Diagnosis plug Flash code:

Display activation and operation: The DTCs have an “FMI” value. This
To use the display to show DTCs, the control switch must indicates the fault type on the basis of the
be used. following schedule:
There are four buttons on the control switch which are used
to browse through the menus: FMI:
1. " Esc " Used to return to the previous menu or to 0. Value too high: Data is
interrupt an operation acceptable, but is above the normal working
2. " Select " Confirms a highlighted menu selection range
3. " + " Moves the cursor up 1. Value too low: Data is
4. " - " Moves the cursor down acceptable, but is below the normal working
range
2. Incorrect data: Varying or
incorrect data:
3. Electrical fault: Abnormally high
voltage, or short-circuit to higher voltage
4. Electrical fault: Abnormally low
voltage, or short-circuit to lower voltage
5. Electrical fault: Abnormally low
current, or broken connection
6. Electrical fault: Abnormally high
current, or short-circuit
7. Mechanical fault: Faulty response
from mechanical system
8: Mech. or el. fault: Abnormal
frequency
9: Communication fault: Abnormal
update rate
10: Mech. or el. fault: Abnormally
large variations
11: Unknown fault: Unidentifiable
fault
12: Component fault: Faulty unit or
component
13: Incorrect calibration: Calibration
value outside limits