Professional Documents
Culture Documents
Preboard 2 Sanitation Design PDF
Preboard 2 Sanitation Design PDF
d. 30,333
12. The speed at which an exact model of the pump
would have to run if it were designed to deliver 1
GPM against 1 feet head per stage
a.
Peripheral speed
b. Exact speed
c.
Transition speed
d. Same speed
13. A positive displacement pump is
a.
Rotary pump
b. Centrifugal pump
c.
Turbine pump
d. Piston pump
14. A pressure gage register 50 psig in a region where
barometer is 1.25 psia. Find the absolute pressure
a.
64.25 Kpa
b. 10.125 psi
c.
86.25 kpa
d. 64.25 psi
15. A pump used in underground
a.
Surface pump
b. Submersible pump
c.
Piston pump
d. Centrifugal pump
16. The property of a fluid whereby its own molecule
are united or attracted to each other is:
a.
Ideal fluid
b. Pilot tube
c.
Cohesion
d. Adhesion
17. A state of complete physical mental and social
well-being and not merely the absence of disease
or infirmity.
a.
Health
b. Vital statistics
c.
Fitness
d. Statics
18. Public health substance that deforms
continuously under the application of a shear
force. It cannot sustain a shear force at rest is:
a.
Fluid
b. Liquid form
c.
Flowing water
d. Discharge
19. Study of the distribution of the disease or
condition in a population
a.
Public health
b. Environmental Sanitation
c.
Epidemiology
d. Environmental health
20. The physical characteristics of sewage is
determined by:
a.
Turbidity
b. Colour
c.
Odour
d. All of the above
21. It includes the discharge from latrine, urinals,
bathrooms, kitchens and stables is called:
a.
Refuse
b. Wet refuse
c.
Sewage
d. Waste water
22. Used to deliver water at a point higher than the
position of the pump itself when the plunger
decends, the valve is closed and the water in the
cylinder is forced out through the valve and up to
the storage.
a.
Pumps
b. Force pump
c.
Lift pump
d. Suction pipe
23. Bacteria which has no function in sewage
treatment
a.
Non- aerobic bacteria
b. Pathogenic bacteria
c.
Facultative bacteria
d. Aerobic bacteria
d. floe
69. Which does not apply in the removal of
suspended materials and color in the water
supply?
a.
Sedimentation
b. Coagulation
c.
Filtration
d. Chlorination
70. The pipe or shaft which is used to remove foul or
congested air from a fixture or a room and convey
the same to the atmosphere is called _______
a.
Local vent
b. Crown vent
c.
Back vent
d. Venting pipe
71. What is the process of water supply purification
which consists of applying certain chemicals in
particles too small to be removed by plain
sedimentation?
a.
Coagulation
b. Sedimentation
c.
Filtration
d. Screening
72. What is the type of water closet prescribed for
public toilet?
a.
Elongated bowl type
b. Oval bowl type
c.
Circular bowl type
d. Egg shaped bowl type
73. What is the process of exposing water in their
films to the oxygen of the atmosphere in order to
remove neutralize the taste, odor and dissolved
oxygen?
a.
Filtration
b. Screening
c.
Aeration
d. Sedimentation
74. What is the pipe fitting with outside thread and
projecting square head used for closing the edge
of another fitting?
a.
Plug
b. Cap
c.
Knot
d. Bushing
75. The jelly like substance being formed in the
process of coagulation?
a.
Scum
b. Sledge
c.
Floe
d. alum
76. The handicapped fixtures are usually designed for
people with less physical ability that the general
public. For the handicapped, what is the
prescribed height of the toilet bowl?
a.
450 mm
b. 400 mm
c.
500 mm
d. 600 mm
77. What are the used disinfections large public
water supplies?
a.
Ultraviolet rays
b. Ozone
c.
Floe
d. Chlorine
78. The difference between a tube and a pipe is that
the tube has relatively thin wall and ____.
a.
Straight edge
b. The listed size correspond to the outside
diameter
c.
Relatively square edge
d. The listed size correspond to the inside
diameter.
79. What is the important advantage of chlorine
compared to other water supply treatment?
a.
Control the growth of algae
b. Effective in the coagulation process
c.
Control taste and odor
d. Kills bacteria
80. What is the prescribed distance of vent from trap
seal in plumbing installation?
a.
1.5 m
b. 0.6 m
c.
2m
d. 1 m
81. What is that vent pipe system on plumbing which
liquid waste flow through?
a.
Wet vent
b. Yoke vent
c.
Stack vent
d. Back vent
82. The classification of water when it contains
dissolved salts of calcium and magnesium?
a.
Soft
b. Hard
c.
Balanced
d. Neutral
83. What is that vent pipe in plumbing that serve the
building drain and building sewer?
a.
VSTR
b. SVTR
c.
Yoke vent
d. Relief vent
84. What is that receptacle attached to the plumbing
system other than trap on which water or waste
may be collected or retained for ultimate
discharge into the drainage?
a.
Catch basin
b. Manhole
c.
Bleeder
d. Scupper drain
85. How is water hardness measured?
a.
Ounce of hardness
b. Grains per gallon
c.
Parts per million
d. Soap suds
86. What is the pipe connection in which a ball is held
in a cup-like that allows movement in every
direction?
a.
Universal joint
b. Uniform patent
c.
Ball joint
d. Caulk joint
87. What is the good reason why hardness in water is
objectionable?
a.
Dangerous to health
b. Nuisance in household operation
c.
Water using equipment cannot operate
d. Scaling of boilers
88. Leaching field is categorized as one of the on-site
efferent disposal for septic tank. How far should
be the distance from a shallow well to prevent
contamination of water?
a.
25 m
b. 50 m
c.
15 m
d. 40 m
89. What do you call that process of removing the
hardness causing minerals from water?
a.
Water softening
b. Hardness removal
c.
Demineralization
d. Dehardinization
90. In plumbing, the unobstructed vertical distance
through the free atmosphere, between faucet
supplying water and the flood level rim of a
fixture is called ______
a.
Air gap
b. Airline
c.
Flushing lane
d. Goose neck
91. What is the minimum capacity of the water tank
needed for a complete water closet flushing in a
toilet?
a.
19 L
92.
93.
94.
95.
96.
97.
98.
99.
100.
b. 26 L
c.
15 L
d. 12 L
What is vertical distance between the dip and
crown weir of the trap?
a.
Trap seal
b. Crown air
c.
Leader
d. Bleeder
What is that fittings so installed in plumbing
system to prevent passage of air, gas and some
vermin through the pipe?
a.
Trap
b. Check valve
c.
Flap valve
d. Gate valve
What is the type of wrench used in working with
plated finish and in place with too small to admit
pipe wrench?
a.
Strap wrench
b. Closed wrench
c.
Open wrench
d. Pipe tong
What is that fitting that operates automatically
when refilling the water tank after each discharge
and shutting off completely when the tank is
already full?
a.
Float valve
b. Foot valve
c.
Pressure regulating Valve
d. Check valve
An oil tank is 3m long, 3 m wide and 2 m high,
when it is full of coconut oil specific gravity of
0.90, find the downward force at the bottom of
the tank.
a.
16,300 kg
b. 16,200 kg
c.
15,200 kg
d. 14,200 kg
A swimming pool is 6m wide by 12m long, if is
1.20 m deep in one end and 2.40 at the other
end. How many gallon of water does it contain?
a.
34,140 gal
b. 34,240 gal
c.
33,240 gal
d. 34,250 gal
A rectangular ground reservoir is to be
constructed to serve the water supply
requirement for a commercial building the
outside dimension of the reservoir is 8m long, 6m
wide and 8m deep. Compute for the total cost of
excavation if the cost of labor is P50.00 per cubic
meter.
a.
P1,920
b. P19,200
c.
P18,200
d. P1,820
Master Plumber A can finish the excavation and
pipe laying of storm drainage in 8 hrs, Master
Plumber B require 10 hrs to do same job. How
many hours are required if both A &B work
together?
a.
4.24 hrs
b. 3.24 hrs
c.
5 hrs
d. 3.5 hrs
A plumber is to use a deep well as source of water
to supply for the building under construction and
he want to estimate the length of intake pipe, so,
from the surface of the ground he drop a coin
into the well and after 2 seconds he heard the
splashing sound down under, how deep is the
well?
a.
32.2 ft
b. 64 ft
c.
22.2 ft
d. 33 ft
113.
114.
115.
116.
117.
118.
119.
120.
121.
122.
123.
124.
d. S-trap
138. It is the pipe extension of a solid or waste stack
above the highest horizontal drain connected to
the stack:
a.
Vent stack thru roof
b. Stack vent thru roof
c.
Local vent
d. Loop vent
139. It is the arrangement of venting so installed that
one vent will serve two traps?
a.
Local vent
b. Unit vent
c.
Wet vent
d. Relief vent
140. It is pipe which convey only liquid waste free from
fecal matter
a.
Back vent
b. Loop vent
c.
Wet vent
d. Yoke vent
141. It is a portion of the vent pipe through which
liquid waste flow:
a.
Local vent
b. Utility vent
c.
Individual vent
d. Relief vent
142. It is a loss of trap seal due to unequal atmospheric
pressure condition and due to rapid flows of
water thru the trap:
a.
Wind effect
b. Capillary attraction
c.
Siphonage
d. Back pressure
143. It is a loss of trap seal due to suspension of
foreign object such as string rugs or lint into the
trap seal extending over the outlet arm of the
trap:
a.
Wind effect
b. Evaporation
c.
Capillary attraction
d. Siphonage
144. The top cover and the manhole of a septic tank
usually extended above the surface of the ground
to overcome surface water infiltration
a.
15 cm
b. 10 cm
c.
5 cm
d. 20 cm
145. It is a compartment in the septic tank for the
settlement of floating or suspended matters, sand
debris and any excessive amount of grease or oil
from sewage:
a.
Bathing chamber
b. Sedimentation chamber
c.
Chlorination chamber
d. Sewage chamber
146. A septic tank is water tight receptacle for which
sewage is digested than a biological action mainly
by microorganism such as
a.
Facultative bacteria
b. Aerobic bacteria
c.
Anaerobic bacteria
d. Enzymes
147. The retention period or the time for which
suspended matters in septic tank would settle
and stabilize is:
a.
24 hrs
b. 12 hrs
c.
18 hrs
d. 30 hrs
148. The soil branch must be slope at a grade so that
waste content is given a flow of pipe velocity to
assure a self-scouring condition and lessen the
possibility of seal loss stoppage and retarded
flow:
a.
inch per foot
b. inch per foot
149.
150.
151.
152.
153.
154.
155.
156.
157.
158.
159.
160.
c.
1/8 inch per foot
d. 1 inch per foot
The cold-water supply is delivered into the hot
water-tank by means of a boiler tube; this tube
has a hole within 6 inches from the top of the
tank, the purpose of which is to serve as:
a.
Vacuum breaker
b. Ventilation
c.
Inspection hole
d. Blow-off
What vent pipe installation in the building which
has no connection whatsoever with the plumbing
fixture
a.
Bleeder pipe
b. Ventilating pipe
c.
Side vent
d. Exhaust pipe
Water closets shall be computed as ____fixture
units when determining septic tank size
a.
4
b. 5
c.
6
d. 8
Galvanized wrought iron or galvanized steel pipe
shall not be used underground and shall be kept
at least ____ above ground.
a.
200 mm
b. 312 mm
c.
152 mm
d. 225 mm
One fixture unit is equivalent to
a.
30 lit/min
b. 1 cu.m./ min
c.
1 cu.ft./min
d. 25 lit/min
For assembly places for public use, how many
water closets are required if the capacity is 115
males?
a.
4
b. 3
c.
2
d. 5
In above scenario, how many urinals are
required?
a.
4
b. 3
c.
2
d. 5
There shall be a minimum of ______drinking
fountains per occupied floor in schools, theater,
auditoriums, dormitories, offices or public
building
a.
1
b. 2
c.
3
d. 4
Drains in gutters in public shower rooms shall be
spaced not more than___ apart
a.
3.50 m
b. 4.50 m
c.
3.90 m
d. 4.90 m
All shower compartments shall have a minimum
finished interior area ______sq.m
a.
0.60 sq. m
b. 0.75 sq. m
c.
0.80 sq. m
d. 1.00 sq. m
Cast iron fitting up to and including 51mm in size,
when used in connection with potable water
piping shall be_____
a.
Welded
b. Soldered
c.
Galvanized
d. Anodized
Water pipes shall laid a minimum of ______
above the sewer or drainpipe
161.
162.
163.
164.
165.
166.
167.
168.
169.
170.
171.
172.
a.
0.25 mm
b. 0.30 mm
c.
0.40 mm
d. 1 ft
No building water service pipe shall be less than
_____in diameter
a.
19 mm
b. 25 mm
c.
1 inch
d. inch
Shower head used in private has ___water supply
fixture unit
a.
1
b. 2.5
c.
3
d. 2
Clean-outs shall be provided at every ____ length
or a fraction thereof
a.
15 m
b. 10 m
c.
20 m
d. 18 m
Clean-out may be omitted on a horizontal drain
line less than ____in length
a.
2.0 m
b. 1.80 m
c.
1.50 m
d. 2.5 m
The minimum slope required for 102 mm
diameter pipe or larger drainage piping
a.
1%
b. 2 %
c.
1.5 %
d. None of these
Vent opening shall terminate not less than ____
from any window, door or any opening
a.
1.0 m
b. 0.90 m
c.
3.0 m
d. 0.30 m
In hospital wards, 1 bath tub or shower shall be
provided per ____
a.
10 patients
b. 15 patients
c.
20 patients
d. 30 patients
Lavatories not affected by side walls, with
effective opening not greater than 13 mm dia.
Has minimum air gap of _____
a.
25 mmm
b. inch
c.
38 mm
d. 2 inch
Water supply wells shall be located at least
_______ from building sewer
a.
10.00 m
b. 12.00 m
c.
15.20 m
d. 20.50 m
Gate valve used in drainage work having a 102
mm diameter or larger shall have ____bodies
a.
Cast iron
b. Cast brass
c.
Bronze
d. Galvanized iron
Manhole in septic tank shall be provided with
minimum dimension of _____
a.
600 mm
b. 508 mm
c.
400 mm
d. 458 mm
Roof deck strainers shall have a total net inlet
area less than ______ times the area of the outlet
pipe to which the drain is connected.
a.
One and one-half
b. Two
c.
Three
c.
d.
c.
d.
183. Plumbing symbol for point of connect
a.
.
b.
c.
d.
184. Plumbing symbol for service sink
a.
.
b.
c.
d.
c.
d.
c.
d.
186. Plumbing symbol for bushing (welded)
a.
.
b.
c.
d.
187. Plumbing symbol for stop cock (screwed)
a.
.
b.
.
.
b.
c.
c.
d.
d.
b.
c.
d.
c.
d.
c.
d.
d. Lead pipe
191. A small concrete receptacle between the septic
tank and the drain field in which lines of drain
tiles extends and which acts as surge tank to
distribute the flow of sewage equally to each line
of drain tiles
a.
Distribution box
b. Digestive cesspool
c.
Domestic sewage
d. Drainage system
192. The least expensive but the noisiest water closet;
only small amount of standing water-susceptible
to fouling, staining and contamination.
a.
Siphon jet
b. Siphon vortex
c.
Siphon washdown
d. Reverse trap
193. A plumbing fixture used for washing the middle
part of the body, especially genitals. It is also
known as the Sitz Bath.
a.
Bidet
b. Lavatory
c.
Water closet
d. Urinal
194. Minimum trap diameter for laundry tub
a.
38 mm
b. 32 mm
c.
51 mm
d. 72 mm
195. It is considered to be the most quiet, most
efficient and most sanitary water closet.
a.
Siphon jet
b. Siphon vortex
c.
Reverse trap
d. Siphon washdown
196. Minimum trap diameter for shower bath
a.
38 mm
b. 32 mm
c.
76 mm
d. 51 mm
197. A receptacle attached to a plumbing system other
than a trap in which water or waste may be
collected for ultimate discharge into the plumbing
system
a.
Water closet
b. Fixture
c.
Drainage system
d. Storm drainage
198. Each shower receptor shall be constructed to
have a finished dam, curb or threshold of at least
_____ mm lower that the outside floor.
a.
25.4 mm
b. 52.4 mm
c.
24.5 mm
d. 54.2 mm
199. A plumbing fixture usually located in the
operating room in a hospital to enable personnel
to scrub their hands prior to a surgical procedure;
the hot and cold water supply is activated by a
knee-action mixing valve or by wrist or pedal
control.
a.
Slop sink
b. Scrub sink
c.
Shower bath
d. Laundry tub
200. This is less esthetic than aeration but more
certain oxidation process. It is commolly used in
cooling lower treatment and in addition
ozonation has very wide range of treatment
application
a.
Coagulation
b. Filtration
c.
Disinfection
d. Ozonation
201. A pipe within the structure or on the premises
which conveys water from the water service pipe
or meter to the point of utilization
202.
203.
204.
205.
a.
Water distribution pipe
b. Water pipe
c.
Riser
d. Water service pipe
What is the size of downspout if the rainfall
intensity is 100 mm (4) on a 1200 m2 deck roof
a.
75 mm
b. 100 mm
c.
200 mm
d. 150 mm
What is the size of horizontal rainwater pipe with
2% slope if the max. rainfall is 100 mm on a 206
m2
a.
250 mm
b. 100 mm
c.
300 mm
d. 375 mm
How many lavatory shall be installed in a school
with 240 male students
a.
6
b. 3
c.
5
d. 4
What is the size of downspout if the rainfall
intensity is 100 mm (4) if the deck roof is 435
mm2
a.
50 mm
b. 150 mm
c.
75 mm
d. 100 mm
a.
b.
c.
d.
214.
Inches/ hr
Inches/ min
Inches/ sec
Inches/ day