Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 500 A
Machine No : RT 6013484
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using a stander clamp S/N (H239014) and the
results were as follows:

Amp ( Stand) 100 240 500


Amp( Actual) 98 238 500
Error Amp 2 2 0
Error % 2% 0. 8% 0%

The error does not exceed 2%

Conclusion:-

- The welding machines no RT 6013484 , was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.002
Date: 01.Jan.2017

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 500 A
Machine No : RT 070404811
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using a stander clamp S/N (H239014) and the
results were as follows:

Amp ( Stand) 100 240 500


Amp( Actual) 98 238 500
Error Amp 2 2 0
Error % 2% 0. 8% 0%

The error does not exceed 2%

Conclusion:-

- The welding machines no RT 070404811, was calibrated and found


acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.003
Date: 01.Jan.2017
Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 400 A
Machine No : NA001-2005

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using a stander clamp S/N (H239014) and the
results were as follows:

Amp ( Stand) 100 240 400


Amp( Actual) 98 238 400
Error Amp 2 2 0
Error % 2% 0. 8% 0%

The error does not exceed 2%

Conclusion:-

- The welding machines no NA001-2005 , was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.004
Date: 01.August.2019
Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 500 A
Machine No : EN60974-1
Calibration Date: 01.August.2019
Due date : 31.july.2020

The machine was calibrated using a stander clamp S/N (C) and the results were
as follows:

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Amp ( Stand) 100 240 500
Amp( Actual) 98 238 500
Error Amp 2 2 0
Error % 2% 0. 8% 0%

The error does not exceed 2%

Conclusion:-

- The welding machines no RT 0701098 , was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.005
Date: 01.Jan.2017
Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 400 A
Machine No : ZX7-400PE21-400
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using a stander clamp S/N (H239014) and the
results were as follows:

Amp ( Stand) 100 240 400


Amp( Actual) 98 238 400

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Error Amp 2 2 0
Error % 2% 0. 8% 0%

The error does not exceed 2%

Conclusion:-

- The welding machines no ZX7-400PE21-400 , was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.006
Date: 01.August.2019
Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 220 A
Machine No : 29
Serial Number :6022468
Calibration Date: 01.August.2019
Due date : 31.july.2020

The machine was calibrated using a stander clamp S/N (C190060108) and the
results were as follows:

Amp ( Stand) 100 200 220


Amp( Actual) 98 198 220
Error Amp 2 2 0

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Error % 2% 0. 1% 0%
Calibration reference: ISO 17662.
The error does not exceed 5%.

Conclusion:-

- The welding machines no 6022468, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Ahmed Mohamed Eng. Osama sobhy

Certificate No.007
Date: 01.Jan.2017
Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 200 A
Machine No : RI 130623124
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using a stander clamp S/N (H239014) and the
results were as follows:

Amp ( Stand) 50 100 200


Amp( Actual) 49 99 199
Error Amp 1 1 1
Error % 2% 1% 0.5%

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
The error does not exceed 2%

Conclusion:-

- The welding machines no RI 130623124, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa


Certificate No.008
Date: 01.Jan.2017
Calibration Report for Welding Machine
Client : New Aqua
Max Capacity : 0 to 180 A
Machine No : 071206250
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using a stander clamp S/N (H239014) and the
results were as follows:

Amp ( Stand) 50 100 180


Amp( Actual) 49 99 179
Error Amp 1 1 1
Error % 2% 1% 0.5%

The error does not exceed 2%

Conclusion:-

- The welding machines no.071206250, was calibrated and found acceptable.

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.009
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-001
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-001, was calibrated and found acceptable.

***************************
Tested by QC Manager

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.010
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-002
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-002, was calibrated and found acceptable.

***************************
Tested by QC Manager

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.011
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-003
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-003, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Certificate No.012
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-004
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-004, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Certificate No.013
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-005
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-005, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Certificate No.014
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-006
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-006, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.015

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-007
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-007, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.016
Date: 01.Jan.2017
Calibration Report For Electric drying heater

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-008
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-008, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.017
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-009
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-009, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.018
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Machine No : PH-010
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-010, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.019
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-011
Calibration Date: 01.Jan.2017

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-011, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.020
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-001
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Temp ( Stand) 100 200 250


Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-001, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Certificate No.021
Date: 01.Jan.2017
Calibration Report For Electric drying heater
Client : New Aqua
Max Temp. : 250°C
Load Capacity : 5K
Machine No : PH-001
Calibration Date: 01.Jan.2017
Due date : 31.Dec.2017

The machine was calibrated using Infrared Thermometer S/N (N.IR-8) and the results
were as follows:

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org
Temp ( Stand) 100 200 250
Temp ( Actual) 99 200 249
Error °C 1 0 1
Error % 1% 0% 0.4%

The error does not exceed 1%

Conclusion:-

- The Drying heater no PH-001, was calibrated and found acceptable.

***************************
Tested by QC Manager

Eng. Osama Sobhy Eng. Abd El Aziz Mostafa

Head Office: 4 Mahmoud Azmy st. ILI Bldg from Ahmed Oraby st. Sahafeen - Giza-
Tel. : (002)(02)-33055660 Fax (002)(02)- 33040015
Factory: El Tebeen Autostrrad - Industrial Area - Helwan - Egypt. Tel:((002)(02)- 2973993
Email: newaqua@newaqua.org

You might also like