You are on page 1of 1

SAMSUNG ENGINEERING CIVIL STR.

TEAM
FLARE BURNPIT AREA Revision: 00

WASIT GAS PLANT- WFC FACILITIES


AREA FLARE & BURNPIT AREA DWG NO. PO-XXXX-Q73-PP-0002

ITEM NO. EMBANKMENT ( SELECT FILL) JOB NO. PO-XXXX


REV. 3

EMBANKMENT FILL FOR FLARE STACK

3 EL. = +5.00m
0.150
1
0.150

Emb 1
Emb 2 Emb 2
EL. = +1.00m
SABKAH
GEOTEXTILE
SECTION

Marl
Compacted Base
Compacted Fill
Sabkah Soil

1.0 AREA
Embankment on Top Calculated in Autocad (see attached dwg.) = 122347.00 m2
Embankment on Slope Calculated in Autocad (see attached dwg.) = 86063.00 m2
TOTAL AREA = 208410.00 m2

2.0 EMBANKMENT (Selected Fill) Thk Area


Embankment 1 3.70 x 122347.00 = 452683.90 m3
Embankment 2 0.5 x 3.70 x 86063.00 = 159216.55 m3
TOTAL VOLUME = 611900.45 m3
TOTAL VOL. OF "TRANSVERED SOIL" = 154989.50 m3
Pipe Support Fdn Volume (from Arch Dept) = 1240.00 m3
TOTAL VOL. OF "IMPORTED SOIL" = 455670.95 m3

3.0 GEOTEXTILE
Area on Top = 122347.00 m2
Area on Slope = 86063.00 m2
TOTAL AREA = 208410.00 m2

4.0 DYNAMIC COMPACTION


Area = Calculated as per attached sheet = 71074.00 m2