You are on page 1of 11

Tutorial Example For PSV Sizing By: A-BOUDERAA

Deny Aditya Pratama, S.T.


Process
ProcessEngineer
Engineer/Aspen HYSYS Expert User Certified
https://www.linkedin.com/in/denyadityap/
2- Add PSV

Double click on PSV takes you


to PSV Environment

1-First go to safety analysis


environment
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

3-Put in the
design conditions
of the vessel
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

6-Open
scenario

5- Define a
scenario

4-Go to scenarios
and click on create
scenario
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

7-Select the
proper
method for
reliving phase

9-Enter the vessel


specifications

8-Select a
calculation
method
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

Review
reliefing fuild
properties

Calculated
reliefing flow 10-Select an
Orifice of PSV
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

11-Go to
PRD Data

12-Choose
PSV type
and body
material
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

13-Use Rating if
you want to
select multiple
valve splitting
configuration
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

14-Now let's do a ligne sizing

15-Inlet
specifications of
your lignes
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

16-check the
calculated Dp is
less then
maximum DP
Deny Aditya Pratama, S.T.
Process Engineer
https://www.linkedin.com/in/denyadityap/

17- Use Built-in


HYSYS reports
to get your
summary results
in PDF
Deny Aditya Pratama, S.T.
PSV Calculation Report - 2-Phase - Direct Method Sizing Case Process Engineer
Valve General Data https://www.linkedin.com/in/denyadityap/
Item 100 PSV 001 Design Code ASME VIII

Service Design Temperature 350.00 °F

Fluid Vap @Main State Vapor Fire Case True

Valve Type Conventional Phase Direct Emergency Fire

Body Mat'l Stainless Steel Rupt. Disk False Discharge To Flare

PSV Coefficients

Kv 1.000 Kb 1.000
0 0
Kd 0.850 Kc 1.000
0 0

Process Data @ Relieving

Superimposed Const. 14.70 psiA


Back Press.
Relieving Flow 35738.18 lb/h Var. 0.00 psi

Relieving Temp 409.41 °F Builtup Back Press 70.00 psi

Set Pressure 700.00 psiG Total Back Press 70.00 psiG

Over Pressure 21.0 %

Valve Sizing Results

Type of Flow Critical Selected Orifice 1.29 in² % Used 58.8 %

Calculated Orifice 0.76 in² Orifice Designation 3 "# 600 J 4 "# 150

Calculation Notes

Record 1 of 1 2/10/2024 4:34:27 PM