You are on page 1of 1

2612 Howard Street

Louisville, KY 40211
RFQ / SO# N/A TEL: +1 502-774-6011
FAX: +1 502-774-6300
Email: ttaftermarket@sypris.com
INSULATED JOINT APPLICATION DATA SHEET

Date 10-Apr-2024 Your Reference No. N/A


Company GAES Contact Info. Alberto Rivera
Email ariveraf@gaes.mx Telephone (+52) 5580685012
Project Name Gasoducto Libramiento Reynosa End Use Location Reynosa, Tams. MX

Required Information Item 1 Item 2 Item 3


Quantity 14
Pipe OD (NPS) 24
Matching Wall Thickness 0.625
Matching Wall Grade (1)
Design Pressure 981
Design Temperature 60
MDMT (Min. Design Metal Temp)
Std or Double Groove (2) Std Dbl Std Dbl Std Dbl
Pressure Part Mat'l Cert. 3.1 3.1 3.1
Construction Code B31.8
Design Factor (3) 0.70
Pups Required (4) N Y N Y N Y
Special Req.: (NDE, Origin, Coating/Paint, etc.)
Please include NDE, certifications, origin, EN 1024 - 3.1
Welds: W1-W2-W3 ACCORDING TO ASME IX - API 1104
Regarding the pups, please we are open to hear recommendations from you and your expertise.
*See technical specification and data sheet. Any deviation, please feel free in contact me. We can
schedule a technical meeting to clarify any doubt or discrepancy.

Digitally signed by
Michael Wood
DN: cn=Michael
Wood, o=Sypris
Technologies, Inc -
Tube Turns Products,
ou=Sr. Project
Engineer,
email=Michael.Woo
d@sypris.com, c=US
(1) Material and Yield strength of component/equipment that IJ will be welded to. Date: 2021.06.15
(2) Refers to the O-ring Groove 07:26:03 -04'00'

(3) If not suplied, 0.72 DF will be assumed.


Form# TTF-40-002
(4) Customer supplied pipe.