Nonstandard Maintenance

Base Transceiver Station Equipment

NM:BTSE
BS-240 / 240 II / 240XL / 240XL II
A30808-X3247-A340-2-7620
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

f Important Notice on Product Safety


DANGER - RISK OF ELECTRICAL SHOCK OR DEATH - FOLLOW ALL INSTALLATION INSTRUCTIONS.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected to the system must
comply with the applicable safety standards.
Hazardous voltages are present at the AC power supply lines in this electrical equipment. Some components may
also have high operating temperatures.
Failure to observe and follow all installation and safety instructions can result in serious personal injury
or property damage.
Therefore, only trained and qualified personnel may install and maintain the system.

The same text in German:


Wichtiger Hinweis zur Produktsicherheit
LEBENSGEFAHR - BEACHTEN SIE ALLE INSTALLATIONSHINWEISE.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Alle an das System angeschlossenen
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
In diesen Anlagen stehen die Netzversorgungsleitungen unter gefährlicher Spannung. Einige Komponenten
können auch eine hohe Betriebstemperatur aufweisen.
Nichtbeachtung der Installations- und Sicherheitshinweise kann zu schweren Körperverletzungen oder
Sachschäden führen.
Deshalb darf nur geschultes und qualifiziertes Personal das System installieren und warten.

Caution:
This equipment has been tested and found to comply with EN 301489. Its class of conformity is defined in table
A30808-X3247-X910-*-7618, which is shipped with each product. This class also corresponds to the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accor-
dance with the relevant standards referenced in the manual “Guide to Documentation”, may cause harmful inter-
ference to radio communications.
For system installations it is strictly required to choose all installation sites according to national and local require-
ments concerning construction rules and static load capacities of buildings and roofs.
For all sites, in particular in residential areas it is mandatory to observe all respectively applicable electromagnetic
field / force (EMF) limits. Otherwise harmful personal interference is possible.

Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for their own purposes
could violate the rights of their owners.

Copyright (C) Siemens AG 2004.

Issued by the Information and Communication Networks Group


Hofmannstraße 51
D-81359 München

Technical modifications possible.


Technical specifications and features are binding only insofar as
they are specifically and expressly agreed upon in a written contract.

2 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

Reason for Update


Summary:
Second Edition for Release BR All

Details:
Chapter/Section Reason for Update

all Update to BS-240 / 240 II / 240XL / 240XL II

Issue History
Issue Date of issue Reason for Update
Number

1 7/2000 New release BR All

2 4/2004 Update to BS-240 / 240 II / 240XL / 240XL II

A30808-X3247-A340-2-7620 3
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

This document consists of a total of 84 pages. All pages are issue 2.

Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1 Objective of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.2 Target Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 Range of Replaceable Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 Qualitiy and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5 Risks and Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.6 Explanation of used Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2 Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 Remove/Mount Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2 Remove/Mount Rear Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3 Remove/Mount Side Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.4 Remove/Mount Top Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.5 Remove/Mount ACTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.6 Remove/Mount ACTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.7 Remove/Mount ACTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.8 Remove/Mount Temperature Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
2.9 Remove/Mount MSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
2.10 Remove/Mount Over Voltage Arrester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
2.11 Remove/Mount Over Voltage Protection Base . . . . . . . . . . . . . . . . . . . . . . 52
2.12 Remove/Mount OVPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
2.13 Remove/Mount Lightning Arrester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2.14 Remove/Mount Clamping Saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2.15 Remove/Mount AC Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
2.16 Remove/Mount DC Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
2.17 Remove/Mount Door Alarm Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
2.18 Remove/Mount Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
2.19 Remove/Mount Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
2.20 Remove/Mount DC Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

3 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

4 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

4 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

Illustrations
Fig. 1.1 Example Special Torx- Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Fig. 1.2 Used Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

A30808-X3247-A340-2-7620 5
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

6 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

1 Introduction
1.1 Objective of the Manual

In general, the faults occuring in a BTSE are reported to the OMC by error reports.
These are based on system integrated routine tests which continually check the function
of all subsystems. In most cases suspected modules can be replaced according to the
procedures of the maintenance manual and regarding the fault reports.
For all the rare cases where an exchange of modules doesn’t clear the fault, parts of the
system can also be replaced but only by dismantling components spending higher effort
then for simple module replacement.
The aim of this manual is to describe how the location of these parts can be accessed
and to show in detail how a part can be replaced.

Restriction
Only the pure exchange procedures are dealt with in this manual, not the instructions of
fault location nor the test procedures afterwards.

1.2 Target Group

This manual is exclusively intended for use by TAC2 and TAC3 personnel. Only trained
and qualified people may carry out the non standard maintenance tasks.

1.3 Range of Replaceable Parts

The range of parts to be exchanged is restricted to those listed in the Main Construction
Catalogue (MCC) which can be reached via Siemens Intranet and IMS.

1.4 Qualitiy and Tools

All tasks must be carried out thoroughly. Cleanliness and care are of the utmost impor-
tance. Precautions has to be taken to protect the equipment against dust, mud and
moisture of all kind.
Only parts which don’t need a calibration or extensive tests after replacement are sub-
ject of exchange.
Tools should be of a high-quality standard as listed in the table of “Tools and Testequip-
ment D900/D1800/PCS1900” (A30862-X390-A101-*-7618). Special tools are neces-
sary e.g. Torx screw driver with and without a hole in the center. For more
convenience a power-driven screw driver can save some time when releasing large
amounts of screws.

A30808-X3247-A340-2-7620 7
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

Handle:
Width: 1/4 Inch
Length: 120 mm

Bits 1/4 Inch, Torx


size:
8
10
15
20
25
(27)
30
(40)

Fig. 1.1 Example Special Torx- Tools

1.5 Risks and Safety

Elevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures. Exposed sharp edg-
es involve a certain danger of injuring oneself.
The following warnings appear at the relevant procedures were necessary:
Elevated voltages are present at specific points.
!

Some parts may have elevated operating temperatures.


!

Because of sharp edges, handle with particular caution so as not to cut yourself
! or alternatively use hand protection.

Rotating parts may be still in action for a few seconds after removing.
!

When replacing components in the AC circuit, it must be guaranteed that the AC power
supply to the shelter is switched off and secured against switching on again.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
It is highly advisable to carry out all tasks with the support of a second person for assist-
ing in moving heavy parts and for safty reasons in the event of an accident.

8 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

1.6 Explanation of used Symbols

The following symbols are used in this manual:

Symbol Meaning

Warning; the notes given here are to be followed with care.


! Non-observance can lead to personal injury or property damage.

ESD (Electrostatic Sensitive Device) precautions to be taken

i Note; important information

b Use the LMT to enter commands

h Reference to another procedure step

☞ Reference to another chapter

i Reference to another procedure. Return after finishing.

Fig. 1.2 Used Symbols

A30808-X3247-A340-2-7620 9
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

10 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2 Procedures

A30808-X3247-A340-2-7620 11
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

12 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.1 Remove/Mount Door

1 Remove Door

1. Open door
2. Remove the ground cable (1a) by loosening the screw (1b)
3. Loosen lower screws on top and bottom hinge (2a,2b) and middle hinge in
case of BS240XL (without figure)

1b
1a

2a

2b

4. Lower part of hinge will move down


5. Lift and pull to remove door (screws remain in door!)

1b
1a

A30808-X3247-A340-2-7620 13
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2 Mount Door
1. Hinge door loose
2. Close hinge by moving up the lower part of the hinge and tighten screws
(2a,2b) and screw on middle hinge (in case of BS240XL)
3. Connect ground cable (1a) with screw (1b) to door
4. Make sure door will close properly
5. Ensure, that the lock closes right

Please note that the new door has a new lock with new keys.
If necessary change lock See “Remove/Mount Lock” on page 77.

3 Print new Labels

The serial numbers on the labels should be correct, therefore is it necessary ei-
ther to print new labels or to change the document case (in case the document
case is not damaged)

1. Take your label printer and make a identical printout of the labels at the inside
of the old door
2. Paste the labels to the right position at the new door (see Figure below)

Alternative, only if the document case on the old door is O.K.

1. Remove the document case on the new door by loosening 3 screws (3


2. Remove the document case on the old door by loosening 3 screws (3)

3. Mount the old document case on the new door by tightening 3 screws (3)

END

14 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.2 Remove/Mount Rear Cover

1 Remove Rear Cover

1. Remove all 8 screws(2) on back cover (1)


2. Ensure rear cover is held in place

2
2

A30808-X3247-A340-2-7620 15
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

3. Lower rear cover slowly to ground, pay attention to the ground cable (2a)
4. Remove ground cable (clip) (2b)

2a

2b

2 Mount Rear Cover


1. Set rear cover close to Rack and connect ground cable (2a)
to rear cover (1)
2. Hold rear cover in position and insert all 8 screws
3. Tighten srews

END

16 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.3 Remove/Mount Side Cover

1 Remove Side Cover

1. Open door
2. Remove rear cover (See “Remove Rear Cover” on page 15.)
3. If door side cover has to be removed, remove door (See “Remove Door” on
page 13.)
4. Remove top cover (See “Remove Top Cover” on page 20.)
5. Remove cage nuts (1) on back on the affected side
6. Remove screws on back that hold side cover (2)

1 1
2
2

A30808-X3247-A340-2-7620 17
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

7. Remove ring-bolts (3)

8. Depending on side, remove hinges (4) or breech-blocks (5)

4 5
9. Lift top frame (6) and pull out side cover

18 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

10. Remove ground cable (7)

7
11. Remove side cover

2 Mount Side Cover


1. Set side cover close to rack
2. Connect ground cable (7) to side cover
3. Lift top frame slightly (6)
4. Bring side cover into position, set top frame back into place
5. Insert screws on backside of back cover (2)
6. Insert cage nuts at the back (1)
7. Depending on side, mount hinges (4) or breech blocks (5), back on front side
8. Mount back cover (See “Mount Rear Cover” on page 16.)
9. Screw ring bolts back on top (3)
10. If door side cover was changed, mount door (See “Mount Door” on page 14.)
11. Mount top cover (See “Mount Top Cover” on page 21.)

END

A30808-X3247-A340-2-7620 19
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.4 Remove/Mount Top Cover

1 Remove Top Cover

1. Open door
2. Unscrew bolts on front side (1)

1 1

4
3. Lift front of top cover slightly and move cover back a few centimeters

4. Lift entire cover and move it aside, but do not remove cover completely from
top!

20 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

5. Detach ground cable (2) (clip). Only in case of Base Rack

6. Remove top cover

2 Mount Top Cover


1. Set top cover on rack
2. Connect ground cable (2) to top cover (clip)
3. Set space in back of top cover on bolts and pull top cover forward. Keep front
of cover lifted
4. Set front of top cover on rack
5. Insert bolts (1) on front of rack and tighten them
Make sure bolts are used as shown in 4

END

A30808-X3247-A340-2-7620 21
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.5 Remove/Mount ACTC

1 Remove ACTC

1. Open door
2. Switch circuit breaker BR05 on the DC panel to OFF position
3. Unplug alarm cables (1) in front mark each separately and note their posi-
tions!

Base Rack

Extension Rack
1

4
Service1 Rack

Service2 Rack

22 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

4. Loosen screws (2) on side of DC panel

5. Pull out DC panel as far as possible. You may have to rearrange some cabling
inside

6. Disconnect cables (3) in back of ACTC mark each separately and note their
positions!
Please note: There is no CAN-Bus cable on ACTC for Base Rack

Example Service1 Rack

A30808-X3247-A340-2-7620 23
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

7. Loosen screws (4) on DC panel


8. Remove ACTC

Example Base Rack

ACTC front view

CAN IN
CAN OUT

X6 Connection to ACTP

52 51 50 49 48 47

ACTC back view

24 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2 Mount ACTC
1. Set ACTC into DC panel, fix position with screws (4) in front
2. Connect cables (3) in back, use notes to determine positions of cables
3. Tighten screws (2) on side of DC panel
4. Connect alarm cables (1) in front, use notes to determine positions of cables
5. Switch circuit breaker BR 05 to ON position

END

A30808-X3247-A340-2-7620 25
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.6 Remove/Mount ACTA

1 Remove ACTA

ACTA is optional only in Base Rack!

1. Open door
2. Switch circuit breaker BR05 on the DC panel to OFF position
3. Remove top cover (See “Remove Top Cover” on page 20.)
4. Disconnect all alarm cables/connectors from ACTA, note their positions
5. Loosen screws that hold ACTA/ACTP (1)

6. Remove ACTA/ACTP and detach CAN-Bus cable (2)

26 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

7. Separate ACTA and ACTP by removing screws (3) and unplugging ACTA.

ACTA upside

ACTA downside

A30808-X3247-A340-2-7620 27
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2 Mount ACTA
1. Combine ACTA and ACTP using screws (3)
2. Connect ACTA/ACTP to CAN-Bus (2) and set it back on cover plate.
3. Tighten screws (1) around ACTA/ACTP
4. Reconnect all alarm cables/connectors use your notes
5. Mount top cover (See “Mount Top Cover” on page 21.)
6. Switch circuit breaker BR05 on the DC panel to ON position

END

28 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.7 Remove/Mount ACTP

1 Remove ACTA/ACTP on Base Rack

1. Open door
2. Switch circuit breaker BR05 on the DC panel to OFF position
3. Remove top cover (See “Remove Top Cover” on page 20.)
4. Disconnect all alarm cables/connectors from ACTA, note their positions
5. Loosen screws that hold ACTA/ACTP (1)

6. Remove ACTA/ACTP and detach CAN-Bus cable (2)

A30808-X3247-A340-2-7620 29
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

7. Separate ACTA and ACTP by removing screws (3) and unplugging ACTP

DIP
switch

ACTP upside

ACTP downside

30 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2 Mount ACTA/ACTP on Base Rack


1. Check the DIP switches of the new ACTP it must be the same setting as the
old one
2. Combine ACTA and ACTP using screws (3)
3. Connect ACTA/ACTP to CAN-Bus (2) and set it back on cover plate
4. Tighten screws (1) around ACTA/ACTP
5. Reconnect all alarm cables/connectors use your notes
6. Mount top cover (See “Mount Top Cover” on page 21.)
7. Switch circuit breaker BR05 on the DC panel to ON position

3 Remove ACTP on Extension Rack


1. Open door
2. Switch Circuit breaker BR05 on the DC panel to OFF position
3. Remove Top Cover (See “Remove Top Cover” on page 20.)
4. Loosen screws that hold plate of ACTP (1)

5. Remove plate with ACTP and detach CAN-Bus cable (2) and X6 connection

A30808-X3247-A340-2-7620 31
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

(3) to ACTC (if present)

32 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

6. Separate ACTP from plate by removing screws (3)

DIP
switch

ACTP upside

ACTP downside

A30808-X3247-A340-2-7620 33
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

4 Mount ACTP on Extension Rack


1. Check the DIP switches of the new ACTP it must be the same setting as the
old one
2. Combine plate and ACTP using screws (3)
3. Connect ACTP to CAN-Bus (2) and X6 connection (3) to ACTC and set it
back on cover plate
4. Tighten screws (1) around plate of ACTP
5. Mount top cover (See “Mount Top Cover” on page 21.)
6. Switch circuit breaker BR05 on the DC panel to ON position

34 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

5 Remove ACTP on Service Rack


1. Open door
2. Switch Circuit breaker BR05 on the DC panel to OFF position
3. Remove top cover (See “Remove Top Cover” on page 20.)
4. Loosen screws that hold plate of ACTP (1)

5. Remove plate with ACTP and detach CAN-Bus cable (2) and X6 connection
(3) to ACTC

A30808-X3247-A340-2-7620 35
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

6. Separate ACTP from plate by removing screws (3)

DIP
switch

ACTP upside

ACTP downside

36 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

6 Mount ACTP on Service Rack


1. Check the DIP switches of the new ACTP it must be the same setting as the
old one
2. Combine plate and ACTP using screws (3)
3. Connect ACTP to CAN-Bus (2) and X6 Connection (3) to ACTC (if present)
and set it back on cover plate
4. Tighten screws (1) around plate of ACTP
5. Mount Top Cover (See “Mount Top Cover” on page 21.)
6. Switch Circuit breaker BR05 on the DC panel to ON position

END

A30808-X3247-A340-2-7620 37
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.8 Remove/Mount Temperature Sensor

The temperature sensor is located on the ACTC.

1 Remove/Mount Temperature Sensor

The temperature sensor is part of the ACTC and cannot be removed separate-
ly. In case of a defective sensor, ACTC has to be exchanged, See “Re-
move/Mount ACTC” on page 22..

Temperature Sensors

END

38 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.9 Remove/Mount MSU

1 Remove MSU DC on Base Rack

1. Open door
2. Lock all CUs and Combiners in the Base Rack and Extension Rack(s) if
present (see Maintenance Manual)
3. Switch off the (48VDC) main circuit breaker in Service1 Rack for the Base
Rack
4. Open top cover (See “Remove Top Cover” on page 20.)
5. Remove cover plate on top of rack (1). Just loosen screws, they will stay on
plate

A30808-X3247-A340-2-7620 39
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

6. Detach cabling to ground (2a) and LPA connector (2b)

2a

2b

7. Uncover power connection (3)

40 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

8. Loosen screws that hold MSU DC in place (4)

9. Pull out MSU DC


10. Uncover and disconnect power cable (5)

A30808-X3247-A340-2-7620 41
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2 Mount MSU DC on Base Rack


1. Connect power cable (5)
2. Insert MSU DC in top frame and tighten screws (4)
3. Cover power connection (3)
4. Connect ground (2a) and LPA (2b) cable. Make sure the ground cables are
connected without tension and bolts are placed as in the picture (6)

2b

2a

Ground Cable Arrangement

5. Mount Top Cover (See “Mount Top Cover” on page 21.)


6. Switch on the (48VDC) main circuit breaker in Service1 Rack for the Base
Rack
7. Unlock all CUs and Combiners in the Base Rack and Extension Rack(s) if
present (see Maintenance Manual)

42 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

3 Remove MSU DC on Extension Rack


1. Open door
2. Lock all CUs and Combiners in the rack concerned (see Maintenance Man-
ual)
3. Switch off the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
It is not necessary to switch off the Base Rack (parts of the BTS are still in
function)
4. Open Top Cover (See “Remove Top Cover” on page 20.)
5. Remove cover plate on top of Rack (1). Just loosen screws, they will stay on
plate

2b

1 2a

6. Detach cabling to ground (2a) and LPA connector (2b)(see picture above)

A30808-X3247-A340-2-7620 43
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

7. Uncover power connection (3) on EMI-Filter. This step is necessary to get


MSU DC out of EMI panel, otherwise, it won’t fit through space in EMI panel

44 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

8. Loosen screws that hold MSU DC in place (4)

9. Pull out MSU DC


10. Disconnect cable on EMI-Filter (5)

A30808-X3247-A340-2-7620 45
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

4 Mount MSU DC on Extension Rack


1. Connect cable on EMI panel(5)
2. Insert MSU DC in EMI panel and tighten screws (4)
3. Cover connection on EMI filter(3)
4. Connect ground (2a) and LPA (2b) cable. Make sure the ground cables are
connected without tension and bolts are placed like picture(6)

2b

2a

5. Mount top cover (See “Mount Top Cover” on page 21.)


6. Switch on the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
7. Unlock all CUs and Combiners in the Base Rack and Extension Rack(s) if
present (see Maintenance Manual)

46 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

5 Remove MSU DC on Service Rack


1. Open door
2. Switch off the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned. If the rack concerned is the Service1 Rack, then first of all lock all
CUs in Base Rack and Extension Rack(s), switch off both battery circuit
breaker and all AC circuit breaker
3. Open top cover (See “Remove Top Cover” on page 20.)
4. Remove cover plate on top of rack (1). Just loosen screws, they will stay on
plate
5. Detach cabling to ground (2a) and LPA connector (2b)
6. Loosen screws that hold MSU DC in place (4)

2b

2a
1

A30808-X3247-A340-2-7620 47
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

7. Pull out MSU DC. If necessary, pull gently on grey cable (7) to get MSU DC
out.

8. Disconnect cable on EMI filter using a normal flat screw driver (5). Note con-
nection order. Cables are numbered!

48 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

6 Mount MSU DC on Service Rack


1. Connect cable (7) to EMI filter. Use taken notes and cable-numbering
2. Insert MSU DC in EMI panel and tighten screws (4)
3. Connect ground (2a) and LPA (2b) cable. Make sure the ground cables are
connected without tension and bolts are placed as in the picture (6)
4. Mount top cover (See “Mount Top Cover” on page 21.)

2b

2a
1

5. Switch on the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned. If the rack concerned is the Service1 Rack, switch on both battery
circuit breaker and all AC circuit breaker
6. Unlock all CUs and Combiners in the Base Rack and Extension Rack(s) if
present (see Maintenance Manual)

END

A30808-X3247-A340-2-7620 49
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.10 Remove/Mount Over Voltage Arrester

1 Remove Over Voltage Arrester

1. Remove top cover See “Remove Top Cover” on page 20.


2. Find MSU (1)

3. Pull the exhausted over voltage arrester

There exist different types of over voltage protection plugs for the BTSplus:
Over voltage arrester for 275V/15kA
Over voltage arrester for 250V/20kA
DC mains surge voltage protection for 120/250A
DC mains surge voltage protection for 150/15kA

50 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2 Mount Over Voltage Arrester


1. Insert a new over voltage arrester
2. Mount top cover (See “Mount Top Cover” on page 21.)

END

A30808-X3247-A340-2-7620 51
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.11 Remove/Mount Over Voltage Protection Base

1 Remove Over Voltage Protection Base

1. Remove top cover See “Remove Top Cover” on page 20.


2. Find MSU (1)

3. Pull the pertinent over voltage arrester

4. Loosen two screws (2)


5. Remove the cables (3)
6. Use screw driver to slip out lock, on bottom of over voltage protection base
(4) and remove it. (To lock over voltage protection base, move it down or try

52 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

to pull outside the lock, it will snap in automatically)

3 2

2 Mount Over Voltage Protection Base


1. Insert a new over voltage protection base
2. Put in the cables (3)
3. Fasten two screws (2)
4. Insert the over voltage arrester
5. Mount top cover (See “Mount Top Cover” on page 21.)

END

A30808-X3247-A340-2-7620 53
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.12 Remove/Mount OVPT

1 Remove OVPT

1. Remove top cover (See “Remove Top Cover” on page 20.)


2. Find OVPT (1). There are two different types of OVPT: OVPT 120 Ω with ter-
minal block and OVPT 75 Ω with SMA connectors

54 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

3. Disconnect all cables from terminal block (3b) or coaxial connectors (3c) and
note their positions
4. Dismantle all cables from clamping saddle (3a)
5. Remove screws (2) that hold OVPT in place. Note that screws have different
lengths! (2a, 2b)
6. Pull OVPT off. Be careful with loose parts!
7. Exchange broken parts or replace whole OVPT

3a

2a 2b

3b

2b 2a

3c

A30808-X3247-A340-2-7620 55
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2 Mount OVPT
1. Insert OVPT on rack, make sure it is proper plugged in
2. Use short screws (2a) in front, longer screws (2b) in middle of OVPT
3. Connect cables to clamping saddle (3a)
4. Connect all cables to terminal block (3b) or coaxial connectors (3c)
5. Close top cover (See “Mount Top Cover” on page 21.)

END

56 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.13 Remove/Mount Lightning Arrester

1 Remove Lightning Arrester

1. Remove top cover See “Remove Top Cover” on page 20.


2. Find OVPT (1)

3. OVPT with terminal block (left) and OVPT with SMA connectors are possible.
Unscrew 4 screws(2) to remove the plexiglas cover

2 2

4
OVPT 100Ω/120 Ω OVPT 75 Ω

A30808-X3247-A340-2-7620 57
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

4. To pull the exhausted lightning arrester, use the special tool

Special tool for inserting or removing lightning arrestor

2 Mount Lightning Arrestor


1. Insert a new lightning arrestor with the special tool(3)
2. Mount the plexiglas cover
3. Mount top cover (See “Mount Top Cover” on page 21.)

END

58 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.14 Remove/Mount Clamping Saddle

1 Remove Clamping Saddle on Base Rack

1. Remove top cover See “Remove Top Cover” on page 20.


2. Find OVPT (1)

3. Remove cables from clamping saddle


4. Loosen two screws (2) that hold the clamping saddle and remove it

3 2

2 4
Example: OVPT 100Ω/120 Ω

A30808-X3247-A340-2-7620 59
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

5. Tilt and pull to remove a single clamp

6. After replacement, connect cables and close cover

60 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2 Mount Clamping Saddle


1. Insert a new clamping saddle and hold in place (3)
2. Fasten two screws (2)
3. Mount cables to clamping saddle
4. To mount a single clamp, hold diagonally and press
5. Mount top cover (See “Mount Top Cover” on page 21.)

END

A30808-X3247-A340-2-7620 61
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.15 Remove/Mount AC Breaker

1 Remove AC Breaker

AC breakers are only present in the Service Rack. Always try to exchange
breakers with pulled out AC panel.
1. Open door
2. Lock all CUs and Combiners in the Base Rack and if present the Extension
Rack(s) (see Maintenance Manual MMN:BTSE BS 240l)
3. Switch all circuit breaker on the AC panel to OFF position
4. Switch off or disconnect the power at the power generation side!
5. Remove AC panel cover. Screws (1) cannot fall off!

62 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

6. Remove screws (2) on side of panel to pull out AC panel

AC-Breaker DC-Breaker
2 2

AC-Breaker DC-Breaker

7. Find breaker, that have to be removed. Remove cables (3) on top and bottom
of breaker by loosening screws (4)

5
3
pull 5 to release breaker

8. Use screw driver to pull down lock on bottom of breaker (5) and remove
breaker. (To lock breaker, move lock up or try to pull lock towards you, it will

A30808-X3247-A340-2-7620 63
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

snap in automatically)

2 Mount AC Breaker
1. Insert breaker and move lock up (5) or try to pull lock towards you, it will snap
in automatically
2. Connect cables (3) on top and bottom of breaker by fasten screws (4)
3. Fasten screws (2) on side of panel
4. Mount AC panel cover. Fasten screws (1)
5. Switch on or connect power at the power generation side
6. Switch all circuit breaker on the AC panel to ON position
7. Unlock all CUs and Combiners in the Base Rack and if present the Extension
Rack(s) (see Maintenance Manual MMN:BTSE BS 240)

END

64 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.16 Remove/Mount DC Breaker

The different rack types may have different preconditions for exchanging DC breakers.
Depending on the cabling, it may be impossible to pull out the DC panel far enough to
exchange the breaker (about 5 inches needed). In this case you have to exchange the
breaker through the EMI panel.

1 Remove DC Breaker on DC Panel through EMI Panel

1. Open door
2. Lock all CUs and Combiners in the rack concerned, if present (see Mainte-
nance Manual MMN:BTSE BS 240)
3. Switch off the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
(If the affected rack is an Extension Rack then it is not necessary to switch
off the Base Rack (parts of the BTS are still in function))
4. Remove Top Cover (See “Remove Top Cover” on page 20.)
5. Remove metal cover plate (1) on EMI panel by loosening screws (2)

6. Mark breaker that has to be exchanged (3)

A30808-X3247-A340-2-7620 65
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

7. Mark cables which are connected to the breaker. Remove cables (4). If they
are 50A breakers, you have to unscrew the cables

3
4

66 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

8. Remove screws on front of DC panel (5)


9. Remove breaker (6) by gently pushing towards the rack.

6 DC Breaker 4A, 10A, 16A


6 DC Breaker 50A

2 Mount DC Breaker on DC Panel through EMI Panel


1. Insert breaker (6) and fasten screws (5) on front of DC panel
2. Connect cables (4), in case of 50A breakers you have to screw the cables
3. Mount metal cover plate (1) on EMI panel by fasten screws (2)
4. Mount Top Cover (See “Mount Top Cover” on page 21.)
5. Switch on the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
6. Unlock all CUs and Combiners in the rack concerned, if present (see Main-
tenance Manual MMN:BTSE BS 240)

3 Remove DC Breaker by pulling DC Panel


1. Lock all CUs and Combiners in the rack concerned, if present (see Mainte-
nance Manual MMN:BTSE BS 240)
2. Switch off the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
(If the affected rack is an Extension Rack then it is not necessary to switch
off the Base Rack (parts of the BTS are still in function))
3. Unplug alarm cables in front (1) mark each seperately and note their posi-

A30808-X3247-A340-2-7620 67
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

tions

Base Rack

Extension Rack
1

4
Service1 Rack

Service2 Rack

4. Loosen screws on side of DC panel (2)

68 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

5. Pull out DC panel as far as possible. You may have to rearrange some cabling
inside

6. Mark the breaker that has to be exchanged, find and remove corresponding
cables (4) on the back and screws (3) on the front of DC panel. If they are
50A breakers, you have to unscrew the cables

Example 50 A Breakers
3

4 Mount DC Breaker by pulling the DC Panel


1. Insert breaker and fasten screws (3) on front of DC panel
2. Connect cables (4), in case of 50A breakers you have to screw the cables
3. Push in DC panel . You may have to rearrange some cabling inside
4. Fasten screws on side of DC panel (2)
5. Connect alarm cables in front (1) of ACTC
6. Switch on the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
7. Unlock all CUs and Combiners in the rack concerned, if present (see Main-
tenance Manual MMN:BTSE BS 240)

5 Replace DC Breaker on AC Panel


1. Open door
2. Lock all CUs and Combiners in the Base Rack and Extension Rack(s), if
present (see Maintenance Manual)

A30808-X3247-A340-2-7620 69
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

3. Switch all circuit breaker on the AC panel to OFF position


4. Switch off or disconnect the power at the power generation side!
5. Remove AC panel cover. Screws (1) cannot fall off!

6. Mark breaker that has to be exchanged

70 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

7. Remove screws (2) on side of panel to pull out AC panel

AC Breaker DC Breaker
2 2
3

AC Breaker DC Breaker

8. Mark cable which are connected to the breaker. Remove cables on top and
bottom of breaker by loosening screws (4)

4
3

9. Loosen screws (3) on front of DC Breaker


10. Remove breaker by gently pushing towards the rack

6 Mount DC Breaker on AC Panel


1. Insert breaker
2. Fasten screws (3) on front of DC breaker
3. Connect and fasten cables (4)
4. Fasten screws (2) on side of panel
5. Mount cover of AC panel by fasten screws (1)
6. Switch on or connect the power at the power generation side!
7. Switch all circuit breaker on the AC panel to ON position

A30808-X3247-A340-2-7620 71
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

8. Lock all CUs and Combiners in the Base Rack and Extension Rack(s), if
present (see Maintenance Manual)

END

72 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.17 Remove/Mount Door Alarm Sensor

1 Information

The sensor is screwed to the rack-frame on the upper left side. The replacement
kit also includes an angular metal flange for mounting to the rack. It is recom-
mended to use the existing mount and to exchange the sensor only. This way
the sensor doesn’t have to be adjusted in its position after the replacement.

2 Remove Door Alarm Sensor


1. Open door
2. Find door sensor (1)

3. Unplug alarm connection cable at ACTC (2)


4. Cut related cable straps (4), if present

A30808-X3247-A340-2-7620 73
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

5. Loosen plastic screws (3)

6. Remove sensor (1)

3 Mount Door Alarm Sensor


1. Fasten door alarm sensor with plastic screws (3)
2. Connect alarm connection cable at ACTC (2)
3. Fasten the cable to the rack-frame, use cable straps

END

74 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.18 Remove/Mount Handle

1 Remove Handle

1. Open door
2. Loosen hexagon screw (1) on the locking bar (wrench size: 10)
3. Loosen six cross recess head screws (2),(3) (screwdriver size: 1)

2
1

A30808-X3247-A340-2-7620 75
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

4. Remove handle

2 Mount Handle
1. Insert handle
2. Fasten six cross recess head screws (2),(3)
3. Fasten hexagon screw (1)
4. Close door
The new handle may have a new lock with new keys.
! If necessary change lock See “Remove/Mount Lock” on page 77.

END

76 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2.19 Remove/Mount Lock

1 Remove Lock

1. Loosen cross recess head screw (1) on handle (screwdriver size: 1)

2. Pull out the lock

2 Mount Lock
1. Insert lock
2. Fasten cross recess head screw (1)

END

A30808-X3247-A340-2-7620 77
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

2.20 Remove/Mount DC Panel

1 Information

It is suggested to check very carefully if a replacement of the DC panel is really


necessary! If a replacement is required, please prepare for this procedure.
Make sure you have cable markers and a list to note all connections. THIS PRO-
CEDURE SHOULD ONLY BE DONE BY SKILLED PEOPLE!

2 Remove DC Panel
1. Open door
2. Lock all CUs and Combiners in the rack concerned, if present (see Mainte-
nance Manual MMN:BTSE BS 240)
3. Switch off the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
(If the affected rack is an Extension Rack then it is not necessary to switch
off the Base Rack (parts of the BTS are still in function))
4. Unplug alarm cables in front (1) mark each separately and note their posi-
tions

Base Rack

Extension Rack 1

Service1 Rack
4

Service2 Rack

5. Remove top cover (See “Remove Top Cover” on page 20.)

78 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

6. Remove metal cover plate (3a) by removing screws (3b)

3b
3 4 3a

7. It is not necessary to remove the MSU (4) because it is easier to unplug the
cabling below the EMI panel (4a) (large blue and black cable)

4
4a

8. Remove all cable straps


9. Mark all cables connected to the DC panel
10. Make a list of cable connections and general cable arrangement

A30808-X3247-A340-2-7620 79
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

11. Unplug all cables on breakers (See “Remove DC Breaker on DC Panel


through EMI Panel” on page 65.)
12. Unplug all power cables
13. Loosen screws on side of DC panel (2). If necessary remove plate on side
(6) cover to get better access to the screw

14. Pull out DC panel as far as possible


15. Unplug all cables on ACTC (See “Remove ACTC” on page 22.)
16. Remove DC panel
17. Depending on completeness of the spare part remove ESD socket, ethernet
port, LMT interface, ACTC and breakers on the old DC panel

Example Base Rack

3 Mount DC Panel
1. Make sure you have the notes ready that you took while removing the DC
panel

80 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

2. Depending on completeness of the spare part mount ESD socket, ethernet


port, LMT interface, ACTC and breakers on the new DC panel (See “Mount
DC Breaker on DC Panel through EMI Panel” on page 67., See “Mount
ACTC” on page 25.)
3. Insert DC panel
4. Connect all cables on ACTC (See “Mount ACTC” on page 25.)
5. Push in DC panel
6. Fasten screws on side of DC panel (2). Close plate on side cover (6)
7. Connect all power cables
8. Connect all cables on breakers
9. Place the cables straps at suitable place
10. Mount metal cover plate (3a) by fasten screws (3b)
11. Mount top cover (See “Mount Top Cover” on page 21.)
12. Connect alarm cables in front of DC panel (1)
13. Switch on the (48VDC) main circuit breaker in Service1 Rack for the rack
concerned
14. Unlock all CUs and Combiners in the rack concerned, if present (see Main-
tenance Manual MMN:BTSE BS 240)

END

A30808-X3247-A340-2-7620 81
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

3 Abbreviations
AC Alternating Current
ACT Alarm Collection Terminal
BTSE Base Transceiver Station Equipment
CAN Controller Area Network
DC Direct Current
EMI Electro Magnetic Interference
ESD Electrostatically Sensitive Device
IMS Information Management System
LMT Local Maintenance Terminal
LPA Lightning Protection Alarm
MCC Main Construction Catalogue
MSU Main Supply Unit
OMC Operation and Maintenance Centre
OVPT Overvoltage Protection
SMA Subminiatur Adapter
TAC Technical Assistance Center

82 A30808-X3247-A340-2-7620
Nonstandard Maintenance NM:BTSE
Base Transceiver Station Equipment BS-240 / 240 II / 240XL / 240XL II

4 Index
A Mount 42, 46, 49
AC Breaker Remove 39, 43, 47
Mount 64
ACTA O
Mount 28, 31 Over Voltage Arrestor
Remove 26, 29 Insert 51
ACTC Remove 50
Mount 25 Over Voltage Protection Base
Remove 22 Mount 53
ACTP Remove 52
Mount 31, 34, 37 OVPT
Remove 29, 31, 35 Mount 56
Remove 54
C
Cage Nuts 17 P
Clamping Saddle Print new Labels 14
Mount 61
Remove 59 R
Rear Cover
D Mount 16
DC Breaker Remove 15
Mount 67, 71
Remove 65, 69 S
DC Panel Side Cover
Mount 80 Mount 19
Remove 78 Remove 17
Document Case
Mount 14
T
Remove 14
Door Temperature Sensor 38
Mount 14 Top Cover
Remove 13 Mount 21
Door Sensor Remove 20
Mount 74
Remove 73

H
Handle
Mount 76
Remove 75

L
Lightning Arrestor
Insert 58
Remove 57
Lock
Mount 77
Remove 77

M
MSU

A30808-X3247-A340-2-7620 83
NM:BTSE Nonstandard Maintenance
BS-240 / 240 II / 240XL / 240XL II Base Transceiver Station Equipment

84 A30808-X3247-A340-2-7620