Model TA2 2x R2

Descripción del dispositivo


Dispositivo Model TA2 2x R2
Fabricante Magnetrol
Versión 1.4.164.132 / 2016-08-16
Descripción Flow
Clasificación flow

Parámetros del dispositivo


Lista de
Nombre Valor Estado Descripción Alcance
unidades
Online Parameterize
PV Flow 6870 [ SCFM ] ok MM SCFD
- Million
standard
cubic feet
per day.
MSCFD -
Thousand
standard
cubic feet
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -
Normal
cubic
meters per
day.
Nm3/h -
Normal

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 2 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

PV Loop 14.99 [ mA ] ok Analog Output


Value- Value that
tracks the Digital
Value
representation,
under normal
operating modes.
PV % Range 68.70 [ % ] ok
SV Process 28.87 [ °C ] ok °C -
Temperature Degrees
Celsius
°F -
Degrees
Fahrenheit

SV Loop 6.31 [ mA ] ok Analog Output


Value- Value that
tracks the Digital
Value
representation,
under normal
operating modes.
SV % Range 14.42 [ % ] ok
Device Setup
Basic Configuration

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 3 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
System Units
Flow Units SCFM ok Flow Units -
Select the units of
measurement for
the mass
volumetric flow
rate.
Mass Units lbs/H ok Mass Units -
Select units of
measurement.
Temperature °C ok Temperature
Units Units - Select
units of
measurement for
temperature.
Density Units lb/ft3 ok Density Units -
Select units of
measurement for
density at STP or
Normal
conditions.
Totalizer Units SCF ok Totalizer Units -
Select units of
measurements
used by the
Totalizer.
Diameter Units inches ok Diameter Units -
Select the desired
units of
measurement for
the inside
diameter of a
circular pipe or
duct.
Area Units ft2 ok Area Units -
Select units of
measurement used
for the flow area
of the pipe or
duct.
Flow Area
Pipe ID 11.9380 [ inches ] ok Pipe Inside inches -
Diameter - The feet -
flow area must be meters -
entered. This is mm -

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 4 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
done by either
entering the inside
diameter of a pipe
or the cross
sectional area of
the pipe or duct.
Flow Area 0.7773 [ ft2 ] ok Flow Area - The in2 -
flow area must be Square
entered. This is inches.
done by either ft2 - Square
entering the inside feet.
diameter of a pipe m2 -
or the cross Square
sectional area of meters.
the pipe or duct. mm2 -
Square
millimeters.

I/O Configuration
Damping 4[s] ok Damping - Adds
additional time
delay to the TA2.
Enter value as a
time constant
from 0 to 15
seconds.
A01 Loop Config
PV is Flow ok Primary Index
into Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the
Primary Variable
dynamic variable.
PV Lwr Range 0.00 [ SCFM ] ok PV Lwr Range MM SCFD
Val Val - Enter the 4 - Million
mA point using standard
the units of cubic feet
measurement per day.
previously MSCFD -
selected Thousand
standard
cubic feet

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 5 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -
Normal
cubic
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

PV Upr Range 10000.00 [ SCFM ] ok PV Upr Range MM SCFD


Val Val - Enter the 20 - Million
mA point using standard
the units of cubic feet
measurement per day.
previously MSCFD -
selected. Thousand
standard

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 6 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
cubic feet
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -
Normal
cubic
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

Fault State 22mA ok Fault State -


Select how the
Analog output of
the TA2 will
respond if a fault
in the instrument
is detected.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 7 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Variable Mapping
SV is Process Temperature ok Secondary Index
into Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the
Secondary
Variable dynamic
variable.
TV is Mass ok Tertiary Index
into Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the
Tertiary Variable
dynamic variable.
QV is R Totalizer ok Fourth Index into
Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the
Fourth Variable
dynamic variable.
Totalizers
Totalizer Units SCF ok Totalizer Units -
Select units of
measurements
used by the
Totalizer.
R Totalizer Mode Enabled ok Mode - Enable or
Disable the
totalizer
operation.
R Totalizer Mult 1 ok Multiplier for the

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 8 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
resettable
totalizer. For
example, an
accumulated value
of 1,000 will
display as 10 if
the multiplier is
set to 100.
R Totalizer Flow 6124540 [ SCF ] ok Total flow SCF -
measured by this Standard
unit since the cubic feet.
totalizer was last Nm3 -
reset. Normal
cubic
meters.
Nl -
Normal
liters.
lbs -
Pounds
kg -
Kilograms

R Totalizer Time 6385.08 [ h ] ok Total time, since


the totalizer was
reset, over which
the total flow
occurred.
NR Totalizer 1,000 ok Multiplier for the
Mult non-resettable
totalizer. For
example, an
accumulated value
of 1,000 will
display as 10 if
the multiplier is
set to 100.
NR Totalizer 386125 [ SCF ] ok Non-resettable SCF -
Flow value representing Standard
the total flow cubic feet.
measured by the Nm3 -
unit. Normal
cubic
meters.
Nl -
Normal
liters.
lbs -

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 9 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Pounds
kg -
Kilograms

NR Totalizer 6385.08 [ h ] ok Total time over


Time which the total
flow occurred.
Note that rollover
to zero time will
occur when the
total time exceeds
11.4 years.
Advanced Configuration
Gas Cal Table Table A ok Gas Calibration
Table - Which
stored calibration
table to use for
computing gas
flow.
Auto Switching Disabled error Enable or Disable
the auto switching
operation.
New User 59136 ok User password
Password required to change
parameter settings
from keypad.
Install Factors
A 0.00 [ SCFM ] ok Install Factors - A, MM SCFD
B, C; Install - Million
Factors are standard
utilized in cubic feet
situations when per day.
the measured flow MSCFD -
rate may need to Thousand
be adjusted due to standard
variations in flow cubic feet
profile or other per day.
installation SCFD -
factors. The Standard
Install Factors are cubic feet
the coefficients of per day.
the polynomial SCFH -
equation: Standard
Corrected Flow = cubic feet
A + Bx + Cx^2 per hour.
where x is the SCFM -

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 10 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
flow measured by Standard
the TA2 in PV cubic feet
units. per minute.
Nm3/d -
Normal
cubic
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

B 1.000000 ok Install Factors - A,


B, C; Install
Factors are
utilized in
situations when
the measured flow
rate may need to
be adjusted due to
variations in flow
profile or other
installation
factors. The
Install Factors are
the coefficients of
the polynomial
equation:
Corrected Flow =
A + Bx + Cx^2

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 11 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
where x is the
flow measured by
the TA2 in PV
units.
C 0.000000 ok Install Factors - A,
B, C; Install
Factors are
utilized in
situations when
the measured flow
rate may need to
be adjusted due to
variations in flow
profile or other
installation
factors. The
Install Factors are
the coefficients of
the polynomial
equation:
Corrected Flow =
A + Bx + Cx^2
where x is the
flow measured by
the TA2 in PV
units.
STP Conditions
STP Temperature 21.11 [ °C ] ok STP Temperature °C -
- permit the user Degrees
to modify STP Celsius
conditions to °F -
application Degrees
specific Fahrenheit
requirements.
Enter temperature
used for Standard
Temperature.
STP Pressure 1 Atmosphere ok STP Pressure -
Permits the user to
modify STP
conditions to
application
specific
requirements.
Select Standard
Pressure of 1
atmosphere (14.7
psia) or 1 bar

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 12 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
(14.5 psia).
Custom Unit
Custom Unit Text Custom ok Text describing
the units for the
custom unit
output.
Custom Unit Mult 0.000000 ok Multiplier used to
calculate the
custom unit
output. The
multiplier is
applied based on
the PV.
Device Information
Local Tag MAGNETROL TA2 ok Text describing
the local tag
designation for the
unit.
Descriptor ???????????????? ok Descriptor- Text
that is associated
with the Field
Device. This text
can be used by the
user in any way.
There is no
specific
recommended use.
HART Tag TA2 ok Tag- Text that is
associated with
the Field Device
installation. This
text can be used
by the user in any
way. A
recommended use
is as a unique
label to a plant
that correlates to a
Field Device
label: a plant
drawing, or on a
Control System.
This variable is
also used as a type
of data link layer
address handle.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 13 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Date 01/01/2001 ok Date- Gregorian
calendar date that
is stored in the
Field Device. This
date can be used
by the user in any
way. There is no
specific
recommended use.
Message ???????????????????????????????? ok Message- Text
that is associated
with the Field
Device. This text
can be used by the
user in any way.
There is no
recommended use.
Date/Time/Initials ???????????????? ok Date/Time/Initials
- When and by
whom the
configuration was
performed.
Manufacturer MAGNETROL ok Manufacturer
Identification
Code- References
a specific
manufacturer,
which is usually a
company name,
that is responsible
for the
manufacture of
this Field Device.
Model Number Model TA2 2.x ok Model-
References the
type of Field
Device, usually an
advertised model
number, that is
unique to a single
manufacturer.
Specific Model TA2-A1 ok Select the
appropriate TA2
model.
Firmware Version Ver 2.0f Model TA2 HT ok Firmware Version
- Provides the
version and date

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 14 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
of the Firmware
used by the TA2.
Magnetrol S/N 71697101001 ok Magnetrol S/N -
Serial number of
this unit.
Device ID 8057033 ok Field Device
Identification-
Uniquely
identifies the Field
Device when
combined with the
Manufacturer
Identification and
Device Type.
Therefore, this
variable cannot be
modified by the
Host user.
Final asmbly num 0 ok Final Assembly
Number- Number
that is used for
identification
purposes, and is
associated with
the overall Field
Device.
Factory Configuration
Enter Password 0 ok Password is
required to change
calibration factors.
NSP Value 59136 ok Enter new value
when directed by
Magnetrol.
Probe Parameters
Sensor Type TXR ok Sensor Type -
Type of sensor
used for probe
calibration at
factory.
To 45933112 ok To - Probe
calibration factor.
Fo 27724 ok Fo - Probe
calibration factor.
RTD Calibration OK ok The status of the

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 15 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
RTD calibration
stored in the
device.
Control Parameters
Coeff Ratio 20.000000 ok Coeff Ratio
Slope 5.000000 ok Slope - Factory
calibration
parameter.
Power Predictor 30.000000 ok Power Predictor -
Factory
calibration
parameter.
Factory 1.000000 ok Factory Parameter
Parameter 1 1 - Factory
calibration
parameter.
Factory 0.000000 ok Factory Parameter
Parameter 2 2 - Factory
calibration
parameter.
Factory 0.000000 ok Factory Parameter
Parameter 3 3 - Factory
calibration
parameter.
Factory 0.000000 ok Factory Parameter
Parameter 4 4 - Factory
calibration
parameter.
Factory 0.000000 ok Factory Parameter
Parameter 5 5 - Factory
calibration
parameter.
Module Parameters
Heater OK ok The status of the
Calibration heater calibration
stored in the
device.
Cal Parameters A
Set Point 5.77 [ °C ] ok Set Point -
Factory
calibration
parameter.
Zero Flow Signal 71.3 [ mW ] ok Zero Flow Signal

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 16 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
- value which
represents the
signal at zero
flow.
Low Flow Cutoff 45.87 [ SCFM ] ok Low Flow Cutoff
- primary variable
reading below
which the
indicated value
will be forced to
zero. This is
useful if a non-
zero PV is
indicated when a
no flow condition
exists.
Cal Pipe Area 0.01543 [ ft2 ] ok Cal Pipe Inside in2 -
Area - The inside Square
area of the pipe inches.
used during ft2 - Square
calibration. feet.
m2 -
Square
meters.
mm2 -
Square
millimeters.

Cal Table A
Table Length 30 ok Number of valid
power-flow pairs
in the calibration
table. A power-
flow pair is valid
if both values are
greater than all
preceding power-
flow pairs.
Pt 01 Power 71.3 [ mW ] ok Calibration table
power entry
corresponding to
Pt 01 Vel.
Pt 02 Power 100.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 02 Vel.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 17 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Pt 03 Power 166.9 [ mW ] ok Calibration table
power entry
corresponding to
Pt 03 Vel.
Pt 04 Power 201.1 [ mW ] ok Calibration table
power entry
corresponding to
Pt 04 Vel.
Pt 05 Power 230.3 [ mW ] ok Calibration table
power entry
corresponding to
Pt 05 Vel.
Pt 06 Power 258.4 [ mW ] ok Calibration table
power entry
corresponding to
Pt 06 Vel.
Pt 07 Power 283.1 [ mW ] ok Calibration table
power entry
corresponding to
Pt 07 Vel.
Pt 08 Power 307.5 [ mW ] ok Calibration table
power entry
corresponding to
Pt 08 Vel.
Pt 09 Power 326.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 09 Vel.
Pt 10 Power 349.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 10 Vel.
Pt 11 Power 370.6 [ mW ] ok Calibration table
power entry
corresponding to
Pt 11 Vel.
Pt 12 Power 391.6 [ mW ] ok Calibration table
power entry
corresponding to
Pt 12 Vel.
Pt 13 Power 412.5 [ mW ] ok Calibration table
power entry
corresponding to
Pt 13 Vel.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 18 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Pt 14 Power 434.7 [ mW ] ok Calibration table
power entry
corresponding to
Pt 14 Vel.
Pt 15 Power 457.3 [ mW ] ok Calibration table
power entry
corresponding to
Pt 15 Vel.
Pt 16 Power 479.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 16 Vel.
Pt 17 Power 500.4 [ mW ] ok Calibration table
power entry
corresponding to
Pt 17 Vel.
Pt 18 Power 520.9 [ mW ] ok Calibration table
power entry
corresponding to
Pt 18 Vel.
Pt 19 Power 542.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 19 Vel.
Pt 20 Power 562.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 20 Vel.
Pt 21 Power 586.9 [ mW ] ok Calibration table
power entry
corresponding to
Pt 21 Vel.
Pt 22 Power 609.7 [ mW ] ok Calibration table
power entry
corresponding to
Pt 22 Vel.
Pt 23 Power 635.5 [ mW ] ok Calibration table
power entry
corresponding to
Pt 23 Vel.
Pt 24 Power 654.9 [ mW ] ok Calibration table
power entry
corresponding to
Pt 24 Vel.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 19 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Pt 25 Power 681.6 [ mW ] ok Calibration table
power entry
corresponding to
Pt 25 Vel.
Pt 26 Power 708.2 [ mW ] ok Calibration table
power entry
corresponding to
Pt 26 Vel.
Pt 27 Power 736.1 [ mW ] ok Calibration table
power entry
corresponding to
Pt 27 Vel.
Pt 28 Power 771.3 [ mW ] ok Calibration table
power entry
corresponding to
Pt 28 Vel.
Pt 29 Power 797.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 29 Vel.
Pt 30 Power 876.5 [ mW ] ok Calibration table
power entry
corresponding to
Pt 30 Vel.
Pt 01 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 01 Power.
Pt 02 Vel 39 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 02 Power.
Pt 03 Vel 329 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 03 Power.
Pt 04 Vel 636 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 04 Power.
Pt 05 Vel 952 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 05 Power.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 20 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Pt 06 Vel 1317 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 06 Power.
Pt 07 Vel 1704 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 07 Power.
Pt 08 Vel 2123 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 08 Power.
Pt 09 Vel 2562 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 09 Power.
Pt 10 Vel 3049 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 10 Power.
Pt 11 Vel 3552 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 11 Power.
Pt 12 Vel 4082 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 12 Power.
Pt 13 Vel 4641 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 13 Power.
Pt 14 Vel 5266 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 14 Power.
Pt 15 Vel 5936 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 15 Power.
Pt 16 Vel 6626 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 16 Power.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 21 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Pt 17 Vel 7383 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 17 Power.
Pt 18 Vel 8152 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 18 Power.
Pt 19 Vel 9010 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 19 Power.
Pt 20 Vel 9735 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 20 Power.
Pt 21 Vel 10902 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 21 Power.
Pt 22 Vel 11953 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 22 Power.
Pt 23 Vel 13077 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 23 Power.
Pt 24 Vel 14305 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 24 Power.
Pt 25 Vel 15620 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 25 Power.
Pt 26 Vel 16979 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 26 Power.
Pt 27 Vel 18439 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 27 Power.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 22 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Pt 28 Vel 20288 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 28 Power.
Pt 29 Vel 21716 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 29 Power.
Pt 30 Vel 26039 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 30 Power.
Gas Parameters
TCC-A 0.962170 ok TCC-A -
Calibration factor.
TCC-B 1.637100 ok TCC-B -
Calibration factor.
TCC-C -1.190600 ok TCC-C -
Calibration factor.
Gas Density 0.074293 [ lb/ft3 ] ok Density - Gas lb/ft3 -
density at user Pounds Per
STP conditions. Cubic Foot
kg/m3 -
Kilograms
Per Cubic
Meter

Air Equivalency
Air Equivalence Disabled ok Air Equivalence -
When enabled,
uses polynomial
formula to convert
an air calibration
into equivalent
gas calibration
when computing
gas flow.
Ag 0.000000E+00 ok Ag - Calibration
factor.
Bg 1.000000E+00 ok Bg - Calibration
factor.
Cg 0.000000E+00 ok Cg - Calibration
factor.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 23 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Dg 0.000000E+00 ok Dg - Calibration
factor.
Eg 0.000000E+00 ok Eg - Calibration
factor.
Cal Parameters B
Set Point 12.00 [ °C ] ok Set Point -
Factory
calibration
parameter.
Zero Flow Signal 50.0 [ mW ] ok Zero Flow Signal
- value which
represents the
signal at zero
flow.
Low Flow Cutoff 1260.00 [ SCFM ] ok Low Flow Cutoff
- primary variable
reading below
which the
indicated value
will be forced to
zero. This is
useful if a non-
zero PV is
indicated when a
no flow condition
exists.
Cal Pipe Area 0.01543 [ ft2 ] ok Cal Pipe Area in2 -
Square
inches.
ft2 - Square
feet.
m2 -
Square
meters.
mm2 -
Square
millimeters.

Cal Table B
Table Length 1 ok Number of valid
power-flow pairs
in the calibration
table. A power-
flow pair is valid
if both values are
greater than all

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 24 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
preceding power-
flow pairs.
Pt 01 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 01 Vel.
Pt 02 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 02 Vel.
Pt 03 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 03 Vel.
Pt 04 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 04 Vel.
Pt 05 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 05 Vel.
Pt 06 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 06 Vel.
Pt 07 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 07 Vel.
Pt 08 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 08 Vel.
Pt 09 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 09 Vel.
Pt 10 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 10 Vel.
Pt 11 Power 0.0 [ mW ] ok Calibration table
power entry

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 25 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
corresponding to
Pt 11 Vel.
Pt 12 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 12 Vel.
Pt 13 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 13 Vel.
Pt 14 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 14 Vel.
Pt 15 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 15 Vel.
Pt 16 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 16 Vel.
Pt 17 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 17 Vel.
Pt 18 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 18 Vel.
Pt 19 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 19 Vel.
Pt 20 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 20 Vel.
Pt 21 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 21 Vel.
Pt 22 Power 0.0 [ mW ] ok Calibration table
power entry

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 26 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
corresponding to
Pt 22 Vel.
Pt 23 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 23 Vel.
Pt 24 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 24 Vel.
Pt 25 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 25 Vel.
Pt 26 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 26 Vel.
Pt 27 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 27 Vel.
Pt 28 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 28 Vel.
Pt 29 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 29 Vel.
Pt 30 Power 0.0 [ mW ] ok Calibration table
power entry
corresponding to
Pt 30 Vel.
Pt 01 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 01 Power.
Pt 02 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 02 Power.
Pt 03 Vel 0 [ SFPM ] ok Calibration table
flow entry

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 27 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
corresponding to
Pt 03 Power.
Pt 04 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 04 Power.
Pt 05 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 05 Power.
Pt 06 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 06 Power.
Pt 07 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 07 Power.
Pt 08 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 08 Power.
Pt 09 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 09 Power.
Pt 10 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 10 Power.
Pt 11 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 11 Power.
Pt 12 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 12 Power.
Pt 13 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 13 Power.
Pt 14 Vel 0 [ SFPM ] ok Calibration table
flow entry

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 28 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
corresponding to
Pt 14 Power.
Pt 15 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 15 Power.
Pt 16 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 16 Power.
Pt 17 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 17 Power.
Pt 18 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 18 Power.
Pt 19 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 19 Power.
Pt 20 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 20 Power.
Pt 21 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 21 Power.
Pt 22 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 22 Power.
Pt 23 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 23 Power.
Pt 24 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 24 Power.
Pt 25 Vel 0 [ SFPM ] ok Calibration table
flow entry

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 29 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
corresponding to
Pt 25 Power.
Pt 26 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 26 Power.
Pt 27 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 27 Power.
Pt 28 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 28 Power.
Pt 29 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 29 Power.
Pt 30 Vel 0 [ SFPM ] ok Calibration table
flow entry
corresponding to
Pt 30 Power.
Gas Parameters
TCC-A 0.962170 ok TCC-A -
Calibration factor.
TCC-B 1.637100 ok TCC-B -
Calibration factor.
TCC-C -1.190600 ok TCC-C -
Calibration factor.
Gas Density 0.074926 [ lb/ft3 ] ok Gas Density lb/ft3 -
Pounds Per
Cubic Foot
kg/m3 -
Kilograms
Per Cubic
Meter

Air Equivalency
Air Equivalence Disabled ok Air Equivalence -
When enabled,
uses polynomial
formula to convert
an air calibration
into equivalent

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 30 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
gas calibration
when computing
gas flow.
Ag 0.000000E+00 ok Ag - Calibration
factor.
Bg 1.000000E+00 ok Bg - Calibration
factor.
Cg 0.000000E+00 ok Cg - Calibration
factor.
Dg 0.000000E+00 ok Dg - Calibration
factor.
Eg 0.000000E+00 ok Eg - Calibration
factor.
Review
Model Number Model TA2 2.x ok Model-
References the
type of Field
Device, usually an
advertised model
number, that is
unique to a single
manufacturer.
Manufacturer MAGNETROL ok Manufacturer
Identification
Code- References
a specific
manufacturer,
which is usually a
company name,
that is responsible
for the
manufacture of
this Field Device.
Magnetrol S/N 71697101001 ok Magnetrol S/N -
Serial number of
this unit.
HART Tag TA2 ok Tag- Text that is
associated with
the Field Device
installation. This
text can be used
by the user in any
way. A
recommended use
is as a unique

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 31 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
label to a plant
that correlates to a
Field Device
label: a plant
drawing, or on a
Control System.
This variable is
also used as a type
of data link layer
address handle.
Descriptor ???????????????? ok Descriptor- Text
that is associated
with the Field
Device. This text
can be used by the
user in any way.
There is no
specific
recommended use.
Firmware Version Ver 2.0f Model TA2 HT ok Firmware Version
- Provides the
version and date
of the Firmware
used by the TA2.
Date 01/01/2001 ok Date- Gregorian
calendar date that
is stored in the
Field Device. This
date can be used
by the user in any
way. There is no
specific
recommended use.
Message ???????????????????????????????? ok Message- Text
that is associated
with the Field
Device. This text
can be used by the
user in any way.
There is no
recommended use.
Final asmbly num 0 ok Final Assembly
Number- Number
that is used for
identification
purposes, and is
associated with

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 32 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
the overall Field
Device.
Device ID 8057033 ok Field Device
Identification-
Uniquely
identifies the Field
Device when
combined with the
Manufacturer
Identification and
Device Type.
Therefore, this
variable cannot be
modified by the
Host user.
Date/Time/Initials ???????????????? ok Date/Time/Initials
- When and by
whom the
configuration was
performed.
Universal rev 5 ok Universal
Revision-
Revision of the
Universal Device
Description, that
the Field Device
conforms to.
Fld dev rev 1 ok Field Device
Revision-
Revision of the
Field Device
Specific Device
Description, that
the Field Device
conforms to.
Software rev 1 ok Field Device
Software
Revision- This
revision
corresponds to the
software or
firmware, that is
embedded in the
Field Device.
Num req preams 5 ok Number of 2 - 20
Request
Preambles-

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 33 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Number of
Preambles
required from the
Host request by
the Field Device.
PV is Flow ok Primary Index
into Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the
Primary Variable
dynamic variable.
SV is Process Temperature ok Secondary Index
into Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the
Secondary
Variable dynamic
variable.
TV is Mass ok Tertiary Index
into Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the
Tertiary Variable
dynamic variable.
QV is R Totalizer ok Fourth Index into
Dynamic
Variables Array-
An index location,
that indicates
which Field
Device dynamic
variable has been
mapped into the

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 34 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Fourth Variable
dynamic variable.
Pipe ID 11.9380 [ inches ] ok Pipe Inside inches -
Diameter - The feet -
flow area must be meters -
entered. This is mm -
done by either
entering the inside
diameter of a pipe
or the cross
sectional area of
the pipe or duct.
Flow Area 0.7773 [ ft2 ] ok Flow Area - The in2 -
flow area must be Square
entered. This is inches.
done by either ft2 - Square
entering the inside feet.
diameter of a pipe m2 -
or the cross Square
sectional area of meters.
the pipe or duct. mm2 -
Square
millimeters.

PV Lwr Range 0.00 [ SCFM ] ok PV Lwr Range MM SCFD


Val Val - Enter the 4 - Million
mA point using standard
the units of cubic feet
measurement per day.
previously MSCFD -
selected Thousand
standard
cubic feet
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -
Normal

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 35 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
cubic
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

PV Upr Range 10000.00 [ SCFM ] ok PV Upr Range MM SCFD


Val Val - Enter the 20 - Million
mA point using standard
the units of cubic feet
measurement per day.
previously MSCFD -
selected. Thousand
standard
cubic feet
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 36 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Normal
cubic
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

Fault State 22mA ok Fault State -


Select how the
Analog output of
the TA2 will
respond if a fault
in the instrument
is detected.
Damping 4[s] ok Damping - Adds
additional time
delay to the TA2.
Enter value as a
time constant
from 0 to 15
seconds.
SV Lwr Range 0.00 [ °C ] ok SV Lwr Range °C -
Val Val - Enter the 4 Degrees
mA point using Celsius
the units of °F -
measurement Degrees
previously Fahrenheit
selected.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 37 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
SV Upr Range 200.00 [ °C ] ok SV Upr Range °C -
Val Val - Enter the 20 Degrees
mA point using Celsius
the units of °F -
measurement Degrees
previously Fahrenheit
selected.
R Totalizer Mode Enabled ok Mode - Enable or
Disable the
totalizer
operation.
R Totalizer Mult 1 ok Multiplier for the
resettable
totalizer. For
example, an
accumulated value
of 1,000 will
display as 10 if
the multiplier is
set to 100.
NR Totalizer 1,000 ok Multiplier for the
Mult non-resettable
totalizer. For
example, an
accumulated value
of 1,000 will
display as 10 if
the multiplier is
set to 100.
Output Function Pulse Output ok Output Function -
select the
operation of the
transistor output.
Pulse Units SCF ok Pulse Units -
Select units of
measurements
used by the pulse
output.
Pulse Multiplier 1 ok Multiplier for the
pulse output. For
example, for a
flow rate of 200
units per
second,use a
multiplier of 10 to
create a pulse rate
of 2000 Hz. If the

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 38 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
pulse rate is too
high, a Pulse
Multiplier Error
will occur.
Pulse Max Freq 10000 ok Pulse Maximum
Frequency - Select
the maximum
frequency that
matches the
specifications of
the external
counter. If the
actual pulse rate is
higher than this
value a “Pulse
Multiplier Error”
will occur.
Alarm Setpoint 0.39 [ SCFM ] ok Alarm Setpoint - MM SCFD
Enter the PV - Million
value that standard
corresponds to the cubic feet
desired alarm per day.
point. MSCFD -
Thousand
standard
cubic feet
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -
Normal
cubic
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 39 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

Alarm Operation Low Flow ok Alarm Setpoint -


Enter the PV
value that
corresponds to the
desired alarm
point.
A 0.00 [ SCFM ] ok Install Factors - A, MM SCFD
B, C; Install - Million
Factors are standard
utilized in cubic feet
situations when per day.
the measured flow MSCFD -
rate may need to Thousand
be adjusted due to standard
variations in flow cubic feet
profile or other per day.
installation SCFD -
factors. The Standard
Install Factors are cubic feet
the coefficients of per day.
the polynomial SCFH -
equation: Standard
Corrected Flow = cubic feet
A + Bx + Cx^2 per hour.
where x is the SCFM -
flow measured by Standard
the TA2 in PV cubic feet
units. per minute.
Nm3/d -
Normal
cubic

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 40 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

B 1.000000 ok Install Factors - A,


B, C; Install
Factors are
utilized in
situations when
the measured flow
rate may need to
be adjusted due to
variations in flow
profile or other
installation
factors. The
Install Factors are
the coefficients of
the polynomial
equation:
Corrected Flow =
A + Bx + Cx^2
where x is the
flow measured by
the TA2 in PV
units.
C 0.000000 ok Install Factors - A,
B, C; Install

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 41 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Factors are
utilized in
situations when
the measured flow
rate may need to
be adjusted due to
variations in flow
profile or other
installation
factors. The
Install Factors are
the coefficients of
the polynomial
equation:
Corrected Flow =
A + Bx + Cx^2
where x is the
flow measured by
the TA2 in PV
units.
Gas Cal Table Table A ok Gas Calibration
Table - Which
stored calibration
table to use for
computing gas
flow.
Auto Switching Disabled error Enable or Disable
the auto switching
operation.
Air Equivalence Disabled ok Air Equivalence -
When enabled,
uses polynomial
formula to convert
an air calibration
into equivalent
gas calibration
when computing
gas flow.
Air Equivalence Disabled ok Air Equivalence -
When enabled,
uses polynomial
formula to convert
an air calibration
into equivalent
gas calibration
when computing
gas flow.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 42 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
STP Pressure 1 Atmosphere ok STP Pressure -
Permits the user to
modify STP
conditions to
application
specific
requirements.
Select Standard
Pressure of 1
atmosphere (14.7
psia) or 1 bar
(14.5 psia).
STP Temperature 21.11 [ °C ] ok STP Temperature °C -
- permit the user Degrees
to modify STP Celsius
conditions to °F -
application Degrees
specific Fahrenheit
requirements.
Enter temperature
used for Standard
Temperature.
Custom Unit Text Custom ok Text describing
the units for the
custom unit
output.
Custom Unit Mult 0.000000 ok Multiplier used to
calculate the
custom unit
output. The
multiplier is
applied based on
the PV.
AO1 4mA Trim 10526 ok AO1 4mA Trim
Value Value
AO1 20mA Trim 52434 ok 20mA Trim Value
Value - Factory
parameter,
displayed for
diagnostic
purposes only.
AO2 4mA Trim 10500 ok 4mA Trim Value -
Value Factory
parameter,
displayed for
diagnostic
purposes only.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 43 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
AO2 20mA Trim 52200 ok 20mA Trim Value
Value - Factory
parameter,
displayed for
diagnostic
purposes only.
Diagnostics
Present Status
Device Status
PV Out of Limits 0 ok Process applied to
the primary
variable is outside
the operating
limits of the field
device.
Non-PV Out of 0 ok Process applied to
Limits the non-primary
variable is outside
the operating
limits of the field
device.
Loop Current 0 ok Analog output 1
Saturated and its digital
representation are
outside the
operating range
limits, and not
responding to
input.
Loop Current 0 ok Analog output 1
Fixed and its digital
representation are
in fixed mode, and
not responsive to
input changes.
More Status 0 ok Field device has
Available more status
available.
Cold Start 0 ok A reset or self test
of the field device
has occurred, or
power has been
removed and
reapplied.
Configuration 1 ok A modification

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 44 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Changed has been made to
the configuration
of the field device.
Device 0 ok Field device has
Malfunction malfunctioned due
to a hardware
error or failure.
Faults
Default Params 0 ok Device
Parameters Reset -
The configuration
information may
have been reset.
Please check the
configuration of
the instrument.
Fault 1 0 ok Fault 2 - consult
Factory.
No Probe Signals 0 ok No probe signal
detected. Check
probe wiring.
Temp Snsr 0 ok Temperature
Shorted sensor fault
detected. Check
probe wiring.
Temp Snsr Open 0 ok Temperature
sensor fault
detected. Check
probe wiring.
Flow Snsr 0 ok Fault 1 - consult
Shorted Factory.
Flow Snsr Open 0 ok Flow sensor fault
detected. Check
probe wiring.
RTDs Reversed 0 ok Flow sensor fault
detected. Check
probe wiring.
Heater Shorted 0 ok RTD wiring
reversed detected.
Check that the
ambient and flow
RTDs are
connected to the
correct locations

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 45 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
on the terminal
block.
Heater Open 0 ok Heater fault
detected. Check
probe wiring.
ZFS Too High 0 ok Heater fault
detected. Check
probe wiring.
Too Few Cal Pts 0 ok Insufficient
number of
calibration data
points. Minimum
number of 10
calibration data
points required.
Calibration data
points must be
entered in
monotonically
increasing values.
Air Equiv Coeff 0 ok The entered Air
Equivalency
factors result in a
calculated flow
curve that is not
monotonically
increasing.
Recheck values
and contact
Magnetrol for
assistance.
User Coeffs 0 ok The entered Users
Installed factors
result in a
calculated flow
curve that is not
monotonically
increasing.
Recheck values
and contact
Magnetrol for
assistance.
Module Failure 0 ok Infrequent
indication of fault
message indicates
automatic
recalibration of

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 46 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
the ADC.
Sustained fault
message indicates
unexpected failure
of the electronics
module. Replace
electronics and re-
calibrate.
Vel > 0 ok Operating outside
UprSnsrLmt calibration
velocity range.
Re-check the
calibration
parameters or
have the TA2 re-
calibrated for
desired velocity
range.
Warnings
Initializing 0 ok The AO2 output is
fixed and not
responding to
input. See
Informational
Status for further
information.
AO2 Loop Fixed 0 ok Initializing - The
TA2 is going
through
initialization.
Flow
measurement will
begin after
completion of the
initialization.
In Test Mode 0 ok Unit is in a
calibration or test
mode. Reported
output is not
representative of
actual conditions.
Vel > UprCalPt 0 ok The measured
flow is higher
than the
calibration range.
Accuracy is
affected.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 47 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Continued
operation with
repeatable
measurement will
occur.
Vel < 0 ok The measured
LowFlowLmt flow is less than
the low flow
cutoff but still in
the measurement
range. Adjust low
flow cutoff.
RTD Drive 0 ok The RTD drive
Circuit circuit has
changed since
calibration. The
change will be
compensated.
Consult Factory.
Dflt Totalizer 0 ok Values contained
in the totalizer
have been
corrupted.
Totalizer reset
required.
Pulse Mult Error 0 ok The pulse output
exceeds the
maximum
frequency.
Change the pulse
multiplier.
Warning 2 0 ok Warning 2 -
consult Factory.
AO1 Loop Trim 0 ok A trim adjustment
Reqd has not been made
of the 4 and 20
mA values on the
primary loop.
Accuracy may be
affected. Adjust
trim at the 4 and
20 mA values.
AO2 Loop Trim 0 ok A trim adjustment
Reqd has not been made
of the 4 and 20
mA values on the

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 48 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
secondary loop (if
provided).
Accuracy may be
affected. Adjust
trim at the 4 and
20 mA values.
Process Temp 0 ok Process
High temperature
exceeds specified
temperature range.
Damage to sensor
will occur with
continued
operation.
Check Install 0 ok Installation factors
Factors may been reset to
defaults. Clear
warning by
changing any one
of the install
factors.
Elec Temp High 0 ok Electronics
Temperature High
- A temperature
exceeding +80°C
has been
measured in the
electronics
compartment.
Elec Temp Low 0 ok Electronics
Temperature Low
- A temperature
below -40°C has
been measured in
the electronics
compartment.
Warning 1 0 ok Warning 1 -
consult Factory.
Informational
Info 3 0 ok Info 3 - consult
Factory.
Info 2 0 ok Info 2 - consult
Factory.
Info 1 0 ok Info 1 - consult
Factory.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 49 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
AO2 Loop Fixed 0 ok Analog output 2
and its digital
representation are
in fixed mode, and
not responsive to
input changes.
AO2 Loop 0 ok Analog output 2
Saturated and its digital
representation are
outside the
operating range
limits, and not
responding to
input.
URV > UprCalPt 0 ok This information
message occurs
when the Upper
Range Value is
outside the
calibration range
of the TA2
Range Too Small 0 ok Minimum Span -
The 4 and 20 mA
setpoints are too
close together.
System Code 0 ok System Code -
consult Factory
History
Current Status OK ok Describes a
fault,warning or
informational
event.
Run Time 6384.2 [ h ] ok Elapsed time since s - Seconds
power on. Also, h - Hours
run time is reset to
zero when the
Status History is
cleared.
Events found 0 ok
Hist. Status ready to use ok
Extended Diagnostics
Delta T 5.77 [ °C ] ok Delta T - Displays
the set point
temperature which

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 50 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
the TA2 is
controlling.
Useful for
diagnostics
information.
Heater Setting 173 [ mA ] ok Heater Setting -
Displays a value
for the heater
setting. Useful for
diagnostics
information.
Signal/PV
PV Flow 6872 [ SCFM ] ok MM SCFD
- Million
standard
cubic feet
per day.
MSCFD -
Thousand
standard
cubic feet
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -
Normal
cubic
meters per
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 51 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

Signal 595.4 [ mW ] ok Signal - Displays


the signal and the
corresponding
value of the PV.
These values can
be compared
against the
original
calibration data to
determine if
configuration of
the TA2 has
changed since
originally
calibrated .
Fixed Signal 0.0 [ mW ] ok Enter the desired
Value Signal in mW.
Process Temperature
Process 28.85 [ °C ] ok °C -
Temperature Degrees
Celsius
°F -
Degrees
Fahrenheit

Max Temperature 174 [ °C ] ok Maximum °C -


temperature ever Degrees
measured for the Celsius
process. °F -
Degrees
Fahrenheit

Elec Temperature

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 52 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
Current 45 [ °C ] ok Present °C -
Temperature temperature Degrees
measured at the Celsius
electronics. °F -
Degrees
Fahrenheit

Max Temperature 80 [ °C ] ok Maximum °C -


temperature ever Degrees
measured for the Celsius
electronics. °F -
Degrees
Fahrenheit

Min Temperature 13 [ °C ] ok Minimum °C -


temperature ever Degrees
measured for the Celsius
electronics. °F -
Degrees
Fahrenheit

Process Variables
PV Flow 6870 [ SCFM ] ok MM SCFD
- Million
standard
cubic feet
per day.
MSCFD -
Thousand
standard
cubic feet
per day.
SCFD -
Standard
cubic feet
per day.
SCFH -
Standard
cubic feet
per hour.
SCFM -
Standard
cubic feet
per minute.
Nm3/d -
Normal
cubic
meters per

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 53 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
day.
Nm3/h -
Normal
cubic
meters per
hour.
Nm3/min -
Normal
cubic
meters per
minute.
Nl/d -
Normal
liters per
day.
Nl/h -
Normal
liters per
hour.
Nl/min -
Normal
liters per
minute.

PV Mass 30624 [ lbs/H ] ok lbs/d -


Pounds Per
Day
lbs/H -
Pounds Per
Hour
lbs/min -
Pounds Per
Minute
kg/d -
Kilograms
Per Day
kg/h -
Kilograms
Per Hour
kg/min -
Kilograms
Per Minute

SV Process 28.87 [ °C ] ok °C -
Temperature Degrees
Celsius
°F -
Degrees
Fahrenheit

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 54 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades

R Totalizer Flow 6130953 [ SCF ] ok Total flow SCF -


measured by this Standard
unit since the cubic feet.
totalizer was last Nm3 -
reset. Normal
cubic
meters.
Nl -
Normal
liters.
lbs -
Pounds
kg -
Kilograms

R Totalizer Time 6385.09 [ h ] ok Total time, since


the totalizer was
reset, over which
the total flow
occurred.
NR Totalizer 386131 [ SCF ] ok Non-resettable SCF -
Flow value representing Standard
the total flow cubic feet.
measured by the Nm3 -
unit. Normal
cubic
meters.
Nl -
Normal
liters.
lbs -
Pounds
kg -
Kilograms

NR Totalizer 6385.09 [ h ] ok Total time over


Time which the total
flow occurred.
Note that rollover
to zero time will
occur when the
total time exceeds
11.4 years.
Custom Unit 0.00 [ unknown ] ok Process
measurement in
customer

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016
Página 55 de 55

Lista de
Nombre Valor Estado Descripción Alcance
unidades
designated units.

file:///C:/Users/US_PROYECTOS/AppData/Local/Temp/PACC241.tmp 16/08/2016