You are on page 1of 4

Project Proposed New Villa Design by Date

Client Vanitha 21-Jul-20


Design DESIGN OF ISOLATED FOOTING Checked Revision
Consultant Mahendran -

Design of Isolated Footing


Given Data: Footing ID = F1

Column size Breadth = 380


Depth = 600
Fck = 30
Fy = 415

Axial Load Px = 945.00 kN

Calculations:

Step 1:

Self wt of the footing


5% Self wt = 47.25 kN
Total load P = 992.25 kN
150 kN/m
2
Safe bearing Capacity of Soil SBC =

Step 2:

Area of the footing


Total load / SBC A = 6.62 m2

Equal spacing in both direction as ' x' x req = 1042 mm


X pro = 1050

Size of Footing Req: L = 2.70 m


B = 2.48 m Reqd

Pro: B = 2.70
L = 2.50 Prov

147 kN/m
2
Net upward pressure p
< SBC Hence safe
Step 3:

Bending Moment calculation:

for per m strip Mu(Long) = 121.55 kN.m

Depth required
d reqd = 342.70 mm

D prov = 475 mm
d eff = 425 mm
Step 4:
Ast req = 814 mm2

Spacing Sv(12mm) = 139 mm


Sv(14mm) = 188
Sv(16mm) = 247 mm
Sv(20mm) = 386 mm

FROM ABOVE RESULTS CHOOSE DIA AND SV .


bottom steel in both direction dia = 14
Sv = 175

Ast pro = 879.2 mm2

Step 5:
Check For Shear:

1. one way shear :

From Critical Xn for One Way Shear Vu = 137.81 KN

ζv = 0.32 N/mm2

(from Tables) pt = 0.2068706


ζc = 0.33 N/mm2
ζv < ζc
hence safe in one way shear

2. Two way shear :

From Critical Xn for Two Way Shear Vu = 1084.86 KN


ζv = 0.70 N/mm2

ζc= k*0.28*sqrt (fck) ζc = 2 N/mm2

ζv < ζc

hence safe in Two-way shear


Page
1
Job No
ON 895