Data – data :
- % Brix nira encer : 104.727,3 kg/jam
- Suhu PAN Pemanas : 103 – 110 °C
- % Brix Nira Kental : 60 %
- Tekanan UBe : 0,5 kg/cm2
- Suhu Uap Bekas :115 °C
- T Nira Masuk : 105 °C
Nira encer
F = 104.727,3 kg/jam
Tf = 105 °C
Xf = 13,5 %
= 112,764 cmHg.abs
Vacuum BP IV = 63 cmHg
= 76 cmHg – 63 cmHg
= 13 cmHg.abs
Penurunan tekanan BP I s/d BP IV (Δ P) = 112,786 – 13= 99,764 cmHg.abs
Perbandingan distribusi presure drop tiap evaporator (Tabel 32.23 “Distribution of presure
Drop between Vessel, Hugot 3rd edition hlm. 579)
11 10,3 9,7 9
BP I = 40 BP II = BP III = BP IV = 40
40 40
11
Tekanan BP I = 112,764 - (40 𝑥 99,764)
= 85,329 cmHg.abs
= 1,160 kg/cm2.abs
Dari tabel 41.1 A Properties of dry saturated steam, Hugot hlm. 1034
T = 103,267 °C
103
Tekanan BP II = 85,329 - ( 40 𝑥 99,764)
= 59,640 cmHg.abs
= 0,811 kg/cm2.abs
Dari tabel 41.1 A Properties of dry saturated steam, Hugot hlm. 1034
T = 93,338 °C
9,7
Tekanan BP III = 59,640 - ( 40 𝑥 99,764)
= 35,447 cmHg.abs
= 0,482 kg/cm2.abs
Dari tabel 41.1 A Properties of dry saturated steam, Hugot hlm. 1034
T = 79,943 °C
9
Tekanan BP IV = 35,447 - ( 𝑥 99,764)
40
= 13cmHg.abs
= 0,177 kg/cm2.abs
Dari tabel 41.1 A Properties of dry saturated steam, Hugot : hlm. 1034
T = 57,023 °C
Perhitungan Air Teruapkan
Misalnya yang teruapkan masing-masing badan adalah X
Air yang teruapkan pada badan IV =X
Air yang teruapkan pada badan III =X
Air yang teruapkan pada badan II =X
Air yang teruapkan pada badan I =X
Total Air yang teruapkan (W) = 4X
%𝑏𝑛𝑒
Sehinggga Total air yang teruapkan (W) = NE x (1- )
%𝑏𝑛𝑘
13,5
W = 104.727,3 kg/jam x (1- )
60
W = 81.163,658 kg/jam
𝑊
X= 4
81163,658
= 4
Y1 = 20.290,914 kg/jam
Sehingga :
evaporator I = 20.290,914 kg/jam
evaporator II = 20.290,914 kg/jam
evaporator III = 20.290,914 kg/jam
evaporator IV = 20.290,914 kg/jam
Total = 81.163,658 kg/jam
Mencari % Brix Masing-Masing Badan Evaporator
𝑟𝑎𝑡𝑒 𝑓𝑟𝑒𝑠ℎ 𝑓𝑒𝑒𝑑 𝑛𝑖𝑟𝑎 𝑒𝑛𝑐𝑒𝑟 𝑥 % 𝑏𝑛𝑒
% Brix =
𝑟𝑎𝑡𝑒 𝑛𝑖𝑟𝑎 𝑒𝑛𝑐𝑒𝑟 𝑚𝑎𝑠𝑢𝑘 𝐵𝑃−𝑗𝑢𝑚𝑙𝑎ℎ 𝑎𝑖𝑟 𝑡𝑒𝑟𝑢𝑎𝑝𝑘𝑎𝑛 𝑝𝑎𝑑𝑎 𝐵𝑃
104.727,3 𝑥 13,5
a. % Brix Evaporator I =
104.727,3−20.290,914
= 16,744 %
104.727,3 𝑥 13,5
b. % Brix Evaporator II =
84.436,386−20.290,914
= 22,041 %
104.727,3 𝑥 13,5
c. % Brix Evaporator III =
64.145,472−20.290,914
= 32,239 %
104.727,3 𝑥 13,5
d. % Brix Evaporator IV =
43.854,558−20.290,914
= 60 %
Perhitungan Panas Jenis Tiap Evaporator
Rumus : Cn = 1 – (0,006 x % Brix)
C0 = 1 – (0,006 x 13,5) = 0,919
C1 = 1 – (0,006 x 16,744) = 0,900
C2 = 1 – (0,006 x 22,041) = 0,868
C3 = 1 – (0,006 x 32,239) = 0,807
C4 = 1 – (0,006 x 60) = 0,640
Perhitungan Neraca Panas dan Neraca Massa Evaporator
Energi Masuk :
1. Uap = mv1 x H1v
2. Nira = mNv x t x C1
Energi Keluar :
1. Panas hilang = Panas masuk x % kehilangan panas
Panas yang hilang efect I = 1,3 % dari total energi masuk
Panas yang hilang efect II = 1 % dari total energi masuk
Panas yang hilang efect III = 0,8 % dari total energi masuk
Panas yang hilang efect IV = 0,5 % dari total energi masuk
2. Kondensat = mv2 x h2l
3. Uap Air = mv2 x H2v
4. Nira = mN2 x t2 x C2
Dimana :
Mv = massa uap (kg/jam) t = suhu (°C)
MN = massa nira (kg/jam) c = panas jenis (kkal/kg°C)
Hv = enthalpy uap (kkal/kg) notasi 1 = keadaan masuk
hl = enthalpy liquid (kkal/kg) 2 = keadaan keluar
Dalam Perhitungan terdapat boiling point rice (BPR) untuk larutan nira yang dihitung
dengan persamaan :
BPR = 1,78x + 6,22 x2, (Geankoplis 3th edition, hlm : 504)
Dimana x adalah % Brix larutan nira, sehingga didapatkan hasil sebagai berikut :
FRAKSI SUHU SUHU
BADAN BPR
NIRA SATURATED SUPERHEATED
BP I 0,167 0,472 103,267 103,739
BP II 0,220 0,694 93,338 94,032
BP III 0,322 1,220 79,943 81,163
BP IV 0,600 3,307 57,023 60,330
Data – data yang dibutuhkan untuk menghitung neraca energi (Tabel 41.1 A Properties
of dry saturated steam, Hugot 3rd, hal : 1034)
P
Evaporator T (°c ) Hv Hl
(kg/cm2°C)
BP 1 1.160 103.267 640.080 103.367
1.160 103.739 640.022 103.839
BP 2 0.811 93.338 636.435 93.338
0.811 94.032 636.710 94.032
BP 3 0.482 79.943 631.277 79.937
0.482 81.163 631.765 81.163
BP 4 0.177 57.023 621.909 56.923
0.177 60.330 623.332 60.230
Evaporator I
Energi masuk
Steam = Ms x 644,3 = 644,3 Ms
Nira = 104.727,3 x 0,919 x 105 = 10.105.660,814
+
= 10.105.660,814 + 644,3 Ms
Energi keluar
Kondensat = Ms x 115 = 115 Ms
Vapor = 20.290,914 x 640,222 = 12.990.683,567
Nira = 84.436,386 x 0,9 x 103,739 = 7.879.335,869
Q Loss = 0,013 x (10.105.660,814 = 131.373,591+8,376 Ms
+ 64644,3 Ms
21.001.393,027 + 123,376 Ms
Nilai Ms dicari dengan metode goalseek dengan mensetting selisih energi masuk dan energi
keluar sama dengan 0, dengan mengubah nilai Ms sehingga didapat harga Ms = 20.901,560
kg/jam
Neraca Energi
Evaporator II
Energi masuk
Steam = 20.901,560 x 640,222 = 12.990.683,567
Nira = 84.436,386 x 0,9 x 103,739 = 7.879.335,836
+
= 20.870.019,436
Energi keluar
Kondensat = 20.290,914 x 93,338 = 1.893.905,811
Vapor = Y2 x 636,710 = 636,710 Y2
+
Nira = (84.436,386- Y2)
x 0,868 x 94,032 = 6.889.743,275 + 81,597 Y2
Neraca Massa
Evaporator III
Energi masuk
Steam = 21.396,859 x 636,710 = 13.623.586,524
Nira = 63.039,526x 0,868 x 94,032 = 5.143.826,907
+
= 18.767.413,430
Energi keluar
Kondensat = 21.396,859 x 79,937 = 1.710.398,696
Vapor = Y3 x 631,765 = 631,765 Y3
+
Nira = (63.039,526- Y3)
x 0,807 x 81,163 = 4.126.780,411 + 65,463 Y3
Neraca Massa
Evaporator IV
Energi masuk
Steam = 22.584,210 x 631,765 = 14.267.917,405
Nira = 40.455,317x0,807 x 81,163 = 2.648.341,728
+
= 16.916.259,133
Energi keluar
Kondensat = 22.584,210 x 56,923 = 1.285.565,933
Vapor = Y4 x 623,332 = 623,332 Y4
+
Nira = (40.455,317- Y4)
x 0,64 x 60,330 = 1.562.039,189 + 38,611 Y4
Neraca Massa
= 88.187,800
= 88,188 ton/jam
= 20,902 ton/jam
= 88.187,800 / 20.901,560
= 4,219
20.901,560
= 𝑥 100%
24.000.
= 87,090 %
Dari perhitungan efisiensi energi didapatkan nilai 87,090 % yang merupakan hasil
perbandingan kebutuhan teoritis dengan energi yang dibutuhkan di pabrik
Perhitungan dengan menggunakan suhu referensi (TR = 0 ⁰C), dengan satuan energi
dalam kkal/jam dan satuan massa dalam kg/jam.