2) Use of Pressure
When 2kaf of power is applied to small piston based on both gate cross-section of communicating tu
be ratio is 1:50, it counterbalances with putting 100kgf of weight on large piston.
It shows that the power can be increased by liquid also as same as the principle of leverage.
Push 1cm cross-section of piston 50cm Push 50cm cross-section of piston 1cm
downwards with 2kgf. upwards.
W
F
2kgf 100kgf
Piston A Piston B
h2
1cm
h1
50cm
P- 3
1-2 Property and Principle of Fluid
It needs to understand hydraulic devices correctly and mechanical property of fluid that transmit conversion
of energy, for understanding hydraulic unit and circuit.
1) Unit
Units that applied in this text are all Sl and other units that can be combined with Sl (refer to JIS Z8202).
(Refer to attached technical document for unit conversion.)
2) Density and Weigh Volume Ratio
γ=ρ g based on density is ρ, weigh volume ratio is γ, and acceleration of gravity is g . V2
3) Continuous Formula
A2
Fluid has steady flow and unsteady flow. Steady flow does not changed the condition
(flow speed, pressure, density, and temperature) by time, and unsteady flow changed.
In the mid-flow (refer to right figure), it is often unsteady flow when more appropriate.
However, it shall be handled as steady flow under certain condition.
In case of steady flow, the passing flow volume Q is constant at any cross section.
Q = v1A1=v2A2
A1: Cross Section (cm2) V1
A2: Cross Section (cm )2
P- 4
4) Bernoulli’s Principle
It has three kinds of energy; kinetic energy of liquid, energy of pressure, and energy of position. Energy cons
ervation law work out in case of no energy change in mid-flow of steady. Even fluid changes
the condition while flowing, summation of kinetic energy of liquid, energy of pressure, and energy of position is
not changed according to energy conservation law. Below figure shows summation of kin
etic energy and pressure energy is constant when flow pass is horizontal and flow volume is constant.
B
Summation of kinetic energy and pressure
A C energy is constant when flow pass is
horizontal and flow volume is constant.
Figure shows how pressure changes by
flow speed.
Bernoulli’s principle is expressed as
following formula.
2 2
● v 1 p1 v 2 p2
+ + h1 = + + h 2 = Constant
● ●
2g r 2g r
h : Position Head
v1, v2 : Flow Speed (m/s)
Flow speed is high and
pressure is weak at small If ignore friction in pipe, the p1, p2 : Pressure (kgf/m2)
cross-section area. pressure and flow speed become the r : Weigh Volume Ratio of Fluid (kgf/m3)
same as A again. g : Acceleration of weight (m/s)
P- 6
No. Name Symbol Description
Accumulator Use it when put in and compress nitrogen gas and release
8 ACC large volume of oil.
B
One Direction A → B is controlled flow
13 Throttle Valve
B → A is free flow
A
P- 7
No. Name Symbol Description
B
Check Valve for Pilot A → B is free flow.
14 Operation B → A flow when pressure is applied at pilot A, and not
flow if pressure is not applied at pilot.
A
B
Check Valve for Pilot A → B is free flow.
15 Operation B → A flow when pressure is applied at pilot, and not
External Drain with Spring flow if pressure is not applied at pilot.
A
p1
Relief Valve Keep P1 side pressure setting value.
16 Internal Pilot
Connect P2 side to tank.
Internal Drain p2
Unload Relief Valve This valve is used for accumulator circuit mainly.
17 Internal Pilot
External Pilot p T
p1
Sequence Valve Transmit P1 side oil to P2 side with setting pressure.
18 External Pilot
External Drain p2
p1
Unload Valve Transmit P1 side oil to P2 side with under setting pressure.
19 Internal Drain Connect P2 side to tank.
p2
p1
Pressure Reducing Valve Keep P2 side pressure setting value.
20
Settable as under P1 side pressure.
p2
P- 8
No. Name Symbol Description
P
Proportional Electromagnetic Pressure can be controlled continuously by changing input
21 Relief Valve
current of direct current solenoid.
T
P- 9
No. Name Symbol Description
A B
Servo Valve Typical Example
35
P T
Thermometer
37
Hydraulic Cylinder
38
39
40
41
P- 11
Description of Hydraulic Device Name Plate
1) Relief Valve
Design No.
03 (3/8inch)
Valve Size
06 (3/4inch)
(Pipe Size)
10 (11/4inch)
P- 12
Direction Change Valve
P P
T T
Number of Switching
Position B: 2 positions, One side solenoid
(Spring off set)
Sprue Spring Type
C: 3 positions, Both sides solenoid
( Spring center)
A B
0 3 The moment it turns neutral, P, T, A, and B are connected
1 to tank and become O.
P T
2 2 When port is blocked temporally, the accuracy is the best
2 but it leaks by long time.
P- 14
No. Symbol of Center Position TOKIMEC YUKEN Description
2A 2B2 Pressure have been kept while each port changing because
26 there are 2 molds between 2 positions.
P- 15
YUKEN, TOKIMEC Direction Change Valve Comparative Table
Upper = Dry Type / Lower = Wet Type
3 位置形
スプリングセンタ-
A B
A B
a b a b
P T
P T
P- 16
2 Position Type
Spring Off Set
DG5S4-**2A DSHG-**-2B2
DG5V-**-2A DSHG-**2B2-51
A
B DG4S4-012A DSG-03-2B2
b
DG4V-5-2A DSG-03-2B2-50
P
Note)
T 1 of orifice DG4S4-01**-50-S94
in pilot P port DG4V-5-**-M-PL-T-6-40-P10
DG5S4-****-T-52 DSHG-**-***-T-A100-P-41
Internal Drain Type DG5V-**-**-T-P2-T-80-JA DSHG-**-***-T-A100-P-51
DG5S4-****-E-52 DSHG-**-***-E-A100-P-41
External Pilot Type
DG5V-**-**-E-P2-T-80-JA DSHG-**-***-E-A100-P-51
Internal Drain DG5S4-****-E-T-52 DSHG-**-***-ET-A100-P-41
External Pilot Type
DG5V-**-**-E-T-P2-T-80-JA DSHG-**-***-ET-A100-P-51
* Valve with underline shows pilot valve of double valve. (The size shall be different for wet type.)
* Pilot valve for wet type shall be below (1/8inch). (Spring Center Type)
TOKIMEC = DG4V-3-6C-M / YUKEN = DSG-01-3C4-50
P- 17
Form of Pilot Pressure and Drain TOKIMEC DG5 V -H8-6C
YUKEN DSHG-06-3C4
Drain
P Drain p.p
Dr Dr
T P T
A B A B
① Internal Pilot, External Drain (Standard) ② External Pilot, External Drain with E (High-Speed Mold
Close Valve)
TOKIMEC DG5 V -H8-6C
(Pilot PP is not connected to P. Operate adopting pilot
YUKEN DSHG-06-3C4 Note) With T is internal pilot, internal drain. pressure from outside.)
With E is external pilot, external drain. TOKIMEC DG5S4- H8- 6C-E
YUKEN DSHG-06-3C4-E
P
p.p
T
T
P
A B
A B
③ Internal Pilot, Internal Drain with T (Mold Close Valve) ④ External Pilot, Internal Drain
Positive displacement is used for most of those, and vane, gearwheel, and piston type are typical.
Principle of Pump By capacity change of vane and By move of capacity surrounded Capacity change by back-and-forth
Operation cam ring pipe. gear slot and casing. of piston.
Pressure
2 ~ 17 MPa 2 ~ 17 MPa 3 ~ 35 MPa
Outlet Volume
2 ~ 950Γ/min 7 ~ 570Γ/min 2 ~ 1700Γ/min
P- 19
Structure of Vane Pump
By capacity change between vane and cam ring.
Outlet
TOKIMEC (SQP Series)
Vane
Rotor
Inlet
Vane
Rotor Cam Ring
Shaft
P- 20
Single Level Vane Pump
Outlet
Hydraulic Symbol
Outlet
Inlet
Inlet P- 21
Double Vane Pump
Hydraulic Symbol
P- 22
Relief Valve
Relief Valve
P
1) Intended Use
① It is a pressure control valve to keep primary
Pilot Spacer (C) (c) Pilot Poppet
side pressure constant.
T ② It is a safety valve to protect hydraulic devices.
Hydraulic
Indication Symbol 2) Operation
① Oil in chamber (A) on primary side pressure port
get through hole (a) and flow in chamber (B),
get through hole (b) and flow in chamber (C),
get through hole (c), then pressure is applied to
(b)
poppet.
Vent Port ② When pressure in chamber (C) become more
(B) than spring A setting pressure; poppet is pushed
open, get through hole (d) and flow in tank port, a
(a) nd pressure in chamber (B) decrease rapidly
at the same time.
Pressure Port ③ Pressure difference happens between chamber
(A) (A) and (B) ((A) > (B)), hydro-cone piston rises,
Piston pressure port and tank port are connected, and
oil flow from chamber (A) to (D).
④ Pressure in chamber (A) decrease, and hydro-
Tank Port
(D) cone piston lower repeatedly by spring B as
(d) keep primary side constant.
BG - 06 -* (YUKEN)
P- 23
Unload Relief Valve
Unload Relief Valve 1) Intended Use
It is pressure control valve that makes unload to tank
Hydraulic Indication Symbol with no-load; when line pressure exhausted from pump
does not reach to setting pressure, all exhausted flow
volume on load on secondary side, and it reaches to
Drain
Chamber (E) Chamber (C) P T setting pressure.
Port
2) Operation
① It is a valve combined relief valve and check valve.
(a) ② Push open poppet of check valve with primary side
pressure, and flow in to secondary side circuit.
③ When secondary side pressure have become equal
to primary side pressure, check valve closes by spring.
④ Secondary side pressure get through hole (a) and flow
in chamber (D). When the pressure exceed setting
Secondary Side Chamber (B)
value, poppet is pushed open by pilot piston and
release oil in chamber (B), (C) to drain port.
⑤ Pressure difference happens between chamber
(A) and (B), hydro-cone piston rises, oil flow out from
Inlet Port
chamber (A) to (D), and primary side pressure
Primary Side
Chamber (A) decrease rapidly and become unload condition.
⑥ When secondary side pressure (pressure in chamber
(E)) decrease; poppet closes, pressure difference
between chamber (A) and (B) is reduced, hydro-cone
Tank Port
Chamber (D) piston lower, inlet port and tank port are blocked,
primary pressure increase, poppet of check valve open,
oil flow in secondary side, and it becomes on load
condition.
BUCG - 06 -* (YUKEN)
P- 24
Sequence Valve
1) Intended Use
Sequence Valve Connect primary side pressure and secondary side
pressure by external pilot pressure, and release to tank.
A
(Example of Use: RG15)
2) Operation
① Pilot pressure flow in from X port get through hole (a),
and push sprue by pilot piston. When the pressure
B
become more than spring that set based on adjustment sc
Hydraulic Indication Symbol rew, oil in chamber (A) flow out to chamber (B).
② When pressure of external pilot have decreased, sprue
returns by spring power and chamber (A) and (B) are
blocked.
(Y)
Internal Pilot External Drain Sequence Valve
(B)
(X) Secondary
Side
(A)
External Pilot External Drain Sequence Valve
Primary
Side
P1
1) Intended Use
① It is a pressure control valve to keep secondary side
pressure constant.
② It is used when you want use partial pressure of
Drain Port hydraulic circuit as lower than main circuit.
(Example of Use: Core Circuit)
RG - 06 -* (YUKEN)
P- 26
Check Valve
(with spring)
A B
1) Intended Use
Use for preventing reverse flow.
2) Operation
① In case of free flow, poppet moves backward and oil flow from
in-port (A) to out-port (B) when hydraulic pressure on in-port (A)
side become more than spring power.
In-Port (A) Out-Port (B)
② In case of reverse flow, oil on chamber (B) doesn’t flow to chamb
CRG – 06 – * (YUKEN)
er (A) because poppet blocks the pass by spring power.
P- 27
Flow Volume Adjusting Valve with Check
Throttle Valve
A B
P- 28
Pilot Check Valve B
1) Intended Use
① Free flow is the same role with check valve.
② This valve enable to reverse flow by outside pilot pressure in case of
Free Flow Outlet
reverse free flow.
or
Poppet Reverse Free Flow Inlet
2) Operation
(B)
① It is the same as normal check valve in case of free flow. It flows from
chamber (A) to (B).
3) In case of reverse flow
(A)
① Oil doesn’t flow from chamber (B) to (A) usually.
Piston Free Flow Inlet ② When pilot pressure apply to chamber (C), poppet is pushed open by
or piston and piston rod, and reverse flow from chamber (B) to (A)
Reverse Free Flow Outlet become possible.
③ It shall be internal drain when chamber (A) side is connected to tank,
and external drain at not connected.
④ External drain (use drain port) has drain method select plug, and
(C) Pilot Port
internal drain doesn’t have.
RG - 06 -* (YUKEN)
P- 29
One Direction Throttle Valve
B
1) Intended Use
2) Operation
【 Free Flow 】
① When pressure flown from free flow in-port (A) become more that
spring power, sprue is pushed down and oil flow from (A) to (B).
Piston
【 Controlled Flow 】
In-Port (A)
① Hydraulic oil flown from controlled flow in-port (B) get in chamber
(C) and push up sprue with spring power.
② Sprue touches to flow volume adjusting handle via piston, oil flow
(b) Out-Port (B)
from space (b) to controlled flow out-port (B).
③ Space (b) increase by turning handle in clockwise direction and
flow volume also increase.
Sprue
(C)
P- 30
One Direction Throttle Valve A1
Throttle Valve
Hydraulic Indication Symbol
P1
T A P B
Bsol
T A P B
T A P B
P- 31
Solenoid Valve
P Drain
Dr
T
Sprue (1)
Push Pin
P
T
SOL b
A B
P
T
T A P B
SOL b
T A P B P- 33
Solenoid Valve (Wet Type Electromagnetic Change Valve)
A B A B
Close Center ● ●
Open Center
P T P T
T A P B T A P B
A B A B
AT Connecting ●
ABT Connecting
P T P T
T A P B T A P B
P- 34
Sprue Relationship Diagram (Neutral Position)
3 Position, Both Solenoid Spring Center (Sprue Type)
A B
Close Center
P T
A B
●
ABT Connecting
T A P B P T
T A P B
P- 35
Sprue Relationship Diagram (Neutral Position)
3 Position, Both Solenoid Spring Center (Sprue Type)
A B
AT Connecting
P T
A B
●
ABT Connecting
P T
with Throttle
T A P B
T A P B
P- 36
Solenoid Valve (3/8 Wet Type Electromagnetic Change Valve)
DSG - 03 - 3C4 -*- 5074 (YUKEN)
SOL b SOL a
A B
SOL a P T SOL b
Neutral
1) Intended Use
① Control direction of actuators by turning electricity
T A P B on solenoid coil and changing sprue.
2) Operation
① When SOL b is ON; sprue moves right by push pin,
oil flow from P to B, and cylinder moves backward.
Return oil of cylinder flow from A to T.
② When SOL b is OFF; sprue returns neutral position,
oil is blocked, and cylinder stops.
③ When SOL a is ON, the operation shall be opposite
to ①.
④ When SOL a is OFF, the operation shall be opposite
to ②.
P- 37
shuttleValve
The valve which opens and closes a Logic valve
T X AP Y
T T
Hydraulic
Indication Symbol shuttleValve
shuttleValve
X AP Y X Y
AP
A B A B
Logic Valve
Logic Valve
P T P T
B B
A A
P- 38
INJECTION VALVE DC - *** -
J Control flow volume and speed.
Logic Valve Flow free between A and B.
Pressure up timeValve
X X
B
Flow Adjustment Handle
A
E
B C2G15
Hydraulic Indication Symbol M
Pressure up time
Flow Volume
Logic Valve
X B
A X PISTON DG1 5
ACCUMULATOR E SSOL
A B
A P- 39
DC250C ~ DC800C valve inside
INJECTION VALVE DC - *** - C
L
(High speed) (Low speed)
PISTON
C2G11 ACCUMULATOR E C2G12
Low speed High speed
E E cover
M M
INJECTION
CYLINDER DC250CL ~ DC800CL valve inside
N11 ● ●
N12
L Accel H Accel
● ●
P T P T cover(2)
DG12
DG11
SISOL HISOL spring
cover(1) A
guide PCvalve
seat
O ring O ring backup ring
(C2G16)
P- 40
Flow Volume Adjusting Valve with
PQ Valve
Proportion Electromagnetic Relief Valve
① Proportion Electromagnetic
Flow Volume Adjusting Valve ③ Proportion Electromagnetic
Pressure Control Valve
③ ①
② Pilot Pressure ④ Main Relief Valve
⑤ Reducing Valve
②
⑥
④
⑥ Safety Valve
T P Y X
⑤ Check Valve
Pressure Switch
P FLT2
6228L/min C2G15
Close Open C2G16
T P
T Injection Cylinder
10m/s
Coil A
Sensor
3954L/min
Booster Cylinder
Servo Valve
(8451L/min)
Back Pressure
Remove Cylinder Meter Out Multi-Level Injection
T Speed Control Valve
Open Close
P- 42
Filter Element Change Procedure
Type of Servo Filter Electric Connect: (G-GF-A-06-3-8CH-EK)
(Small Size)
Type of Filter Element (inside): (P-G-GF-A-06-3-8CH)
Type of Filter Paper: Use both as Mineral Oil and Water-Glycol Flame
Retardant Hydraulic Oil
① Open pump OFF T18 stop valve and ② Remove M8 air release ③ Remove by wrench on h
drain hydraulic oil in PACC. assembly screw. exagon head under in
(Be careful not to forget close it.) dicator.
<Be careful not lose small ball
Take out whole filter case from machine. in the screw.>
<Note: If filter element removed with
pitting on machine, dust drop in hydra
ulic circuit.>
④ Remove cover. ⑤ Remove element and drain oil in filter. ⑥ Clean inside filter.
(Note: Don’t remove body.) (Wire mesh for early mold, paper for (Cleaning oil for mineral oil,
now: have mutuality) water for water-glycol)
Change the element new.
P- 43
Structure of Mold Close Structure of Injection
Cylinder Assembly Cylinder Assembly
M E
Space 0.2mm
P- 44
Structure of Ejector
Structure of Piston Accumulator
Cylinder Assembly
Cylinder Assembly
Piston
Piston Ring
Slipper Seal
P- 45
Source of Incursion/Occurring of Dust on Hydraulic Device
Dust Incursion
Wear Dust
Direction Valve Control Occur
Water Incursion
Wear Dust
Occur
Filter
Water Incursion
Wear Dust
Occur
Dust Incursion
Solid
Hydraulic Pump
Particle
PF1
M Additive ダ営技
Separate Out Depleted Product 05.04.01
New Oil 渡 辺
P- 46