PROJECT
TITLE
Uplift Loads (Table 5-21A )
Allowable
Allowable shell stress
Tb=Load per Reqd Area,
Uplift load case NET UP LIFT FORMULA, U U (N) Anchor Bolt at Anchor
Anchor Mpa mm2
stress Mpa attachment
Mpa
[(1.5*Pf-0.08*th)*D2*785]
Failure Pressure -2519561 250.0 250.0 -41992.7 -168.0
-W3
Where
Vertical acceleration earthquake acceleration coeff. Av 0.210 %g
Tank Diameter D 32.025 m
Pressure combination factor Fp 1
Minimum Yield strength of the borrom shell course Fty 250 Mpa
Minimum yield strength of anchor bolts or 250MPa whicheFy 250 Mpa
Tank Height H 20 m
equals Pws x D x H2/2 MWH 6676848 N-m
Seismic moment Mrw 195096209 N-m
Design pressure P 0.5 Kpa
Failure pressure Pf 0.174539785 Kpa
test Pressure Pt 0.000625 Kpa
Wind uplift Pressure PWR 1.745485997 Kpa
Wind pressure on Shell PSW 1042.4 Kpa
Roof plate thickness th 5 mm