You are on page 1of 2

CALCULATION FOR SIZING AN AXIALLY LOADED PIPE

Conditions: 1 H, Should be Greater Than ((D/2)+ Tinsulation) Thickness of Isulation, Tinsulation = 384.8 80 mm mm

Outer Diameter of SP Pipe, Do Design Load, W Span, L

518.7108 51.87108 1377 700

mm Cm Kg Cm 963900 Kg / Cm Cm Kg / Cm4 Cm4 Kg-Cm

Maximum Bending Moment, M = W x L Allowable Stress, f Section Modulus, Z Youngs Modulus, E Moment of Inertia, I Section Modulus, Z = M / f 537.1 76.2 800 31854.82

From IS : 800 From Table From Table

1794.6379 Cm

Select the Nearest Size OD from Pipe Data, Do = Section Modulus, Z = ( x (Do4 - Di4)) / (32 x Do) Do4 - Di4 = 649270.3 Cm4 Di4 = 938959.8 Cm4 Di = 31.12875 Cm Thickness of Support Pipe, Tn = (Do - Di) / 2 Tn = 2.185623 Cm = 21.85623 mm THUS THE SELECTED PIPE SIZE, Do Tn 355 21.856226

35.5

Cm

mm mm

INPUT

609.6 D (mm) 17.48 T (mm) 45

You might also like