You are on page 1of 5

TECHNICAL SERVICE BULLETIN

Manufacturer Machine Type Series Engine Model Job Order No


Deutz-Fahr Tractor 40686 10004W4
TSB Number Bulletin Type FGI Date
Troubleshooting
Other Service Job   25.8.2014
Knowledge Sharing

Subject
Engine cannot start.

Problem/ Complaint
Engine can’t start.

Symptom
Battery supply power is only ON position of key switch.

Troubleshooting /Service Step


First, we check that the starter motor is good or not .In here, there was no power supply for starter
motor at the start position of key and then checked the starter motor relay. This relay is good. Then, we
checked the connection of key and measured the voltage between the positive terminal and negative
terminal of key switch. There was no voltage because there was no power on negative terminal of key
switch. Therefore, we checked the limit- switches. Drive-gear limit-switch is good. Then, we checked the
limit-switch of P.T.O gear speed controller found that it is loose connection inside. So we adjusted the length
of this limit-switch. Then test run the machine, and machine is good.

Disclaimer : This Technical Service Bulletin (including any attachments)contains service information intended for dealer's service activity and is
protected by company policy. If you are not the intended recipient, you should not receive this bulletin & are hereby notified that any disclosure,
copying or distribution of this bulletin, or taking of any action based on it, it is strictly prohibited

01-000-TD-FRM-017-00
TECHNICAL SERVICE BULLETIN
Manufacturer Machine Type Series Engine Model Job Order No
Deutz-Fahr Tractor 40686 10004W4
TSB Number Bulletin Type FGI Date
Troubleshooting
Other Service Job   25.8.2014
Knowledge Sharing

Analysis

Firstly, we checked the key-switch. In here, battery power supply only ON position of key-switch. So, we
checked step by step as followings.
(1)We checked the supply power of starter motor but there is no negative power.
(2)So we checked the starter relay. In here, the output of relay has no power supply and so checked the supply power
of key-switch but there is no power on negative terminal.
(3)There are two limit-switch which control the negative line of key switch such as gear-box limit-switch and limit-
switch of P.T.O gear speed controller. When we checked these, gear-box limit-switch is good and P.T.O limit-switch is
loose connection inside. So, we adjusted the length of P.T.O limit-switch.

Action and Suggestion

This problem such as engine can’t start, can generally cause because of the breaking of power supply. So,
we should firstly check

(1)the main battery,

(2)battery socket connection looses and

(3)especially limit-switches

Picture

Disclaimer : This Technical Service Bulletin (including any attachments)contains service information intended for dealer's service activity and is
protected by company policy. If you are not the intended recipient, you should not receive this bulletin & are hereby notified that any disclosure,
copying or distribution of this bulletin, or taking of any action based on it, it is strictly prohibited

01-000-TD-FRM-017-00
TECHNICAL SERVICE BULLETIN
Manufacturer Machine Type Series Engine Model Job Order No
Deutz-Fahr Tractor 40686 10004W4
TSB Number Bulletin Type FGI Date
Troubleshooting
Other Service Job   25.8.2014
Knowledge Sharing

Picture

Disclaimer : This Technical Service Bulletin (including any attachments)contains service information intended for dealer's service activity and is
protected by company policy. If you are not the intended recipient, you should not receive this bulletin & are hereby notified that any disclosure,
copying or distribution of this bulletin, or taking of any action based on it, it is strictly prohibited

Failure Description Photos/ Other Failure Description Photos/ Other


01-000-TD-FRM-017-00
TECHNICAL SERVICE BULLETIN
Manufacturer Machine Type Series Engine Model Job Order No
Deutz-Fahr Tractor 40686 10004W4
TSB Number Bulletin Type FGI Date
Troubleshooting
Other Service Job   25.8.2014
Knowledge Sharing

Prepared By

Name: Maung Chit Min Htut Position: App: Mechanic

Fill By Service Department Head/ Supervisor/ BOH :

TSB Grade Criteria TSB Grade Remark/ Comments Checked by

X Complete data

X Complete step

Analysis
Name :
X Suggestion for Corrective Action Kyaw Thu

X Suggestion for Preventive Action

New idea

Fill by TSB Officer :

Comments and Suggestions

Disclaimer : This Technical Service Bulletin (including any attachments)contains service information intended for dealer's service activity and is
protected by company policy. If you are not the intended recipient, you should not receive this bulletin & are hereby notified that any disclosure,
copying or distribution of this bulletin, or taking of any action based on it, it is strictly prohibited

01-000-TD-FRM-017-00
TECHNICAL SERVICE BULLETIN
Manufacturer Machine Type Series Engine Model Job Order No
Deutz-Fahr Tractor 40686 10004W4
TSB Number Bulletin Type FGI Date
Troubleshooting
Other Service Job   25.8.2014
Knowledge Sharing

Commented by :

Disclaimer : This Technical Service Bulletin (including any attachments)contains service information intended for dealer's service activity and is
protected by company policy. If you are not the intended recipient, you should not receive this bulletin & are hereby notified that any disclosure,
copying or distribution of this bulletin, or taking of any action based on it, it is strictly prohibited

01-000-TD-FRM-017-00