d = distance from compression fiber to centriod = 65 cm. >0.8h OK


of tensiob bar of composite section

fc' = the ultimate strength of concrete at 28 days = 280 ksc.


( fc' min between existing and new plinth)

db = diameter of re‐bar = 16 mm.

fyt = the yeild strength of transfer reinforcement = 4000 ksc.

Ø 35*bv*d = 0.75*35*100*65 = 170625 kg. , ACI318‐14, 16.4.4

In case of Vu < Ø*35 bv*d , find Nominal horizontal shear strength


Vn = 5.5*bv*d , concrete placed against hardened concrete not intentionally roughened., Table16.4.4.2, ACI318‐14
= 5.5*100*65
= 35750 kg.

Vn = 0.75*35750
= 26,812.5 kg > Vu OK

Find re‐bar requirement for resisted horizontal shear


S= spacing of shear transfer reinforcement ( assume) = 35 cm. <60 cm, OK
bw = the width of cross section = 35 cm.

make roughen 0.25 in


DB16@350MM #

Check minimum of shear reinforcement within spacing S, ( ACI 318 , 16.4.6.1)


Av,min = MAX [ 0.2fc'0.5 bw*s/ fyt, 3.5 bw*s/fyt] , ACI318‐14, 16.4.6.1 80cm.
= MAX[1.02,1.07]
existing slab
= 1.07 cm2 < 2.01 cm^2 OK