You are on page 1of 1

4/1/2020

PROJECT
TITLE
Uplift Loads (Table 5-21A )

Allowable
Allowable shell stress
Tb=Load per Reqd Area,
Uplift load case NET UP LIFT FORMULA, U U (N) Anchor Bolt at Anchor
Anchor Mpa mm2
stress Mpa attachment
Mpa

Design Pressure [(P-0.08*th)*D2*785] -W1 -2095344.1 104.2 166.7 -34922.4 -335.26

Test Pressure [(Pt-0.08*th)*D2*785] -W1 -2497389 138.9 208.3 -41623.2 -299.7

[(1.5*Pf-0.08*th)*D2*785]
Failure Pressure -2519561 250.0 250.0 -41992.7 -168.0
-W3

Wind Load PWR*D^2*785+(4*MWH/D)-W2 -6.8992E+05 200.0 208.3 -11498.7 -57.5

Seismic Load (4*Mrw/d)-W2*(1-0.4*Av) 2.1685E+07 200.0 208.3 361414.6 1807.1

Design Pressure [(Fp*P+PWR-0.08*th)*D2*785]+


1.4390E+05 138.9 208.3 2398.3 17.3
b+Wind [4*MWH/D] -W1

Design Pressure [(Fp*P-0.08*th)*D2*785]+


2.2455E+07 200.0 208.3 374256.9 1871.3
b+Seismic [4*Mrw/D] -W1*(1-0.4*Av)
Fragibility
[(3*Pf-0.08*th)*D^2*785]-W3 -2308778 250.0 250.0 -38479.6 -153.9
Pressure c
Maximum required area = 1871.3 mm2
Reqd. Root dia uncorroded = 48.81 mm2
Required corroded dia 48.81 mm2
CA Anchor Bolt 0 mm2
Size of Bolt selected M 54
Nos. of Bolts No. 60

Maximum Uplift load = 22455 KN

Where
Vertical acceleration earthquake acceleration coeff. Av 0.210 %g
Tank Diameter D 32.025 m
Pressure combination factor Fp 1
Minimum Yield strength of the borrom shell course Fty 250 Mpa
Minimum yield strength of anchor bolts or 250MPa whicheFy 250 Mpa
Tank Height H 20 m
equals Pws x D x H2/2 MWH 6676848 N-m
Seismic moment Mrw 195096209 N-m
Design pressure P 0.5 Kpa
Failure pressure Pf 0.174539785 Kpa
test Pressure Pt 0.000625 Kpa
Wind uplift Pressure PWR 1.745485997 Kpa
Wind pressure on Shell PSW 1042.4 Kpa
Roof plate thickness th 5 mm

Roof Plate thickness, corroded thcor 5 mm


Dead Load of shell minus CA and any dead load other thaW1 2175854 N
Dead Load of shell minus CA and any dead load includingW2 2929163 N
Dead load of shell using nominal thickness and any
other dead load other than roof W3 2408304 N

You might also like