You are on page 1of 34

ITEM DESCRIPTIONS AMOUNT

BILL No.1 PRELIMINARIES


Plants ,tools and Scaffolding

A The contractor shall provide at his own risk and cost all materials
scaffolding, tools , plants transport and workmen required for the
works except in so far as may be stated otherwise herein. No timber
used for scaffolding, formwork , or similar purposes shall be
used afterwards in the permanent works.

Watching and Lighting

B The contractor shall provide at his own expenses all watching ,


lighting and protection of the works , materials and public through
fares as may be necessary for the safety of the works and for the
public and his own employees.

Public and Private roads

C The contractor will be required to make good at his own expenses


any damage he may cause to the present road surfaces , road
cross overs , open culverts and drains , water mains , telephone
and electricity installation at the access to the site during the
period of the works.

Water for the Works

D The Contractor shall provide at his own risk and cost all water for
the use in connection with the works including Sub- contractor's
work , make arrangement for the connection to the main and
provision of a meter for all water used by him throughout the
construction and pay all costs , fee and charges in connection
herewith. He shall provide all necessary storage, cisterns, tubing
and the like and remove on compleion. All water used in the works
shall be fresh, clean and pure; free from organic matters and
alkaline substances in solution or in suspension.

Lighting and Power for the works

E The Contrator shall arrange for a temporary meter and supply to


the site and shall provode all temporary wiring power and lighting
points for the whole of the works and clear away when no longer
required. He shall pay all charges for the same and for current
consumed.

SUB-TOTAL CARRIED TO COLLECTION


1/1
ITEM DESCRIPTIONS AMOUNT

Area to occupied by the Contractor

A The area of the site which may be occupied by the contractor will
be indicated to him and the contractor must not occupy or
encroach on any ground beyond the area as directed.

B The contractor shall make every effort to avoid and in any event
shall be liable for any undue disturbance amounting to nuisance
to the occupiers of the contigous properties by reasons of
noise, dust, traffic and the like or by negligence in controlling his
workmen or materials.

Temporary buildings for use by the contractor


C The contractor shall, at his own cost, supply and erect all temporary
buildings, sheds, messrooms and stores with floors at least 150mm
above ground level. No office, stores or other temporary building
shall be erected on the site without first obtaining the consent of the
architect as to the type of temporary building to be supplied and the
position on which they are to be erected.

Protection of the works


D Cover-up and effectively protected works from injury by weather ,
traffic or otherwise and case up and protect cells, stops, joinery
and all other work as may be necessary.

Testing:
E The Architect may, whenever he considers it desirable, test any
materials before they leave the maker's premises as well as after delivery
on the site, and the Architect shall be at liberty to reject any materials
after delivery should he consider them unsatisfactory, notwithstanding
the preliminary test and approval of the materials at the maker's premises.
The costs of these tests are to be borne by the contractor.

F When directed by the Architect, samples of materials (the same being


taken by approved sampling methods) are to be supplied by the contractor
for laboratory tests and shall be delivered by the contractor at his own
cost to the Architect's office or as otherwise directed.

G The contractor shall, whenever so instructed by the Architect, cut


out sections of work executed or samples of materials incorporated
therein and shall deliver them where directed for the purpose of
testing. All work disturbed shall be made good forthwith by the
contractor. All costs incurred in cutting out, making good and
delivering as aforesaid, shall be borne by the contractor.

SUB-TOTAL CARRIED TO COLLECTION


1/2
ITEM DESCRIPTIONS AMOUNT

Sign boards
A The contractor shall, unless otherwise directed, obtain any necessary
consent or license from the Local Authority and immediately upon
commencement of the works the contractor shall, in accordance with
the details supplied by the Architect, make and erect a sign board
showing the name of the Employer and such other information as shall
be directed and approved by the Architect.

Removal of rubbish and cleaning


B The contractor shall remove all rubbish and superfluous materials
from the site of the works with all reasonable speed from time to
time and at completion.

C The contractor shall also properly cleanse floors, woodwork, steps,


paving, roads, hard standings, glass (inside and outside), cisterns,
flushing cisterns, all finishing and leave the whole of the works in
a sound and perfect condition free from all defects whatsoever,
and to the satisfaction of the Architect.

SUB-TOTAL CARRIED TO COLLECTION

COLLECTION

Page 1/1

Page 1/2

Page 1/3

TOTAL PRELIMINARIES CARRIED TO GENERAL SUMMARY


1/3
ITEM DESCRIPTION QTY UNIT RATE AMOUNT
BILL No.2 PC SUMS
PRIME COST & PROVISIONAL SUMS:

The following Prime Cost Sums are for the works


to be executed by Nominated specialist sub
contractor or any other approved undertaking:

A Electrical Installations within the Building Sum

Add: for profit 10'%

Add: for General attendance Sum

B Electrical Service Line including installation of meter Sum

Add: for profit %

Add: for General attendance Sum

C Water Service Line including installation of meter Sum

Add: for profit %

Add: for General attendance Sum

The following Provisional Sums are for the works


or costs which can not be foreseen, defined or
detailed during prepation of the Bills of Quantities
and are to be spent in whole or part at the
discretion of the Client:

D CONTINGNCY SUM; to be expended at the sole


discretion of the Client and upon the Project
Manager issue of instruction. Sum

PRIME COST & PROVISIONAL


SUMS CARRIED TO GENERAL SUMMARY
ITEM DESCRIPTION QTY UNIT RATE AMOUNT
BILL No. 3. SUBSTRUCTURE

ELEMENT No. 1: SUBSTRUCTURE


(All Provisional)
SITE PREPARATION
EXCAVATIONS AND EARTHWORKS.
A Excavate oversite average 150mm deep to remove
vegetable soil and remove away from site. m2

B Clear site of small trees,bushes, grass, undergrowth


and the like including grubbing up their roots m2
Excavation
C Excavate foundation trenches starting from stripped
level not exceeding 1.5m deep; m3

D Excavate pits for column bases and the like commen


ing at formation level and not exceeding 1.5m deep m3

E Earth backfilling of excavated material around


foundations well rammed and consolidated. m3

F Remove surplus excavated materials away from


the site m3

Disposal of water:
G Keeping all excavations free from general
water (except spring or running water) by pumping,
bailing or by other means necessary. Item

Planking and Strutting:


H Plunking and strutting to uphold and maintain sides
of excavations including its subsequent removal. Item

Hardcore:
I 150mm thick Bed levelled compacted and blinded to
receive damp proof membrane (mesured separately) m2

To collection
3/1/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Sterilization
A Aldrin 0.5% solution applied at a rate of 7 litres
per square metre on hardcore. m2

B Aldrin 0.5% solution applied at a rate of 8 litres


per linear metres per 300mm depth per 230mm
width to backfilling to one side of foundation walls m

CONCRETE WORK

Plain Insitu Concrete Grade "7"

C 50mm Blinding m2

Plain in situ Concrete Grade "15"

D Foundations m3

E 100mm Bed m2

Reinforced in situ concrete grade" 25"


including vibrating around reinforcement

F Column bases m3

G Columns

Reinforcement:
High tensile hot rolled deformed steel bar
reinforcements to B.S. 4449;1969

H 16mm Diameter bars

Sawn formwork to:

I Vertical sides of foundations m2

J Edges of beds and the like over 75 but not


exceeding 150mm wide m

Sub total collection


3/1/2
ITEM DESCRIPTION QTY UNIT RATE AMOUNT
BLOCK WORK

Solid concrete blocks to BS 2028 type "A"


bedded and jointed in cement mortar 1;3

A 230mm Wall. m2

Damp proof course:


B Hessian based bitumen damp proof course to
BS 743 type" 5A", 230mm wide laid horizontally on
blockwork m

C 500mm Gauge polythene damp proof membrane laid


horizontally over blinded hardcore bed (Measured
separately) m2

Finishes

D 12mm Cement and sand (1:3) rendering to concrete


or blockwall, externally. m2

Painting:

E Prepare and apply two coats of black bituminous


paint on rendered concrete or block wall surfaces,
externally. m2

To collection

COLLECTION

Page No 3/1/1

Page No 3/1/2

Page No 3/1/3

SUBSTRUCTURE
CARRIED TO SUMMARY OF BILL
3/1/3
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No. 2: FRAME:

CONCRETE WORK:
Reinforced in situ concrete (1:2:4) grade 20
nominal mix:

A Columns m3

B Ring beams m3

Precast reinforced in situ concrete (1:1:5:3)


Precast concrete; grade 20; including hoisting to
position; bedding and pointing in cement mortar (1:4)

C 200 x 65mm thick rebated weathered and throated


window sill; finished fair all round over. m

Reinforcements:
Supply and fix hot rolled mild steel round
bar reinforcements to B.S. 4449; straight or bent
in any location:

D 12mm diameter bars Kg

E 6mm diameter stirrups. Kg

Formwork:
Supply and fix sawn softwood formwork:

F Vertical sides of columns; over 300mm girth m2

G Sides of beams or the like; over


225 - 300mm girth. m

H Soffits of beams or the like; 75- 150mm wide m

J Ditto; 225 - 300mm wide. m

K Ditto; 225 - 300mm wide; circular; to a radius


of 1078mm. m

FRAME
CARRIED TO SUMMARY OF BILL
3/2/1
ITEM DESCRIPTION DESCRIPTIONUNIT RATE AMOUNT

ELEMENT No. 3: WALLING:


Precast concrete grade 25 including hoisting to
position and bedding and pointing with cement
mortar (1;4)

A 300mm x100mm Weathered and throated


sill with fair finishes on all exposed surfaces m

Reinforced concrete grade "25" including


vibrating around reinforcement

B Lintels m2

C Horizontal beams m3

D 150mm Horizontal suspended beams m3

E Columns m3

Reinforcement

High tensile hot rolled deformed steel bar


reinforcement to BS,4449:1969

F 10 mm Bar kg

G 16mm Bar kg
Sawn formwork to;
H Sides and soffits of horizontal beams m2

Sides and soffits of horizontal lintels m2

Vertical sides of column m2

Horizontal soffits of suspended slab m2

BLOCK WORK

Solid concrete blocks to BS 2028 type "A"


bedded and jointed in cement mortar 1;3

150mm Wall.

WALLING
CARRIED TO SUMMARY OF BILL
3/3/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No. 4: ROOF

ROOF COVERING

28 Gauge corrugated iron sheet as manufactured by


ALAF fixed on timber purlin spaced at 900mm centre
to centre with roofing nails with 1.5 side laps, 150mm
end laps
A Roof covering; sloping not more than
45 degrees from horizontal. m2

B Raking cutting m

Corrugated galvanized iron sheets roofing accessories


with approved reference including approved galvanized
iron roofing nails

C 28 Gauge half rounded ridge 550mm girth m

D 28 Gauge half rounded hip capping 500mm girth m

Plain Insitu Concrete Grade "7"

E 300mm Girth kerbs m

Reinforced concrete grade "25" including


vibrating around reinforcement

F 150mm Thick horizontal suspended slab m2

Reinforcement

High tensile hot rolled deformed steel bar


reinforcement to BS,4449:1969

G 10 mm Bar kg

H 16mm Bar kg

Sub total collection


ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Sawn formwork to;

A Horizontal soffits of suspended slab m2

B Vertical sides to slab over 75mm width but not


150mm width m

C Vertical sides to kerbs over 75mm width but not


150mm width m

Bitumen roofing felt to BS 747, lapped 150mm at joints


compriing of two layers of type 2B felt bounded to screed and
one layer of type 2E mineral surfaced felt bonded
to lower layers with hot bitumen compound.

D Roof covering to falls and slopes not exceeding 15


degrees from horizontal m2

Cement and sand (1:3) with approved water proofing


additive, steel trowelled smooth.

E 40mm (Average) screed to falls, cross falls and slopes


not exceeding 15 degrees from horizontal to receive
roofing felt. m2

Sawn formwork to;

F Horizontal soffits of suspended slab m2

G Vertical sides to slab over 75mm width but not


150mm width m

H Vertical sides to kerbs over 75mm width but not


150mm width m

Sub total collection


3/4/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Bitumen roofing felt to BS 747, lapped 150mm at joints


compriing of two layers of type 2B felt bounded to screed and
one layer of type 2E mineral surfaced felt bonded
to lower layers with hot bitumen compound.

A Roof covering to falls and slopes not exceeding 15


degrees from horizontal m2

Roof drainage

28 Gauge galvanized mild steel water gutter


as manufactured by ALAFor other equal and
approved.

Half round water gutter 600mm girth supported by


25x4mm thick mild steel brackets fixed to fascial board m

Extra over ,ditto for stop ends nr

Extra over ,ditto for nozzle joints nr

Extra over 180mm girth shallow rainwater for


pipe secured nozzle joints. nr

ROOF STRUCTURE

CARPENTRY

Treated softwood pressure impregnated with


preservatives

50x100mm Wall plate m

50x100mm Rafters m

50x100mm Struts m

50x100mm Tie beam m

50x50mm Purlines m

25x250 Fascial board m

Sub total collection

COLLECTION

Page No 3/4/1

Page No 3/4/2
ROOF
CARRIED TO SUMMARY OF BILL
3/4/2
ITEM DESCRIPTION QTY UNIT RATE

ELEMENT No. 5: DOORS

JOINERY

Prime quality Mninga or other equal and


approved hardwood

A 40mm Thick panelled door size 910x2000mm


high comprising of 40x100mm stiles, top rail
40x150mm ,bottom rail 40x200mm and
intermediate rail forming four panels ; two panels
size 305x700mm and other two panels size
300x710mm each filled in with and including 25mm
thick moulded boarding tongue and grooved to
stiles and rails nr

B Ditto size 810x2000mm high divided into four


panels two panels size 255x700mm and other
two panels 610x300mm ditto nr

C 40mm Thick flush door with standard solid core


faced with 6mm thick plywood to both sides
glued to core under pressure and 15mm thick
lipping to all four edges nr

Frames and finishings

D 45x145mm Frame fixed to hardwood grounds .


(measured separately) m

E 45x145mm Mullion with two labour m

F 45x145mm Transome; three labour. m

G 20x30mm Glazing beads m

Sawn Hardwood

H 75x15mm Ground plugged. m


Sub total collection

DOORS
CARRIED TO SUMMARY OF BILL

3/5/1
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No. 6: WINDOWS:

Metal Work
Supply and fix aluminium window units as
manufactured by casement African Co.Ltd as
approved by Architect, coloured, anodized aluminium
complete with glazing 6mm thick ordinary quality clear
sheet glass with 80 x 40 x 20mm minimum thickness
of frame with approved necessary locks, hinges, pull
handles,glazing beads,screws including mullion
and transom.

A Sliding window overall size 2500 x 1800mm high with nr


two opening portions and three vents.

B Ditto size 1800 x 1800mm ditto. nr

C Ditto size 1500 x 1500mm, ditto. nr

D Ditto size 400 x400mm nr

Supply and fix mild steel grilles window comprising


of 25x25mm square hollow section mild
steel frame, 20x3mm thick flat bars welded
together to pattern including all necessary
additional materials,grinding and polishing all
welded conditions to smooth surfaces welded
to metal rods fixed in the wall.

E Size 2500 x 1800mm W1 nr

F Size 1800 x 1800mm W2 nr

G Size 1500 x 1500mm W3 nr

Sub total collection

WINDOW COLLECTION

Page 3/6/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

PLUMBING & ENGINEERING INSTALLATION:

Sanitary Appliances:
Supply and fix the following sanitary appliances; Ex - Italy
including all connections and screwing and bolting to floor
or wall where necessary:

A White vitreous china W.C pan Western type to BS 5503


complete with low level 13 litre cistern to BS 1125 with
cover and cast iron brackets; deep seal 'S' trap; plastic
cover to BS 1254;12mm ball valve; black plastic seat
and cover domex screws. nr

B White vitreous china Andria W.C suite (Squatting type)


with 'P' trap conceala high level 7.5 litres capacity
cistern with freeflo plastic syphon; 1/2" micro valve HP/LP
ball valve; side supply and 19mm overflow set; simpla
inlet connector plastic flush pipe. nr

Shower tray and fittings ; enemelled tray waste outlet


and trap; chromium plated tap ; riser pipe and 100mm
diameter rose:

C 900 x 900mm tray ; pointing with white cement ;


jointing trap to waste fitting and waste pipe ; mixer tap;
flexible telephone shower and hook; riser pipe with
chromium plated screws, angled shower arm and head,
to glazed tile background requiring plugging. nr

D Single bowl single drainer stainless steel sink complete


with 15mm diameter chromium plated mixer tap Ex - Italy;
chain and plug; and a deep seal 32mm chrome bottle
trap with cast iron brackets. nr

E 405 x 380mm Ceramic wash hand basin complete with


15mm diameter chromium plated mixer tap Ex - Italy;
chain and plug; and a deep seal 32mm chrome bottle
trap with cast iron brackets. nr

Sub total collection


3/7/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

A Supply and fix automatic instantaneous electric water


heater; ARISTON or equal and approved; 50litres
capacity; complete; wall mounted including connection
services and electricity. nr

B Recessed toilet paper roll holder; ceramic;


size 150 x 150mm. nr

C Recessed soap dish; ceramic; size 150 x 150mm. nr

D Towel rail; chromium plated; 600mm long; plugged. nr

E Supply and fix 6mm thick polished glass mirror size


450 x 600mm with grounded and chamfered edges
four times drilled and plugged screwed with
chromium plated domex screws. nr

F Supply and fix 1Nos. elevated water storage tank as


manufactured by SIMBA PLASTICS or approved
equal; 2000 litres capacity complete with 19mm
diameter high pressure ball valve to BS 1212 part 1;
plastic float; (Ex - UK); including all feed and supply
pipes and fittings; complete with solid wall riser. nr

NAHAN PVC traps; Ex-Italy with removable grating;


seal joint to mild steel pipe:

G 150 x 150mm; 50mm inlet; 50mm outlet nr

Galvanised wire balloon gratings; to BS 416; with


mosquito wire proofing; fixing with binding wire:

H For 100mm pipe outlet nr

Sanitary installations; pipework; UPVC pipes and


fittings; grade 'B' as manufactured by PLASCO:

Soil; waste and vent pipes; solvent welded joints in


running length:

J Vent pipe; 100mm diameter m

Extra over for:

K Plain bend; 100mm diameter nr

Sub total collection


3/7/2
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Sanitary installations; pipework; galvanised mild steel


pipes and fittings; medium grade; to BS 1387; fittings
to BS 3868; screwed and socketed joints:

A Pipe; 38mm diameter m

Extra over for:

B Tee; 38mm diameter nr

C Plug; 38mm diameter nr

D Pipe; 32mm diameter m

Extra over for:

E Tee; 32mm diameter nr

F Plug; 32mm diameter nr

G Elbow; 32mm diameter nr

Cold and hot water Installations:

Sanitary installations; pipework; galvanised mild steel pipes


and fittings; medium grade; to BS 1387; fittings to BS 3868;
screwed and socketed joints:

H Pipe; 19mm diameter; chased to walls m

Extra over for:

J Elbow; 19mm diameter nr

K Tee; 19mm diameter nr

L Union; 19mm diameter nr

M Nipple; 19mm diameter nr

Sub total collection


3/7/3
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

A Pipe; 15mm diameter; chased to walls m

Extra over for:

B Elbow; 15mm diameter nr

C Tee; 15mm diameter nr

D Nipple; 15mm diameter nr

E Socket; 15mm diameter nr

F Reducing bush; 20 x 15mm diameter nr

Ancillaries:
Draw off taps; stop valves; copper alloy to BS 5154
or BS 1010; or as manufactured by Dizayn; joint to
Dizyan pipes:

G 19mm diameter non-return valve. nr

H 19mm diameter bib cork. nr

J 19mm diameter stop valve. nr

K 15mm diameter bib taps. nr

L 15mm diameter stop valve. nr

Builder's Work:
M Allow sum for all builder's work in connection with
Plumbing and Engineering installation including chasing
away walls, trench excavation, making good, backfillng
and compacting in trench and removal of surplus material
away from site. Item

Sub total collection


3/7/4
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Stopcock pit/ meter chamber:

A Construct stop cork pit/ chamber internal dimensions


500 x 500 x 500mm in 100mm solid bock wall; sides
finished fair as work proceed; 150mm thick concrete grade
15 bed; 100mm thick precast concrete grade 20 cover slab
reinforced with BRC mesh; with lifting devices; including
excavations, backfilling and removal of surplus materials. nr

Sub total collection

COLLECTION

Page No 3/7/1

Page No 3/7/2

Page No 3/7/3

Page No 3/7/4

Page No 3/7/5

PLUMBING INSTALLATION
CARRIED TO SUMMARY OF BILL
3/7/5
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No. 8: ELECTRICAL INSTALLATIONS

Builder's work in connection with Electrical Installations:


(All provisional)

Allow for necessary cutting away holes, chases and the like
for and making good afterthe works on concealed electrical
installations to Architect's approval.

A Distribution board points nr

B Power points with associated switches nr

C Lighting points with associated switches. nr

D Chase blockwall for UPVC conduiting and make good Item

E Cut holes thrugh 230mm and 150mm block wall for


small pipes; make good. Item

Sundries:

F Allow for preparing and producing four (4) copies of


"AS BUILT DRAWINGS" of the electrical installations
showing al the electrical fittings and wiring on plan. Item

ELECTRICAL INSTALLATIONS
CARRIED TO SUMMARY OF BILL
3/8/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No. 9: INSITU FINISHES:

Internal in situ finishes; cement and sand in two


coats, 12mm thick first coat of cement and sand
(1:4) and second coat ,3mmn thick cement, sand and l
lime (1:1;5.) steel

A 15mm thick; to wall surfaces m2

Tyrolean Rendering in two coats steel trowelled to


a smooth finish

B 22mm To walls m2

Beds and backings:

Cement and sand (1:3) wood floated surface

C 12mm Backing to receive ceramic wall tiles m2

D 9mm Bed to receive ceramic tiles skirting m2

E 31mm Screed to receive ceramic floor tiles m2

Cement and sand (1:3) with approved water proofing


additive, steel trowelled to smooth finish.

F 40mm (Average) screed to falls, cross falls and slopes


not exceeding 15 degrees from horizontal to receive
roofing felt. m2

Terrazzo floor finish in two coats wood floated,cured


and polished

G 40mm Floors m2

H 25mm Skirting;150 mm high with top rounded edge


and coved joints nr

Sub totalcollection
3/9/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT
TILES, SLABS AND BLOCK FINISHING.

High quality non slippery ceramic floor tiles fixed to


bed with adhesives and jointed with coloured grout to
Architect's approval

A 225x225x9mmTiling to floor m2

B 40x3mm Ebonite dividing strips m

Glazed ceramic wall tiles with cushion edges to Bs 1281


fixed to backings with adhesive and pointing with
white cement

C 150x150x6mm Tilling to walls m2

D 9mm Skirting ;150mm high with top rounded edge m

Plain sheet finishings

E 50x50mm Softwood brandering m

F 100x19mm Hardwood boarding to ceiling m2

G 10mm Chipboard ceiling m

H Extra over ditto for access panel size 600x600mm


secured with screws nr

I 45 x45mm Decorative moulded cornices m

Sub total collection

Page 3/9/1

Page 3/9/2 `

FINISHING
CARRIED TO SUMMARY OF BILL

3/9/2
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No. 10: PAINTING

Prepare and apply one undercoat and two finishing


coats of emulsion paint;

A Plastered wall surfaces over 200mm but not exceeding m


300mm girth

B Plastered wall surfaces over 300mm girth

C Column m2

D 15mm To ceiling m2

Prepare and apply one undercoat and two


finishing coats of gloss paint;

E Plastered wall surfaces over 300mm girth m2

F Grilles m2

G Wood frame m

H Wood surface over 100mm but not exceeding 200mm


girth m

I Ditto over 200mmbut not exceeding 300mm girth m

J Wood surface over 300mm girth m2

Prepare and apply one undercoat and two finishing


coats of french varnish on woodwork;

K Wood surface not exceeding 100mm girth m

L Wood surface over 100mm but not exceeding 200mm m

M Wood surface over 200mm but not exceeding 300mm m

N Wood surface over 300mm m2

Prepare and apply one coat red oxide primer on


metal work

O Grilles m2

PAINTING
CARRIED TO SUMMARY OF BILL

3/10/1
ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No. 11: DRAINAGE


(ALL PROVISIONAL)

Gullies;
A Construct gully; size 150x150mm; comprising
of 100mm diameter UPVC trap; 100mm thick plain
in situ concrete (1:3:6) bed and surround; precast
concrete (1:1:5:2) cover with 3 Nos. 6mm diameter
steel bars; cement sand (1:4) plaster to walls internally nr

Manholes;
B Manhole; size 750x750mm comprising of 150mm
thick solid concrete blockwalls resting on 100mm
thick plain concrete (1:3:6) bed; 200x200mm
benching forming half round channels 100mm dia;
cement sand (1:4) plaster to walls internally; complete
with 610x460mm cast iron manhole cover nr

C Construct a complete set of septic tank and


soak pit type III Item

D Excavate trench size to receive drain pipes; commencing


at ground level and not exceeding 1.5m deep; including
levelling bottoms of excavations, backfilling excavated
material and removal of surplus material m

E 75mm thick sand layers, 400mm wide sand compacted


in 150mm layers to receive PVC pipes m2

Pipework
Unplasticised PVC pipes and fittings to B.S 3506
class 'B' with push fit joints in the running length; as
manufactured by Plasco or approved equal:

F 100mm diameter pipe. m

DRAINAGE
CARRIED TOTAL SUMMARY
3/11/1
SUMMARY OF BILL No. 3:

ITEM DESCRIPTION AMOUNT

1 ELEMENT No. 1: SUBSTRUCTURE

2 ELEMENT No. 2: FRAME

3 ELEMENT No. 3: WALLING

4 ELEMENT No. 4: TOTAL FOR ROOF

5 ELEMENT No. 5: DOORS

6 ELEMENT No. 6: WINDOWS

7 ELEMENT No. 7: PLUMBING

8 ELEMENT No. 8: ELECTRICAL INSTALLATIONS

9 ELEMENT No. 9: FINISHES

10 ELEMENT No. 10: PAINTING AND DECORATIONS

11 ELEMENT No. 11: DRAINAGE

TOTAL
CARRIED TO GENERAL SUMMARY
GENERAL SUMMARY :
ITEM DESCRIPTION AMOUNT

1 BILL No.1: PRELIMINARIES

2 BILL No. 2: PRIME COST AND PROVISIONAL SUMS

MEASURED WORKS

3 BILL No. 3: MAIN HOUSE

4 ALLOW FOR:

5 ADD: 18% VAT

6 ADD: CONSULTANCY AND SUPERVISION FEE 5%


ITEM DESCRIPTION QTY UNIT
ELEMENT NR 1.
DEMOLITION AND ALTERATIONS

DEMOLITION GENERALLY

Alll descriptions shall be deemed to include for all removal to


dump site or tip and disposal of debris accruing from operations
A on site 1 Item

Avoid of nuisance

The works in Demolition shall be carried out to cause as little


inconvenience to adjoining owners and public as possible. The
works must be well watered to prevent the nuisance of dust
B arising. 1 Item

Wrecking

C No mechanical wrecking shall be allowed 1 Item

Removal or cleaning existing floor finishings

Hacking off existing floor finishes including removal of particles /


tiles / clean thoroughly; prepare surface to receive new finishing
D materials; make good all works disturbed (approx. 169m2) 1 Item

Removing existing wall finishings and decorations

Wire brush existing wall plaster; internally (intended degree of


effort to include for use of paint scraper to remove loose or
defective plaster ); repair and fill dents and voids with a cement
filler sanded smooth, and prepare to receive new decorations
E (Approx 578 m2) 1 Item

Hacking off existing wall finishes including removal of particles/


tiles/ clean thoroughly, prepare surface to receive new finishing
F materials: make good and all works disturbed (approx. 304m2) 1 Item

Removal existing ceiling finishings and decorations


Wire brush existing ceiling plaster; internally ( intended degree of
effort to include for use of paint scraper to remove loose or
defective plaster) repair and fill dents and voids with a cement
filler sanded smooth, and prepare to receive new decorations
G (Approximately 169 m2) 1 Item

Removal of existing plumbing appliances

Carefull remove / unfix all existing WC's and flushing cisterns,


Hand wash Basins, Urinals, toilet paper holders, soap dishes,
tower rails etc and, hand over to the client including making good
H all works disturbed 1 Item

Removal of existing water pipes system

Carefull remove / unfix all existing IPS/PVC/ Galvanized water


supply / drainage pipes and hand over to the Client including
J making goods all works distrubed 1 Item

Removal / Demolition of raised toilet floor to normal level.

Carefully remove / demolish existing raised floor to normal level


K as directed by the site Engineer. 1 Item

Remove of Casement Windows

Carefully remove existing casement windows and hand over to


client : including making good all works distrubed ready to receive
L new aluminium sliding windows. 1 Item

To collection
RATE AMOUNT

350,000.00 350,000.00

60,000.00 60,000.00

120,000.00 120,000.00

202,800.00 202,800.00

289,000.00 289,000.00

364,800.00 364,800.00
84,500.00 84,500.00

213,000.00 213,000.00

450,000.00 450,000.00

65,000.00 65,000.00

240,000.00 240,000.00

2,439,100.00